| 1 | Material and labour for posts, struts, grills/gratings, ladders and stair case (including treads and risers) purlins, rafters in roof work, hold fasts wind tie and similar works conforming to Fe-290 Gde-E-165 with and including necessary drilling holes as per site requirement with ends of bars welded, shouldered, riveted or forged into spike duly embedded in brick or concrete walls including cutting holes into walls of any description in any location/situation complete all as specified and directed.Note:- Provision of PCC shall be measured and paid separately under appropriate item catered herein after. |
| 2 | Material and labour for welded steel wire mesh of size 100x100mmx3.40mm diameter cut to length bent to shape required as per site requirement welded to frame work with and including painting with two coats of synthetic enamel, gelled paint over and including priming coat of red oxide in location/situation complete all as specified and directed. |
| 3 | Painting with two coats of synthetic enamel paint of approved brand and manufacture with and including one priming coat of red oxide on new steel surfaces complete all as specified and directed. |
| 4 | Supply and fixing for 15mm bore steel water tubing galvanised, medium grade including all fittings fixed to walls and ceiling or in floor/roof top and shaft complete with necessary fittings with and including taking up or down steel tubing and connections any location and any height (G+3) buildings complete all as specified and directed. |
| 5 | Supply and fixing for 20mm bore steel water tubing galvanised, medium grade including all fittings fixed to walls and ceiling or in floor/roof top and shaft complete with necessary fittings with and including taking up or down steel tubing and connections any location and any height (G+3) buildings complete all as specified and directed. |
| 6 | Supply and fixing for glass reinforced 2mm thickness translucent plain/corrugated sheeting (colour and shade as approved by GE) with proper side lap fixed in position with and including necessary nuts and bolts with rubber washers complete all as specified and directed. |
| 7 | Dismantling old plaster or skirting raking out joints carefully at any location on any floor (G+3) and removal of all the debris/waste material upto ground level for further disposal under item serial no 14 here is below complete all as specified and directed. |
| 8 | Material and labour for 15 mm thick cement plaster (1:4) on fair faces of brickwork/concrete surfaces at any location and any height (G+3) buildings finished even and smooth without using extra cementcomplete all as specified and directed. |
| 9 | Distempering with of first quality acrylic emulsion of approved brand and manufacture to give an even shade (two or more coats) over and including water thinkable priming coat with cement primer VOC content less than 50 gm/litrecomplete all as specified and directed. |
| 10 | Providing and laying for cement concrete 1:2:4 type B-1 in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers abatements pillars, posts, struts, buttresses, string or lacing courses parapets coping bed blocks, anchor blocks plain window sills, fillets, sunken floor etc. and similar works up (G+3) level building with and including necessary scaffolding and requisite safety measures’complete all as specified and directed. |
| 11 | Materials and labour for 100 mm MS but hinge medium weight cold rolled fixed in position welded to steel frame work as per site requirement complete all as specified and directed. |
| 12 | Demolition of brick/block masonry built in CM including all quoins, arches, pillars etc carefully in balconies etc at any location on any floor (G+3) and removal of all the debris/waste material upto ground level for further disposal under serial items no 14 here is below and including necessary scaffolding and requisite safety measures complete all as specified and directed. |
| 13 | Material and labour for brick work with subclass B bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) in balconies at any location and any height (G+3) buildings and including necessary scaffolding and requisite safety measures complete all as specified and directed. |
| 14 | Removal/disposal of building rubbish debris melba and other unserviceable/waste material obtained from demolition/dismantling out of the campus(MoD land) and depositing at the location approved by local municipality and including necessary scaffolding and requisite safety measures complete all as specified and directed. |
| 15 | Dismantling completely RCC water tanks including covers any capacity on any floor (G+3) carefully and removal of all the debris/waste material upto ground level for further disposal under serial item no 14 above. |
| 16 | Material and labour for 250 mm long mild steel sliding door bolt plate type stove enamelled black with bright bold not less than 12mm dia with bolt and staple plates welded to steel frame work as per site requirement and including necessary scaffolding and requisite safety measures complete all as specified and directed. |