| Sl. No. | Item Description |
| 1 | Taking down cement plaster including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed. |
| 2 | M&L for rendering 15 mm thick in CM 1:6 on brick masonary wall surfaces or on other than fair faces of brick masonry finished even and smooth witout using extra cement complete all as specified and directed. |
| 3 | M&L for 15mm thick rendering in cement mortar 1:4 to on brick masonary wall surfaces or on other than fair faces of brick masonary fairfinishedwithout using extra cement with using water proofing liquid @ 0.15 Ltr per bag of cement complete all as specified and directed.(Note : Water proofing liquid shall be measured and paid separately) |
| 4 | M&L for rendering 10 mm thick in CM 1:4as on concerete surface on ceilings finished even and smooth without using extra cement complete all as specified and directed. |
| 5 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 6 | M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust including brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and as directed |
| 7 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons Laid, bedded and pointed in any mortar etc. complete all as specified and directed. |
| 8 | M&L for non skid-ceramic tilescolouredof size area of each tile exc.0.06 sqm but not exc . 0.11 sqm (300 x 300 mm) X 6mm thick in floors etc, set & jointed in neat cement slurry and pointed in white or colours cement to matchover and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 9 | M&L for glazed ceramic tilescolouredof size 350 x 450 x 7mm thick in walls etc, set & jointed in neat cement slurry and pointed in white or colours cement to matchthe colour of tiles over and including 10mm thick rendring in CM (1:4) complete all as specified and directed. |
| 10 | M&L for vitrified ceramic tiles of dark shade/ Double Charge, 9 to 10 mm thick (square/rectangular) of size 1200 mm x 600 mm as in floors etc. over and including 15 mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match with shade of tiles, complete all as specified and directed. |
| 11 | M&L for vitrified ceramic tiles of dark shade/ Double Charge, 9 to 10 mm thick (square/rectangular) of size 1200 mm x 600 mm as in Dado Skirtin etc. over and including 10 mm thick Backing Coat in CM 1:3 set and jointed in neat cement slurry and pointed in white or coloured cement to match with shade of tiles, complete all as specified and directed. |
| 12 | M&L for 18-20 mm thick granite of black colour (tablee rubbed and polished) as in windows cill, in steps, jambs, pillars, cooking platforms and like in cement mortar (1:4) including form work , pointing in white cment (1:2) using marble dust with admixture of pigment to match with shade of granite with full round bull nosing edging complete all as specified and directed. |
| 13 | Demolition of unreinforced cement concrete is ground floors andy pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 14 | M&L for 25 mm thick PCC 1:2:4type B0, using 12.5mm graded aggregate as in floors toreceive surface of tile complete all as specified and directed. |
| 15 | M&L for 75mm thick PCC 1:3:6 , type C-2 using 40 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 3 mtr in length.Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed. |
| 16 | M&L for 100 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base floor / pavings complete all as specified and directed |
| 17 | M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed. |
| 18 | M&L for cement concrete coloured interlocking paver blocks shall be factory made with casting in rubber/pvc moulds & compacting on a vibro table assembly and shall be cured in curing tank for atleast 14 days and then air dried before use. The paver block shall be confirming to IS 15658 -2006 of60mm thickness, M-35 Gradeapproved design, shape, size and colour of top layer complete all as specified and directed. |
| 19 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 20 | M&L for brick work with fly ash old size bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as specified and directed. |
| 21 | Taking down Chowkats or frames with shutters (without taking off shutters from the frame) n.exc 1.50 sqmand removing from site including making good disturbed portions of wall with new or old bricks, lintel, cills etc in CM 1:4 complete all as specified and directed. |
| 22 | Taking down Chowkats or frames with shutters (without taking off shutters from the frame) exc 1.50 sqm but n.exc 4.0 sqm each and removing from site including making good disturbed portions of wall with new or old bricks, lintel, cills etc in CM 1:4 complete all as specified and directed. |
| 23 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick single side prelam PVC sheet used instead of Plain colour PVC sheet , suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 24 | S&F 30 mm thick factory made both side Prelam PVC sheet used instead of Plain colour PVC sheet. Stile and rails feathered at edges consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C\" channel heaving aPanelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 25 | M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with and including MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. |
| 26 | M&L for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and provision and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. |
| 27 | S&F aluminium alloypowder coated aluminium door frame fixed with side hung shutters and glazing fixed with and including 5.50mm thick tinted glass fixed with rubber gasket with aluminium heading, clips frame made with aluminium box sec as appended below complete all as specified and directed (a) Frame 100x44x1.20mm thick with rawl plug(b) Middle/style rail : 85x44x1.20mm thick(c) Bottom/top rail : 114x44x1.20mm thick(d) Aluminium beading : 0.7mm thick(e) Aluminium handle D type 150mm long, aluminium tower bolt 9.9mm dia shoot 200mm long brass mortise lock 100mm 4 leaver aluminium stopper, cleat double action floor spring hydraulically regulated made of n.less than 1.25mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other part of steel heavy duty.(f) Making good of wall surface to match with existing surface complete. |
| 28 | S&F 12 mm thick toughned glass door withpowder coated aluminium frame including neccessary locking ,handle etc withdouble actionfloor spring in each shutter complete as requirement of site with suitable height and any type of eaching designed on tougned glass, off cuts completewith finishing wall in CM 1:4 , designed approved by GE complete all as specified and directed. |
| 29 | S&F Powder coated aluminium sliding windows frame with movable shutter ( sliding on minimum two PVC roller of best quality, for each shutter on threetracks with stainless steel mosquito proofing and glazing shutter and incl 5.00 mm thick glass & stainless steel wire mesh fixed with neoprene rubber gasket with aluminium beading, clips,frame made with aluminium section as appended below- (i) Window frame :95x38mm X 1.15 mm thick for three tracks.(ii) Top/bottom rail and style / rail of shutter : 15x37.5x1.15 mm thick and over. (iv) stainless steel wire cloth 0.45mm nominal dia of wire and average width of aperature 1.40mm and fixed in aluminium window or alongwith F/Y section fixed with aluminium wire staples complete.(v)Aluminiumfittings suchaluminium suitable handle with auto interlock cap with suitable size .(vi) Making good of wall surfaces with silicon to match with existing surfaces complete all as specified and directed. |
| 30 | S&F Powder coated aluminium sliding windows and frame with movable shutter ( sliding on minimum two PVC roller of best quality on two tracks Aluminium composite panel shutter fixed with neoprene rubber gasket with aluminium beading, clips,frame made with aluminium section as appended below-(i) Window frame :45.2x35mm X 1.15 mm thick for two tracks.(ii) Top/bottom rail and style / rail of shutter : 15x37.5x1.15 mm thick and over.(iii) Aluminium beading - 0.7mm thick(v)Aluminiumfittings suchaluminium suitable handle with auto interlock cap with suitable size .(vi) Making good of wall surfaces with silicon to match with existing surfaces complete all as specified and directed. |
| 31 | S&F powder coated aluminumwindow/ doors grills fixingalong with frame of following specification, grills with opening 69.4mm x 78.2mm grills thickness shall be of 6.4mm x 5.8mm having weight not less than 2.306 Kg/per sqmshape as ordered with frame channel of 34 x 11mm x 1.7mm thick fixed with screw inside of the window complete all as specified and as directed. |
| 32 | S&F Powder coated aluminium ventilators box type with louvers & wire mesh fixed with neoprene rubber gasket, aluminium beading, clips. Frame made with powder coated aluminium section of size as appended below (i)frame :45.2mm x35mm X 1.15 mm(ii) Aluminium beading - 0.7mm thick(iii) Glass louvers depth 6 inch. Blade Angle: 38 degrees and thickness of blade 2.02 mm with 106.25 mm spacing.(iv) Aluminium neccessary fittings complete as required.(v) Making good of wall surfaces with silicon to match with existing surfaces complete all as specified and directed. |
| 33 | S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cost or extruded sections or cost alumminium alloy complete all as specified and directed. |
| 34 | S&F 150 mm thick Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 35 | S&F 150mm size aluminium handles, cast type anodised completed all as specified and directed. |
| 36 | Taking up or down 15 mm steel tubingand connections including cleaning for refixing or removal complete all as specified and directed. |
| 37 | Taking up or down 20 mm steel tubingand connections including cleaning for refixing or removal complete all as specified and directed. |
| 38 | Dismantling water tanks500 & n exc 1000 and removing to store of all retrieved material complete all as specified and directed. |
| 39 | S&F rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe, tank cover etc complete all as specified and directed. |
| 40 | S&F in repair, Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe20 mm dia (minimum weight 210 gms) complete all as specified and directed. |
| 41 | S&F 15 mm dia steel water tubing galvanized medium grade concealed in all type wallwith all fittings, fixed to walls and ceiling or in floor complete all as specified and directed. |
| 42 | S&F 20 mm dia steel water tubing, galvanized, medium gradeconcealed in all type wallwith all fittings,fixed to walls and ceiling or in floor complete all as specified and directed |
| 43 | S&F in repair Vitreous Chinawash down water closet pan (Pedestal Pattern) and trap (standard pattern) coloured as approved including connection to drain (or outgoing pipe) and to flushing pipe anti symphonize pipe etc. including plastic water closet seat, white/black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and jointingcomplete with fixing bolts complete all as specified and directed. |
| 44 | S&F in repair light coloured vitreous china counter top oval shape wash basin white available shape as approvedof550mmx400mm (minimun)on new pre-painted brackets excluding taps but including 32 mm bore waste fittings, brass, chromium plated etc complete all as specified and directed. |
| 45 | S&F in repair PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets of 10 ltrs capacity complete all as specified and directed. |
| 46 | S&F in repair Vitreous China bowl urinal flat back of size 465 x 355 x 265 mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern flush pipe and waste pipe), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed. |
| 47 | S&F 600mmx450mm Looking mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 48 | S&F in repair 15mm bore dia fancy type pillar taps cast copper alloy with capstan heads, chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shank supply and fixing ly nuts for iron pipe complete all as specified and directed. |
| 49 | S&F in repair 15mm bore dia fancy type chromium plated Bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 50 | S&F in repair of CP brass fancy type stop cock with long shank& as concealed type/ angular type complete all as specified and directed. |
| 51 | S&F in repair 15 mm bore dia of pipe, CP two way bib tap 15mm dia complete all as specified and directed. |
| 52 | S&F in repair stainless steel of AE - SI 316 grade tubulartowel ringincluding apair ofCP brass bracket complete all as specified and directed. |
| 53 | S&F in repairs 15mm bore PVC connections, with PTMT nuts of length 450mm complete all as specified and directed. |
| 54 | S&F in repair fancy type brass chromium plated soap dish of 160x160x90 mm complete all as specified and directed. |
| 55 | S&F PVC (SWR) pipes 110 mm bore of pipe, single socketed in any length with rubber ring joints fixed to walls including repair and replacement old pipe complete all as specified and directed. |
| 56 | S&F 75mm dia PVC (SWR) pipe and single socketed in any length with rubberring joint laid in trenches or in floorincluding repair and replacement old pipe complete all as specified and directed. |
| 57 | S&F PVC (SWR) bends of 110 mm bore and any radius complete all as specified and directed. |
| 58 | S&F 75mm bore PVC (SWR) bend in any radius complete all as specified and directed. |
| 59 | S&F in repair 75 mm size PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed. |
| 60 | S&F 75mm bore PVC (SWR) junction (single ‘T’) equal or unequal complete all as specified and directed. |
| 61 | S&F 110mm bore PVC (SWR) junction (single ‘T’) equal or unequal complete all as specified and directed. |
| 62 | S&F rolled steel Bands, straps, supports or stays for rainwater, ventilating pipes,including bolts, if required: hooks (stay), heavy, for large complete all as specified and directed. |
| 63 | Dismantling of wall & celling boards (fiber pulp insulation etc) or insulation boards/slabs/blanketsany thickness, including cover fillets complete all as specified and directed. |
| 64 | Providing & fixing 10mm thick plaster of paris false ceiling bending as required shape with two coats of plastic emulsion paint over a coat of primer on decorated surfaces of ceiling including 26 gauge galvanished iron sheet \"C\" shaped main member @750 mm C/C cross member \"U\" shaped @450 mm c/c and perimeter of \"C\" shaped GI wire mesh having aperture 6.5 mm with 26 gauge wire GI wire 6mm dia or more or FI 40 x 4mm thick for hanging arrangement with MS suspension, fastner spaced @ 450mm c/c in both direction the \"C\" member shall be made out of not less than 90mm wide GI sheet strip and side tray as required of approximate size 3.5 Mtr height as required at site complete all as specified and directed. |
| 65 | Providing & fixing false ceiling at all heights with GRG (Glass Fiber Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanized iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 66 | S&F in repairPVC hollow interlocking wall paneling of 5mm thick prelam PVC sheet. The panel & strips shall be of 600 kg / cum density manufactured by an ISO-9000 certified company. The strips should two PVC strips. The PVC strip shall be fixed to the wall using 65mm long M.S screws through the groove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200mm.The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. Optionally a strips of 5mm thick PVC sheet of width 75mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cement. |
| 67 | Demoliton of cement concrete of any description & in any position not otherwise specifically provided for and complete all as specified and directed. |
| 68 | M&L for applying cement slurry over existing roof surface @ 3 Kg/Sqm incl mix with water proofing liquid @ 0.15 ltr per 50 kg cement bags as per manufactures instructions complete all as specified and directed. |
| 69 | M&L cement concrete 1:2:4 mix type B-0 (12.5 mm graded stone aggregate) in padding finishing surface of concrete topping even and fair (without using extra cement) of average thickness 40mm in slope as required over roof completeall as specified and directed. |
| 70 | M&L for 10mm thick plastering in CM(1:4) on concrete roof surfaces using water proofing compound @ 3% by weight of cement and finishing the surface even and fair including taking down existing plaster and APP membrane all as specified and directed.Note :- WPC shall be measured and paid separately. |
| 71 | S&F APP polymeric water proofing membrane, minimum 3mm thick and weighing above 3.0 Kg/Sqm with rich bitumen and select polymers blended to obtain excellent heat resistant& cold resistant , black finish reinforced with non-wovenpolyester matt, with a thermo fusable finish laid over compatible bitumen primer torching overlaps with a propane or a butane gas torch, with a overlap of 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions completed including removal of existing treatment all as specified and as directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 85/25 confirming to IS-73, [email protected] Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm(ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii)The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv)In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen (v) Above aspects are deemed to be included in quoted rate. |
| 72 | M & L for WPT in sunken floors as described here under:- Sunken floor and sides up to finished floor level shall be plastered with 15 mm thick cement plaster in CM 1:4 mixed with water proofing liquid @ 150 ml per bag of cement . (ii) Preparing plastered surfaces and providing APP polymeric water proofing membrane, minimum 4mm thick and weighing above 4.0 Kg/Sqm of membrane with rich bitumen and select polymers blended together to obtain excellent heat resistance & cold resistant by Water proofing liquid as approved by GE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over compatible bitumen primer (Bitumen primer shall beat the rate of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer\"s instructionsincluding preparation of surface by removing the existing treatment, complete all as specified an as directedNote :-(i) Polymeric membrane shall belaid in sunken floor and on sides up to finished floor level.(ii)The waterproofing treatment shall be got carried out by the manufacturer or their authorised applicators. (iii)Above aspects are deemed to be included in quoted rate. (iv) Supply only water proofing liquid shall be measured and paid seperately |
| 73 | Supply only integral water proofing compound ISI Marked complete all as specified and directed. |
| 74 | M&L PCC 1:5:10 type E-2 (40 mm to 80 mmgraded stone aggregate) as sunken sub base of floor fillings complete all as spd as directed |
| 75 | S&F 32mm dia GI pipe, medium grade as in spout pipe in sunken floor complete all as specified and directed. |
| 76 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 77 | M&L forreinforced cement concrete 1:1.5:3 type A-1 (using 20mm graded stone aggregate) (nominal mix) as in slabs supported on wall,landing, balconies, shelves and like including bonding agent complete all as specified and directed. |
| 78 | M&L form work to chajja, weather shade, troughs and similar items includingedges for rough finished surfaces of concrete flat complete all as specified and directed. |
| 79 | M&L form work to edges of concrete flats, treads, breaks in floors window cill, concrete railing opening in conc wall , floor and roof n.exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n.exc 20cm wide for rough finished surfaces of concrete complete all as specified and directed. |
| 80 | S&F mild steel TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) but not less than 0.9 mm dia conforming to Fe-410 - 0 complete all as specified and directed. |
| 81 | S&F door closer aluminium (extruded) hydraulically regulated designation No 1 universal type, suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 kg and fixed. |
| 82 | S&F in repair heavy duty hydraulic floor door spring fixed to floor for heavy toughend glass door including top ss bracket with pivot for fixing of glass with glass partition including all taking down and refixing of heavy glass any type complete all as specified and directed. |
| 83 | S&F in repair20 mm dia stainless steel 1.0 mm thick fancy typedroppery rod with decorative design matching brackets as approved and knobs (lattu) or end bracket as required incl fitting with 80 mm long SS screw with 75 mm long wooden gitty of appropriate c/s in each end & intermediate support complete all as specified and as directed |
| 84 | M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, Chajja ( up to IInd floor) etc making good, cutting exc 10cm and not exc 20cm girth in brick walls complete all as specified and directed. |
| 85 | Dismantling of concrete by chiseling from RCC members like column , beam, parapet facia, chajja, ceiling,etc exposingthe reinforcement without disturbing the reinforcement free from rust by sand blasting/using chemical , apply a coat of rustolin to remove rust and acralic polymer on old rusted reinforcement proving at places addl reinforcement welding with existing reinforcement as directed wherever required binding RCC 50 mmx50 mm (10 mm gauge welded mesh ) & tack , securing with clips / blinding wire, welding & provision guniting pressure 2.2 to 2.5 kg /sqm with admixer 1 cement 3.5 of sand of thickness 25 to 40 mm including stripping floating with wooden strippers for proper dimension control neccssary form work & scaffolding up to three storey and including height of head room complete surface of guniting to be finished fair with 10 mm thick plaster in cement mortar 1:4 with water proofing compound @3% by weight of cement and construction fibre as per manufacturer instruction cleaning & removing of waste meterial etc as dirply two coat of Water proofing liquid at interval of 8 hours cure for thesurfaces complete all as specified and directed. |
| 86 | Dismantling of plain or corrugated Asbestos cement including Nanital or similar pattern roof covering complete all as specified and directed. |
| 87 | S&F 6 mm thick asbestos cement, corrugated or semi corrugated sheeting roofs,walls etc. complete all as specified and directed. |
| 88 | Complete removal of existing treatment from old brick/ concrete surface on walls and applying two coat of Oil bound distemper using roller, brushes including in patches over a coat of alkali resistant primerand including 1.50 mm thick cement based wall care putty in two layers with making the surface complete smooth by rubbing etcwith minimum 6 hr interval between any two coats complete all as specified and directed. |
| 89 | Complete removal of existing treatment on old surfaces by vacuume based sanding machine; scrapping down smoke soot, moulds, moss and efflorescent salts and greasy spots , removing nails etc,and applying Two coats of exterior Acrylic emulsion (Apex)/Equivalent of any colour over one coat of exterior water based wall priming on walls with and including provision of scaffolding required for the treatment to external surfaces of buildingwith required safety measures etc complete all as specified and as directedby Engineer in charge.Note : The work shall be executed stage wise and each stage approved by Engr-in-Charge.Stage 1 : Complete removal of existing treatment.Stage 2 :Priming with exterior water based wall primingStage 3 :1st coat ofexterior Acrylic emulsion of any colourStage 4 : 2nd coat of exterior Acrylic emulsion of any colour |
| 90 | M&L for applying 1mm thick putty for smooth finish on prepared surface complete all as specified and directed. |
| 91 | M&L for preparing newly plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed. |
| 92 | Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/pointscomplete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors, etc complete all as specified and directed. |
| 93 | Taking down main switch / MCB DBs including MCBs etc of any size and making good distrbed surfaces to match with the existing surfaces of walls, floors etc complete all as specified and as directed. |
| 94 | Taking down Geysers and disconnecting water & electric connections, removing to store for keeping in safe custody for BER complete all as specified and directed. |
| 95 | Taking down Ceiling fan/Exhaust fan, sealing cable end,dismantling blades and removing fan and blades to store for keeping in safe custody for BER Board complete all as specified and directed. |
| 96 | Taking down sub main wiring /service cable including earth wire and making good disturbed surfaces to match with the existing surfaces of walls, floors complete all as specified and directed. |
| 97 | M&L for point wiring using proper colour coding complete all as specified with 1.5 sqmm PVC insulated FRLS unsheathed 1100 volts multistranded copper conductor two single core cable (Red and Black colour) confirming to IS 694:1990 Part-II with and includingnon metalic rigid PVC Conduit 25mm dia medium grade with all accessories including cutting chases pinning in, for concealed conduit wiring in wall/ceiling/floor/roof etc, making good of disturbed surface not exc 15cm girth, modular sunk pressed steel terminal box not less than 2mm thick, 50mm deep, covered with frame plate with cover for 01 to 16ways suitable for modular fittings including 1.5 sqmm PVC insulated FRLS unsheathed 1100 volts multistranded copper conductor one single core cable (Green colour) confirming to IS 694:1990 Part-II as continuous earth wire connected to common earth dolly all as specified and as directed for the following:- (a) One light/fan/exhaust fan/bell point controlled by one modular switch/bell push. |
| 98 | All as per above Item No. 97 but one 3 pin modular socket outlet 5 Amp on the same board with other switch complete all as specified and directed. |
| 99 | All as per above Item No. 97 one 3 pin modular socket outlet 5 Amp independent board complete all as specified and directed. |
| 100 | All as per above Item No. 97 one light point controlled by two, 2 way modular switch complete all as specified and directed. |
| 101 | All as per above Item No. 97 but one 3 pin socket outlet 15 Amp independent board with 2.5 sqmm PVC insulated FRLS unsheathed 1100 volts multistranded copper conductor single core cable (Red, Black and green colour) confirming to IS 694:1990 Part-II complete all as specified and directed. |
| 102 | M&L for modular switch, 1 way 6 Amp, 1 module complete all as specified and directed. |
| 103 | M&L for modular switch, 2 way 6 Amp, 1 module complete all as specified and directed. |
| 104 | M&L for modular switch, 1 way 16 Amp, 1 module complete all as specified and directed. |
| 105 | M&L for modular bell switch 6Amp, 1 module complete all as specified and directed. |
| 106 | S&F modular socket 6Amp, 2/3 pin, combined 2 module complete all as specified and directed. |
| 107 | S&F modular socket6A/16A, 2/3 pin combined 2 module complete all as specified and directed. |
| 108 | M&L for buzzer, ding dong, AC, 230V single pole complete all as specified and directed. |
| 109 | M&L for modular stepped type fan regulator, 120Watts - 2 module complete all as specified and directed. |
| 110 | S&F ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body of size complete all as specified and directed. |
| 111 | S&F lamp holder (Batten/Angle) PVC/Polycarbonate type with back plate for batten/angle fittings, complete all as specified and directed. |
| 112 | S&F for Lamp LED ADORE PLUS 1 x 9 Watts, CDL, 3 Star rating,heat sink white with Polycarbonate diffuser, B-22 base cap, retrofit type, 220/230 volts, complete all as specified and directed. |
| 113 | S&F LED lights fitting 1x 20 Watts (T-8), 4 feet long, 220V, AC, decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, prewired complete with two Nos of PVC box of size 75x75x20mm for mounting light fittings complete all as specified and directed. |
| 114 | S&F LED light fitting 1 x 10 Watts (T-8), Mirror type with high out put diffuser 2 feet long, 220 Volts, AC decorative type with driver holder and LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, prewired complete with two Nos of PVC box of size 75x75x20mm for mounting light fittings, complete all as specified and directed. |
| 115 | S&F LED light fitting 1x9W/1X10W Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size with LED Lamp 1 X 9/10watts, complete all as specified and directed. |
| 116 | S&F decorative wall light fixture made up of Polycarbonate, suitable for 1 x 9 Watts, retrofit LED lamp, B22 base, CITY-2, 220 Volts, AC, complete all as specified and directed. |
| 117 | S&F in replacement of LED 1 x 18 watts, 6500 K lamp type, slim surface mounted round type, LED panel with premium diffuser to ensure glare free & even light distribution with driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 118 | S&F in replacement of LED 1 x 18 watts, 6500 K lamp type, slim surface mounted square type, LED panel with premium diffuser to ensure glare free & even light distribution with driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 119 | S&F in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V, AC, Recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 120 | M&L for telephone jak RJ 11 tel with sutter 1 module with modular concealed GI sheet metal flushed box including cover plate for 1/2 way module complete all as specified and directed |
| 121 | S&F TV socketout let single module with modular concealed GI sheet metal flushed box including cover plate for 1/2 way module complete all as specified and directed. |
| 122 | Supply and lay of PVC insulated industrial flexible cable for RG 6 Co axial cable-jelly copper conductor suitable for TV cable connection drawn through PVC conduit 25 mm dia complete all as specified and directed.Note:- PVC conduit 25 mm dia shall be measured and paid separately. |
| 123 | M&L for 2 pair telephone cable copper conductor of 0.5 mm dia drawn through PVC conduit 25 mm dia complete all as specified and directed.Note:- PVC conduit 25 mm dia shall be measured and paid separately. |
| 124 | M&L in replacement of Rigit non-metallic PVC conduit of external dia 25mm (ISI marked) exclusive of boxes (Junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts saddles pipe hooks etc complete all as specified and directed.Note:- PVC junction boxes (1 to 4 way) suitable for 25 mm dia measured and paid separately. |
| 125 | S&F in replacement of PVC junction boxes (1 to 4 way) Suitable for conduits of size 25 mm NB complete complete all as specified and directed. |
| 126 | M&L for sub main wiring with two run of single core PVC insulated unsheathed FRLS copper conductor cable 1100 volt grade multistandard of size 4.0 sqmm (Red and Black colour) and incl drawn through Rigid non-metallic PVC conduit 25mm dia (ISI Marks) including accesssories, one run of single core PVC insulated unsheathed FRLS copper conductor cable 1100 volt grade multistandard of size 4.0 sqmm (green colour) for earth continuity wire and connected of common earth dolly complete all as specified and directed.Note:- One run of Rigid non-metallic PVC conduit 25mm dia, three run of 4.0 sq mm copper conductor cable is measured as one unit. |
| 127 | S&F in replacement of wall mounting fans 230 volts. single phase, 50 Hz, 1450 RPM, Oscillating 400 mm sweep suitable for wall mounting, made of metal body, Copper winding including connecting up with three core flexible copper conductor cable for suitable size and wall mounting fastener bolt, nuts & washers etc, complete all as specified and directed. |
| 128 | S&F sheet metal enclosure 20Amp SP (2P+E) with Metal plug and socket DBs suitable for protection of appliances like AC/Geysers etc complete with one MCB single pole 20Amps, 240Volts including connection, testing and making good the disturbed surfaces, complete all as specified and directed. |
| 129 | S&F sheet metal enclosures MCB SPN DBs 12 Way, 240 Volts, 50Hz, AC, double door (12) suitable for flush mounting and surface mounting, conforming to IP 43 - IK 09 with acrylic door with 200 Amp copper bus bar for phase, complete with din rail, Neutral and Earthing bar, including connection, testing and making good the disturbed surfaces complete all as specified and directed. |
| 130 | S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 131 | S&F GI Bracket made out from GI pipe 25/32mm dia bend to shape as required, 1.2Mtr long fixed on wall with flat iron clamps of size 25 x 4mm - 2 Nos with the help of bolts, nuts, washers etc for fixing of security light fitting complete all as specified and directed. |
| 132 | M&L for sub main wiring with two run of single core PVC insulated unsheathed FRLS copper conductor cable 1100 volt grade multistandard of size 6.0 sqmm (Red and Black colour) and incl drawn through Rigid non-metallic PVC conduit 25mm dia (ISI Marks) including accesssories, one run of single core PVC insulated unsheathed FRLS copper conductor cable 1100 volt grade multistandard of size 6.0 sqmm (green colour) for earth continuity wire and connected of common earth dolly complete all as specified and directed.Note:- One run of Rigid non-metallic PVC conduit 25mm dia, three run of 6.0 sq mm copper conductor cable is measured as one unit. |
| 133 | S&F ceiling fan 1200mm sweep, complete with blades, down rods and accessories, 230 V, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including connecting up with three core flexible copper conductor cable for suitable size, complete all as specified and directed. |
| 134 | S&F heavy duty exhaust fan 300mm sweep, made of metal body complete with louvers shutter, voltage 230V, 50 Hz, 1200 RPM, Copper winding including connecting up with three core flexible copper conductor cable for suitable size and wall mounting fastener bolt, nuts & washers etc, complete all as specified and directed. |
| 135 | S&F water heater storage type, electric,capacity 25 litres.BEE 5 star rated, voltage 230V, 50 Hz, Copper tank including connecting up with three core flexible copper conductor cable for suitable size and wall mounting fastener bolt, nuts & washers etc, complete all as specified and directed. |
| 136 | S&F sheet metal enclosures MCB SPN DBs 8 Way, 240 Volts, 50Hz, AC, double door (12) suitable for flush mounting and surface mounting, conforming to IP 43 - IK 09 with acrylic door with 200 Amp copper bus bar for phase, complete with din rail, Neutral and Earthing bar, including connection, testing and making good the disturbed surfaces complete all as specified and as directed. |
| 137 | S&F sheet metal enclosures MCB TPN DBs 6 Way, 240 Volts, 50Hz, AC, double door (18) suitable for flush mounting and surface mounting, conforming to IP 43 - IK 09 with acrylic door with 200 Amp copper bus bar for phase, complete with din rail, Neutral and Earthing bar, including connection, testing and making good the disturbed surfaces complete all as specified and directed. |
| 138 | S&F miniature circuit breaker (MCB), triple Pole & Neutral 40 to 100 Amp, rating 240V, 10 KA current carrying capacity, \"B\" curve fixing in the MCB DB complete with connection testing and commissioning, complete all as specified and directed. |
| 139 | S&F miniature circuit breaker (MCB), Single Pole & Neutral 40 to 63 Amp, rating 240V, 10 KA current carrying capacity, \"C\" curve fixing in the MCB DB complete with connection testing and commissioning, complete all as specified and directed. |
| 140 | S&F miniature circuit breaker (MCB), Single Pole 6 to 32 Amp, rating 240V, 10 KA current carrying capacity, \"B\" curve fixing in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 141 | Supply, laying, conecting and testing of ISI marked 50 mm bore GI steel water tubing medium grade Including S & F all fittings and fixed complete to walls and celling or laid in floors complete all as specified and directed. |
| 142 | Supply, laying, conecting and testing of ISI marked 40 mm bore GI steel water tubing medium grade Including S & F all fittings and fixed complete to walls and celling or laid in floors complete all as specified and directed. |
| 143 | Supply, laying, conecting and testing of ISI marked 25 mm bore GI steel water tubing medium grade Including S & F all fittings and fixed complete to walls and celling or laid in floors complete all as specified and directed. |
| 144 | S&F 25 mm bore Gun metal globe valve or gate valve with iron wheel head , screwed both ends with 01 No union for iron pipe heavy duty with ISI marked complete all as specified and directed. |
| 145 | S&F 50 mm bore Gun metal globe valve or gate valve with iron wheel head, screwed both ends with 01 No Union for iron pipe heavy duty with ISI marked complete all as specified and directed. |
| 146 | Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for laying of electric cables or water pipe etc, not exc 10 sqmm on plan and not exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. Note : Rates includes removing of paver blocks carefully and stack properly for refixing after laying of cables . |
| 147 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed. |
| 148 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail