|
| 1 | NOTE: Schedule ‘A’ Part I to XIII under Ser No. 1.00to 13.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only. |
| 2 | Lump sum price worked outfor BUILDINGS/ STRUCTURES as listed in Sch \"A\" Part I. |
| 3 | Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch \"A\" Part II |
| 4 | Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch \"A\" Part III |
| 5 | Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch \"A\" Part IV |
| 6 | Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch \"A\" Part V |
| 7 | Lump sum price worked out for ROAD/ PATH as listed in Sch \"A\" Part VI |
| 8 | Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch \"A\" Part VII |
| 9 | Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch \"A\" Part VIII |
| 10 | Lump sum price worked out for AREA DRAINAGE as listed in Sch \"A\" Part IX |
| 11 | Lump sum price worked out for DEMOLITION as listed in Sch \"A\" Part X |
| 12 | Lump sum price worked out for LIGHTENING PROTECTION as listed in Sch \"A\" Part XI |
| 13 | SCHEDULE \"A\" PART - XII MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6. |
| 14 | INTERNAL ELECTRIC SUPPLY |
| 15 | S & F for wall mounted LED box type tube light fitting 4\" x 20 watts industrial commercial interior batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 16 | Supply and fixing LED light fitting with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver and LED lamp 5700K Rated CCT energy efficientwith lumen efficiency corrosponding to five star BEE rating published for year of installation, pf 0.8, colour rendering index not less than 70%, IP20,with warranty option of 5 years from date of installation complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as directed. |
| 17 | Supply and fixing LED 10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size,with warranty option of 5 years from date of installation complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as directed. |
| 18 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for Bldg security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired andnecessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fittingwith warranty option of 5 years from date of installation including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed. |
| 19 | S & F for sheet metal enclosure MCBDBVTPN6 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system vertical type including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 20 | S & F for ceiling fan, 230 Volts, 1200 mm sweep with mian air delivary 210 CFM, service value of the fan shall be greater than 6.1 (5 star rated) as per BIS with blades, down rod & other necessary accessories with brushless direct current motor (BLDC)with remote system and electrical connections from ceiling rose to fan teriminal complete all as specified and directed. |
| 21 | S & F for energy efficient exhaust fan of 225 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing wall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). |
| 22 | Material and labour for maintenance free Chemical earthing of technology with copper bonded steel rod 3 mtr long 25.0 mm dia with 250-micron Copper bonded coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed.Note:-(i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 (ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 01.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. |
| 23 | DEMOLITION |
| 24 | Taking down existing old unserviceable point wiring of any type including switches, sockets, ceiling roses, fan regulators, light fittings complete all specified and as directed. |
| 25 | Taking down existing old unservicable Main Switches, DBs, meter box, Metal Clad sockets including MCB SP/SPNcomplete all specified and as directed. |
| 26 | Taking down existing old unserviceable Switch Socket, Celling Rose& Fan Regulator complete all specified and as directed. |
| 27 | Taking down existing old unservicable Main Sub Main wiring of any size/type complete all specified and as directed |
| 28 | Taking down existing old Tubes \"medium grade\" GI pipe galvanised with all fittings laid in trenches having bore size of any sizecomplete all specified and as directed. |
| 29 | Taking down existing old Gun-Metal,globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed for complete all as specified and directed. |
| 30 | Taking out old existing LT Panelofany type complete all specified and as directed. |
| 31 | Dismantling old existing steel poles/ Struts of any sizecomplete all specified and as directed. |
| 32 | Taking out old existing LT cable of any sizecomplete all specified and as directed. |
| 33 | REFRIGERATOR AND AIR CONDITIONING |
| 34 | Supply & Installationof Split type AC unit indoor/ outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangements and Digital Inverter twin rotary of capacity 1.50 TR all including mounting bracket for outdoor unit, suitable size of copper piping from indoor to outdoor unit, and pressure testing with nitrogen and freon gas vaccumising the system and charging the Non CFC refrigerentand testing the complete system for smooth functioning of split AC up to satisfactioning, 5 star rating, workingwith Non CFC refrigerent and provn of suitable size electrical connection from indoor to outdoor unit including necessary cutting on wall for copper piping and make good with putty/ cement and painting etc complete as specified and directed |
| 35 | Supply & Installationof Split type AC unit indoor/ outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangements and Digital Inverter twin rotary of capacity 2.0 TR all including moutning bracket for outdoor unit, suitable size of copper piping from indoor to outdoor unit, and pressure testing with nitrogen and freon gas vaccumising the system and charging the Non CFC refrigerentand testing the complete system for smooth functioning of split AC up to satisfactioning, 5 star rating, workingwith Non CFC refrigerent and provn of suitable size electrical connection from indoor to outdoor unit including necessary cutting on wall for copper piping and make good with putty/ cement and painting etc complete as specified and directed |
| 36 | Supply and install for Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 5.0 KVA complete all as specified and as directed. |
| 37 | AREA DRAINAGE |
| 38 | Supply and fixing Precast RCC drain alongwith cover, M-40 grade of internal size 450mmx450mm, each piece of drain of length 2.00 metre jointed and pointed in CM 1:3 as in covered drain complete all as shown on drawingcomplete all as specified and directed. |
| 39 | ROAD/ PATH |
| 40 | Material and labour for providing and painting 2.5 mm thick road marking strip (retro reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser,propane tank heater and profile shoe heater, driven by experienced operator on road surace including all cost of material, labour, T&P, cleaning of road surface of dirt, seals, ils, grease and foreign material etc. complete all as specified and directed. |
| 41 | EXTERNAL ELECTRIFICATION |
| 42 | M & L for boring under road with trench less tecnology forroad crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by hydrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, for GI pipe light grade of size up to 100 mm dia lof in any length any grade including for housing LT/ HT UG cables and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed.Note :- GI protection pipe shall be measured and paid separately |
| 43 | Disconnecting of 11 KV/ 433 Volts transformer of capacity 200 KVA out door type including all necessary HT/ LT connections of bothside, earth teriminals and taking down carefully from Pole structure/ Platform mounted on PCC foundation etc and shifting to a new location includingnecessary electrical reconnections of both HT/ LT side, cable connection, control cable connection to the tansformer and testing and commission complete all as specified and as directedNote:- (i) The rate quoted is deemed to be inclusive of necessary crane/ vehicle charges for shifting and installation of the transformer from old location to new location. |
| 44 | M & L for Construction of Plinth of size 3.0mx 3.0mx1.5m above ground level for transformer, using 100 mm thick PCC 1:4:8 type D-2 as in lean concrete, brick masonry in CM 1:6, the top of the plinth shall consist of 100 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) over 75 mm thick PCC 1:4:8 type D-2 over compacted moorum filling, 10 mm thick rendering in CM 1:4 on brick surface with and including 25 cm thick stone aggregates of size 12.5 mm all around upto and including 1.5 m from the edge of the plinth including provision and embedded in top portion of PCC with2 Nos of ISMB 100 mm channel painting with 2 coat aluminiumpaint over a coat of red oxide primer and 3 coats of white washing on cement workfor fixing transformer including ramp of suitable size for mounting of transformercomplete all as specified and as directed. |
| 45 | Supply, installation, Testing and commissioning of Outdoor type (IP 3X), 03 way RMU (Ring Main Unit) 11 KV, 630 Amps, 21kA-3 Sec,IP 3X SF6 insulated, One side Extensible,consisting of Two Nos (02) motorised vacuum circuit breaker (Incomer) and One No (01) motorised vacuum circuit breaker (Outgoing) & Metering Panel Bus PT with Top LV, Battery & Battery charger, Ethernet switch & LIU (Configuration VVV+M), inside robotically welded stainless steel 304 (Non Ferrite non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manager voltage surges and Air Insulated Metering Module of Class-1. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions & complete with all accessories. The complete RMU must be type tested for Internal arc25KA for 1 sec with AFLR Classification for Gas tank & Cable Chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must RMU manufacturer\"s own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protectioncomplete all as specified and as directed. The unit shall include the following with all necessary standard fitting as required at site.- |
| 46 | Make of RMU shall be limited to : ABB/ SIEMENS/ SCHNEIDER INFRASTRUCTURE(Channel partner/ System Integrator/ Authourized Partner/ License partner make RMU shall not be accepted.)Note:(a) Vacuum Circuit Breaker consist of following accessories :-(i)Microprocessor based Numerical Protection Relay for Circuit Breakers - REF615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 67, 67N, 32, 27, 59, 25, 81U, 81O, 95 Measurement for 3I,I0,3U,U0,Kw,KVA,PF,Hz,Kwh, 16 DI + 10 DO, One front RJ45 Port, One Rear RJ45 Port for IEC-61850 Protocol, Drawout Type with CT Shorting feature, Graphical LCD Display(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator on the gas tank.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO amd suitable for 10,000 mechanical operation.(v)CT shall be minimum 50/1A ,2.5VA , 5P10 - 3 Nos. for protection(vi)CT shall be minimum 50/1A ,2.5VA , Class 0.5 - 3 Nos. for metering(vii)Right angle boot to be provided in each module |
| 47 | (viii)2 x12 Volts, 26 AH Battary with Charger - 1 Set(ix)Bus VT shall be 11KV/V3/110V/V3 ,20VA , Class 0.5 - 3 Nos. for metering(x)Auxiliary VT shall be 11KV/230 ,500VA for AC supply input to Battary Charger.(xi)Capacitive voltage indication fixed type system as per IE(xii)Interlocked Cable box for front termination of the cable suitable upto 3 core 120 Sqmm,11 KV XLPE cable (IP3X). Safety interlocked to prevent access to cable termination in live-condition. (xiii)Right angle boots (push on type)(xiv)Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB.(xv)Necessay interclocking arrangement for safety and operations(xvi)One No. Operationg Handle for Manual Operation and one no. manometer(xvii)Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions.(xviii)Above switchgear shall confirm to all relevant IEC/IS Standards.NOTE :-(i)Foundation of RMU as per manufacturer recommandation andCost of PCC foundation up to height 1 Mtr from GL is deemed to be included in the quoted rate . |
| 48 | Supply, installing, testing and commissioning of factory made Type Test Assemble (TTA) APFCPanel wihth MPP-H capacitor and suitable capacity MCCB as incommer, Outdoortype floor mounted,suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated. The panel shall be dust and vermin proof, IP 65 class protection and made of3.15 mm CRCA MS sheet and 50 x 50 x 5mm thick MS angle iron base frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,both side openingtype, with aprons for cable entry,with double door shutter and locking arrangement having suitable capacity of copper bus bar sizefour strips, 415 Volts consisting with heavy duty MPP capacitor bank70 KVAR with 7 steps (1x 20 KVAR + 4 x 10 KVAR + 2 x 5 KVAR)complete all as specified and as directed. Note:- (i) Compact modular bolted design, removable side and back panels with option of top and bottom cable entry(ii) Capacitor installed in removable assemblies for ease of operation and maintenance(iii) MCCB TPN of suitable capacity with25 KA breaking capacity with high electrolytic grade copper bus bar of suitable rating.(iv) Capacitor with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating current of each capacitor suitable for each control . ( each capacitor bank equipped with discharge resister) & 7% detuned harmonics filter reactor. |
| 49 | Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:-Note:-(i)Design of LT Panel including components, layout, their design as per IEC-61439 duly certified by ASTA or other approved agency.(ii)OEM design & GA drawingshall be submitted to GE for approval before start the manufacture(iii)Factory inspection for routine test/ type test as requiredshall be carried out by Rep of accepting officer before dispatch from factory. Testing charges shall be included in the quoted rates of item.(iv) Make ofFactory made TTA Panelshall be limited to : ABB/ SIEMENS/ SCHNEIDER/L&T/ C&S INFRASTRUCTURE(Channel partner/ System Integrator/ Authourized Partner/ License partner shall not be accepted.) |
| 50 | INCOMING:-(a)Copper strip busbar of 800 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos(b) MCCB 400 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 35 KA breaking capacity including all fixing accessories with both ends spreader link- 01 No (Incoming) (c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three) (d)Digital Ammeter of range (0- 400) Amps, flush mounting type with suitable CT’s of ratio and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. |
| 51 | OUT GOING:-(a)MCCB 200 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader link- 01 No(b) MCCB 160 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No(c)MCCB 125 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader link- 02 Nos (01 No spare)(d)MCCB 63 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader link- 01 No(e) MCB TPN 32 Amps 4 pole, 415 Volts, 10 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No (f) Power Contractor 32 Amps, 3 Pole 415 volts- 01 No(g)Astronomical function Time switch (suitable for Vadodara, Gujarat area)- 01 No(h)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of LT Panel -01 No. |
| 52 | M & L for Street light fitting bracket made out from GI Pipe 50 mm bore (dia), medium grade 1.50 metre long, bent to required shape and fixing to Poles with and including Clamp sets suitable for tubular pole made out of MS flat iron of size 40 mm x 6 mm thick, Nuts, Bolts as required duly painted with two coats of Aluminum Paint over a coat of Red Oxide Zinc Chrome Primer comlete all as specified and as directed.Note :- Cost of Mild Steel Clamp, Nuts, Bolts and painting is deemd to be included in the quoted Unit Rate. |
| 53 | S & F for Security light junction box of size 205 x 255 x 112 mm for luminaries, weather proof made out of polycorbonate housing fire retardant, non fusing, shock & rust proof, single piece moulded andcover with hinged door, pole/ wall mounting type comprising of MCB SP 10 Amps,fixed on PCC foundation with screws complete all as specified and as directed. |
| 54 | S & F for LED Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 protection security/ street light fitting luminaire of capacity 80 watts with high power LEDs as light source and electronic driver, 4 kV inbuilt and 10kV external surge protecton with Top opening driver cover for easy maintenance with warranty option of 5 years from date of installation with pre wired andnecessary mounting arrangements and provision of 4 sq mm three core copper conductor cable multi stranded from fitting terminal to street junction box complete all specified and as directed |
| 55 | EXTERNAL WATER SUPPLY |
| 56 | Supply, Laying, jointing & testing of Ductile iron (DI) of size 100 mm dia, pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer ofepoxy paint in outer side,suitable for push on joint(rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillarcomplete all as specified and as directed.Note:- (i) Excavation & Earthwork, shall be measured and paid separately.(ii) The quoted rate shall also be deemed to include for provision of joints and jointing material for laying pipes. For jointing ofpipe fittings or taking branch connection, provision of joints and jointing material shall be measured and paid separately.(iii) . Before laying of pipe line contractor has to submit layout diagram as per level difference and ensure proper alignment of the pipe. |
| 57 | M&L for Ductile iron fitting for spigot socket pipe such as bends (any type, radius and angle) tapers any type (straight, bend increasing, decreasing or double socket etc). Tee pieces single branch. \"Y\" junction, double branch, cross (All socket or socket and spigot) collars, restrained joint, mechanical joint, caps & plugs 80 mm to 250 mm dia bore including cutting and jointing new positions complete all as specified and as directed |
| 58 | Material and labour for construction of brick masonry valve pit of internal size 90cm x 90cm x 90cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation |
| 59 | SHIFTING OF AF NET CABLE |
| 60 | Supply, laying and testing OFC Cables 48 core armoured in trenches complete all as specified and as directed |
| 61 | Supply , Laying and testingJFC Cables up to 200 pair in trenches complete all as specified and as directed |
| 62 | M & L for cable chamber circular 1.0 mtr dia 2.0 mtr depth made out ofHume pipe NP -2 with cover complete all as specified and as directed |
| 63 | M & L for Concrete pipe for crossing of JFC cable 12\"\" dia complete all as specified and as directed |
| 64 | S & F for Joint enclosures for OFC/JFC cable complete all as specified and as directed |
| 65 | S & F for Jointing kit for OFC cable complete all as specified and as directed |
| 66 | M & L for 1000 Pair MDF Box complete all as specified and as directed |
| 67 | M & L for Spilicing and Jointing of OFC & JFC cable as required complete all as specified and as directed |
| 68 | NOTE : Amount of credit of Rs. 4,17,323.00 for retrieved materials is mentioned in schedule of credit on Srl Page No. 49 of tender documents in pdf form which will be deducted offline while acceptance of tender. |