| 1 | Demolition of brick work build in cement mortar including all quoins, arches, pillars, complete all as directed |
| 2 | M & L Brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as directed |
| 3 | M&L for 10mm thickrendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as directed. |
| 4 | Preparation of new plastered surfaces of walls using sand paper and applying two coats of cement base paint over a coat of cement base primer complete all as directed. |
| 5 | Preparation of new plasteredsurfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primercomplete all as directed. |
| 6 | Dismantling Asbestos Cement (corrugated, semicorrugated etc) sheets in roof covering complete all as directed. |
| 7 | M & L Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of a colour having tensile strength of 550 Mpa as in ridge, fixed with self tapping screws complete all as directed. |
| 8 | M & L Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as directed. |
| 9 | Dismantling of boarding any description, fixed in any position with screws complete all as directed. |
| 10 | M&L for providing aluminium snap Grid frame work for false ceiling with of size 605X605 mm ,using Main and cross tee of size 36.5mmX25mmX1.4mm, weighing 0.24 kg/RM and 23.5mmX36.4mmX1.4mm weighing 0.191Kg/RM respectively, The snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40mmX25mmX2mm weighing 0.36Kg/RM. The snap grid shall be fixed to ceiling supporting hangers consisting of 2mm dia MS wire/GI wire, J bolts, nuts and washers as per manufacturer\"s instruction complete all as directed. |
| 11 | M & L Non asbestos fibre cement building board 4 mm thick in ceiling fixed or laid/inserted to timber /GI/ Aluminium frame work with screw complete all as directed. |
| 12 | M&L for prepration of old steel surface over 10 mm width or girth and applying one coat of aluminium paint complete all as directed |
| 13 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as directed. |
| 14 | S&F Fe 410 - W (Gde- E- 250) roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavybracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as directed. |
| 15 | M&L Preparation of new iron/steel surfacesand applying twocoats of Aluminiumpaint of any description over 10 cm width or girth when unconnected with other painting or when painted in a different tint including rubbing out over a coat of aluminium red oxide primerComplete all as directed. |
| 16 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete incl fixtures and fittings such as switches, ceiling rose, pendant, regulator, sockets, light fittingetc. removing materials to store for keeping in safe custody or for taking credit (Credit for above items should be as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as directed. |
| 17 | M & L for Point wiring in repair with PVC insulated PVC unsheathed electric (FRLSH) cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling instead of PVC conduit surface casing caping will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including sunk in pressed steel terminal boxes (normal and moduler type) of 1.6 mm thick (duly painted with two coats of black bituminous paint over a coat of red oxide primer in and out sides) with and including plastic laminated bakelite sheet cover of hylam board of 2.8 mm thick including cutting holes for switches, sockets, regulators etc as per requirement including fixing with machine screw, washer etc for the following be completed all as directed |
| 18 | (a) One lightpointcontrolled by oneway switch |
| 19 | (b) One fan pointcontrolledby one way switch |
| 20 | (c) One 3/5 pin socket outlet 5 Amp on the same board with other switches. |
| 21 | (d) One 3/5 pin 5 Amps socket outlet on indepandant board. |
| 22 | S & F sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 4.0 sqmm LT, 1100V grade, down though and incl adequate sizes PVC non metallic conduit of 20mm dia with accessories and fittings and one run of 4 sq mm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm dia shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipecomplete all as directed.Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate. |
| 23 | S&F in replacement switch piano flush type polycarbonate single pole one way 5 Amps complete all as directed. |
| 24 | S&F in replacement socket outlet polycarbonate 2 in 1, 3 pin 5 Amps flush typecomplete all as directed. |
| 25 | S&F in replacement Ceiling rose 3 terminal/PVC/polycarbonate, insulated bodycomplete all as directed. |
| 26 | S&F in replacement stepped type electrronic fan regulator flush typecomplete all as directed. |
| 27 | S&FLamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked) complete all as directed. |
| 28 | S&FLED bulb of capacity10 watts lumen out put (1200) length 102 mm dia 56 mm base cap B22,(ISI marked) complete with all accessories base (ISI marked) complete all as directed. |
| 29 | Allas per item No 17 abovebut in PVC conduit with 2.5 Sqmm (nominal area) FRLSH cable PVC for the 15 Amp 3/5 pinsocket power point including 2.5 Sqmm copper conductor green as colour for earth contineuity complete all as directed. |
| 30 | S&F in replacement switch piano flush type polycarbonate single pole one way 15 Amps complete all as directed. |
| 31 | S&F in replacement socket outlet polycarbonate 2 in 1, 3 pin 5/15 Amps flush type complete all as directed. |
| 32 | S&F LED Tubelight fitting1x18/20 Watt surface and wall mounted LED batten, PVC housing with polycarbonate diffuser & integrated electronic driver complete with all accessories internally prewired and incl connecting upthree core single wire complete all as directed . |
| 33 | S&F for Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar,triple pole and neutral 415volts ,flush to wall including taking down carefully existing UNSV main switches, DBS along with MCBs complete all asdirected. |
| 34 | Supply and fixing 415V 10KA \"B\" curve TPN 63 Amp capacity in the DB complete with connection ,commissioning and testing complete all as directed. |
| 35 | S&F in replacement of double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 415 Volts ,200 amps rated busbar 12 way complete all as directed. |
| 36 | S&F in replacement of double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 415 Volts, 200 amps rated busbar 8 way complete all as directed. |
| 37 | S&F in replacement of double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 415 Volts suitable amps rated busbar4way complete all as directed. |
| 38 | M&L for MCB single pole,6 to 32 Amp 240 volt \"B\" curve 10 KA, IP 20 transparent label holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area completeincluding suitable sizecopper Lugs complete all as directed . |
| 39 | S&F in repair 240V, 10 KA ,\"B\" curve Miniature circuit breakers (MCB) of SINGLE POLE AND NEUTRAL (SPN) and current carrying capacity 32 Amp in the MCB DB with connection, commissioning andtesting complete all as directed . |
| 40 | M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connectingto main switch or switch boardcomplete and incl PCC masonry pit of 300x300x300mm interier diamentions in PCC 1:2:4 type B1 RCC cover with GI frame, charcoal dust and common salt 15cm in layers all round the earth plate, 20mm dia GIwatering pipe, a funnelwith wire mesh should be provided on top of watering pipe complete all as specified as per electric plate No 3 of SSR 2009 including testing after completion complete all as directed . |
| 41 | S&L XLPE insulated armoured heavy duty electric cable with stranded aluminum conductor 1100 volt gradecross sectional area 16 Sqmm and 4 core, including taking down of existing unserviceable service cable complete all as directed . |
| 42 | S&L XLPE insulated armoured heavy duty electric cable with stranded aluminum conductor 1100 volt gradecross sectional area 25 Sqmm and 3.5 coreincluding taking down of existing UG cable complete all as directed . |
| 43 | M&L for laying GI tubinglight grade 40 mm dia with all fittings for cable protection including GI clamps nut bolts and washer etc complete all as directed . |
| 44 | M & L for Excavating in trenches, of soilnot exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on planfor shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as directed . |
| 45 | M & L for Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as directed . |
| 46 | M & L for Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as directed . |
| 47 | M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable complete all as directed .(Note:- Punning thickness shall be measured) |
| 48 | Material and labour for un - reinforced pre cast concrete cable cover class LV, Type - 1 , flat size 250 mm x 150 mm x 40 mmcomplete all as directed . |
| 49 | Supply and fixing building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP 65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic drivertype street light fitting 35 watt capacity LED and including all accessories duly pre-wired, fixing on existing bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall completeincluding taking old street light fitting any type and description complete all as directed . |
| 50 | M&L for bracket made of GI light grade pipe 1.2 Mtr long of size 40 mm bore bend to shape as per site requirement fixed to pole with 40 x 5 MM -02Nos, size clamps bolts, Nuts, washers including painting two coats of aluminium paint over a coat of primercomplete all as directed . |
| 51 | S&F LED in replacement light fitting 1x9W/1x10W bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as directed . |
| 52 | M&L for boring of hole under road, pavement, hard standing by trenchless using manual technique with required tools complete all as directed.Note:- (i)Pipes shall be laid minimum 1.00 mtr to 1.50 mtr below/ under existing road surfaces/ apron/ floors etc.(ii)T&P required for road boring to be provided by the contractor at site own cost and not any extra claim entertained on this account on later stage.(iii)During execution of work any damage occured, contractor must repair/ rectify the same day beyond this @ Rs 500/- per day penalty will be imposed and not any extra claim will be entertained on this account |
| 53 | S&F LED luminaire 600 mm x 600mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as directed . |
| 54 | Taking down exhaust fan / ceiling fan of any sweep after disconnecting all necessary electrical connection from ceiling rose to fan , fan blade and deposit to MES store yard of AGE E/M complete all as directed. |
| 55 | Labour only for refixing the ceiling fan /Exaust fan obtained from taking down with replacement of unserviceable 3 core PVC insulated PVC sheated 3 core multistanded copper conductor cable of size 23/0.193 from ceiling rose to fan terminal including over hailing the fan ,painting of ceiling fan complete with two coat of synthetic enamel paint by spray machine including filling cavaties with filler after cleaning of all dust etc and writting the MES number with synthetic enamel paint complete all as directed. |
| 56 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |