| 1 | Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames), complete all as specified and directed. |
| 2 | Taking down chowkats or frames with shutters (without taking of shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each, complete all as specified and directed. |
| 3 | M & L for Preparation of old painted steel surfaces of any description,over 10 cm width or girth and applying one coat of synthetic enamel paint (ordinary tint), complete all as specified and directed. |
| 4 | M & L for preparation of old woodenSurfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. |
| 5 | S&F of stainless steel curtain rod side brackets decorative type of approved quality, complete all as specified and directed. |
| 6 | S&F in repair 25 mm dia decorative typestainless steel and decorative type and cap/finial etc & all other connected works, complete all as specified and directed. |
| 7 | Dismantling of stone slabs and tiles of any description or thickness in floors aprons etc including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 8 | M & L for Granite18- 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including pointing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite flooringincluding 20 mm thick screed bedding in cement mortar 1: 6 and all other similar works, complete all as specified and directed. |
| 9 | S&F of 300mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed etc., complete all as specified and directed. |
| 10 | S&F of 125mm size Butt hinges, extruded brass, with brass hinge pin, bright pol ished and fixed, type B-11 etc, complete all as specified and directed. |
| 11 | S&F of 200mm long Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed etc., complete all as specified and directed. |
| 12 | S&F of 150mm long floor door stopper of brass body and tongue with hard drawn steel spring fixed in floor etc., complete all as specified and directed. |
| 13 | S&F of 150mm long Extruded brass handles, fabricated type polished etc., complete all as specified and directed. |
| 14 | M&L for preparing old wooden surfaces of any description not otherwise described over 10cm in width or girth and applyingone coat of synthetic enamel painting,complete all as specified and directed. |
| 15 | Taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster, complete all as specified and directed. |
| 16 | M&L for 15mm thick rendering in CM 1:6 on fair faces of brick work, surfaces finished even and fair without using extra cement, complete all as specified and directed. |
| 17 | M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work, with mixing WPC @ 3% by wt of cement surfaces finished even and fair without using extra cement, complete all as specified and directed. |
| 18 | M&L for rendering 5mm thick in CM 1:3 finished even and smooth with out using extra cement in ceiling, complete all as specified and directed. |
| 19 | M&L for preparation of new plaster surfaces of ceilingand applying two coats of oil bound distemper over one coat of primer including 1 mm thick wall care putty car, complete all as specified and directed by Engr-in-Charge. |
| 20 | M&L for preparation of new plaster surfaces of walls and applying two coats of oil bound distemper over one coat of primer including 1 mm thick wall care putty car, complete all as specified and directed by Engr-in-Charge. |
| 21 | M&L for Providing & applying anti algal water-based Elastomeric exterior wall finish on old as well as newly plastered surfaces including surface preparation, applying suitable wall Prime seal primer 8-10 Sqm per ltr coverage area and application of two coats (base coat 4.2 -4.7 & top coat 6-6.5 sqm per ltr coverage area ) & of paint by roller etc. complete. (Make- Dr Fixit Rain coat classic, Asian paints, Berger), complete all as specified and directed. |
| 22 | M&L for complete removing existing treatment on wall surface and applying two coats of oil bound distemper overover one coat of primer over 1 mm thick wall care putty, complete all as specified and directed by Engr-in-Charge. |
| 23 | Material and Labour for preparing newly & Old plastered surfaces of walls / ceilings by scrapping / rubbing and applying two coats of weather proof acrylic exterior paint (100% Acrylic)Base coat of Apex ultima protek duralife and top coat of Apex Ultima protek, Make : Asian Paints) over a coat of alkali resistent primer through authorized applicator onlyincluding use of scaffoldings from Ground floorupto 04 storeys height of bldgs bldgs, complete all as specified and directed.Make: \"Apex Ulitima\" of Asian Paints \"trucare\" Primer / \"Weather coat all Guard\"of Berger Paints /Dulux weather shield Max of Dulux Paints/Excel top Guard of Nerolac paints as approved by GE complete all as specifeid. |
| 24 | S & F of 12 mm thick plain toughened glass in doors/ windows framing doors handle, suitable hinges, rubber beading, floor spiring and all necessary fittings complete Including dismantling of old glass any type,complete all as specified and directed.Make- 1 Saint Gobin 2 Asahi 3 Atul Glass Industries 4 Golden Fish 5 Modi Guard 6 Hindustan Pilkington Glas.Note :- The desion drawing of necessary fittingS S in Doors/ Windowsapproved by GE. SS fitting will be measured & paid separately. |
| 25 | M&L for SS 316 grade stainless steel(Square/Round/Rectangular) of suitable gauge as in SS guard bars, railings, SS frame works as in windows, balcony, including all fixing arrangments, including taking down of old guard railing, complete all as specified and directed. |
| 26 | S & F for powder coated aluminium sections for doors, windows, ventilators, door partition including fabrication of frame shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc. including all accessories such as glazings clips, and rubber beadings for fixing glass panes in frame, complete all as specified and directed.Note : (i) Glass panes will be measured & paid separately . (ii)The quoted rate shall be inclusive of cost of rubber beading however it will be not be weighed and not paid separately.(iii) All other minor details including cost of locking arrangement shall be included in the quoted rate.(iv) Windows all around will be sealed with silicon sealant.Make : Hindalco/Indal (Indian Al Coy)/Jindal/Associated Profile & Aluminium Ltd/Ajit India. |
| 27 | S&F in repair for galvanised M S Wire cloth of 0.56 mm nominal dia of wire and average width of aparture 1.18 mm fixed with tinned tack for galvanized wire staple incl fixed in repair, complete all as specified and directed. |
| 28 | M&L for 5.0 mm thick sheet glass tinted colour frostedordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane, complete all as specified and directed. |
| 29 | S&F of sheet glass 4 mm, ordinary quality and glazing with oil putty in square & fixed with rubber beeding, complete all as specified and directed. |
| 30 | Demolition of Mud/mud puska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part there of), complete all as specified and directed. |
| 31 | M&L for cutting out cracks to v-section in existing roofs or terraciv cleaning grouting with cement and sand slurry 1:3, complete all as specified and directed. |
| 32 | M&L for cutting grooves in brick wall 75mm wide and 65mm deep & shaping horizontal face of groove with cement, complete all as specified and directed. |
| 33 | M&L for PCC 1:3:6 type B-1(using 20mm graded crushed stone aggregate) for providing cement concrete as levelling and roof kerbs or mud stops, including finishing the surface with grinder to receive the acrylic based water proofing material, rounded or chamfered on edges etc., complete all as specified and directed. |
| 34 | M&L for preparation of new surface andapplying a coat of hot blown bitumen of grade 85/25 conforming to IS 702 over primed surface of roof slab @ 1.20 Kg/Sqm, complete all as specified and directed. |
| 35 | M&L for applying one coat of aluminium paint at the rate of 100 gms/sqm as per manufacturers instructions over bituminous layer, complete all as specified and directed. |
| 36 | M&L for APP basedpolymeric water proofing membrane minimum weight 3.5 Kg/ Sqm and minimum 3mm thick reinforced with polyster non wove fabrick (Weight not less than 150gms/Sqm or as per IS),laid over hot bitumen surface by torched application with the strict supervision of manufacturers technical supervisor. Membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer, complete all as specified and directed. |
| 37 | M&L for renderingor bedding layer 15mm thick in cement mortar (1:3) cover concrete surfaces of roof, mixed with linesed oil @ 3% wt of cementinclduing finishing surfaces even and fair without using extra cement inclusive linesed oil, complete all as specified and directed. |
| 38 | Demolition of brickwork or stone boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed. |
| 39 | Brickwork with subclass \"B\" bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 of using class designation 100 of bricks in lieu of 75all as specified and as directed. |
| 40 | Dismentling of floor, hearth or wall tilingincluding cement mortar bedding (but not backing),complete all as specified and directed. |
| 41 | M&L for 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded crushed aggregate), complete all as specified and directed. |
| 42 | M&L for Non Skid ceramic coloured tiles 7 to 8 mm thickjoint free (square/ rectagular) area of each tile exceeding 0.06 sq m but not exceeding 0.11 sqm ,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade of tile and laid over and inclduing 15mm thick screed bed layer in CM (1:6), complete all as specified and directed. |
| 43 | M&L for Glazed ceramic tiles in vertical surface 600x 300x7 mmthick joint lesstiles set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade tile over and inclduing 10mm thick rendering in CM (1:4) complete etc. (1st quality/Premium Quality), complete all as specified and directed. |
| 44 | S&F in repair Aluminium die cast body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg, complete all as specified and directed. |
| 45 | Taking down carefully aluminium battenpoint, wiring for light/fan/socket/bell or power point including. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. Complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc including taking down old light fittings, complete all as specified and directed.Note :- (i)Contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fittings and fixture as directed and deposit in MES store yard. (ii)Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii)Decision of GE shall be final and binding in respect of serviceability of fittings/fixture. |
| 46 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor drawn through new PVC concealed conduit mediem grade, ISI markedand including provision of 1.5 sqmm PVC insulated copper cable FRLSH as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches , socket outlet and fan regulators etc, complete all as specified and as directed for the followings:- |
| 47 | (a)One light/fan/bellpoint controlled by one switch single pole one way, complete all as specified and directed. |
| 48 | (b) All as per item No 46.01here-in-before butone3 pin 6 amp switch socket out let independent, complete all as specified and directed. |
| 49 | (c) All as per item No 46.02 here inbefore but one 3 pin 6 amps socket outlet on the same board with other switch, complete all as specified and directed. |
| 50 | All as per item No 46.02 here-in-before but using 02 Nos. 4.0 sq mm size for main cable and 01 No.4 sq mm size as earth conductor for one 16 Amp switch socket outlet on independent board, complete all as specified and directed. |
| 51 | Supply and fixing of switch modular flush 6A single pole one way ISI marked, complete all as specified and directed. |
| 52 | Supply and fixing of modular sockets 6 Amp 2 in 1 2/3 pin combined, complete all as specified and directed. |
| 53 | Supply and fixing of switch modular flush type 15/16 Amp single pole one way 240 volt one module ISI marked, complete all as specified and directed. |
| 54 | Supply and fixing of modular sockets 16Amp 2 in 1 3/5pin combined, complete all as specified and directed. |
| 55 | Supply and fixing of Modular bell push flush type 5 Amps single pole 230 Volt white white finish, complete all as specified and directed. |
| 56 | Supply and fixing of ceiling rose surface bakelite 60x25mm three terminal, complete all as specified and directed. |
| 57 | Supply and fixing of electronic step type fan regulator 240 volt 50 Htz 120 watt (switch/sockets type in shape) modular type, complete all as specified and directed. |
| 58 | Supply and fixing in replacement white cover plate with frame one module for modular switches and sockets, complete all as specified and directed. |
| 59 | Supply and fixing in replacement white cover plate with frame two module for modular switches and sockets, complete all as specified and directed. |
| 60 | Supply and fixing in replacement white cover plate with frame three module for modular switches and sockets, complete all as specified and directed. |
| 61 | Supply and fixing in replacement white cover plate with frame four module for modular switches and sockets, complete all as specified and directed. |
| 62 | Supply and fixing in replacement white cover plate with frame six module for modular switches and sockets, complete all as specified and directed. |
| 63 | Supply and fixing in replacement white cover plate with frame eight module for modular switches and sockets, complete all as specified and directed. |
| 64 | Supply and fixing in replacement white cover plate with frame twelvemodule for modular switches and sockets, complete all as specified and directed. |
| 65 | Supply and fixing in replacement white cover plate with frame sixteen module for modular switches and sockets, complete all as specified and directed. |
| 66 | Supply and fixing in metal flush box 1/2 modul 1.6 mm for mounting modular switches and sockets, complete all as specified and directed. |
| 67 | Supply and fixing in metal flush box three module 1.6 mm for mounting modular switches and sockets, complete all as specified and directed. |
| 68 | Supply and fixing in metal flush box four module 1.6 mm for mounting modular switches and sockets, complete all as specified and directed. |
| 69 | Supply and fixing in metal flush box six module 1.6 mm for mounting modular switches and sockets, complete all as specified and directed. |
| 70 | Supply and fixing in metal flush box eight module 1.6 mm for mounting modular switches and sockets, complete all as specified and directed. |
| 71 | Supply and fixing in metal flush box twelve module 1.6 mm for mounting modular switches and sockets, complete all as specified and directed. |
| 72 | Supply and fixing in metal flush box sixteen module 1.6 mm for mounting modular switches and sockets, complete all as specified and directed. |
| 73 | Supply & fixing of MCB DB SPN 8 way, double door, IP-43, IK-09, Isolated Neutral Bar and fixed flush to wall and suitable for universal mounting, complete all as specified and directed. |
| 74 | Supply & fixing of MCB DB SPN 4 way, double door, IP-43, IK-09, Isolated Neutral Bar and fixed flush to wall and suitable for universal mounting, completeall as specified and directed. |
| 75 | Supply and fixing of MCB, single pole and neutral, 230 volts, 40 to 63 Amp rating, \"C\" series fixed in DBs catered here-in-before, complete all as specified and directed. |
| 76 | Supply and fixing of MCB SP 6-32 Amps 240 volts 10 KA 50 HZ \"C\" curve, complete all as specified and directed by Engineer in Charge. |
| 77 | Supply and Fixing of calling bell AC buzzer, complete all as specified and directed. |
| 78 | Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 4 sqmm FRLSH, 1100 Volts gradecable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLSH 1100 volts grade cable continuous earth wire of green colour code, complete all as specified and directed. Note:- (a) Two runs of4 sqmm cable and one run of 4 Sqmm cable as earth leadwith conduit shall be measured as one unit length for payment.(b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish. |
| 79 | Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLSH, 1100 Volts gradecable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLSH 1100 volts grade cable continuous earth wire of green colour code, complete all as specified and directed. Note:- (a) Two runs of6 sqmm cable and one run of 6 Sqmm cable as earth leadwith conduit shall be measured as one unit length for payment.(b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish. |
| 80 | S & F of sheet metal enclosure with socket and plug top and MCB single pole and neutral enclosure with two Pin and earth plug and socket complete with one single pole MCB, 240 V, 20 Amp, complete all as specified and directed. |
| 81 | Supply and fixing of LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 82 | Supply and fixing of LED Light fitting mirror type with high out put diffuser 2 feet,10 watt, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 83 | Supply & fixing of 45W LED building security light fittingincluding provision of 25/32mm bore GI light grade pipe1.2 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole/ wall, complete allas specified and directed. |
| 84 | S&F of surface /recessed mounted, round/squareLEDdown light fittingwith die cast aluminium housing and system wattage of 15/18W,including connecting up with PVC sheathed 3 core 1.5 Sqmmcopper conductor flexible wire fixed, complete all as specified and directed. |
| 85 | Supply and fixing of wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by twopull cord system, complete all as specified and directed. |
| 86 | Supply and fixingin repair Ventilating Fan250mm sweep,non metallic resin body,single phase 240 volts AC 50 Hz including louvers,and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan, complete all aspecified and directed by Engineer-in-Charge. Note : Old Ventilating Fan will be deposited to MES store Yard. |
| 87 | Supply and fixingin repair Ventilating Fan200mm sweep,non metallic resin body,single phase 240 volts AC 50 Hz including louvers,and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan, complete all aspecified and directed by Engineer-in-Charge. Note : Old material deposited to MES store Yard. |
| 88 | Supply and fixing of exhaust fan, steel body AC single Phase. 230V of size 300m sweep heavy duty 1400 RPM with, blades, and frame and louvers complete with all accessories for hang and connecting with 3 run of 1.5 sqm, multicore, PVC insulated copper cable from ceiling roseas specified and directed.Note : Old Ventilating Fan will be deposited to MES store Yard. |
| 89 | Supply & fixing of MCB DB SPN 12 way, double door, IP-43, IK-09, Isolated Neutral Bar and fixed flush to wall and suitable for universal mounting, complete all as specified and directed. |
| 90 | Supply and fixing of LED 2 X 2 ft backlite surface mounted fitting 36 Wattsnot less than 3200lm with Metallic CRCA powder coated body, complete all as specified and directed by Engr-in-Charge. |
| 91 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450m sweep heavy duty 1400 RPM with, blades, and frame and louvers complete with all accessories for hang and connecting with 3 run of 1.5 sqm, multicore, PVC insulated copper cable from ceiling rose, complete all as specified and directed. |
| 92 | Cutting the existing wall/removing existing steel bar to make a hole for fixing of ventilation fan through packing of wooden ply to support the ventilating/ air circulating fan including necessary nut and bolts of suitable size incl making good of disturbed surface, complete all as directed by Engr-in-Charge. |
| 93 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material |