| Sl. No. | Item Description |
| 1 | Sch \"A\" Part-I (B/R Works)Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thick (below or above ground level), complete all as specified and directed. Note: No extra cost to be borne by govt in r/o flooring overleaped with tile incl screed .Thickness to be considered as total thickness of overleaping. |
| 2 | Demolition of Reinforced cement Concrete in Roofs,floors ( other than ground floors), beams,staircases,landings,chajjas,lintel band and similar suspended works.(reinforcement cut as required to facilitate demolition), complete all as specified and directed. |
| 3 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 4 | Demolition of Brick/stonework built in cement morter of any descrption incl all necessary quions arches piilars etc, complete all as specified and directed. |
| 5 | Dismantling of plain or corrugated steel sheeting or any other type, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.Note:-Old Sheet dismantled shall be stacked properly without any damage for refixing if serviceable sheets damaged during dismantling,then contractor should arrange pre painted sheets at its own cost and no extra cost shall be claimed. |
| 6 | Dismantling of mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 7 | Dismantling of existingPVC water tank exc 500 litres and n.exc 1000 ltrs capaicty and removing to store, complete all as specified and directed. |
| 8 | Dismantling of existing false ceiling of any type etc, complete all as specified and directed. Note :Retrieved material after dismantling shall be stored and stacked properly for refixing. |
| 9 | Taking down cement plaster on brick/stone or conc surfaces including racking out joints hacking for key to any thicknessscrubbing down with water etc, complete all as specified and directed.Note :No extra cost shall be borne by Govt exchequer for any no of layers over leaping of tiles / mosiac finish. |
| 10 | Taking down chowkhats with shutter (without taking off from shutter) exc 1.5 sqm and n exc 4 sqm each and removing to store and making good to surface disturbed due to taking down, complete all as specified and directed. |
| 11 | Taking down chowkhats with shutter (without taking off from shutter) n exc 1.5 sqm each and removing to store, complete all as specified and directed. |
| 12 | Taking down door shutter of any description exc 1 sqm but not exc 2sqm and refixing in the same opening, complete all as specified and directed. |
| 13 | Hacking out old broken glasses (Any thickness, size quality, description) from wooden or steel frames fixed with putty or wooden beads, complete all as specified and directed. |
| 14 | Taking down GI water tubing of 15 mm bore and connection and incl cleaning for refixing or removel, complete all as specified and directed. |
| 15 | Taking down GI water tubingof 20 mm bore and connection and incl cleaning for refixing or removel, complete all as specified and directed. |
| 16 | M&L for brick work in cement mortar (1:6) using old size sub class \"B\" bricks in walling, straight or curved on plan exc 6m mean radius, complete all as specified and directed. |
| 17 | All as per Item No 16.00 here-in-before but except bricks. |
| 18 | M&L for stone walling random rubble, uncoursed, well bonded bedded and solidly hearted,built in cement mortar 1:6, complete all as specified and directed. |
| 19 | Extra over stone walling, random rubble brought upto courses, for hammer dressing to face stones and dressing of face beds and joints, with maximum depressions on face from straight edge held against the dressed surface not exc. 40 mm on lime or sand stone, complete all as specified and directed. |
| 20 | Formwork to sides and soffits of floor or roof beam, beam hunching, girders, lintel, cantilevers, shelves including suports,overhangs etc, complete all as specified and directed. |
| 21 | M & L for mild steel TMT bars 10mm dia and over, cut to length, bend to shape required, including cranking ,bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. |
| 22 | All as per Item No 21.00 here-in-before but 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders. |
| 23 | M&L for RCC 1:2:4 type B1 (using 20 mm graded stone aggregate) for Beams, cantilevers, bressumers, lintel over 1.5 m span, complete all as specified and directed. |
| 24 | S&F Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. confirming to Fe 290 (grade E-165). (cut to ordinary lengths i.e. within 20mm of the length indicated), complete all as specified and directed. |
| 25 | Erection and fixing only steel work in main and cross beams jack rafters, purlines where connected to common rafters and running rails and fixed with angle cleats or other connecting plates completeconfirming to IS 1161-1979 grade St-240, complete all as specified and directed. |
| 26 | S&F Plates (plain or chequered ) channels square cut ornotched oridinary or counter sunk forming holes w/o any attatchment confirming to Fe-290 grade-165, complete all as specified and directed. |
| 27 | S&F Mild steel bolts.exc. 5 cm lengthnot exc. 10 cm length (machine made) with hexagonal or square heads at one end and screwed the other , or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut 11 to 15 mm neck dia, complete all as specified and as directed. |
| 28 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugatedsheet 0.50mmthick of approved colour having tensile strength 550 MPa as in roof covering/ cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed. |
| 29 | Fixing only Pre-painted galvalume aluminium zinc coating GI based corrugatedsheet 0.50mmthick of approved colour having tensile strength 550 MPa as in roof covering/ cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed.Note-Sheet obtained from item No.05 shall be used for refixing. |
| 30 | S&F for Pre-painted galvalume aluminium zinc coating GI based plainsheet 0.50mmthick of approved colour having tensile strength 550 MPa as in ridges, hips, valley gutters fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed. |
| 31 | Supply and fixing of 4mm thick designer ceiling board (Make \" Everest/Ramco/Gyproc\" Hill & Lake Pattern) in ceiling fixed with screw as per manufacturers instructions , laid on hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white.The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet & of size 24 x 32 x 300 mm spaced at 12 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres.Hangers of GI wire 4 mm dia to be fixed by approved rowl plug, level adjusters andscrews etc.The last hanger at the end of each main runner shall not be grater than 450 mm from adjustacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to from 1200 x 600 mm modulescross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturction, complete all as specified and as directed. |
| 32 | All as per item No 31.00 here-in-before but except material. Note : (i)Ceiling boards & other material shall be used as obtained from Item No.8.00 here-in-before. (ii) If contractor damages ceiling board intentionally then recovery of damaged boards shall be carried out as per directions of Engr-in-Charge. |
| 33 | M&L for 10 mm thick rendering in cement mortar (1:6) onnew fair faces of brick/ concrete surfaces of walls, finished even & smooth without using extra cement and using WPC, complete all as specified and directed.Note: WPC shall be measured and paid separately. |
| 34 | M&L for15 mm thick rendering on fair faces of brick /concrete surfacesin cement mortar 1:4 and finishedeven and smooth without using extra cement, complete all as specified and directed. |
| 35 | M&L for rendering 20 mm thick plastering on stone masonry surfacein CM (1:6)and rendering is to be finished even and smoothw/o using extra cement, complete all as specified and directed. |
| 36 | All as per Item No 35.00 here-in-before but in CM 1:4 (external surfaces). |
| 37 | Supply only Liquid water proofing compound conforming to IS, complete all as specified and directed. |
| 38 | M&L for Cement concrete type C-2, 1:3:6 (40mm graded aggregate) 75 mm thick as in plinth protectionlaid in slope 1:12 from outer edge of the wall finished even and fair ,laid in alternate bays including providing 6 mm wide joints through out the thickness of plinth protection in concrete bays and in between walling and plinth protection,joint filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight), complete all as specified and directed. |
| 39 | M&L for 25 mm thick cement concrete type B-0 (1:2:4( (using 12.5 mm graded coarse aggregeate) as in levelling course to floor finishes, complete all as specified and directed. |
| 40 | M&L for 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes, complete all as specified and directed. |
| 41 | M&L for 15mm thick rendering on fair faces of brick works in cement mortar 1:4 finished rough for receiving tiles as in dado and skirting, complete all as specified and directed. |
| 42 | M&L for PCC 1:2:4 type B-0 using 12.5 mm gradedaggregate as in hollow portion of pressed steel frame, complete all as specified and directed. |
| 43 | M&L for PCC 1:2:4 type B-1 using 20 mm gradedaggregate as in bed blocks, bed blocks of hold fasts, coping, PCC cill etc including necessary form work, complete all as specified and directed. |
| 44 | S&F vetrified ceramic tiles inlight shade of size 600x600x8-10 mm thick as in floor set and jointed in neat cement slurry and pointing with white or coloured cement to match the colour of tiles, complete all as specified and directed. |
| 45 | All as per item No 44.00 here-in-before but as in skirting/ dado. |
| 46 | S&F 18-20 mm thickmachine cut kota stone slab (area of each slab nexc 0.27 Sqm except space constraint)in flooring laid and jointed with grey cement slurry Mixed with pigment to match the shade of the slab incl rubbing and mirror polishing, roughing the surface over and including 15mm thick screed bed in cm (1:4) and including dismantling of old existing kota stone flooring, complete all as specified and directed. |
| 47 | Description all as per item No 46.00 here in before but as in riser to steps, skirting ,dado,window cills over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed. |
| 48 | M&L for colouredNon skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe colour of tiles, complete all as specified and directed. |
| 49 | M&L for coloured Glazed ceramic tiles on vertical surface (600 x 300 x 7mm thick ) set and jointed in neat cement slrry and pointed in white or coloured cement to matchthe colour of tiles, complete all as specified and directed. |
| 50 | M&L for 16 to 18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms,shelves and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite, complete all as specified and directed. |
| 51 | Providing edge moulding to 16-18mm thick granite stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc, complete all as specified and directed. |
| 52 | S&F Factory made MS tubular Box type windowof MS rolled steelsection conforming to IS-1038 and shall be ISI marked manufactured by ISI approved manufacturer, openable frames shall be fabricated of sections as approved by GE, corner welded to form a solid fused welded joint handles shall be of z section welded with openable frame box steel section(Consisting of both shutter glazed shutter and gauge shutter complete) used in outer frame shutter frame and central frame shall be ERW section of 16 gauge with fixing lugs to be fixed as per provision of IS-1038except that top lugs shall not be provided , all shutters of windows shall be provided with 4 Nosfriction free hinges, 2 Nos 75 mm tower bolts to each leaf of window one at top and one at bottom welded on 3 mm thick steel sheet piece of suitable size which shall be in turn welded to z section f steel window to provide suitable arrangement of using tower bolt and 1 nos bow handle in each shutter. Glazed shutter and , gauged shutter of window , mild steel casement stays 300 mm with hinged joint and two plates with studs complete all as specifiedwith all fittings and fixtures without glazing bars, 3mm sheet glass in glazedshutter and , GI wire mesh,of 0.56 nominal dia and average width of aperature 1.18 mm in gauged shutter, etc, complete all as specified and directed. |
| 53 | S&F guard bars/grills as specified in between glazed and fly proof window shutter(sand witching guard bars/grill) as per drg No CEPZ/TD-325/07 dt 04.12.07 primer coated, complete all as specified and directed. |
| 54 | S&F Pressed steel frames (size- 125x60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc, complete all as specified and directed. |
| 55 | S&F Plain framed, panelled shutters (any number of panels) with pannel of timber flat on both sides (feather edged) or ofveneered particle boardwith commercial face veneers 35 mm thick 2nd class hard woodsupplied and fitted to chowkats, complete all as specified and directed. |
| 56 | M&L for 35 mm thick second class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze,etc, (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass, etc, size of members of shutter as specified in SSR Part-I, Section 8, clause 8.20 (a),fitted to chowkats, complete all as specified and directed. |
| 57 | S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain coloured PVC sheet, reinforced with MS square tube supplying and fixing in opening as per specification and drawing, complete all as specified and directed. . |
| 58 | M&L for factory made solid panel PVC shutter 30 mm thick ( style ) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘ C’ channelhaving a PVC sheet strip 20 mm width struck inside with solvent cement for style and plain colour PVC sheet for top rail lock rail and bottom rail on either side and as gap inserts for top and bottom rail paneling of plain, colour PVC sheet to be fitted in the MS frame welded / sealed to the styles and rail with suitable PVC sheets beading and jointed together with solvent cement S&F in frame at site as per specification and drawing in SSR part-II and as per sample kept in office of AGE B/R, complete all as specified and directed. |
| 59 | S&F 300mm long ordinary rat tail rod pattern springs including roller plate, complete all as specified and directed. |
| 60 | S&F 2nd class hard wood small fitting such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary laboures articles n.exc 200cu.cm each, complete all as specified and directed. |
| 61 | S&F stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks of galvanised wire staples, complete all as specified and directed. |
| 62 | S&F Aluminium handles, cast type, anodised 150mm long, complete all as specified and directed. |
| 63 | S&F aluminium, anodised barrel tower bolts of extruded section and fixed of size200 mm long, complete all as specified and directed. |
| 64 | S&F aluminium alloy anodised sliding door bolt with fixing bolts and sliding bolts of extruded section or cast aluminium alloyand fixed of size200 mm, complete all as specified and directed. |
| 65 | S&F Anodised aluminum 100mm size butt hinges, extruded aluminum alloy ISI marked, complete all as specified and directed. |
