Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for laying of drain pipes,manholes,etcandgetting out inhard/densesoil complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 3 | Removing excavated materials in soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.50 m above the starting point all as specified and directed. |
| 4 | Forming enbankments including raising (or lowering earth spreding in layers exc. 30 thick watering ramming /rolling and finishing to required size shape exc n.exc 1.5 m ht from base complete all as specified and directed. |
| 5 | M & L Hard core of huage exc 63 mm but n exc 100mm deposited spreding leveling in layers n exc 15 cm thick complete all as specified and directed. |
| 6 | M & L PCC (1:4:8)type D2(using 40mm graded stone aggregate)as in foundations filling and mass concrete complete all as specified and directed. |
| 7 | Demolition of RCC of any description and in any position not otherwise specifically provided reinforced (reinforcement of cut as required to facilasite demolition etc) and removal of rubbish/ demolished materials out of MD landcomplete all as specified and directed. |
| 8 | M&L Providing RCC (1:2:4) (nominal mix) type B1 (using 20 mm graded stone aggregate) as inbandssupported on walls, beams and columns in floors,roof, landings, balconies, canopies, deck slabs and in shelves and the like complete all as directed. |
| 9 | M&L Providing RCC (1:2:4) type B-1(using 20 mm graded stone aggregate) as in plinth beams, cantilevers bressummers lintels over 1.5 m span,etc complete all as specified and directed. |
| 10 | M&L PCC (1:2:4) type B1 (using 20mm graded stone aggregate) asin copings, kerbs, channels, water through and the like including weathering, slightly rounded or chamfered angles and throating as directed chamfered necessary for work complete all as specified and directed. |
| 11 | Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter finished rough surfaces complete all as specified and directed. |
| 12 | Use and waste of Form work to sides and soffits of floor or roof beams, beam haunching, lintel etc rough finished surfaces of concrete flat surfaces complete all as specified and directed. |
| 13 | Demolition of brickwork or stone/boulder masonry, built in cement mortar with all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articlesincludingremoval of rubbish/ demolished materials out of MD landcomplete all as specified and directed. |
| 14 | M&L Brick work with using flyashbricks old sizestraight or curved on plan exceeding 6 m mean radius built in CM (1:6) complete all as specified and directed. |
| 15 | M & L Half brick work with using old sizeflyash bricks , straight or curved on plan exc 6.0 m mean raduis and built in CM (1:4) as in partition wallscomplete all as specified and directed. |
| 16 | M & L Precast cement concrete block masonry with solid blocks exceeding 10cm in width by using precast cement concrete (1:3:6) type C1 (using 20 mm graded stone aggregate) and set in CM (1:6)complete all as specified anddirected. |
| 17 | Taking down chowkats or frame with shutters ( without taking off shutters from the frame ) not exceeding 1.5 Sqm each complete all as specified and directed. |
| 18 | Taking down chowkats or frames with shutters (without taking off shutters from frames) of size exceeding 1.5 sqm but not exceeding 4 sqm each complete all as specified and as directed. |
| 19 | S&F Pressed steel frames for doors of size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc with one coat of primer complete all as specified and as directed |
| 20 | S & F Pressed steel frames for doors of size 105 x 60 mm with one or more rebates incl necessary fixing lugs, hinges, lock strike plate, etc with one coat of primer complete all as specified and as directed. |
| 21 | Cutting holes in brick wall built in cement mortor for inserting hold fast and making good the disturbed portion in CM (1:3) depth of embeded portion exc half brick & not exc one brick etc completed all as specified and directed by Engr-in-Charge. |
| 22 | M&L PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in coping, bed plates, filling back hollow portion of chowkatscomplete all as specified and as directed. |
| 23 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/sqmm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 24 | S & F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/sqmm, modulus of elasticity 850 N/sqmm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. |
| 25 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawings given in Section 8 of MES Schedule Part-II 2020 as applicable complete all as specified and as directed |
| 26 | S & F PVC solid ventilator frame size 55 X 47mm with wall thickness of 5mm made out of extruded 5mm PVC sheet, mitre cut at two comers and jointed with 2 Nos of 150mm long brackets of 15 x 15mm MS square tube the two vatted profiles are to be reinforced with 19 x 19mm MS squre tube the 50% of bottom portion is fixed with 4mm pin headed glass and balance 50% of top portion is fixed with 4mm thick pin headed glass lowers and cover with 0.36mm dia stainless steel wire mesh at top portion including necessary PVC beading with screws and 3 Nos 12mm dia MS guard, bars fixed in ventilator frame including two coats of synthetic enamel paint over a coat of red oxide primer to MS guard bars etc all as per specified and directed (Make SINTEX or epuivalentin RAJSHRI/NANDImake as approved by accepting officer) complete all as specified and as directed |
| 27 | S&F Steel windows (fly proof and glazed shutter) made with galvanised steel colour coated/ powder coated (Base steel as per IS 513 \"D\", galvanised as per IS 277 with zinc of 120gm/sqm) with total coating thickness of 0.60mm (outside for glazing and inside gauged shutter) Sections forframe should be of 72mmx55mm, section for mullian should be72mm x 50mm section for shutterframe should be 47mmx 20mm andsection for fixing glass bead should be 12mm x 12mm and section for fly mesh shutter frame should be 40mm x 20mm mesh fixing should be of 18mm x 0.6mm.Stainless steel wire mesh of 0.45mm dia and average width of aperture 1.4mm shall be used for fly proofing 4mm thick plain sheet glass to be used for glazing of glazed shutters complete all as specified and directed. |
| 28 | S & F 40mm thick flush shutters solid core construction with block board core and ply wood face panels, commercial type on both sides etc complete all as specified and directed. |
| 29 | S & F 35 mm 1st class hard wood factory made glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars) edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc size of member of shutter as specified in SSR Part-I section 8 clause 8.24(a) etc completed all as specified and directed by Engr-in-Charge. |
| 30 | S & F 30 mm 2ndclass hard wood factory made glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars) edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc size of member of shutter as specified in SSR Part-I section 8 clause 8.24(a) etc completed all as specified and directed by Engr-in-Charge. |
| 31 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc all as specified and directed. |
| 32 | S&F 100 mm size MS butt hinges,medium weight,cold rolled mild steel hinge pin,anodized and fixed complete all as specified and directed. |
| 33 | S&F 100 mm sizebutt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type C-22 complete all as specified and as directed |
| 34 | S&F 50 mm sizebutt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type E-22 complete all as specified and as directed |
| 35 | S & F 150 mm long aluminium handles, cast type anodised extruded section and fixed complete all as specified and directed. |
| 36 | S & F 150 mm longaluminium anodized barrel tower bolt of extruded section complete all as specified and directed. |
| 37 | S&F Mild steel 300 mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed |
| 38 | S&F 150 mm long Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixingclips of sheet, cast or extrudedsections and fixing bolts andsliding bolts of extrudedsections or cast-aluminiumalloy and fixed and fix complete all as specified. |
| 39 | M&L in repairs MDF board, 18/19 mm thick exterior grade, pre-laminated both sidedecorative face lamination fixed with screws ,brackets to timber frame work with and including 1st class hard wood, 6 mm thick allaround edging, complete all as specified and directed. |
| 40 | M&L in repairs MDF board, 12 mm thick exterior grade, pre-laminated both sidedecorative face lamination fixed with screws ,brackets to timber frame work with and including 1st class hard wood, 6 mm thick allaround edging, complete all as specified and directed. |
| 41 | S & F Continuous (piano) hinges,mild steel, bright finish or electrogalvanised 40mm width of flap fixed with screws as in repairs |
| 42 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets or frame workcomplete all as specified and directed. |
| 43 | S & FE Grid suspended false ceiling grid system of size 600 x 600mm with main runner 39x29.7x0.60mm cross tee 29x24.7x0.60mm and wall angle 22.2x22.2x0.50mm ceiling suspended with 2 to 2.5 mm dia GI wire hanger fixed to purlin / truss etc complete (Main runner, cross tee, wall angle of MS galvanised with PPCGS)fixed to frames etc complete all as specified and as directed by Engr-In-Charge. |
| 44 | S&F ofTowel Rail 600mm long of Stainless steel fixed withand including Chromium plated brassscrews and wooden/plastic cleats.(Minimum weight 190 gms) and complete all as specified. |
| 45 | S & F in repairs anodized aluminium alloy powder coated curtain rod 19 mm dia of standard thickness with fixing brackets, stops, rollers etc complete all as directed. |
| 46 | S&F Stainless steel curtain rod of 25 mm bore fancy typecomplete all as specified and as directed |
| 47 | S&F Stainless steel curtain rod brackets (decorative type) suitable for curtain rod of 25 mm dia, complete all as specified and as directed. |
| 48 | M&L TMTbars 10 mm dia and over, cut to length, bent to shaperequired, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia orsecuring with clips,complete all as specified and directed. |
| 49 | All as per Item No.48 above,but6mm to 8 mm dia |
| 50 | All as per Item No.48 above,but5mm dia and over upto and including 10mm dia as in stirrups , spacers and binders etc |
| 51 | S&F Rolled mild steel sections of Fe 410-W (GDE E-250) QUALITY “A” frame work as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and as directed. |
| 52 | S&F MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) Fe-410-W(Gde-E-250) quality B forming holes without any attachment complete all as specified and directed |
| 53 | S&FRolled sections as in main and cross beams, hip and jack, trusses ,post , rafter where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates to Fe-290 (Gde E- 165) complete all as specified and directed. |
| 54 | S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing boltsposts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 Fe-290 (Gde E- 165) complete all as specified and directed. |
| 55 | S&FRoof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. to Fe-290 (Gde E- 165) complete all as specifiedcomplete all as specified and directed. |
| 56 | S&FWind ties for roof including securing bolts including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 etc complete all as specified and directed. |
| 57 | Dismantling timber Scantling framed work in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed. |
| 58 | Dismantling timber Scantling framed work 40 sqcm and over in section, in any position and removing store complete all as specified and as directed. |
| 59 | Dismantling of asbestos cement sheet /Plain or corrugated steel sheeting, (corrugated or semi corrugated) in roof covering complete all as specified and as directed. |
| 60 | S&FPre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as inroof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 61 | S&F Pre painted Galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 62 | Dismantling stone slabs and tiles of any description or thickness in floor, aprons laid bedded and pointed in any mortar including removal of rubbish/ demolished materials out of MD landcomplete all as specified and directed. |
| 63 | M&L Non skid coloured ceramic tiles of size exceeding .0.06 sqm but not exceeding 0.11 sqm of 7 to 8 mm thick set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15 mm thick CM (1:6)screed bedcomplete all as specified and as directed. |
| 64 | M&L Glazed ceramic coloured wall tiles of approved colour of size 350x 250x 7/ 450x300x7 mm thick on vertical surfaces as in dado/wall set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 10 mm thick CM (1:4) backing coat complete all as specified and as directed |
| 65 | M&L Designer rubber moulded chequerred cement concrete tiles of size 300 x 300 x 22mm or 250 x 250 x 22mm thickwith mixture of greyand white cemetn in equal porportions with pigments and set and pointed in neat cement slurry asin floors over and including 15 mm thick CM (1:6) screed bed or bedding layer for laying floor finishes etc complete all as specified and as directed. |
| 66 | M&L 25 mm thick granite tiles (of any size) machine cut, jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone duly grinding and polishing laid over and including 15mm thick screed bed CM (1:4) as in steps, jambs, pillars, window cills, cooking platforms and like complete all as specified and as directed. |
| 67 | Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified. |
| 68 | Demolition of Cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) includingremoval of rubbish/ demolished materials out of MD landcomplete all as specified and directed. |
| 69 | M&L 40 mm thick PCC (1:2:4)type B-1 (using 20 mm graded stone aggregate) as in flooring complete all as specified and directed. |
| 70 | M&L 75 mm thickPCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base to floor complete all as specified and as directed. |
| 71 | M&L 75 mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) asin plinth protection laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight and top 10 mm depth sealed with sealing compound grade ‘A’ complete all as specified and directed. |
| 72 | M&L Providing 60 mm thickness, M-35 Grade, machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 ofwith grey cement and pigment complete all as specified and directed. |
| 73 | Taking down cement plaster from brick/stone wallof any description etc including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed. |
| 74 | M&L Rendering 10 mm thick CM (1:6) on other than fair faces of brick surfaces, finished even and smooth without using extra cement.complete all as specified and as directed |
| 75 | M&L Rendering 10 mm thick CM (1:4) onfair faces of brick work or concrete surfaces, finished even and smooth without using extra cement.complete all as specified and as directed |
| 76 | M&L Rendering 15 mm thick in two coats, 10 mm thick in CM (1:6)and 5 mm thick in CM (1:4)mixed with integral water proofing compound as per manufacturers instructions, on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound shall be measured and paid separately. |
| 77 | Supply only water proofing compound |
| 78 | M & L Preparing newly plastered wall surfaces and applying three coats of white wash complete all as specified and as directed. |
| 79 | M & L Preparing the old plastered or unplastereddecorated surfaces of walls and applying two coats of white wash complete all as specified and as directed. |
| 80 | M & L Complete removal of existing treatment on wall surfaces and applying two coats of Acrylic distemperover and includinga coat of alkali resistant primer over and including 3 mm thick wall care putty in two layerscomplete all as specified and as directed. |
| 81 | M & L Preparing newly plasterd wall surfaces of walls and applying two coats of Acrylic distemperover and includinga coat of primer using chalk whiting over and including 3 mm thick wall care putty in two layerscomplete all as specified and as directed. |
| 82 | M & L Preparing old plasterd wall surfaces of walls and applying two coats of cement base paint of any colourcomplete all as specified and as directed. |
| 83 | M&L Preparation of newly plastered surfaces of walls and applying 2 coats of apexultima weather proofpaint over a coat of apex ultima primer including preparation of surface and complete all as specified and directed.Make : Apex from Asian Paints orequivalent in All Guard from Berger,Weather Shield Max Exterior Acrylic from ICI Dulux |
| 84 | M&L Preparation of new wooden surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 85 | M&LPreparation of new surfaces of steel, of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 86 | Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed. |
| 87 | Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm complete all as specified and directed. |
| 88 | S&F CPVC pipes, SDR 11, 16 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow ,Tee, bends, unions ,sockets , male and femaleThreaded Adoptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceilingwith all clampsin Shafts/ducts with all necessary scaffolding to fix the pipes andtesting the joints under prescribed pressure etccompleteall as specified and as directed. |
| 89 | S&F CPVC pipes, SDR 11, 20 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow ,Tee, bends, unions ,sockets , male and femaleThreaded Adoptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceilingwith all clampsin Shafts/ducts with all necessary scaffolding to fix the pipes andtesting the joints under prescribed pressure etccompleteall as specified and as directed. |
| 90 | S&F CPVC pipes, SDR 11, 25 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow,Tee, bends, unions ,sockets , male and femaleThreaded Adoptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceilingwith all clampsin Shafts/ducts with all necessary scaffolding to fix the pipes andtesting the joints under prescribed pressure etccompleteall as specified and as directed. |
| 91 | S&F in repairs 15mm bore CPbib tap fancy type with crutch or butterfly handle, screwedfor iron pipe or for unions and fixed complete all as specified and directed. |
| 92 | S&F 15mm boreCP brassbib tap Two wayfancy type with crutch or butterfly handle, screwedfor iron pipe or for unions and fixed complete all as specified and directed. |
| 93 | S&F in repairs 15mm borestop valve / angle cockfancy type cast copper alloy chromium plated with capstan head serewed down iron pipe complete all as specified and directed. |
| 94 | All as per Item No.93 above,but fancy type, chromium plated with long shank and cup (concealed type) complete all as specified and directed. |
| 95 | S&F15 mm dia angle cockCP brass fancy type cast copper alloy chromium plated with capstan head serewed down foriron pipe fixed complete all as specified and directed. |
| 96 | S&F Wash down water closet (pedestal pattern) white and including plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or aluminium hinging device (excludingflushing cistern ) etc complete all as specified and directed. |
| 97 | S & F in repairs PVC 10 ltrs capacity symphonic action type low level flushing cistern including flush pipe, cantilever brackets incluiding taking down existing cistern etc complete fixed in repairs complete all as specified and directed. |
| 98 | S&F Vitreous china wash basin, white, flat back, size 580mm X 450mm including CI brackets, 32mm dia brass chromium plated waste fittingswith long screwed shanks and fly nuts flanged end bedded in red lead cement and other end fixed with & including cutting for & pinning in end of brackets and 15mm bore pillar tap, cast copper alloy fancy type chromium plated, screwed down high pressure complete all as specified and as directed. |
| 99 | S&F in repairs 125 mm size shower rose, chromium platedwith or without swivel joint including fixing to steel pipe or union etc.complete all as specified and directed. |
| 100 | S&F PVC connections, 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 101 | S&F in stainles steel sink with drainage board ,1 mm thick sheet of steel grade AISI 304 for kitchen or laboratory, with plug, waste pipe, washers and wastes including bedding in cement morter to dwarf wall or including fixing CI cantilever bracket, connecting union to pipeetc., overall size 915 x 460 mm with bowl size 410 mm x 330 mm x 160 mm etc complete all as specified and directed. Make : Nirali, Bule star ISI marked.. |
| 102 | S & F repairs 600mmx 450mm bevelled edge miirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. |
| 103 | S&F in repairs stainless steel kitchen plate rack of size 90cm X120cm X 1mm thick (18 gauge)conforming to the sample kept in the office of the AGE B/R I, complete all as specified and directed. |
| 104 | Dismantling / taking down PVC/ Cast iron soil /waste pipes 100 mm / 75mm bore including all fitting like bendsetc complete all as specified and directed |
| 105 | S & F 110 mm bore PVC (SWR)single socketed in any length with rubber ring joints as soil, waste and vent pipes laid in floors or trenches complete all as specified and directed |
| 106 | S & F 75 mm bore PVC (SWR)single socketed in any lengthwith rubber ring joints , complete fittings etc fixed to walls with using MS clamps8 mm dia with two nuts wall nails etccomplete all as specifed and directed. |
| 107 | S&F PVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4) & including removing old trap and fixing ofstainless steel grating in ground shape etc complete all as specified and as directed. |
| 108 | S&F 110 mm dia PVC (SWR) junction single (single T or Y) equal or unequalwith access doors complete all as specified and as directed. |
| 109 | S & F 110 mm bore PVC (SWR) plain bends, any radius complete all as specified and as directed. |
| 110 | S&F 110 mm dia vent cowl PVC (SWR) complete all as specified and as directed. |
| 111 | S&F 20mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high-density plastic ball screwed for iron pipe (minimum weight 210 grams) complete all as specified and as directed |
| 112 | Taking down existing unserviceable point wiring of any description/type/ size of light/ fan/tube/power/two way/bell point etc on TW batten/conduit includingremovalof batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified. |
| 113 | Taking down old unservicieble existing submain wiring of any size and type complete all as specified and as directed. |
| 114 | Disconnecting and removing MCB DBs and AC box from any height stripping out the fitting for examine replacement of un serviceable spare parts,reassembling,refixing in original position including minor repairs for the smooth functioning and testing complete all as specified and as directed. |
| 115 | M&L Providingpoint wiring of any length with using 1.5 Sqmm (nominal area) single core PVC insulated unsheathed cable up to 1100 V grade FRLSH conforming to IS - 694 multistranded maintaining colour code drawn through and including non metallic PVC conduit (medium grade) with appropriate size with all conduit fittings (ISI marked) suitable for surface wiring on brick masonry walls including new sunk type pressed steel terminal boxes grouting on wall of adequate size with suitable modular cover plate for mountingmodular switches,sockets regulators etc complete with all fittings and accessories fixing on wall/ceiling and drawing continuous earthwire with one run of1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLSH multistranded copper conductor as earth wire and connecting to common earth dolly for one light/Bell point controlled by one, one way switch 5 amps, SP and making good the disturbed wall surfaces to match with the existing surfaces complete all as specified and as directed for the following :-Note: Modular cover plates with frame and modular metal flush box shall be deemed inclusive in the unit rate quoted. |
| 116 | All as per Item No.115 above, butone ceiling fan/exhaust fan point controlled by one,one way switch and regulator |
| 117 | All as per Item No.115 above, but one 3 Pin 5 Amps switch socket outlet point controlled by one switch on Independt board. |
| 118 | All as per Item No.115 above, butone 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 119 | All as per Item No.115 above, but using 2.5 Sq mm FRLS single core copper conductor cable of multistranded PVC insulated unsheathed 1100 Volts grade for5 pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 120 | S & F Modular switch 1 way, 10 A, 1 Module capacity 230 volts complete all as specified and directed. |
| 121 | S & F Modular switch 1 way, 16 A, 1 Module capacity 230 volts complete all as specified and directed. |
| 122 | S&F Modularsocket outletmultipurpose 5 Pin, 6 amps, 230 volts combined 2 Module complete all as specified and directed. |
| 123 | S&F Modularsocket outletmultipurpose 6 Pin, 6/16 amps, 230 volts combined 2 Module complete all as specified and directed. |
| 124 | S & F Modular ceilingfan regulator for compactbility with BLDC ceiling fans,5 stepped type heavy duty suitable to work on 230 volts, 2 Module complete all as specified and as directed. |
| 125 | S&F Modular Bell Push ,10 Amps, 1 Module complete all as specified and as directed. |
| 126 | S&F Calling bell working on 230 volts AC,single phase complete all as specified and as direced. |
| 127 | S & F Ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and as directed. |
| 128 | M & LSubmain wiring with two runs of single core 4 Sq mm FRLSH PVC insulated copper conductor multistranded 1100 Volts grade drawn through andincluding rigidPVC conduit and concealed conduit accessories of suitable dia medium grade including running up of one run of4 Sq mm FRLSH copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly completeincludingremovingtheexistingunserviceablesubmain wiringandmakinggood thedisturbed surfaceto match with the existing complete all as specified and as directed. Note. Three runs of 4 sqmm cable, and one run of conduit shall bemeasured and paid as one unit length. |
| 129 | S & F 22/20 watt wall mounted indus plus LED batten with LED lamp,extruded aluminium heat sink provided for efficient heat dissipation & interated electronic driver, 230 volts bipin holders, diffused type connetor block internally prewired etc with 2 Nos PVC round blocks for mounting arrangements including all accessories with new 3 coremulti stranded copper conductor of size 23/0.193 from ceiling rose to fittingcomplete all as specified and directed. |
| 130 | S & F 12/10 watt wall mounted indus plus LED batten with LED lamp,extruded aluminium heat sink provided for efficient heat dissipation & interated electronic driver, 230 volts bipin holders, diffused type connetor block internally prewired etc with 2 Nos PVC round blocks for mounting arrangements including all accessories with new 3 coremulti stranded copper conductor of size 23/0.193 from ceiling rose to fittingcomplete all as specified and directed. |
| 131 | S & F LED light fitting 1x10W bulk head luminaires,230V,AC,IP65/66 protection includingconnecting up with three core flexible copper conductor cable of suitable size. complete all as specified and directed. |
| 132 | S&F LED security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 133 | S &F Sheet metal enclosure MCBDB SPN 8 way with suitable rated bus bar 240 Volts double door with magnetic locking system complete all as specified and as directed. |
| 134 | S &F Sheet metal enclosure MCBDB SPN 4 way with suitable rated bus bar 240 Volts double door with magnetic locking system complete all as specified and as directed. |
| 135 | S&F MCB, SP 6-32 Amps, 240 volts of rupturing capacity 10 KA, \"C\" series complete all as specified and as directed. |
| 136 | S&F MCB, SPN 32Amps, 240 volts of rupturing capacity 10 KA, \"C\" series complete all as specified and as directed. |
| 137 | S & F Sheet metal enclosure vertical type MCCB DB TPN 4 way double door with suitable rated bus bar 415 Volts suitable for and including MCCB TPN as incomer with suitable rated copper bus bar with netural link including provision for 100 Amps MCCB 25KA TPN as incomer and SP/TP MCBs a outgoing and total number of modules equal to MCCB TPN + 12 with blanking plates and fixed flush to wall and making good the distrubed surfaces etc. complete all as specified and as directed. Note :- MCB SP /TPN will be measured and paid seprately |
| 138 | S & F in repairs MCCB,100 Amps,25 KA for VTPN DBs complete all as specified and as directed. |
| 139 | M&L Earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanisediron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plateof SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed.NOTE: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate inpit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways,CI cover with CI frame hinges, galvanised iron funnel with watering pipe, wire mesh, complete. |
| 140 | Taking down ceiling fans 1200 mm sweep and exhaust fan 200/450 mm sweep,wall mounted fan remaining/cleaning of dust properly cleaning, greasing& overhualing of bearings including refixing and connecting up all as directed by Engr-in-Charge. Note : Replacement of defective/worn out parts will be measured & paid for separately |
| 141 | S&F in repairs capacitor 2/2.5 mfd as directed (Make - Asian/Usha/Epcos of siemens) complete all as specified and directed. |
| 142 | S&F in repairsball bearing of exsiting ceiling fans complete all as specified and directed. |
| 143 | S & F in repairstwisted three core copper flexible cable of size 1.5 sqmm from connector to the ceiling rose complete all as specified and directed. |
| 144 | S & F in repairs‘U’ clamps complete with nut, bolts & split pins Heavy duty, suitable for existing ceiling fan complete all as specified and directed. |
| 145 | S & F in repairsM.S. rod for ceiling fans 5 ft long with ‘U’ clamp at one end other end with out nut bolts washers or screwed thread with check nuts & pin complete. |
| 146 | S & F in repairsNut of bolts washers for fan blades fixing of ceiling fan of any make/size/type as per site requirement (6 Nos for each set) complete, a suitable for existing ceiling fan on site complete all as specified and directed. |
| 147 | M & LRewinding of stator complete with super enameled copper wire of gauge/ weight of copper coil, quick varnishing oiling, greasing insulating materials including replacement of worn out parts like u/s cotter pin, nut, screw, check nuts and bolts as required including cleaning of body and testing of the size 1200 mm sweep ceiling fans and 200/450mm exhaust fans of any make/model complete all as specifed and directed.Note :- Sapre parts except mentioned above and rewinding to be replaced will be measured and paid seprately under respective items of schedule. |
| 148 | M & L Spray painting of two coats of synthetic enamel paint on ceiling/exhaust fans of any sizecomplete all as specified and directed by Eng-in-charge. |
| 149 | S&F Ceiling fans 1200mm sweep with three blades, squirrel cage induction motor, down rod, hooks and other accessories, 230V, with new 3 coremulti stranded copper conductor of size 23/0.193 from ceiling rose to fittingcomplete all as specified and directed. |
| 150 | S&F Exhaust fan steel body, 300mm sweep ,1200 RPM, with blades,frame and louvers AC,single phasecomplete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail