Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCHEDULE \"A\" PART-I to SCHEDULE \"A\" PART-XIII:Note: Schedule \"A\" Part-I to Part-XIII are prepriced by MES.Bidders shall insert their lump sum amount in green coloured field under Column 6 only. |
| 2 | Lump Sum price worked out by the contractor for \"Buildings & Structures\",as listed in Schedule \"A\" Part-I. |
| 3 | Lump Sum price worked out by the contractor for \"Site Clearance/Area Development/Earth Work/Excavation\",as listed in Schedule \"A\" Part-II. |
| 4 | Lump Sum price worked out by the contractor for \"Pile Foundation\", as listed in Schedule \"A\" Part-III. |
| 5 | Lump Sum price worked out by the contractor for \"Internal Water Supply\", as listed in Schedule \"A\" Part-IV. |
| 6 | Lump Sum price worked out by the contractor for \"Internal Electrification\", as listed in Schedule \"A\" Part-V. |
| 7 | Lump Sum price worked out by the contractor for \"External Water Supply\", as listed in Schedule \"A\" Part-VI. |
| 8 | Lump Sum price worked out by the contractor for \"External Electrification\", as listed in Schedule \"A\" Part-VII. |
| 9 | Lump Sum price worked out by the contractor for \"Area Drainage\",as listed in Schedule \"A\" Part-VIII. |
| 10 | Lump Sum price worked out by the contractor for \"Sewage Disposal\",as listed in Schedule \"A\" Part-IX. |
| 11 | Lump Sum price worked out by the contractor for \"Road/Path/Culvert\", as listed in Schedule \"A\" Part-X. |
| 12 | Lump Sum price worked out by the contractor for \"Lightening Protection\", as listed in Schedule \"A\" Part-XI. |
| 13 | Lump Sum price worked out by the contractor for \"Fire Fighting\", as listed in Schedule \"A\" Part-XII. |
| 14 | Lump Sum price worked out by the contractor for \"Arboriculture\", as listed in Schedule \"A\" Part-XIII. |
| 15 | SCHEDULE \"A\" PART-XIV: (MISCELLANEOUS ITEMS): |
| 16 | PILE FOUNDATION: |
| 17 | Boring for bored cast-in-situ piles 500mm dia. in any type of soil/clay/ soft rock except hard rock/fractured rock using DMC (Direct Mud Circulation) method of boring and getting out and disposal of spoil out side MD land complete all as specified and as shown on drawings and as directed by the Engineer-in-Charge. |
| 18 | Boring for 500mm dia. bored cast in situ piles in hard rock and getting out and disposal of spoil out side MD land using DMC method (Direct Mud Circulation) complete all as specified and shown on drawings and as directed by the Engineer-in-Charge. |
| 19 | M&L for MS pipe liner fabricated out of 6mm thick plain MS plate confirming to Fe-410 S by welding the joints, strengthening wherever required, providing stiffners, lifting hooks including all T&P required, shifting the same from position to positions required, driving in truevertical alignment in position to the required level for piles complete, all as specified anddirected.Note: MS Pipe liner shall be casted as mentioned in drawing.How ever for payment purpose, the depth of pile liner shall be measured up to cut off level only irrespective of the depth provide for retaining concrete/ bentonite slurry.The unit rate/lumsum price quoted shall be deemed to include for the above aspect. |
| 20 | Chipping of laitance concrete in piles above cut of level up to a maximum of 1m from cut of level and disposal to distance of exc. 1.5 Km but n. exc. 5 Km and depositing where directed complete all as specified and as directed. |
| 21 | Carrying out initial compressive load test on 500mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed. |
| 22 | Carrying out initial lateral load test on 500mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed. |
| 23 | Carrying out routine compressive load test on 500mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed. |
| 24 | Carrying out routine lateral load test on 500mm dia. pile as specified in IS, complete all as specified and as directed. |
| 25 | Carrying out pull out test on cast in situ pile 500mm dia. as per IS complete all as specified and as directed by the Engineer-in-Charge. |
| 26 | Carrying out low strain integrity test on cast in situ piles 500mm dia. including analysing the result as per ASTM D 5882 complete all as specified and as directed by the Engineer-in-Charge.Note fot Item Nos.18 to 23: Test results shall be approved by the CWE.The GE shall intimate CWE before commencing the load test and the test shall be carried out in presence of the authorised representative detailed by the CWE. |
| 27 | INTERNAL WATER SUPPLY: |
| 28 | S&F angular cock 15mm dia., fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure pipes complete all as specified and as directed by the Engineer-in-Charge. |
| 29 | INTERNAL ELECTRIFICATION: |
| 30 | Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly, for One light/bellpoint controlled by one no. one way switch or One fan (ceiling fan/exhaust fan/wall mounted) point controlled by one switch or one 3 pin socket outlet 5 Amps on independent board complete all as specified and as directed by the Engineer-in-Charge. |
| 31 | All as per item No.25 here-in-before but for One light point controlled by two nos. two way switches on independent board. |
| 32 | All as per item No.25 here-in-before but for one 3 pin socket outlet 5 Amps on same board. |
| 33 | All as per item No.25 here-in-before but for one 3 pin socket outlet 5 Amps on independent board with 2.5 Sq.mm. FRLS PVC wire and one run of 2.5 Sq.mm. copper cable for earth continuity. |
| 34 | All as per item No.25 here-in-before but for one 3 pin socket outlet 15 Amps on independent board with 4 Sq.mm. FRLS PVC wire and one run of 4 Sq.mm. copper cable for earth continuity. |
| 35 | M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 4 Sq.mm. cable and one run of 4 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed by the Engineer-in-Charge. |
| 36 | M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 6 Sq.mm. cable and one run of 6 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed by the Engineer-in-Charge.Note for Item Nos.30 & 31: Two runs of cable, one run of earth wire and one run of conduit will be measured as one unit. |
| 37 | S&F LED adore lamp 9 Watts, 240 Volts AC, B22 type, CDS 5 star complete all as specified and as directed by the Engineer-in-Charge. |
| 38 | S&F energy efficient LED tube light fitting (Mirror optic) with tube 5 Watt, 240 Volts, 50 Hz, luminous efficiency 100 Lumen per Watt, CRI>80, PF>0.9, surface mounted, decorative ultra slim square profile LED lighting fixture etc. with extruded polycarbonate environmental friendly, energy efficient ready to use pack complete with mounting bracket etc. including connecting up with 1.0 Sq.mm. 3 core flexible copper conductor cable complete all as specified and as directed by the Engineer-in-Charge. |
| 39 | S&F energy efficient LED tube light fitting with tube 9 Watts, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 Sq.mm. 3 core flexible copper conductor cable complete all as specified and as directed by the Engineer-in-Charge. |
| 40 | S&F ceiling fan complete with blades, down rods, and accessories, 230 Volts, 1200mm sweep, minimum air delivery 210 CFM with service value 6.0 BEE five star rated with brushless direct current motor (BLDC) with and including flexible copper wire 1 Sq.mm. form ceiling rose to connector of ceiling fan complete all as specified and as directed complete all as specified and as directed by the Engineer-in-Charge. |
| 41 | S&F exhaust fan made out of sturdy engineering plastic complete with louvers shutter, 230 Volt, 50 Hz, 1200 RPM copper winding of sweep 250mm, fixed on wall including making opening, fixing and making good the distrubed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through 1 Sq.mm. twin core flexible wire complete all as specified and as directed by the Engineer-in-Charge. |
| 42 | M&L earthing complete with GI plate electrode 60cmxx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metresdeep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI wire 4mm dia. by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete all as specified and as directed by the Engineer-in-Charge.Notes:1.Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in soft/loose soil with PCC type C1 in bed and pit complete all as specified and as directed.2.Earth lead up to 7.50m length is deemed to be included in the quoted rate the beyond 7.5m length will be measured and paid separately. |
| 43 | M&L for 4mm dia galvanised iron or steel wire earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed. |
| 44 | EXTERNAL WATER SUPPLY: |
| 45 | M&L brick masonry valve chamber of size 750x750x750mm (Inner dimensions) comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200mm thick PCC 1:4:8 type D2 foundation, brick work in CM 1:6, plastring internal surface 15mm tick in CM 1:4, PCC 1:3:6 type C1 couping, 50x50x6mm angle iron, 3mm thick MS plate cover complete with locking arrangement painting to steel and iron surface with two coat of synthetic enamel paint over one coat of zinc chrome primer complete all as shown on drawing and as specified and as directed by the Engineer-in-Charge. |
| 46 | M&L for cutting existing steel tubing 80mm dia. for alterations or additions necessarily done in position with out taking down and inserting GI \"TEE\" of size 80x80x50mm for tapping ccomplete all as specified and as directed by the Engineer-in-Charge. |
| 47 | EXTERNAL ELECTRIFICATION: |
| 48 | LT FPB made out of CRCA sheet 3.00mm thick outdoor pedestal type CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switch gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material including as per IS-8623 tinned aluminum bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 Volts 500 Amps capacity complete with powder coating, necessary internal electric connection as required and provision of the following:Incoming:(a) MCCB 4 Pole, 415 V, 36 KA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 320 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes-01 No.Outgoing:(a) MCCB 4 Pole, 415 V,25 kA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 63 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes-05 Nos. (01 No. for each floor, 01 No. for booster & 01 No. spare)(b) MCCB 4 Pole, 415 V,16 kA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 25 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes-02 Nos. (01 No. for food lift & 01 No. spare)(c) MCB TPN, ‘C’ Curve, 20 A ISI marked 50 Hz 220 V grade-02 Nos, (01 No. for street light panel & 01 No. spare)(d) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers(e) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers |
| 49 | S&F street light control panel 415 Volts 3 phase and Neutral with MCCB of suitable capacity Amp rating Contactor fitted inside steel enclosure including timer, PCC work(for Garden, Pathway & Street light) all as specified and as directed by the Engineer-in-Charge. |
| 50 | S&F LED street light fitting 70/75 Watt 230 Volts AC, outdoor type with high pressure die cast aluminium housing and heat resistant complete with impact and corrosion resistant including thermal management in multiple opticals complete all as specified and as directed by the Engineer-in-Charge. |
| 51 | S&F LED garden light (Bollard) 9 Watt, 230 Volts, AC, outdoor type luminaire with diffuser at the upper portion with IP 66 protection complete all as specified and as directed by the Engineer-in-Charge. |
| 52 | S&F LED pathway light, 15 Watt, 230 Volts, AC, outdoor type luminaire with diffuser at the upper portion with IP 66 protection complete all as specified and as directed by the Engineer-in-Charge. |
| 53 | S&F fountain spot light luminaire 9 Watt 12 Volts with RGB lighting colour complete all as specified and as directed by the Engineer-in-Charge. |
| 54 | Supply, fixing, installing, testing and commissioning ofFountain Water Pump with 1/4 crown nozzle, 5m ring and with 10m pipe complete all as specified and as directed by the Engineer-in-Charge. |
| 55 | S&F Loop in loop out box of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, combi-climate cable glands of IP 66/IP 67 for cable entry and grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 KA, ‘C’ Curve overload and short circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, etc. complete all as specified and directed. |
| 56 | Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes complete all as specified and as directed by the Engineer-in-Charge; |
| 57 | 3½ core 70 Sq.mm. |
| 58 | 3½ core 35 Sq.mm. |
| 59 | 4 core 16 Sq.mm. |
| 60 | 2 core 10 Sq.mm. |
| 61 | M&L earthing complete with GI plate electrode 60cmxx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metresdeep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth strip 32x6mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete all as specified and as directed by the Engineer-in-Charge.Notes:1.Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in any type of soil with PCC type C1 in bed and pit complete all as specified and as directed.2.Earth lead up to 7.50m length is deemed to be included in the quoted rate the beyond 7.5m length will be measured and paid separately. |
| 62 | M&L earthing complete with GI plate electrode 60cmxx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metresdeep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI wire 4mm dia. by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete all as specified and as directed by the Engineer-in-Charge.Notes:1.Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in soft/loose soil with PCC type C1 in bed and pit complete all as specified and as directed.2.Earth lead up to 7.50m length is deemed to be included in the quoted rate the beyond 7.5m length will be measured and paid separately. |
| 63 | M&L earth continuity conductor or main earthing lead made of galvanised iron strip 32x6mm size, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI pipe for earthing etc. complete all as specified and as directed by the Engineer-in-Charge. |
| 64 | Boring of holes under road, pavement, hard standing etc. by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe 150mm dia. suitable for 0.4 mpa working pressure complete all as specified and as directed by the Engineer-in-Charge. |
| 65 | AREA DRAINAGE: |
| 66 | M&L for pre-cast SFRC 560mmx560mm EHD-35 Extra Heavy Duty (Square) manhole cover slabs conforming to IS 12592-2002, set in cement mortar (1:4) complete all as specified and as directed by the Engineer-in-Charge. |
| 67 | SEWAGE DISPOSAL: |
| 68 | M&L for pre-cast SFRC 560mmx560mm EHD-35 Extra Heavy Duty (Square) manhole cover slabs conforming to IS 12592-2002, set in cement mortar (1:4) complete all as specified and as directed by the Engineer-in-Charge. |
| 69 | ROAD/PATH/CULVERT: |
| 70 | M&L granular sub base (GSB) with grading V of 200mm thick compacted thickness (Laid in two layers of 100mm each, compacted seperately) confirming to grading as specified, spread, rolled & consolidated to required gradient and camber complete using necessary mechanical paver/grader & vibratory soil compacter of capacity 8-10 Ton complete all as specified and as directed by the Engineer-in-Charge.Notes:1. Pavement shall be made for solid quantity arrived after consolidation. 2. Compaction of granular sub base filling shall be carried out under optimum moisture condition to achieve 98.50% modified density.3. Curing shall be carried out as per IRC recommendations.4. Before execution of this item the approved material obtained from outside MD land shall be tested/Checked for suitability to use.5. Contractor shall use vibratory earth compactor in lieu of power roller to achieve 98.50% MDD at OMC without any extra cost and the method of compaction to be adopted as per recommendation of agency reporting MDD at OMC.6. GSB shall be as per MORTH specification as detailed in particular specification. |
| 71 | M&L pre-cast cement concrete block masonry with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed by the Engineer-in-Charge. |
| 72 | LIGHTNING PROTECTION: |
| 73 | S&F single pointed air terminal aluminium rod 12mm dia. 300mm long with aluminium box plate of size of 125x125x10mm fixed over porcelain insulator and fixed on roof top complete including 40mm dia. medium grade MS pipe 300mm long and including necessary fasteners fixed for lighting protection with necessary connections to earthing etc. complete all as specified and as directed by the Engineer-in-Charge. |
| 74 | S&F horizontal roof conductor and down conductor of size 25x3.15mm aluminium strip fixed to walls/columns/projections/roof including porcelain blocks/DMC insulator spaced at 1m interval complete all as specified and as directed by the Engineer-in-Charge. |
| 75 | S&F test point terminal block made out of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia. 25mm long hexagonal head screws etc. complete all as specified and as directed by the Engineer-in-Charge. |
| 76 | M&L earthing complete with GI plate electrode 60cmxx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metresdeep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth strip 32x6mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete all as specified and as directed by the Engineer-in-Charge.Notes:1.Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in any type of soil with PCC type C1 in bed and pit complete all as specified and as directed.2.Earth lead up to 7.50m length is deemed to be included in the quoted rate the beyond 7.5m length will be measured and paid separately. |
| 77 | S&F galvanised iron strip of 32x6mm size with saddles and fixing screws etc. for wall conductors connected with equipment and above ground(Proper insulation should be provided between the strip and walls) complete all as specified andas directed by the Engineer-in-Charge. |
| 78 | TV & TELEPHONE SOCKETS: |
| 79 | S&F rigid non metallic PVC conduit of 25mm dia. (external) concealed in wall, exclusive of junction box but inclussive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers lock nuts, saddles, pipe hooks etc. including GI wire for wiring of TV/telephone cable complete all as spcified and as directed by the Engineer-in-Charge. |
| 80 | S&F telephone/communication network sockets (Jack type) RJ 11-1 with shutter 1 module with cover plate complete with all acessories complete all as specified and as directed by the Engineer-in-Charge. |
| 81 | S&F TV co-axial socket 1 module complete all as specified and as directed by the Engineer-in-Charge. |
| 82 | S&F factory fabricated GI metal flush boxes suitable for 1-2 module complete all as specified and as directed by the Engineer-in-Charge. |
| 83 | COOLING APPLIANCES: |
| 84 | S&F water cooler electric driven (single phase) having approx storage capacity of 120 Litres and nominal cooling capacity of 60 Litre per hour complete all as specified and as directed by the Engineer-in-Charge. |
| 85 | S&F S&F voltage stabiliser for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ±2.5% and of capacity 1 KVA complete all as specified and as directed by the Engineer-in-Charge. |
| 86 | AIR CONDITIONING: |
| 87 | S&F 1.5 TR hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 capacity including bracket, copper tube etc. as per OEM specification complete all as specified and as directed by the Engineer-in-Charge. |
| 88 | S&F 2.0 TR hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 capacity including bracket, copper tube etc. as per OEM specification complete all as specified and as directed by the Engineer-in-Charge.Note for Item Nos.69 & 70: Extra length of copper tubing as per site requirement is deemed to be included in the rate quoted. |
| 89 | S&F S&F voltage stabiliser for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ±2.5% and of capacity 4 KVA complete all as specified and as directed by the Engineer-in-Charge. |
| 90 | S&F S&F voltage stabiliser for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ±2.5% and of capacity 5 KVA complete all as specified and as directed by the Engineer-in-Charge. |
| 91 | FIRE FIGHTING SYSTEM: |
| 92 | S&F MS flanged pipe 150mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and directed by the Engineer-in-Charge. |
| 93 | S&F MS flanged pipe 100mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and directed by the Engineer-in-Charge. |
| 94 | S&F MS flanged pipe 80mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and directed by the Engineer-in-Charge. |
| 95 | S&F MS flanged pipe 63mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and directed by the Engineer-in-Charge. |
| 96 | S&F MS flanged pipe 40mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and directed by the Engineer-in-Charge. |
| 97 | S&F MS flanged pipe 25mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and directed by the Engineer-in-Charge. |
| 98 | S&F air cushioning tank (Air vessel) 300mm dia. and 1000mm high with dished top, made of minimum 6mm thick MS pipe /plate complete with 20mm dia. Brass air valve (ball type), 20mm dia. stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accessories complete fixed on top of suitable flange hydrant line complete all as specified and as directed by the Engineer-in-Charge. |
| 99 | S&F LED EXIT light double sided with battery backup up to 2 hours complete all as specified and as directed by the Engineer-in-Charge. |
| 100 | Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade, of sixe 4 core 10 Sq.mm. complete all as specified and as directed by the Engineer-in-Charge. |
| 101 | M&L earthing complete with GI plate electrode 60cmxx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metresdeep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth strip 32x6mm size by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete all as specified and as directed by the Engineer-in-Charge.Notes:1.Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in soft/loose soil with PCC type C1 in bed and pit complete all as specified and as directed.2.Earth lead up to 7.50m length is deemed to be included in the quoted rate the beyond 7.5m length will be measured and paid separately. |
| 102 | M&L earth continuity conductor or main earthing lead made of galvanised iron strip 32x6mm size, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI pipe for earthing etc. complete all as specified and as directed by the Engineer-in-Charge. |
| 103 | Supply and install fire extinguisher ABC Type light weight squeeze grip type confirming to IS: 15683 of capacity 6.0 Kg complete all as specified and as directed by the Engineer-in-Charge.Notes:1. Fire extinguisher should equipped with hose of appropriate size and open-close should be with the help of wheel type valve.2. Fixing arrangement to wall will be included in the quoted rates.3. Appropriate size of sign board should be hanged from wall/roof near the all fire pints. |
| 104 | ELECTRIC CHIMNEY: |
| 105 | Supply, fixing, testing and commissioning of Electric Chimney for kitchen, stainless steel sheet auto clean filter less, easy oil collection, heat auto clean with LED lamps, motion sensor control with digital display 60 cm, 1200 m3/hr airflow along with chimney installation kit, 3 meters length 15 cm dia. with expandable aluminium duct pipe up to 3.04 meters, 15 cm cowl cover, 2 U-shaped clamps and 2 meter adhesive aluminium tape complete all as specified and as directed by the Engineer-in-Charge. |
| 106 | S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as spcified and as directed by the Engineer-in-Charge. |
| 107 | ICE MAKING MACHINE: |
| 108 | S&F ice making machine of capacity 60 Ltrs., self standing, made out of stainless steel body, air cooled with eco friendly refrigerant R-404 a, working on single phase power supply 29 Kg/24 hrs. rated capacity and 9 Kg ice storage bin complete all as specified and as directed by the Engineer-in-Charge. |
| 109 | ARBORICULTURE: |
| 110 | Supply and planting of the Draught Tolerant plants (Height of plant above ground level will be as specified by Engineer-in-Charge) including filling the plantation pit of size 60x60x60cm with sweet soil i.e. approved mixture of fertiliser soil and manure (vermicompost+cow dung) all as specified in the relevant PS clause, using pesticides of approved quality, including construction basin around the plant with excavated soil for stagnation of water and mixing the manure from time to time as required etc. complete all as specified and as directed by the Engineer-in-Charge. |
| 111 | Supply and planting of the Ashoka plant (Height of plant not less than 2.00m above ground level) including filling the plantation pit of size 60x60x60cm with sweet soil i.e. approved mixture of fertiliser soil and manure (vermicompost+cow dung) all as specified in the relevant PS clause, using pesticides of approved quality, including construction basin around the plant with excavated soil for stagnation of water and mixing the manure from time to time as required etc. complete all as specified and as directed by the Engineer-in-Charge. |
| 112 | Supply and planting of the Royal Palm tree (Height of plant not less than 2.00m above ground level) including filling the plantation pit of size 60x60x60cm with sweet soil i.e. approved mixture of fertiliser soil and manure (vermicompost+cow dung) all as specified in the relevant PS clause, using pesticides of approved quality, including construction basin around the plant with excavated soil for stagnation of water and mixing the manure from time to time as required etc. complete all as specified and as directed by the Engineer-in-Charge. |
| 113 | Supply and planting of Jamun tree (Height of plant not less than 1.50m above ground level) including filling the plantation pit of size 60x60x60cm with sweet soil i.e. approved mixture of fertiliser soil and manure (vermicompost+cow dung) all as specified in the relevant PS clause, using pesticides of approved quality, including construction basin around the plant with excavated soil for stagnation of water and mixing the manure from time to time as required etc. complete all as specified and as directed by the Engineer-in-Charge. |
| 114 | Supply & Planting Carpet Grass by piece turfing including preparation of ground and filling up to 10 cm deep with sweet soil i.e. approved mixture of fertiliser soil and manure (vermicompost+cow dung) all as specified in the relevant PS clause,and pesticides, watering etc. complete all as directed by the Engineer-in-Carge.Notes for Item Nos.88 to 92:1. Supply only fertiliser soil, vermicompost and cow dung etc. will be measured and paid for separately under Sch \"A\" item Nos.93 to 95 below respectively.2.Earthwork excavation and removal of surplus soil will be measured and paid for separately under the relevant items of Sch \"A\" Part-II. |
| 115 | Supply only approved good quality fertiliser soil suitable for carpet grass all as specified. |
| 116 | Supply only approved vermicompost of the best quality all as specified. |
| 117 | Supply only approved farm yard manure (cow dung) best quality suitable for arboriculture all as specified. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail