| 1 | M&L in Repair for Earthing complete withgalvanized steel earth plate electrode 60 cmx 60 cm x 6 mm thick buried directlyin ground (earth pit notless than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level,connecting to theGalvanised iron strip 25x4 mm by means of bolts, nuts , check nuts and washers of galvanized iron andsteelearth wire protected by provision of GI lightgrade pipe40 mmbore including provision of concrete pitmade from PCC ( 1:2:4) type B-1 (using20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angleiron40 x 40 x 6 mm and handle of 6 mmdia MS barmade to shape, GI light grade 20 mmbore pipefor watering perforated atbottom, 1.50metre long placed on top edge of earth plate, common salt &charcoalfilling, withfixing arrangement , funnel, wire mesh and earthwork in hard/dense soil, returning filling in and removal of surplus soilto a distance notexceeding50 metres, all as perelectrical plate No 5 of SSR 2009 Part-I and connecting toTransformer / Poles all as specified or indicated including testing, complete all as specified and as directed by Engineer-in-Charge. |
| 2 | M&L in Repair for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing/connecting as required 25x4 mm galvanised iron strip, complete all as specified and directed by Engr-in-charge. |
| 3 | M&L in Repair for Earthing complete withgalvanized steel earth plate electrode 60 cmx 60 cm x 6 mm thick buried directlyin ground (earth pit notless than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level,connecting to theGalvanised earth lead wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron andsteelearth wire protected by provision of GI lightgrade pipe40 mmbore including provision of concrete pitmade from PCC ( 1:2:4) type B-1 (using20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angleiron40 x 40 x 6 mm and handle of 6 mmdia MS barmade to shape, GI light grade 20 mmbore pipefor watering perforated atbottom, 1.50metre long placed on top edge of earth plate, common salt &charcoalfilling, withfixing arrangement , funnel, wire mesh and earthwork in hard/dense soil, returning filling in and removal of surplus soilto a distance notexceeding50 metres, all as perelectrical plate No 5 of SSR 2009 Part-I and connecting to Poles all as specified or indicated including testing, complete all as specified and as directed by Engineer-in-Charge. |
| 4 | M&L for restringing of LT OH conductor ACSR including binding of conductor making jumper connection etc., complete all as specified and directed by Engr-in-charge and directed.Note:- One conductor will be measured as one length. |
| 5 | M&L for cutting of tree branches touching or leaning overoverhead power lines and removing of cut tree branches from the site, complete all as specified and as directed by Engineer-in-Charge. |
| 6 | S&F Steel tubular swaged poles completewith cast iron base plate, finial taper plug, bolts, nuts & screws asspecified type 410 SP-31 (9.0 metres long) with dismentling/Taking down existing, complete all as specified and as directed by Engineer-in-Charge. |
| 7 | M&L for cement concerete 1:4:8 type D2( using 40mm grade stone aggregate)cement concrete asin foundation filling and mass concrete for sub base of LT poles, complete all as specified and as directed by Engineer-in-Charge. |
| 8 | M&L for cement concerete 1:3:6 type C2( using 20mm grade stone aggregate)cement concrete asin foundation fillingfor base of LT poles,stay assembly, complete all as specified and as directed by Engineer-in-Charge. |
| 9 | M&L for cement concerete 1:2:4 type B1( using 12.5mm grade stone aggregate)cement concrete asin coping of LT poles, complete all as specified and as directed by Engineer-in-Charge. |
| 10 | Excavation in trenches not exceeding 1.5 mtr wide andexceeding 1.5 mtr in depth (7 cm) for LT poles and stay and getting out soil in Dense/Hard soil, complete all as specified and as directed by Engineer-in-Charge. |
| 11 | Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil, complete all as specified and as directed by Engineer-in-Charge. |
| 12 | Supply,laying and spreading of pea gravell 40mm graded, complete all as specified and as directed by Engineer-in-Charge. |
| 13 | S&F decorative LED type post top(Cool Day white light) lanterns luminaire 30 watts, out door type for 360 degree indirect light with resistant to corrosion, glare free having better uniformity with suitable driver, complete all as specified and as directed by Engineer-in-Charge. |
| 14 | Supply, laying and testinggalvanised steel tube (GI) light grade of size 40 mm (1.5\") bore for standpost of post top/ garden lights, complete all as specified and as directed by Engineer-in-Charge. |
| 15 | S&F in repair FR PVC Sheathed Round , Copper conductor (Flexible) industrial cable , 1100 Volts , conforming to IS: 694 of size 2.5 Sqmm 3 core for connecting including 20 mm PVC conduit in trenches with excavation,return filling and removal of surplus soil not exceeding 50m distance for laying of cable complete including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-Charge. |
| 16 | S & FLED flood light luminaires 100 watts, 230 volts AC, out door type with pressure die cast housing resistant to impact and corrosion, glare free complete with lamp & driver, complete all as specified and as directed by Engineer-in-Charge. |
| 17 | S & FLED flood light luminaires 50 watts, 230 volts AC, out door type with pressure die cast housing resistant to impact and corrosion, glare free complete with lamp & driver, complete all as specified and as directed by Engineer-in-Charge. |
| 18 | S & FLED flood light luminaires 70 watts, 230 volts AC, out door type with pressure die cast housing resistant to impact and corrosion, glare free complete with lamp & driver, complete all as specified and as directed by Engineer-in-Charge. |