| 66 | S&F 3 mm Sheet glass ordinary quality and glazing with oil putty in square n exc. 0.5 sqm in each pane, complete all as specified and directed. |
| 67 | S&F Curtain Rod of stainless steel 25 mm dia fancy type complete and with steel ball, hanging hooks/brackets / end caps of length 1.5 mtr to 1.8 mtr, complete all as specified and directed. |
| 68 | M&L for steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore 15 mm, complete all as specified and directed. |
| 69 | S&F steel water tubing medium grade galvanised with all fittings including short lengths, laid in trenches complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 20 mm, complete all as specified and directed. |
| 70 | Fixing only in repairs 15 mm dia old galvanized pipes incl new fittings where necessary fixed complete to wall and ceiling or laid in floors, complete all as specified and directed. |
| 71 | Fixing only in repairs 20 mm dia old galvanized pipes incl new fittings where necessary fixed complete to wall and ceiling or laid in floors, complete all as specified and directed. |
| 72 | S&F in repair Bib tap (ISI Marked), cast copper alloy with crutch or butterfly handle, chromium plated fancy type screwedfor iron pipe, suitable for 15 mm bore, complete all as specified and directed. |
| 73 | S & F in repair Ball valves high pressure20mm dia of PTMT with epoxy coated Aluminum rod and high density plastic ball screwed for iron pipe and fixed ( Min wt20mm 210 grms), complete all as specified and directed. |
| 74 | S&F in repair Stop valve cast (ISI Marked), copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm dia pipe, complete all as specified and directed. |
| 75 | S&F in repair Stop valve fancy type brass CP (ISI Marked), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm dia pipe, complete all as specified and directed. |
| 76 | S&F in repair stop valve 20 mm dia cast copper alloy, secrewed down high pressure, with crutch or butterfly handle secrewed both ends for iron pipe and fixed, complete all as specified and directed. |
| 77 | S&F in repair pillar tap chromiumplated fency type 15mm bore, complete all as specified and directed. |
| 78 | S&F in repair15 mm bore Brass CP wall mixer for mixing hot and cold water screwed down for iron pipe and fixed, complete all as specified and directed. |
| 79 | S&F in repair vitreous china WC Orissa pattern white with integral foot rest of size 580x 440 mm including,PCC bedding in 1:2:4 and making good disturbed floor connecting to trap and flush pipe, complete all as specified and directed. |
| 80 | Supply only PVC low level flushing cistern 10 ltrs capacity white with inlet ball value, float valve and handle incl brackets, PVC flush pipe, complete all as specified and directed. |
| 81 | S&F PVC (SWR) P trap 110/110 mm bore, complete all as specified and directed. |
| 82 | S&F PVC connection 15 mm x 450 mm including brass check nut at both ends screwed for iron pipe of 15 mm bore, complete all as specified and directed. |
| 83 | M & L for 75 mm PVC (SWR) floor trap, plain with grating including jointingwith solvent cement, complete all as specified and directed. |
| 84 | S&F in repair PVC SWR pipes 110 mm bore single socketed in any length with rubber ring joint fixed to or laid in trenches or in floors,walls with steel clamps, complete all as specified and directed. |
| 85 | S&F in repair PVC SWR pipes 75 mm bore single socketed in any length with rubber ring joint fixed to or laid in trenches or in floors with steel clamps, complete all as specified and directed. |
| 86 | S&F in repair 110 mm bore PVC (SWR) bend any radius, complete all as specified and directed. |
| 87 | S&F in 110 mm bore PVC (SWR) reducer, complete all as specified and directed. |
| 88 | S&F in 75 mm bore PVC (SWR) vent cowl, complete all as specified and directed. |
| 89 | S&F in repair brass chromium plated shower rose of size 125mm with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and directed. |
| 90 | S&F tubular towel rail 20mm dia, D type, chromium plated 60cm long between flanges, complete all as specified and directed. |
| 91 | S&F wash basin of size 550x400mm, vitreous china (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand, complete all as specified and directed. |
| 92 | S&F 32mm waste fittings, brass, chromium plated for glazed ware basins, etc with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed, complete all as specified and directed. |
| 93 | S&F SS Grating of 100 mm dia, fixed in repairs, complete all as specified and directed. |
| 94 | S&F stainless steel soap dish with and including rowel plugs and SS screws, complete all as specified and directed. |
| 95 | S&F six peg set with 4 mm thick base plate stain less steel fixed with and including rowel plugs and stainless steel screws, complete all as specified and directed. |
| 96 | S&F glass corner shelf with chromium plated guard rails fiexed with and including stain less steel screws and rowel plugs, complete all as specified and directed. |
| 97 | S&F sheet glass bevelled edge mirror of selected quality glass of size 450 x 600mm and 5 mm thick sheet glass mounted to walls with fasteners or plugs of selected quality including removal of existing broken/ unserviceable glass mirror any size, complete all as specified and directed. |
| 98 | S&F Rotational moulded polythene water storage tank (cylindrical vertical with closed top)hoisted and fixed in position of 1000 ltrs capacity with and including tank nipple, complete all as specified and directed.Note : The water tank shall be double layer IS Marked duly embossed on face and weight as per IS Specifications. |
| 99 | Preparing newly plastered surface of walls and applying two coat of oil bound distemper, complete all as specified and directed.Note-Painting shall be done by Painting roller. |
| 100 | M&L for 2 mm thick wall care putty on wall, complete all as specified and directed. |
| 101 | M&L preparing new wall surfaces and applying two coats of cement base paint, complete all as specified and directed.Note-Painting shall be done by Painting roller. |
| 102 | Complete reomoval of existing treatment from walls, by using mechanical equipment (Electric sander ) and preparation of surface to receive the treatment and applying two coats of distemper oil emulsion, complete all as specified and directed. Note : Once the surface is cleared off old treatment completely, the stage for treatment shall be approved by Eng-in-Charge. |
| 103 | M&L preparing old wall plastered or unplastered surfaces and applying one coat of cement base paint, complete all as specified and directed.Note-Painting shall be done by Painting roller. |
| 104 | M&L for two coats of synthetic enamel paint on new steel surfaces over a coat of zinc chrome primer including preparation of surfaces of any description over 10cm in width or girth, not otherwise described, complete all as specified and directed. |
| 105 | M&L for one coat of synthetic enamel painton old steel surfaces including preparation of surfaces of any description over 10cm in width or girth, not otherwise described, complete all as specified and directed. |
| 106 | M&L for two coats of synthetic enamel paint on new wooden surfaces of any description over 10cm in width or girth, not otherwise described including preparation over a coat of pink primmer, complete all as specified and directed. |
| 107 | M&L for one coat of synthetic enamel paints overold wooden surfaces including preparation of surfaces, complete all as specified and directed. |
| 108 | M&L for applying three coats of white washing on wallsincluding preparation of newly plastered surfaces of walls, complete all as specified and directed. |
| 109 | M&L for one coat of Black paint for writing letters on surfaces of any description wood,steel, iron, concrete, brick,stone etc exc 10 cm width or girth, complete all as specified and directed. Note- Letter writing/Painting shall be done at any height as directed by Engr-in-Charge. |
| 110 | M&L for re-writing and repainting of letter or figures (Block, Roman, Italic or Indian)n exc 30 cm high with synthetic enamel paint of any colour, complete all as specified and directed. Note- Letter writing/Painting shall be done at any height as directed by Engr-in-Charge. |
| 111 | M&L for re-writing and repainting of Stops, Commas, Short lines, Dashes,Hyphens, Brackets by using synthetic enamel paint of any colour, complete all as specified and directed.Note- Letter writing/Painting shall be done at any height as directed by Engr-in-Charge. |
| 112 | M&L for 75mm thick Cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub base of floors,Pavings complete all as specified and directed. |
| 113 | M&L for chequered cement concrete tiles of 30cmx30cmx25mm thick set and jointed and pointed in neat cement slurry as in treads and cut polished with gray cement and no pigment, complete all as specified and directed. |
| 114 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed. |
| 115 | M&L for cement concrete type C2 (1:3:6) (using 40 mm graded crushed stoneaggregate) as in surface channel and drains, complete all as specified and directed. |
| 116 | Extra for forming fair finished drain or channels 30cm inner girth in cement concrete using extra cement including forms, mould, mitred/stopped ends etc, complete all as specified and directed. |
| 117 | M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation and mass concrete, complete all as specified and directed. |
| 118 | M&L for raised pointing to random rubble uncoursed or brought upto courses in cement mortar1:4, complete all as specified and directed. |
| 119 | Site clearance in soft and loose soil, complete all as specified and directed. |
| 120 | Excavation in trenches for foundation etc not exc 1.5m wide and not exc 1.5 m in depth in any type of soil, complete all as specified and directed. |
| 121 | Returning filling in including spreading levlling ,watering and well ramming in layers nexc 25cm thick, complete all as specified and directed. |
| 122 | Removal ofexcavated material to a distance nexc 50 m and depositing at a level nexc 1.5 m above the starting point, complete all as specified and directed. |
| 123 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; verticle or to batter, complete all as specified and as directed. |
| 124 | M & L for RCC design Mix M-25Using 20 mm greaded Stone AggregateinFoundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed. |
| 125 | Formwork to sides of pillars, posts, struts, piers,columns, and stanchions,complete all as specified and as directed. |
| 126 | M & L for RCC designMix M-25 (using 20 mm greaded Stone Aggregate)in Columns, pillars, piers, posts and struts, complete all as specified and as directed. |
| 127 | M & L for RCC designMix M-25 (using 20 mm greaded Stone Aggregate)in beams, cantilvers, bressummers, lintels over, complete all as specified and as directed. |
| 128 | Formwork to soffits of suspended slabs such as roof slab, floor slabs, landings and similar works not exceeding 200mm thick, complete all as specified and as directed. |
| 129 | M & L for RCC designMix M-25(sing 20 mm greaded Stone Aggregate)slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slab and in shelves and teh like, complete all as specified and as directed. |
| 130 | M&L for old sizehalf brick work with sub class \"B\" bricks straight or curved on plan to any radius built in cement mortar 1:4, complete all as specified and directed. |
| 131 | M&L for 40 mm thick for damp proof course to horizontal surfacesincementconcrete 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate including necessary form work, complete all as specified and directed. |
| 132 | M&L for 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:3 and finished even and fair for receiving tiles on vetical surface, complete all as specified and directed. |
| 133 | M&L for glazed coloured ceramic tiles in dado/vertical surface (350mm x250mm x 7 mm/450x300x7mm thick set and jointed in neat cement slurry and pointed in colouredcement to match the surface, complete all as specified and directed. |
| 134 | M&L for Rendering 15 mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement, complete all as specified and directed. |
| 135 | S&F factory made pressed steel frame box type window/Ventilatorwith side huge shutters incl pintol hinges,steel handles, steel peg stay and all locking arrangement and onecoat of red oxide primer complete all specified.Note : (i)The window shall be fabricated as per Drg NoCEBTZ/TD/888R & 889.(ii)MS fillets, glazing, wire gauge shall be measured and paid separately. |
| 136 | S&F for 150mm size aluminium anodised barrel tower bolt of extruded section and fixed, complete all as specified and directed. |
| 137 | S&F in repair 75 mm bore PVC (SWR) bend any radius with oval acess, complete all as specified and directed. |
| 138 | S&F for PVC (SWR) junction double, (double T), equal or unequal 110mm bore, complete all as specified and directed. |
| 139 | S&F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed, complete all as specified and directed. |
| 140 | S&F 32 mm size CP waste coupling(half or full threaded) Minimum weight 32mm-45gms/40mm-60 gms) incl waste pipe, complete all as specified and directed. |
| 141 | S&F vitreous china wash down closet pan (Pedestal pattern) whiteincl PVC valveless syphonic action type flushing cisten low level white with inlet ,ball valve , float and handle including brackets, complete all as specified and directed. |
| 142 | S&F half stall urinal flat back (large) including spreader 635x395x420 white colour and urinal pipe, complete all as specified and directed. |
| 143 | M&L for preparing newly plastered surfaces of ceilings and applying three coats of white wash, complete all as specified and directed. |
| 144 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and directed. |
| 145 | M&L for 25 mm thick Sand filling under floors or in foundationincluding watering and consolidation for laying interlocking tiles, complete all as specified and directed. |
| 146 | M&L for Machine pressed precast cement concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, set and joint filled with sand, complete all as specified and directed. |
| 147 | M&L for Cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) for protecting interlocking tiles rounded or chamfered on edges, complete all as specified and directed. |
| 148 | Construction ofOn site RCC Hume Pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 10 users, complete all as sdpecified and as directed. |
| 149 | Construction of Soakage wells exc, in ordinary Soil, Foundation in PCC 1:3:6, walls of Honey combed and solid in M-25 cement concrete, including intercepting chamber, screen chamber Brick work in CM (1:4), RCC cover slab in M-25/ RR masonry / Filling with brick bats, complete of size 1.8 M dia X 3.0M deep, complete all as specified and directed. |
| 150 | M&L for PCC 1:3:6 type C2 as in bed to drain pipes incl packing under and haunching against the sides of pipes after they are laid and tested for Salt Glazed Stoneware pipe 150mm dia, complete all as sdpecified and as directed. |
| 151 | M&L for providing precast ce- ment concrete 1:2:4 type B1 (using 20mm graded aggregatesin landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces . and setting in mortar complete with joints to match , set in cement mortar 1:4, complete all as specified and diredted. |
| 152 | M&L for brick work with sub class \"B\" bricks straight or curved on plan built in CM 1:4, complete all as specified and diredted. |
| 153 | M&L for RCC pipes, class NP 2, 150mm bore, laid and jointed in trenches with collars,complete all as specified and directed. |
| 154 | Demolition of Reinforced cement Concrete of any description and in any position not otherwise specifically provided for(reinforcement cut as required to facilitate demolition),complete all as sdpecified and directed. |
| 155 | M&L stone walling random rubble, uncoursed, well bonded bedded and solidly hearted, built in cement mortar 1:6 but except stone, complete all as specified and directed. |
| 156 | M&L for precast PCC bond stone type C-1 (1:3:6) (using 20mm graded stone aggregate) for stone masonary set in CM (1:6), coomplete all as specified and directed. |
| 157 | S &F for factory made precast concrete Box type Culvert of size 2m x 2m and thickness of concrete walls 200mmas per ASTMC-1483 with double wall reinforcement using 12mm dia TMT bars @ 200mm c/c spacing to Fe-500, as per IRC-6/2017 and IRC 112/2020 using M-40 design mix with minimum water cement ratio 0.45 (using 20mm graded crushed stone aggregate) and using intact form work. Minimum cover to reinforcement shall be 50mm, complete all as specified and directed.Note: The cost of item includes all T&P required at site for placing the concrete structure and transport of structure to site as required. |
| 158 | M&L for RCC M-25 design mix (using 20mm gradded stone aggregate) as in walls, retaining wall, basement,ballast wall and like any thickness, complete all as specified and directed. |
| 159 | Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar worksincluding attached pillasters, buttresses etc. verticle or to batter, complete all as specified and directed. |
| 160 | M&L for mild steel work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes framed guard bars barred iron doors, ladders; framed balusters walk ways, railings, frameworkand similar work con- forming to e.290 Gde-E-165, complete all as specified and directed. |
| 161 | M&L for cement concrete type B-2, 1:2:4 (40 mm graded stone aggregate) 75 mm thick as in floors/ paving laid in alternate pannels finished even and smooth without using extra cement, complete all as specified and directed. Note:- No extra cost shall be claimed by contractor for use of vibrator. |
| 162 | M & L for Stone/boulder pitching and grouted with cement and sand mortar 1:6, complete all as specified and directed. |
| 163 | Sch \"A\" Part-II (E/M works)Taking down carefully copper/ aluminum point wiring (light, fan, bell, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc.) removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc. to match with existing specifications keeping aside serviceable items for reuse within the same building and removing unserviceable items from site, complete all as specified and directed. |
| 164 | M&L for point wiring for following types of electrical points with two runs of FRLS PVC insulated unsheathed 1100 Volts, grade multi stranded copper conductor of size 1.5 sqmm drawn through medium grade PVC conduit pipe not less than20mm dia concealed in wall/ surface in ceiling incluidng provn of pressed steel terminal boxes suitable size of 2.8mm thickplastic laminated sheet cover for mounting switches, sockets, fan regualrors etc with necessary screws and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making goodthe diturbed surfaces to match with the existing, complete all as specified and directed as per following:-Note: Cost of cutting chasing and making good to disturbed surface to match with existing surface are deemed to be included in quoted rate. |
| 165 | One light point/ fan point controlled by one switch. |
| 166 | One socket out let 5 Amp point controlled by one switch one way on same switch board. |
| 167 | One socket out let 5 Amps point controlled by one switch one way on independent board. |
| 168 | All as per item No 164 here-in-before, but point wiring 2.5 sqmm for socket outlet 15Amps point controlled by one switch. |
| 169 | M&L for switch piano flush type 5 Amps SP one way 230 volts, complete all as specified and directed. |
| 170 | M&L for switch piano flush botton single pole, one way 15 Amps 240 volts, complete all as specified and directed. |
| 171 | M&L for socket outlet 5 Amps, 5 Pin, flush type, 230 volts, complete all as specified and directed. |
| 172 | M&L for socket outlet 15 Amps, 6 Pin, flush type, 230 volts, complete all as specified and directed. |
| 173 | M&L for ceiling rose surface bakelite 3 terminals, PVC/ Polycarbonate, isolated body, complete all as specified and directed. |
| 174 | S&F in replacement of stepped type elctronic fan regulator heavy duty flush type, complete all as specified and directed. |
| 175 | M&L in replacementfor LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in andincluding LED tube light connection complete prewiredand connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height, complete all as specified and directed. |
| 176 | S&F in replacement lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/ angular/ pendent fittings, complete all as specified and directed. |
| 177 | S&F in replacement of bulk head luminaries with 1 x 9/10 watt bulk head luminaries LED light driver holder etc complete with all accessories and including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 178 | S&F LED lamp 7/9/10 watt suitable for lamp holder, complete all as specified and directed. |
| 179 | Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and including painting of ceiling fans complete, in situ with synthetic enamel paid by spraying including filling cavities with filler, one coat after cleaning all dust etc and reinstalled at existing position, complete all as specified and directed. |
| 180 | S&F in replacement of sheet metal enclosure MCB DB, SPN 240 volts 8 way with IP-43 IK-09 protection double door 200A complete with appropirate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specificaiton, complete all as specified and directed.Note: MCBs will be measured separately. |
| 181 | S&F sheet metal enclosure MCB DB, SPN 240 volts 4 way with IP-43 IK-09 protection double door 200A complete with appropirate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specificaiton, complete all as specified and directed.Note: MCBs will be measured separately. |
| 182 | S&F in replacement of MCB SP 240 volt any rating from 6 to 40 Amps conforming to IS 8828 of 1996, with rupting capacity 10KA including providing thimble for out goint cable complete all as specified and directed. |
| 183 | S&F in repair/ replacement of MCB SPN 240 volt any rating from 5 to 40 Amps conforming to IS 8828 of 1996, with rupting capacity 10KA including providing thimble for out goint cable complete all as specified and directed. |
| 184 | S&F exhaust fan heavy duty plastic body 250mm sweep with all accessories connecting up with twin core tweisted flexible coper conductor cable from ceiling rose to exhaust fan including necessary fixing arrangement for proer fixing in wall, complete all as specified and directed. |
| 185 | Supply and fixing storage type Water Heaters, BEE 5 star rated ( Geysers) of cap 25 Ltrs electric driven 230 volts , 50 HZ AC supply complete with outer metallic body and Copper inner tank including fixing on wall by grouting of suiatble nut bolts etccomplete all as specified and directed. |
| 186 | Supply, laying, jointing and testing,XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushioning, brick protection cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE). |
| 187 | M&L for service cable of size 10Sqmm 2 core 1100volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular, complete all as specified and directed. |
| 188 | M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed.Note: Punned thickness of sand shall be measured and paid. |
| 189 | Supply and Laying brick covering with width equal to length of brick as mechanical protection to cable using Sub class ‘B’ bricks laid dry flatsize 230mm x 115mm x 75mm, complete all as specified and directed. |
| 190 | M&L for earthing complete with GI earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground earth pit to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, connected to the connecting to the GI wire 4.0mm dia by means of belts, nuts, check nut and washer of GI and steel wire protected by GI pipe 15mm bore light grade for protection to the extend of 7.5mtr as earthing wire with provn charcol and salt complete all as per electric plate NO 3 of SSR Part-1 including PCC type C-1 chamber with RCC cover watering arrangement with GI Pipe 20mm dia medium grade and MS funnel including excavation and earth work and returneing filling in including ramming and removal of surplus soils and testing on compleiton including taking down of old unserviceable earthing, complete all as specified and directed.(Note:-Earth wire and protection pipe upto board is included in the rate quoted) |
| 191 | S&F in replacement 15watt LED recess/ surface mounting 3000K/6000k light fitting LED backlit round or square (as required at site) down lighter with high efficient LEDs and glate free opal diffuser IP20, internally prewired, 230V, complete with all accessories such as electronic driver, connector block etc and necessary fixing arrangement at any height and removing old unserviceable item with all connected accessories, complete all as specified and directed. |
| 192 | Supply and laying 20mm bore GI steel water tubing, medium grade ISI marked, laid in trenches with and including all fittings such as bends, elbows, tees, short pieces, union etc, complete all as specified and directed. |
| 193 | M&L for cutting existing GI pipes 40/50mm dia for alterrations above or below ground level and including all fittings etc, complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail