| 1 | Disconnecting and taking down to the existing old burnt/ punctured cable from the site and Supply,lay, and commissioning of XLPE insulated, screened , PVC bedded, galvinised steel strip or wire armourd electric power cable (heavy duty) with alluminium conductor ,11000 Volts grade cross section area (a) 300 Sqmm 3 core |
| 2 | (b)240 Sqmm 3 core |
| 3 | (c)185 Sqmm 3 core |
| 4 | (d)120 Sqmm 3 core |
| 5 | (e)95 Sqmm 3 core |
| 6 | Disconnecting and taking down to the existing old burnt/ punctured cable from the site and Supply, lay, connect, test and commission cable LT 1100 volts heavy duty XLPE irsulated armoured aluminium conductor laid in trenches/ducts. (a) 3 1/2 core x 185 sqmm |
| 7 | (b)3 1/2 core x 95 sqmm |
| 8 | (c)3 1/2 core x 50 sqmm |
| 9 | (d)4 core x 25 sqmm |
| 10 | (e)4 core x 10 sqmm |
| 11 | Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation, trenches for laying cables/ pipe line etc. and getting out in soft/loose soil. |
| 12 | All as per item No 11 above but of hard and dense soil |
| 13 | Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil. |
| 14 | Removing excavated materials to a distance n. exc. 50m and depositing where directed at a level n. exc 1.50m above the starting point. |
| 15 | Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed.(Note: Punned thickness only shall be measured) |
| 16 | Supply and laying un-reinforced precast concrete cable cover, class HV,Type 1 flat,size 300X180X40mm |
| 17 | Supply and laying un-reinforced precast concrete cable cover, class LV,Type 1 flat,size 250X150X40mm |
| 18 | M&L in replacement for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed |
| 19 | Overhauling and servicing of OLTC unit for LT transformer of capacity 11000V /433V500 kVA comprising the following.Parts complete with all as per specified and directed by EIC.(a) Servicing of all mechanical gear wheels and moving parts, latches and releasing parts, over driven stoppingand restarting mechanism complete. (b) Cleaning of complete OLTC control chamber and fault finding.(c) Repairing to control wiring,replacement of burnt wires,lugs etc .(d ) Lubricating,greasing of all mechanical parts.(e) Servicing to electrical auxialary contactors and limit switches and HRC fuses complete. |
| 20 | Supply and replace silica Gel into the breather of transformers complete all as directed by EIC. |
| 21 | M&L for cleaning and removing of vegitations from existingaggregatesincluding cutting of bushes / plantsround the compound wall/installations (Inside & outside) and disposal of waste materials with complete all as specified and directed by EIC. |
| 22 | S&F in replacement Sensing board,Micro Board,firing board,Smart switch with its fixing arrangement complete suitable for 110V battery Charger with completeall as specified and directed by EIC |
| 23 | S&F in replacement AC/DC converter transformersuitable for Battery charger 110V/200 AH 50 Amps Make Amara raja power sysytem or Equivalent |
| 24 | Decarbonising / cleaning complete of HT 11KV RMU /VCB ,bus bar chamber, all electrical connections completeafter removing the bus bar spout, cleaning with petrol and CRC 226 spray solution and ensure proper de-carbonisation, refixing the same after completion all as directedby Engr-in Charge.. |
| 25 | S&F in replacement LC Filter (Chokes & capacitors)suitable for Battery charger 110V/200 AH 50 Amps complete with its connecting accessories with completeall as specified and directed by EIC |
| 26 | S&F in replacement Semi conductor Fuses 7 filter fusessuitable fot Battery charger 110V/200 AH 50 Amps complete with its connecting acessories.Make Amara raja power sysytem or Equivalent |
| 27 | S&F in replacement Dual block SCR suitable for 110V/200 AH 50 Amps Battery charger .Make Amara raja power sysytem or Equivalent |
| 28 | S&F in replacement AC & DC Input contactors and its acessories for 110V/200 AH 50 Amps Battery charger .Make Amara raja power sysytem or Equivalent |
| 29 | M&L in replacement for air break switch triple pole, manually/mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current ratingupto 400 Amps11 KV grade complete all as specified and as directed. |
| 30 | M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5mbelow normal ground level, connected ot galvanised iron strip of size 32 x 6mm earth lead by means of bolt, nuts, washers of galvanisediron or steel, earth strip protected by and including GI pipe 40mm dia bore (medium grade) and connected to main test point as directed including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:1½:3) type A-1 cover slab of size 54 x54 x 5 cm reinforced with 8mm dia TMT bars @ 150 mm C/C both ways with one handle for lifting, made out of 8mmdia TMT bar embedded in precast cover slab, funnel, wire mesh, 20mm bore GI pipe (medium grade) for watering, charcoal and salt in alternate layers, including necessary excavation and earth work in any type of soil complete all as shown on electrical plate No 5 of SSR Part-Iand testing incl taking down old complete all as specified and as directed. |
| 31 | M&L for heat shrinkable Cable joining kit forHT 11 KV (earthed) grade cable for indoor termination complete with joining materials and accesoriessuitable for aluminium conductor cable of size 3 core 120 to 185sq.mm complete all as directed. |
| 32 | All as per item No 31 above but for outdoor termination and size 3 CoreX120 Sqmm to 300 Sqmm |
| 33 | All as per item No 31 above but for indoor termination and size 3 CoreX400 Sqmm |
| 34 | All as per sl item No.31 above but stright through joint size 3 core 120 to 185sq.mm complete all as directed. |
| 35 | All as per sl item No.31 above but stright through joint size 3 core 95complete all as directed. |
| 36 | M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size |
| 37 | All as per item No 34 above for HT, 25x20cm size |
| 38 | S&F in replacement Insulated synthetic mat nominal 3.0mm thick confirming to IS 15652:2006 all as per and suitable up to 11 KV Colour blue complete. |
| 39 | M&L for CI Cable route Indicator |
| 40 | M&L for preparation of old painted surface, cleaning of surface portion complete for 16/11/9 /8.5 mtrs long pole above PCC coping with applying one coats of aluminium paint including brackets,clamps and terminal boxesand writing MES Nos of poles (number size shall be 25mm and lettering shall be 40mm) complete all as directed by Engineer-in-Charge. |
| 41 | All as per item 38 above but four pole structure of HT/LT includind bracings, cross arms etc complete. |
| 42 | Disconnecting transformer of capacity 500 KVA indoor/ out door from HT/ LT side at site, dismantling carefully and removing primary and secondary terminals, top cover, conservator tank, neutral earth strips and draining out transformer oil to the required level and storing carefully in cleaned containers, cleaning of terminals, inspection of core, supply and replacing 5mm thick rubberized cork sheet gasket for tank top cover and re assembling the complete dismantled items, re connecting the HT/ LT supply cable ends at the site complete all as directed by Engineer-in-Charge. |
| 43 | Taking out unserviceable defective HT bushings from transformers and S&F porcelain bushing with brass studs, nuts and washers connected to winding, testing and commissioning the transformer of capacity 500 KVA complete all as directed. |
| 44 | All as per item 41 above herein before but LT bush for transformer of capacity 500 KVA. |
| 45 | M&L for rewinding of HT/ LT transformers by winding the defective coils with new copper wire as per IS of same gauge and existing size together with new insulated materials and aluminium bracings before placing in to the transformer and assembling the HT/ LT coil with new insulation between core and LT coil and fitting the coils in the chamber, testing and commissioning the transformer and recording the test results complete all as directed. |
| 46 | M & L for servicing LT distribution panels completecleaning of panel with CTC and bus bar Chamberwelding of hingesincl checking ofincoming and out going connections and renewal of unserviceable switch fuse unit switch disconnector fuses/MCCB\"s, Frame works, incl of two coats of synthetic enamel paintall as specified and directed by Engr-in- Charge. |
| 47 | M&L for control wring of LT panel boards of capacity up to 630 Amps including replacement of 2.5 Sqmm stranded copper conductor such as volt/ ammeter, selector switches, indication lamps, ACBs, Relays, contacts, CTs including all necessaryconnections all as speecified and directed by Engr-in- Charge. |
| 48 | M & L for preparation ofold painted surfaces of HT/LT transformers of capacity 500 KVA including removing oilly and greasy spots and applying one coats of synthetic enamel paint including white wash to transformer foundation plinth and lettering with white paint as MES NO/SM No, capacity, year of installation, serial No over coat on black paint complete all as specified and directed. |
| 49 | Decorbonising/cleaningcapacitor bank panel, Rewiring electrical connections complete installed in various sub-stations after removing the complete chambar cleaning with CTC and ensure proper decorbonising, refixing the same after applying bectol RED solutions and checking all the connections and tightining the nut, bolts, system complete including replacement of defective rusted bolts ,nuts, washers,auto / manual selector switchs, ON / OFF switch buttons with elements etc all as specifid and directed . |
| 50 | Taking down the old unserviceable Multi-fuctioning meters and S&F newMulti- function meter ( Voltage, current, PF) disply of size 96x96 sqmmor suitable to existing at site for HT/Ltpanels |
| 51 | S&F in replacement Volt meters (0-440V)Volt on existing panel with connecting wiring complete. Make L&T or equi |
| 52 | S&F in replacement Ampmeters (0-100)Amp alongwith CTs complete on existing panel with connecting wiring complete. Make L&T or equi |
| 53 | Supply and Fix indication lamps 110/ 230V AC/DC with threaded type holderwith integral LED indication lamps 230v of 22.5mm dia holder suitable for R-Y-B phases complete all as specified |
| 54 | Supply and repair/replacement Isolating contact Finger/existing type suitable for 800 Amps VCB Make Sciender,complete all as specified |
| 55 | Supply, install, testing and commisioning in replacement of manual inter lock handle of dia 6mm completeall as specified and directed. |
| 56 | S & f in replacement closing coil ofmake Schneider or Equilent in ABB/CG/Siemens etc completeall as specified and directed. |
| 57 | M & L in repairs for breakerswitch 12 way( 6NO+6NC) of make Schneider or Equilent |
| 58 | M & Lin repairs for Racking Screw of VCB Panel of make Schneider or Equilent in ABB/CG/Siemens etc completeall as specified and directed. |
| 59 | M & Lin repairs for Racking Nut Panel of make Schneider or Equilent in ABB/CG/Siemens etc completeall as specified and directed. |
| 60 | M & Lin repairs for Mannual spring Charging handle unit upto 3150A HT VCB Panel of make Schneideror Equilent in ABB/CG/Siemens etc completeall as specified and directed. |
| 61 | S&F relay suitable for HT 11kV RMU SF6 based,2 I/c & 4 O/g feeders of rating 630A, 21kA/3sec fully motorised of make: Siemens ,Type : 8DJH St -LLLLL+L+ME and model Reyrolle - 7SR4501-1HA20-1AA/GG argos dual powered 24V - 60V complete all as directed by Engr-in-Charge. |
| 62 | M&L for Replacement of 11kV HT VCB relay VAMP255 or upgraded version P3U30 as per IEC 61850 protocol as per existing make Schneider or equi |
| 63 | S&F in replacement of potential transformer of HT 11kV HT Ring main unit incl copper control wiring for RMU and calibration, testing and commissioning of the PTs complete all as specified.Note:- Quoted rate shall be deemed to be inclusive of any minor spares/parts replaced fpor functioning. |
| 64 | S&F in replacement of current transformer of HT 11kV Ring main unit with necessary copper control wiring for RMU and calibration, testing and commissioning of the CTs complete all as specified.Note:- Quoted rate shall be deemed to be inclusive of any minor spares/parts replaced fpor functioning. |
| 65 | M&Lin repairs for Copper Control wiring incl contactors/MCBs for 11KV HT VCB for functioning of MFM meters/relays/display unit complete. |
| 66 | M & Lin repairs for Potential Transformer (FUSE): HRC Fuse-PT HT Side VTF-11, 3A of make Schneider or Equilent in ABB/CG/Siemens etc completeall as specified and directed. |
| 67 | M & Lin repairs for Limit Switch-1NO+1NC service/ test position of make Schneider cat pat No. ESW-B-AAA00-001 or Equilent in ABB/CG/Siemens etc completeall as specified and directed. |
| 68 | S &F in replacement of thermostat for Space Heater of existing make complete all as specified and as directed by Engineer in charge. |
| 69 | Repair/ replacement ofunder ground Fibre optic cable RJ-45 confirming to G-652 all as specified and directed |
| 70 | M&L for rewinding of outdoor duty isolator motorby winding the defective coils with new copper wire as per IS of same gauge and existing size together with new insulated materialsand assembling all as specified and directed |
| 71 | S&F in replacement loopin loop out PVC junction box shock proof, IP66/67 outdoor type, made out of size 300x200x105mm complete with 100 Amp 3 phase & one neutral rated aluminium bus bar with MS clamp of size 35x6mm MCB single 5 to 32 Amps inside box and fixed on pole with MS clamps, nut bolt and washers as specified and directed by EIC. |
| 72 | Repair/ replacement of 24 Watt LED luminaries with HF drive suitable completeall as specified and directed |
| 73 | Repair/Repacement of battery capacity of 12v 40AH suitable for solar lighting system based on 100/110Watt panel all as specified and directed |
| 74 | Repair/Repacement of battery capacity of 12v 26AH suitable for UPS based on 100/110Watt panel all as specified and directed |
| 75 | M&L for 16m high mast light wiring kit alongwith connector incl taking down u/s complete all as specified |
| 76 | S&F inreplacement of LED flood light fitting, 250 Watt LED input voltage 230VC, 50Hz with ingress protection IP 65 or above, CRI>70, PF>0.9, minimum 25000 burning hours, LM-80, lumen efficacy>=100 lumen/watt, THD>20, CRCA housing including fixing arrangement like clamps, nuts, bolts, washers, 120W LED lamp with all accessories pre-wired and connecting with twin corw twisted flexible copper conductor cable with all necessary staging, etc for fixing at any locations incl taking down the old unserviceale fittings complete all as specified. |
| 77 | All as per item No 74 above but 200W |
| 78 | S&F steel wire hemp rope of 6mm dia 316 standard by taking out damaged rope and other minor parts suitable for high mast fittings 15-20m high, like \"D\" clamps, nuts, bolts, washers, etc replacing as needed and making the insulation serviceable and testing for proper functioning on reinstating complete.Note:- Quoted rate shall be deemed to be inclusive of any necessities, T&P, etc. required for working at 15-20m heights etc. |
| 79 | M&L for replacement of timer switch of high mast lighting system/street light as per existing complete all as directed. |
| 80 | M&L for taking down by manual/motorised handle high mast light fittings at 15m to 20m height and refixing after necessary repairs incl all necessary staging etc for cleaning of perplex covers etc, tightning of loose connections on poles/walls, and replaceing worn out minor parts, etc and making the fitting functional complete all as specified and as directed.Note:- Quoted rate shall be deemed to be inclusive of any minor spares/parts replaced fpor functioning. |
| 81 | M&L for taking-out burnt winding of 3 phase power tool electric motor of high mast fittings from any position, rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves etc and testing for proper functioning on reinstating complete all as specified and as directed.Note:- Quoted rate shall be deemed to be inclusive of any minor spares/parts replaced for successful functionality of motor. |
| 82 | Dismantling and taking out old un-serviceable Non-integral light fittings from 15-20m High mast tower with checking its connections and unserviceable parts, such as Drivers, Lamps LED/Hallide, LED fittings etc and replace the same and refitting in its position incl servicing the double drum winch and greasing the 8mm dia steel wire rope, eheels, operating handles with all parts and equipments of existing High mast tower, fitting, allignment upto length, testing complete in all respects after the high mast tower mounted all as specified and directed. Note: The Light fittings to be replaced shall be measured separately under this schedule of item. |
| 83 | M&L for metal hallide lamps of 200watt high mast light fitting complete |
| 84 | M&L for taking down high pressure SV/MV/MH/FTL/LED street light fitting and Flood light fittings of any wattage/any height of pole/walls/any location for repairs or replacement of burnt out the accessories and rectifying the fault complete all as specified.Note:- LED drivers, Surge protection and cable shall be measured and paid separately under relevant items of this schedule. |
| 85 | M&L for replacement of Drivers for LED street lights 50/72W/120W complete all as specified. |
| 86 | PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for pole and stay complete all as specified and directed. |
| 87 | PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of pole etc including form work complete all as specified and directed. |
| 88 | M&L in repairs for metal spreading around the two pole structure/Trf yard area incl cleaning and removing grass of the area 4mX3m approx around the two pole structure, Spreading & levelling sand cushioning 15mm over the cleaning surface and spreading 40mm graded aggregate over the sand cushioning, paint the concrete surface with lime paint complete all as specified and directed Engr-in-Charge. |
| 89 | All as per item No 86 above but of four pole structures of size 5X5 metres |
| 90 | M&L in repairs for complete routine test of transformer upto 250KVA as (per IE rules) with authorised agency as per dir of Engr-in-Charge and submit the test results for maint of our record of any capacity. |
| 91 | S&F in replacement UV/IR detector of make Ravel/Agni or equi complete all as specified |
| 92 | S&F in replacement Control module for monitoring field device, operation voltage 17 to 28V complete all as specified and directed. |
| 93 | S&F in replacement of MCCB of capacity 4 pole 400 amps MCCB, 35/36 KAhaving breaking capacity Icu = 35/36 KA with adjustable load setting from 70 % to 100 % complete all as directed. |
| 94 | S&F in replacement of MCCB of capacity 4 pole 63 to 100 amps MCCB, 16 KA complete all as directed |
| 95 | Supplying and replace MCCB, 200 Amps, 4 pole, 415 Volts, AC supply,having breaking capacity Icu = 36 KA with adjustable load setting from 70 % to 100 % complete all as directed. |
| 96 | S&F in repairs MCCB of capacity 4 pole125 amps MCCB, 16 KA complete all as directed |
| 97 | Supplying and replace MCCB, 250 Amps, 4 pole, 415 Volts, AC supply,having breaking capacity Icu = 35/36 KA with adjustable load setting from 70 % to 100 % complete all as directed. |
| 98 | Supplying andreplace MCCB, 160 Amps, 4 pole, 415 Volts, AC supply,having breaking capacity Icu = 36 kA with adjustable load setting from 70 % to 100 % complete all as directed. |
| 99 | Supply and replace MCB ofcapacity SPN 20-32 Amps DP 240 Volt AC |
| 100 | Supply and replace MCB ofcapacity 6 to 32 Amps SP 240 Volt AC |
| 101 | Repairs/ servicing to incoming ACB 1000Amps capacity ,4 pole 65 KA contactor coil incl all necessary spares as required and directed |
| 102 | M&L for ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 1000 Amps with operating handle incl all necessary spares as required complete all as specified and directed |
| 103 | Supply, jointing and testing Cable jointing kit for 1100V grade cable for End Joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 300 sqmm |
| 104 | All as per item No 101 above butof size3.5core X 185 Sqmm |
| 105 | All as per item No 101 above but of size3.5core X 120 Sqmm |
| 106 | All as per item No 101 above but of size3.5core X 70 to 95Sqmm |
| 107 | All as per item No 101 above butof size3.5core X 35 to 50Sqmm |
| 108 | All as per item No 101 above but of size4core X 16/25Sqmm |
| 109 | Supply, jointing and testing Cable jointing kit for 1100V grade cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 240 to 300 sqmm |
| 110 | All as per item No 107 above but of size 3.5core X 150 to 185 Sqmm |
| 111 | All as per item No 107 above but of size 3.5core X 120 Sqmm |
| 112 | All as per item No 107 above but of size 3.5core X 95 Sqmm |
| 113 | All as per item No 107 above but of size 3.5core X 50 to 70 Sqmm |
| 114 | All as per item No 107 above but of size4core X 25 upto 3.5C X 35 Sqmm |
| 115 | M&L for extension of GI Strip of size 32 x 6 mm for transformer neutral and body earthing with suitable size nuts, bolts and washers complete. |
| 116 | All as per item No 113 above GI strip 50 X 10mm |
| 117 | All as per item No 113 above GI strip 75 X 10mm |
| 118 | To find out the electric flault in HT under ground cable by fault locating kit provided by Deptt and technician to be hired by the contractor for find out the exact fault location as per safety manner and earth work upto 6m depth is also inclusive in quoted rate wherever reqd all as specified and directed by Engr-in-Charge.Note:-(i) Technician should be well knowledge and experience in fault locating kit for using all command and controls.(ii) In a case the fault locating kit not provided by dept, the contractor shall provide the same without any extra cost to the govt. |
| 119 | All as per item No 116 above but LT under ground cable . |
| 120 | M&L for perforated GI cable tray 2mm thick of size 300X100mm including nut and bolts, joining complete all as directed |
| 121 | M&L lightening arresters 11000Volts, explusion type complete with all fittings, transmission class, discharge capacity 65 kilo Amphs including taking down old unserviceable one complete all as specified and directed by Engr-in -charge. |
| 122 | M&L in repairs for multicore Copper conductor cables, PVC insulated,LT1100 Volts and GI strip/wire armoured laid in ducts/on structures.cable trays incl clamps, terminations on both ends with glands and connecting upto the equipment of size 5 Core 2.5 Sqmm complete all as directed |
| 123 | All as per item No 120 above but of size 3 Core 6 Sqmmcomplete all as directed |
| 124 | M&L for aluminium conductor, steel reinforced any size including dismantling of existing conductors all as specified and directed by Engr-in-Charge. |
| 125 | Supply and fix pin type porcelin, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade all as specified. |
| 126 | M&L for servicing of mechanically operated, mounted on insulator and steel frame gang operated device of capacity upto 400Amps with operating mechanism worked from ground level, tighting of insulators, aluminium conductor and petrolium jelly to be used in connecting Knifes and contacts and scrapping of rusted mounting structure and one coat of weather proof paint to done on structure complete all as specified and directed by Engr-in-Charge.Note:- After servicing of GOD meggaring should completed all components are testing to be complete as per electricity rule. |
| 127 | Supply & replacement of GOD Triple pole, mechanically operated,mounted on insulator and steel frame, with operating mechanismworked from ground level, for current rating upto 400 amps for 11000 Volts complete all as specified and directed |
| 128 | M&L in repairs and Servicing to Fault locating Kit, Receiver, Micro phones and connected items of Make Telemetrics of rating 16kV by OEM incl spares required for the same complete all as specified and directed.Note:- (i) Quoted rate inclusive of transportaion of HT fault locating kit set from and to workshop charges. |
| 129 | M&L for attendending breakdown of 11kV HT Ring Main Unit ,SF6 based,2 I/c & 4 O/g feeders of rating 630A, 21kA/3sec fully motorised of make: Siemens , Type : 8DJH St -LLLLL+L+ME by OEM representative or licenced engineer complete all as directed by Engr-in-Charge.Note: (i) The rate quoted shall be incluse of (a) OEM rep or licenced engineer. (b) Minor spare parts like nut & bolts etc.(ii) The mojor spare parts like relay will be paid & measured seprately in respective BOQ item. |
| 130 | Total Amount in Figures |
| 131 | Quoted Amount in Words |