| 1 | Excavating in post holes (or similar holes) each n exc0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in SOFT/LOOSE soil complete, all as specified. |
| 2 | Cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate), finished even & rough, as in foundation filing and mass concrete, complete all as specified. |
| 3 | Rolled mild steel work as in tubulartrusses including special shaped washer etc using ERW or induction butt welded tubeconformingto IS 1161-1979 grade St -240 complete all as specified. quality-A complete all as specified |
| 4 | Mild steel work plates ( plain or chequered) channels, squarecut or notched (ordinary and counter sunk) forming holes without any attachmentconfirming to Fe-410 -Gde E-250,quality-A complete all as specified |
| 5 | Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with tinned tacks or steel wire staples all as specified. |
| 6 | 04 levers brassmortice lock, vertical type, 100 mm size, with 2-3 keys, complete all as specified. |
| 7 | Double action floor door spring, hydraulically regulated, made of 1.25 mm thick aluminium alloy sheet, foundation box main body with stainless steel cover, governing pivot made of brass, rest of part made out of heavy duty mild steel, ISI marked, complete. |
| 8 | Powder coated aluminium frame for doors, windows, ventilators, fixed glazing with one or more rebates including joining cleat for fixing, fixed to opening with suitable size steel screws and rawl plugs etc., (aluminium section not less than 2 mm thick) complete all as specified.NOTE:- Minimum thickness of powder coating shall be 50 micron. |
| 9 | Powder coated aluminium door shutters (Aluminium section weighing 0.55 kg/m) with styles & rails , anodised alumnium glazing snap beading, rubber neoprene packing including joining cleats &screws etc as per manufacturers instructions, complete all as specified. NOTES: (a) Each shutter shall have2 Nos. 200 mm long almn handles and 03 No. 100 mm size stainless steel/almn butt hinges.(b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ.(c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron. (d) Aluminium section weighing 0.55 kg/m |
| 10 | Powder coated aluminium window and ventilator shutters (Aluminium section weighing 0.55 kg/m) side hung type with styles & rails , anodised alumnium glazing snap beading , rubber neoprene packing including joining cleats &screws etc as per manufacturers instructions, complete all as specified.NOTES:(a) Each shutter shall have2 Nos. 125 mm long almn handles and 02 No. 75 mm size stainless steel/almn butt hinges & one no. almn hook & eye.(b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ.(c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron. |
| 11 | 6mm thick asbestos cement corrugated or semi corrugated sheet in roof, walls, fixed with L type or J type or cranked hook boltscomplete all as specified. |
| 12 | Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel withconnecting clips across the intermediate channel at 457 mm centre to centre, complete all as specified. |
| 13 | Seamless calcium silicate ceiling made out of 12 mm thick1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish, complete all as specified.NOTE: Frame work & hangers for ceiling shall be measured and paid separately) |
| 14 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., and brushing a coat of cement slurry with 3 kg of cement per Sq.m, complete all as specified. |
| 15 | Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.18 Sq.m but n. exc. 0.38 Sq.m,laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:6), complete all as specified. |
| 16 | Sheet glass 4 mm thick ordinary quality and glazing with oil putty or aluminium beads in squares n. exc. 0.5sqm in each pane complete all as specified. |
| 17 | Sheet glass 4 mm thick ordinary quality and glazing with oil putty or aluminium beads in squaresexc. 0.5sqm in each pane complete all as specified. |
| 18 | Sheet glass 5.5 mm thick ordinary quality and glazing with oil putty or aluminium beads in squares n. exc. 0.5sqm in each pane complete all as specified. |
| 19 | Two coats of synthetic enamel paint over & including a coat of red oxide primer oversteel & iron (new) surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified. |
| 20 | Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal modular boxes made out of 1.2mm thick MS sheet concealed in wall modular metal flush box & including modular cover plate with framehaving necessary cutting for fixing switches/ socketscomprising the following: - |
| 21 | One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 22 | One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified. |
| 23 | One Socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 24 | One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 25 | NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule \"A\". (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4). |
| 26 | Switch modular type single pole one way, 6 Amp, 1 module complete all as specified. |
| 27 | Switch modular type single pole one way, 16 Amp, 1 module complete all as specified. |
| 28 | Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, 2 Module complete all as specified. |
| 29 | Socket outletmultipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp,2 Module complete all as specified. |
| 30 | Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified. |
| 31 | Sub main wiring 2 runs of 4 Sq. mm main cable + 1 run of 4 Sq. mm earth cable (with approved colour coding as per IS) with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing in conduits, with and including rigid non metallic PVC medium duty concealed conduit not less than 25mm dia complete all as specified for the following: - NOTES: (i)For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as \"1 RUNNING METRE\" |
| 32 | Sheet metal enclosure SPN, 4 way with 200 Amp rated bus bar, 240 V, double door type for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting,complete all as specified comprising the following: |
| 33 | Sheet metal enclosure SPN, 8 way with 200 Amp rated bus bar, 240 V, double door type for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting,complete all as specified comprising the following: |
| 34 | Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amp, 240 volt, breaking capacity not less than 10 kA, complete all as specified. |
| 35 | MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, \"C\" curve type of rating6 to 32 Amp,complete all as specified. |
| 36 | MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, \"C\" curve type of rating 32 Amp complete all as specified. |
| 37 | MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, \"C\" curve type of rating 40-63 Amp complete all as specified. |
| 38 | Hi wall split units indoor / outdoor complete with cordless remote control unit invertar type and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating cooling & heating function and EER 3.2 of capacity 1.5 Tonand mounting accessories kit with stand complete all as specified. |
| 39 | Surface mounted Environment friendly LED batten with powder coated aluminium housing with intigrated electronic driver with THD<10% LED 20 W lighting fixture with extruded polycarbonate, 6500K, lumen output should not be less than 90 lumens per watt,IN REPLACEMENT,completeMAKE: Havells Cat No. LUMILINESMART20WLED865PCWHor equivalent in makes mentioned in Appendix \"B\" |
| 40 | Flame proof point wiring with using approved colour coding as per IS, with Zero halogen flame retardent (HFFR), smoke free, non toxic, non corrosive installation cable1.5 Sqmm nominal area HFFRinsulated unsheathed multistranded copper conductor cable in and including ERW rigid conduit stove enamelled surface conduitfor one light point / Fan point / 6Amp multipurpose switch socket with and including necessary conduit acessories like flame proof junction box(es), bend(s), reducer(s) and unions etc, independent for one light point controlled by one (MCB) including 1.5 Sqmm nominal area PVC insulated unsheathed multistranded copper conductor cable for earth wire to common earth and connected to earth dolly complete all as specified. |
| 41 | Flame proof point wiring with using approved colour coding as per IS, with Zero halogen flame retardent (HFFR), smoke free, non toxic, non corrosive installation cable 2.5 Sqmm nominal area HFFRinsulated unsheathed multistranded copper conductor cable in and including ERW rigid conduit stove enamelled surface conduitfor one light point / Fan point / 16Amp multipurpose switch socket with and including necessary conduit acessories like flame proof junction box(es), bend(s), reducer(s) and unions etc, independent for one light point controlled by one (MCB) including 1.5 Sqmm nominal area PVC insulated unsheathed multistranded copper conductor cable for earth wire to common earth and connected to earth dolly complete all as specified. |
| 42 | Flame proof weather proof rotary switch, single pole on & off with cable termination box in LM6, 16 Amp rating,ON/FF type, 230 volt AC certified by CMRS for Group IIA & IIB complete including compression glands complete all as specified. |
| 43 | Flame proof weather proof rotary switch-socket and plug combination in LM6, three pin (two pole earth) with cable termination enclosure box, 16-25 Amp rating, 250 volt complete. |
| 44 | Flame proof tube LED light fitting 2x 16 watt with & including LED tube 16W each, CMRI certified recommended suitable for gas/vapur of IIA & IIB and Zone 1& 2 havingIP-65 protection with die cast aluminium housing with heat resistant toughened glass with driver, holder, connector etc complete suitable for fixation on wall/roof including connecting up with three core suitable size twisted flexible copper conductor with complete. |
| 45 | Single phase two wire dual source prepaid energy meter BIS 15884 marked in existing meterboard/ floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from gridland DG, capable to define for tariff slabs, happy hours and holiday definition complete all as specified. |
| 46 | Excavation in trenches in SOFT/LOOSE soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, taking out/ laying pipe line, cable etc. and getting out complete, all as specified. |
| 47 | Returning filling in including spreading, levelling, watering and well ramming in layers notexceeding 25cm thick complete all as specified. |
| 48 | Removal of excavated surplus spoil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified. |
| 49 | Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified.NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment. |
| 50 | Brick protection with old size sub class \"B\" bricks laid flat across the route of underground cable all as specified and directed |
| 51 | Supply, laying, jointing & testing of LT XLPE insulated cable screened,bedded, galvanised steel strip or wire armourd cable(heavy duty) 1100 volt gradewith aluminium conductor conforming to IS-7098 (Part-I -1988)laid in trenches/ ducts/ through pipes/ in floors / underroads/ hard standing /along poles and testing complete all as specified of sectional area:- |
| 52 | 10 Sq.mm, 2 core |
| 53 | 50 Sq.mm, 3.5 core |
| 54 | Air termination, single pointed aluminium rod 12 mm dia 300 mm longcomplete all as specified. |
| 55 | Aluminium strip of size 25mm x3mm complete with saddles and fixing screws for fitting the strip |
| 56 | ESD table of size 6x6x3.5 ft with mat and strap complete all as specified and directed. |
| 57 | Magnifying glass table lamp with RoHS compliance 10 x magnifying adjustable swivel complete all as specified and directed |
| 58 | ESD smoke obsorber 240V 25 Watt Carbon filter with or without remote control with minimum dimension of 250 x 250 x 150mm complete all as specified and directed. |
| 59 | Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GIstrip 32x6 mm as earthing lead by means ofGI or steel bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mmbore GI light grade pipe for watering and including funnel, wire mesh, RCC cover, reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, using round bar, PGI funnel with wire mess & frame, PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I., complete all as specified. Note:- (i)PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.(iii) Earth resstance shall be less than 3 ohm. In case the test results are not found less than 3 ohm, complete earthing shall be redone by the contractor without any extra cost to Govt. |
| 60 | LT Panel Board factory made CPRI approved panel, weather, dust & vermin proof outdoor cubical compartmental type, double door, fornt and back side openable, with providing rubber/PVC gasket of suitable size all sides of door, with copper busbar wrapped with pvc tape/sleeves with maintained the colour code and copper strip busbar of suitable rating to MCCB input andMCCB output of suitable length, made out of 3.00 mm thick mild steel CRCA sheet with 40x40x6mm size angle iron supporting frame including applying two cats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 1.5 sqmm copper wire and connections of all outgoing/incoming including PCC foundation complete all as directed and specified installation, commissioning and testing and comprising of the following fitment accessories:-INCOMING(a)Copper strip busbar of current carrying capacity 400Amps wrapped with PVC sleeves with maintained the colour code and provision of making holes with copper nuts, bolts & washers for cable connections including hydorgrapic insulators with nuts & bolts at both ends = 04 Nos(b)MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=36 KA breaking capacity, rating 250 Amps, adjustable thermal magnetic type, thermal release r+B71ange (64 to 100%) with O/L, S/C protection including all fixing accessories with both ends spreader links -02 Nos(Make : Legrand/Scheider/L&T).(c)LED Neon indicator lamp (RYB) with holder, 230/250 volts, AC-01 Set (set of three) Make:- AE/L&T.(d)DIgital Ammeter of range (0-400) Amps, flush mounting type of size 100mmx100mm(4\"x4\") square dial withy CT\"s of ration 630/5 and selector switch-01 set(Make: Legrand/Schneider/L&T). |
| 61 | (e)DIgital Voltmeter of range (0-500 Volts, flush mounting type of size 100mmx100mm(4\"x4\") square dial with selector switch -01Nos (Make: Legrand/Schneider/L&T).OUTGOING(a) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=36 KA breaking capacity, rating 200 Amps, adjustable thermal magnetic type, with O/L, S/C protection including all fixing accessories with both ends spreader links -01 Nos(Make : Legrand/Scheider/L&T).(b) Spare Pocket for MCCB-02 Nos |