| Sl. No. | Item Description |
| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. seperating serviceable fittings/fixtures, keeping in safe custody reuse under respective item and removal of unserviceable material from site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.Note:- Concealed conduit in RCC slab/beam shall not be not be taken. |
| 2 | Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/description including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 3 | Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as directed. |
| 4 | M&L concealed point wiring for One light point/Ceiling fan/Exhaut fan/bell pointcontrolled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0,7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate flush type regulators] concealed in walls, withwith back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i)Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles.(ii) Cost of cutting chases in wall and making good the distrubed surfaces is deemed to be inclusive in the unit rate quoted(iii)Where concealing of conduit is not feasible i.e. on surface ofRCC roof slab, beam etc, conduit shall be fixed on surface with necessary saddles at no extra cost. |
| 5 | All as per item No 4here-in-above but One socket out let 5/6 amps point on the same board |
| 6 | All as per item No 4here-in-above but One socket out let 5/6 amps point on the independent board |
| 7 | All as per item No 4here-in-above but One Light point controlled by two numbers two way switches 5/6 Amps. |
| 8 | M&L concealed point wiring for One one socket outlet 15 Amps point on independent board pointcontrolled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0.7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate fittings] concealed in walls, withand including back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:- (i)Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. (ii)Where concealing of conduit is not feasible i.e. on surface ofRCC roof slab, beam etc, conduit shall be fixed on surface with necessary saddles at no extra cost.(iii) Cost of cutting chases in wall and making good the distrubed surfaces is deemed to be inclusive in the unit rate quoted |
| 9 | M&L surface point wiring for light/fan/bell, buzzer points controlled by one, one way switch complete controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing cappingmedium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0,7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate flush type regulators] concealed in walls, withwith back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i)Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. |
| 10 | All as per item No 9here-in-above but One socket out let 5/6 amps point on the same board |
| 11 | All as per item No 9here-in-above but One socket out let 5/6 amps point on the independent board |
| 12 | All as per item No 9here-in-above but One Light point controlled by two numbers two way switches 5/6 Amps. |
| 13 | M&L surface point wiring for One socket outlet 15 Amps point on independent board pointcontrolled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing cappingmedium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0,7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate flush type regulators] concealed in walls, withwith back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i)Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. |
| 14 | M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE: (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 15 | M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE: (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 16 | M&L Surface type sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing cappingmedium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE: (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 17 | M&L Surface type sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing cappingmedium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE: (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 18 | S&F Switch piano, flush type single pole, one way 5/6 Amp complete all as specified and as directed. |
| 19 | Fixing only Switch piano,flush type single pole, one way 5/6 Amp complete all as specified and as directed.Note:- Serviceable Piano Switch obtained from Item No 1 here-in-before |
| 20 | S&F Switch piano, flush type single pole, two way 5/6 Amp complete all as specified and as directed. |
| 21 | S&F Bell push, flush type, 5/6 amps, flush type complete all as specified and as directed. |
| 22 | S&F Socket outlet 2 in 1, 3 pin, 5/6 Amps flush type complete all as specified and as directed. |
| 23 | Fixing only Socket any type 5/6 Amp complete all as specified and as directed.Note:- Serviceable Socket obtained from Item No 1 here-in-before |
| 24 | S&F Switch socket combination 2 in 1, 3 pin, 5/6 Amp flush typeuniversal complete all as specified and as directed. |
| 25 | Fixing only Switch socket combination 2 in 1, 3 pin, 5/6 Amp complete all as specified and as directed.Note:- Serviceable Socket obtained from Item No 1 here-in-before |
| 26 | S&F Switch socket combination 2 in 1, 3 pin, 15/16 Amp flush type universal complete all as specified and as directed. |
| 27 | Fixing only Switch socket combination 2 in 1, 3 pin, 15/16 Amp complete all as specified and as directed.Note:- Serviceable Socket obtained from Item No 1 here-in-before |
| 28 | S&F Socket outlet 2 in 1, 3 pin, 15/16 Amps, flush type complete all as specified and as directed. |
| 29 | S&F Switch, flush type, single pole, one way, 15/16 Amps complete all as specified and as directed. |
| 30 | S&F ceiling rose, 3 phase PVC/ polycarbonate, insulated body, three terminals, complete all as specified and as directed |
| 31 | Fixing only ceiling rose any type complete all as specified and as directed.Note:- Serviceable Socket obtained from Item No 1 here-in-before |
| 32 | S&F step type electronic fan regulator flush type (05 steps) complete all as specified and as directed. |
| 33 | Fixing only fan regulator any type complete all as specified and as directed.Note:- Serviceable regulators obtained from Item No 1 here-in-before |
| 34 | S&F lamp holder, insulated PVC/ Polycarbonate body, with back plate suitable for batten/anglefittings complete all as specified and directed. |
| 35 | Fixing only lamp holder, any type complete all as specified and as directed.Note:- Serviceable lamp holder, obtained from Item No 1 here-in-before |
| 36 | S&F Call Bell, AC, 230 volts, single pole complete all as specified and as directed. |
| 37 | S&F LED bulb 10 watt5 STAR LAMPwith B 22 base capacity 1200 lumencomplete all as specified. |
| 38 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), IP-43 doubledoor, Single pole & neutral with 200 Amps rated bus bar, 240 Volts,IP-43 protection,complete including. blanking plates as required &flush to wall/other surface complete all as specified and as directed. |
| 39 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 doubledoor, Single pole & neutral with 200 Amps rated bus bar,240 Volts, IP-43 protection,complete including. blanking plates as required &flush to wall/other surface complete all as specified and as directed. |
| 40 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 doubledoor, Triple pole & neutral with 200 Amps rated bus bar,240 Volts, IP-43 protection,complete including. blanking plates as required &flush to wall/other surface complete all as specified and as directed. |
| 41 | S&FMCB, TPN, C Series 415 Volts, 63 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 42 | S&FMCB, SPN, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 43 | S&F MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 44 | S&F LED luminarie tube light fitting basic all purpose surface/wall mounted decrotative slim with polycarbonate housing & integrated electronic driver, 4 feet LED with high efficient LEDs 20 watt, (or nearest next higher wattage) 6500K, with all accessories, suitable for operation on AC, single phase 220/230 Volts, 50 Hz, 6500K complete all as specified and as directed. |
| 45 | S&F energy saving & environment friendly long life 20 Watt,(or nearest next higher wattage)CT ≥ 6500 K, LED building security light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete withintegrated type, with high efficiency electronic driver, surge suppressor of 5 KV or more & high brightness LEDs, luminaire efficacy > 110 lumens/Watt, power factor ≥ 0.90, operating range 140 to 270 V, 50 Hz complete including GI pipe bracket of adequate size as required (Light Grade) of length 1.2 mtrs bent to shape and fixed with 40mm x 5mm MS flat with necessary nuts, bolts, washers etc, painting with two coats of syntheic enamel paint over a coat of primer and connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed. |
| 46 | S&F LED luminarie tube light fitting basic all purpose surface/wall mounted 2 feet LED batton with polycarbonate housing & integrated electronic driver, with high efficient LEDs 9 watt, (or next nearer higher watt) with all accessories, suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply,complete all as specified and as directed. |
| 47 | S&F in repair, LED bulb 10 watt5 STAR LAMPwith B 22 base capacity 1200 lumencomplete all as specified. |
| 48 | S&F Bulk head LEDfitting with injection molded Polycarbonate housing suitable for 10 Watt (or nearest next higher wattage)with IP 66 protection & impact resistance not less than IK-10 complete withintegrated type, with high efficiency electronic driver, & high brightness LEDs, luminaire efficacy > 100 lumens/Watt, power factor ≥ 0.95, operating range 140 to 270 V, 50 and connecting complete all as specified and as directed. |
| 49 | S&F in repair, ceiling fan capacitor 2.25 mfd as per site requirement heavy duty with metal body complete all as specified and directed. |
| 50 | S&F in repair, ceiling fan capacitor 2.5 mfd as per site requirement heavy duty with metal body complete all as specified and directed. |
| 51 | S&F in repair, ceiling fan capacitor 3.15 mfd as per site requirement heavy duty with metal body complete all as specified and directed. |
| 52 | S&F in repair, ceiling fan capacitor 4 mfd as per site requirement heavy duty with metal body complete all as specified and directed. |
| 53 | S&F in repair, ceiling fan capacitor 6 mfd as per site requirement heavy duty with metal body complete all as specified and directed. |
| 54 | Taking up the existing unservicable UG cable of any type/ description as existing at site complete all as directedNote :Earthwork will be measured and paid seperately. |
| 55 | RelayingServiceableLT UG XLPE cable of size 3.5core x 35/50 sq mm obtained from item no. 53 laid in trenches/ floors/ on wall/ service connectionsafter cutting and jointing through Cable Joint kit as per site requirement including connecting to the main switches/ cut outs MCB/ MCCBwith necessary lugs after cutting to required length of cable all as specified and directed. Note:- Serviceable Cable obtained from Item No 54 here-in-before |
| 56 | RelayingServiceableLT UG XLPE cable of size 3.5core x 16/25 sq mm obtained from item no. 53 laid in trenches/ floors/ on wall/ service connectionsafter cutting and jointing through Cable Joint kit as per site requirement including connecting to the main switches/ cut outs MCB/ MCCBwith necessary lugs after cutting to required length of cable all as specified and directed. Note:- Serviceable Cable obtained from Item No 54 here-in-before |
| 57 | Supply,laying and testing cable XLPE Insulated,screened,PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Polewith necessary lugs complete all as specified and as directed.Note:- Serviceable Cable obtained from Item No 54 here-in-before |
| 58 | Supply,laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Polewith necessary lugs complete all as specified and as directed. |
| 59 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 2 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Polewith necessary lugs complete all as specified and as directed. |
| 60 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables etc and getting out in soft/loose soil complete all as specified and as directed. |
| 61 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed. |
| 62 | Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed. |
| 63 | M&L sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed. |
| 64 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trenchcomplete all as specified and directed. |
| 65 | M&L 40mm bore GI pipe light grade with all necessary fittings (ISI marked), clamps, nuts bolts etc as required as in cable protection fixed to pole,laid in trenches/road/floor complete all as specified and as directed. |
| 66 | S&F in repair PVC square box 100mm x 100mm including refixing of old switch socket complete all as specified and as directed. |
| 67 | S&F in repair PVC square box 170mm x 100mm including refixing of old switch socket complete all as specified and as directed. |
| 68 | S&F in repair PVC square box 200mm x 150mm including refixing of old switch socket complete all as specified and as directed. |
| 69 | S&F in repair PVC square box 300mm x250mm including refixing of old switch socket complete all as specified and as directed. |
| 70 | S&F in repair 25x16mm, medium grade, PVC casing and capping duly fixed with casing pins and connecting accessories like Tee , Bends , elbow etc required as per site complete all as direced. |
| 71 | S&F in repair 25mm dia medium grade PVC Conduitduly fixed with Clamps on wall surfacesand connecting accessories like Tee , Bends , elbow etc required as per site complete all as direced. |
| 72 | M&L earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means ofbolts & nuts,check nuts & washers made of galvanised steel, earth wire protected by and including PCC (1:2:4) type B1 precast RCC cover slab(1:2:4, type B1)reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth wire GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion including dismantling/taking out old unserviceable earthing complete all as specified and as directed. |
| 73 | Refixing surface point wiring for light/fan/bell, buzzer points controlled by one, one way switch complete controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed cable 1100 volts grade with proper colour coding drawn through and including non-metallic rigid PVC casing cappingmedium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i) Serviceable wire andsuken terminal box made out of MS sheet steel for boxes obtained from item No. 1 here-in-before shall be reused (ii) Cost of PVC casing capping with accessories is deemed to inclusive in Unit rate Quoted(iii) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. |
| 74 | All as per item No 73here-in-before but One socket out let 5/6 amps point on the same board |
| 75 | All as per item No 73here-in-before but One socket out let 5/6 amps point on the independent board |
| 76 | Description all as per item No 72 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 2.5 sqmm multi stranded copper conductor as continuous earth wire with lugs complete all as specified and directed. |
| 77 | Fixing only Sheet metal enclosure for 4/6/8/12 way Distribution Boards (DB’s), doubledoor, Single pole & neutral with 200 Amps rated bus bar, 240 Volts,IP-43 protection,complete including. blanking plates as required &flush to wall/other surface complete all as specified and as directedNote:- Serviceable SPN DB\"s obtained from item No. 2 here-in-before shall fixed |
| 78 | Fixing only Sheet metal enclosure for 4/6/8/12 way Distribution Boards (DB’s), doubledoor, Triple pole & neutral with 200 Amps rated bus bar, 414 Volts,IP-43 protection, complete including. blanking plates as required &flush to wall/other surface complete all as specified and as directedNote:- Serviceable TPN DB\"s obtained from item No. 2 here-in-before shall fixed |
| 79 | Fixing onlyMCB, FP, 63 Amps complete all as specified and as directedNote:- Serviceable MCB\"s obtained from item No. 2 here-in-before shall fixed |
| 80 | Fixing onlyMCB, SPN, 6-32 Amps complete all as specified and as directedNote:- Serviceable MCB\"s obtained from item No. 2 here-in-before shall fixed |
| 81 | Fixing onlyMCB, SP, 6-32 Amps complete all as specified and as directedNote:- Serviceable MCB\"s obtained from item No. 2 here-in-before shall fixed |
| 82 | Fixing only Earth and Plug socket with MCB of any rating and flush to wall/other surface complete all as specified and as directedNote:- Serviceable Earth Plug obtained from item No. 2 here-in-before shall fixed |
| 83 | Refixing Surface type sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire,PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing cappingmedium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE:(i) Serviceable wire obtained from item No.3 here-in-before shall be reused (ii) Cost of PVC casing capping with accessories is deemed to inclusive in Unit rate Quoted (iii) Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (iv) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 84 | Refixing Surface type sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire,PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing cappingmedium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE: (i) Serviceable wire obtained from item No.3 here-in-before shall be reused (ii) Cost of PVC casing capping with accessories is deemed to inclusive in Unit rate Quoted(iii) Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (iv) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 85 | Fixing onlyLED luminarie, of any waatage complete all as directedNote:- Serviceable Light fittings obtained from item No. 1 here-in-before shall fixed |
| 86 | Taking down and Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as directed |
| 87 | Taking down and Fixing only exhaust fan and connecting up including provision of cable from ceiling rose/ connector to fan complete all as directed |
| 88 | S&F in repair PVC insulated sheathed multicore cable copper conductor 1.00 Sqmm, 2 Core complete all as specified and as directed |
| 89 | S&F in repair PVC insulated sheathed multicore cable copper conductor 1.50 Sqmm, 3 Core complete all as specified and as directed |
| 90 | S&F in repair PVC insulated sheathed multicore cable copper conductor 2.50 Sqmm, 3 Core complete all as specified and as directed |
| 91 | S&F Modular Switch 1 way 6 Amps, 1 module, complete all as specified and directed. |
| 92 | S&F Modular Switch 1 way 16 Amps, 1 module, complete all as specified and directed. |
| 93 | S&F Modular Socket 6 Amps, 5 pin, 2 module, complete all as specified and directed. |
| 94 | S&F Modular Socket 6 A/ 16 Amps, 6 pin combined 2, complete all as specified and directed. |
| 95 | S&F ModularBell Push Switch 1 way 6 Amps, 1 module, complete all as specified and directed. |
| 96 | S&F Modular Blank plate, 1 module, complete all as specified and directed. |
| 97 | S&F Modular fan regulator, step type, 120 watt, 2 module, complete all as specified and directed. |
| 98 | S&F Modular Switch two way 5/6 Amp, 1 module, complete all as specified and directed. |
| 99 | S&F in repair, VTPN DB, 08 Way, double door,Metal door ,IP-43 IK 09, with MCCB as (upto 125 Amps)incomer, and MCB;s as Outgoing , 250 Amps rated copper bus bars,earth bar,neutral links, no. of module complete including blanking plates as required & fixed flush to wall and making good the disturbed surfaces includingcomplete all as specified and as direct. Note:- MCCB;s/MCB\"s required as Outgoing shall be measured and pair seperately under appropiate items |
| 100 | S&F in repair, MCCB 4P 125 Amps,thermal magnetic release, 415V ,50 Hz ,breaking capacity 25 KAcomplete all as specified and as direct. |
| 101 | S&F in repair, MCCB 4P 100 Amps,thermal magnetic release, 415V ,50 Hz ,breaking capacity 25 KAcomplete all as specified and as direct. |
| 102 | S&F in repair, Cable jointing kit LT 1100 Volts cable End joint kit complete with jointing material and accessories suitable for 25 Sqmm to 50 Sqmm, 3.5 coreXLPE armoured aluminium conductor cable including testing after jointing, complete all as specified as directed. |
| 103 | Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 40mm bore (dia) for passing of pipes, complete all as specified and as directed.Note:- Pipe will be measured and paid seperately under appropiate item |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail