| 1 | Sch \"A\" Part-I (B/R Works)Demolition of reinforced cement concrete to any thickness as in slabs beams, columns up to development length of reinforcement in columns incl cutting of reinforcement as reqd at site, complete all as specified and directed. |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below of above GL) and removing out side MD land on contractors own arrangement, complete all as specified and directed. Note: Demolition includes any no of layers including overleaped tiles , stone etc during executionand no extra cost shall be borne by govt exchequer. |
| 3 | Demolition of Brick/stonework built in cement mortar of any descrption incl all necessary quions arches piilars etc, complete all as specified and directed. |
| 4 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water, complete all as specified and directed. |
| 5 | Demolition of reinforced cement concrete in roof, floor (other than ground floors)beams staircase, landing chajja and similar work, complete all as specified and directed. |
| 6 | Form work to sides and soffits of roof beams incl supports over hangs etc finished rough, complete all as specified and directed. |
| 7 | Form work to edges of concrete flats, breaks ,conc railing nexc 200mmwide finished rough, complete all as specified and directed. |
| 8 | Form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick surface horizontal or sloping, surface of concrete, complete all as specified and directed. |
| 9 | M&L for RCC M-25 design mix using 20 mm graded crushed stone aggregate as in beams , cantilevers over span 1.5m landings , balconies etc, complete all as specified and directed. |
| 10 | M&L for reinforced cement conc M-25 design using 20 mm graded crushed stone aggregatemix as in slab supported on walls , beam, and columns in floors,roofs landings , balconies etc, complete all as specified and directed. |
| 11 | M&L for TMT bars10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed. |
| 12 | All as per Item No 11.00 here-in-before but 6mm to 8 mm diareinforcement as in stirrups, rings, spacers. |
| 13 | M&L for TMT bars 5 mmto 10 mm diain reinforcement as in stirrups, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed. |
| 14 | M&L for providing cement concrete in steps, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-1, complete all as specified and directed. |
| 15 | M&L for brick work with sub class \"B\" bricks exc 6m mean radius straight or curved on plan built in cement mortar1:4, complete all as specified and directed. |
| 16 | All as per Item No 15.00 here-in-before but except bricks. |
| 17 | S&F in repair Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed. |
| 18 | S & F3 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane, complete, after hacking out old brocken glass, complete all as specified and directed. |
| 19 | S & F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed. |
| 20 | M&L for rendering 15 mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth with using extra cement including mixing integral water proofing compound in the proportion as mentioned in manufacturer\"s instructions, complete all as specified and directed.Note: Water proofing compound to be measured and paid separately. |
| 21 | M&L for 15mm thick rendering on brick or concrete surfaces in CM 1:6 finished even andsmoothw/o using extra cement, complete all as specified and directed. |
| 22 | M&L for rendering 5mm thick on brick or concrete surface as in ceiling , sides of beams in cement mortar 1:3 finished even and smooth without using extra cement, complete all as specified and directed. |
| 23 | Roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc, complete all as specified and directed. |
| 24 | M&L for Cement concrete type B-2, 1:2:4 (40 mm graded aggregate) 75 mm thick as in Floorslaid in alternate pannels finished even and smooth without using extra cement, complete all as specified and directed.Note- No extra cost shall be claimed by contractor for use of vibrator. |
| 25 | M&L for roughening surface of old concrete column/ beam bydemolisingspalling concreate till old reinforcement is visible picking, sweeping clean and washing down with water to remove dust, etc and applying the rust remover to remove the rust from existing reinforcement on old existing reinforcement, complete all as specified and directed. (Product : Sikka rustoff 100/, pidilite 8832 Gm Rust remover or equivalent).Note : Mode of measurement is as girth of Column /Beam. |
| 26 | M&L for providing and fixing rebar of reqd length and diameters with Sikka Anchor fixing 3/ Mungo/Fischer FIS V 390/ Hilti Re 500 Epoxy resin wherever reqd in RCC members incl power drilling cleaning of holes , then rebars should be inserted in holes that should be filled with epoxy to ensure the bond as per site requirement (of size 16mmx160mm), complete all as specified and directed. |
| 27 | All as per Item No 26.00 here-in-before but size 20 mm x 200 mm. |
| 28 | All as per Item No 26.00 here-in-before but size 10mm x 100 mm. |
| 29 | M&L for high strength single layer of polymer modified cementious high strength(>=50Mpa) repair mortar minimum 20 mm thickness or as per site requirement, complete all as specified and directed. Make: Dr Fixit/ Sikka or equivalent. |
| 30 | Supply and apply a shrinkage free flow low viscous epoxy resin based injection grout (Product Sikkadur 52 or equivalent), complete all as specified and directed. |
| 31 | M&L for water tight form work incl bolting strutting propping etc incl removal of form work from column beam etc, complete all as specified and directed. |
| 32 | Supply and applying non shrink cement micro concrete ready to use non shrink cementitious free flow micro concrete, complete all as specified and directed. Make : Sika Rep Microcrete-4 or equivalent Yield :Approx 17 Ltr per bag (30 Kg) as per product description. Concrete shall have Compressive strength shall have 60 N/mm2 after 28 days as per ASTMC 1107-99 . (Note : Concreting shall have to be carried under supervision of agencey approved) |
| 33 | M&L for providing 75 mm thick cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in plinth protection finished even and fair without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight, complete all as specified and directed. |
| 34 | M&L for water proofing treatment on non approachable / non accessible roof surface horizontal and vertical surfaces in following sequence through manufacturer / authorized applicator of the manufacturer complete all as specified and directed :-(i)10mm thick plastering on roof surfaces in cement mortar 1:4 mixed with water proofing compound as per manufacturers instructions.(iii) After drying plastered surfaces, apply a coat of bituminous primer @0.40 Kg/Sqm on the prepared surface of roof surfaces. (iv)After the primed surface has dried, apply a coat of hot blown bitumen85/25 or equivalent viscosity grade @ 1.2 Kg /Sqm of the surfaces etc complete.(v) Laying unrolled over the bitumen coated surfaces polymeric water proofing membrane, of approved make standard weight not less than 3 Kg / sqm with 100 mm over laps shall be sealed by flame as per manufacturer instruction.(vi) Applying a coat of hot air blown grade bitumen of grade 85 / 25 @ 0.5 Kg / sqm duly sanded over polymeric membrane complete. |
| 35 | Taking down and re-fixing in same opening after repair of steel shutter ofany description and any size, complete all as specified and directed . |
| 36 | M&L for preparation of newly plastered surfaces of any surface/wall and applyingtwo coats of exteriorweather proof paint over a coat ofalkaliresistant primer, complete all as specified and directed. |
| 37 | M&L for applying three coats of white washing on wallsincluding preparation of newly plastered surfaces, complete all as specified and directed. |
| 38 | M&L for applying two coats of white washing on ceilingincluding preparation of new/old plastered surfaces, complete all as specified and directed. |
| 39 | M&L for preparation of old painted steel surfaceincluding old roof sheet of any descriptionexc 10 cm width or grithand applying one coat of of synthetic enamel paint, complete all as specified and directed. |
| 40 | M&L for two coats of cement cement base paint on walls including preparation on newly plastered surfaces, complete all as specified and directed. |
| 41 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 42 | M&L for 100mm thick PCC (1:4:8) type D-2 (using 40mm gradded crushed stone aggregate) as in sub base of floor, complete all as specified and directed. |
| 43 | M&L for 25 mm thick Sand filling under floors or in foundationincluding watering and consolidation for laying interlocking tiles, complete all as specified and directed. |
| 44 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade, set and joint filled with sand, complete all as specified and directed. |
| 45 | M&L for cement concrete (1:2:4) type B-1 using20mm stone aggregate as in coping, roof padding benching kerbs / side of interlocking tiles , rounded or chamfered on edges including form work, complete all as specified and directed. |
| 46 | M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggr) as in surface channels and drains incl all necessary form work, complete all as specified and directed. |
| 47 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in CM, using extra cement incl forms, moulds mitred/stopped end etc, complete all as specified and directed. |
| 48 | Excavation in post holes (or similar holes) each n exc 0.5 Cum getting out, returning filling in and ramming earth or broken rubble mixed with earh around in layer n exc 25cm watering & removing surplus soil to a distance n exc 50m & making good surface in any type of soil, complete all as specified and directed.Note : No Extra cost to be borne by govt exchequer for PCC if any encountered during excavation) |
| 49 | Excavation in trenches in soft/loose soil n.exc 1.5 m wideand n.exc 1.5 m in depth for foundation, pier holes etc n exc 10 sqm on plan and getting out, complete all as specified and directed. |
| 50 | Returning filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm deep in soil, complete all as specified and directed. |
| 51 | Removing excavated soil to a distance exc 250 mtr but not exc 500 mtr and depositing where directed at a level of n.exc 1.5 m above the starting point, complete all as specified and directed. |
| 52 | M&L for cutting holes in brick walls built in cementmortar or cementlime mortar inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1, complete all as specified and directed. |
| 53 | All as per Item No 52.00 here-in-before but in stone walls built in cement mortar or in cement lime mortar. |
| 54 | M&L for providing cement concrete type B-2 1:2:4 (40 mm graded stone aggregate) in foundation ,filling and mass concrete as in posts, complete all as specified and directed. |
| 55 | S&F rolled section as in main and cross beams , hip and jack rafters , purlins ,Vertical post where connected to common rafters and running rails and guides for sliding gates , doors fixed with angle cleats or other connecting plates, complete all as specified and directed. |
| 56 | S&F Mild steel screw bolts with hexagonal or square heads at one end and screwed the other , or screwed both ends , each screwed end to be fitted with washers and one hexagonal or square nut nexc 5cm long dia of shank11to 15mm, complete all as specified and directed. |
| 57 | S&F Mild steel holding nut, bolts with hexagonal or square heads at one end and screwed the other , or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square exc 22.5cm and n exc 30mm long dia of shank16 to 20mm, complete all as specified and directed. |
| 58 | S&F (plain orchequered ) channels ,square cutor notched ( oridinary and counter sunk) forming holes, w/o any attatchment, complete all as specified and directed. |
| 59 | S&F pre-painted galvalume zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall , fixed with self tapping screws//\"L\" or \"J\" hooks, complete all as specified and directed. |
| 60 | M&L for Providing & fixing of 4mm thick designer ceiling board (Make : Everest/Ramco/) in ceiling fixed with screw as per manufactures instructions, laid on hot dipped galvanized iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick galvanized steel sheet & of size 24x32x300mm and spaced at 12mm centres securelyfixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4mm dia to be fixed by approved rowlplug, leveladjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall flush fitting of 1200 long cross tee with (double stitching) to be inter locked between main runners at 600mm centre to from 1200x600mm modules cross tee longer than 600mm modules to be formed by fitting 600mm long cross tee, tee perimeter wall angle shall be of 0.45mm thick galvanized steel of size 19x19mm and 300mm long of white colour all as per instruction, complete all as specified & directed. |
| 61 | S&F steel wirefebric , cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, complete all as specified and directed. |
| 62 | Supply only mild steel work in MS flat for securing Welded wire meshwith post and filxed with nuts/boltsand similar items conforming to Fe 410-(Gde-E-250) quality, complete all as specified and directed. |
| 63 | M&L for 25mm thick PCC type B-0 using 20mm graded crushed stone aggregate as in sub base for laying floor finishes, complete all as specified and directed. |
| 64 | M & L for machine cut kota stone in slab flooring18-20 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of slab including grinding, rubbing ,polishing to mirror finish over and including 15mm thick screed bed in CM (1:4), complete all as specified and directed. |
| 65 | All as per Item No 64.00 here-in-before but as in riser to steps, skirting ,dado,window cills fixed with 15mm thick cement mortar 1:4. |
| 66 | S&F glazed coloured ceramic tiles on vertical surface 300x450x7mm thick, jointfree,set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick plaster of CM (1:4), complete all asspecified and directed. |
| 67 | M&L for framed work as in doors and gates of angle or other section including stringers,ms plates, braces etc complete drilled for fixing of steel sheeting or other coverings to doors etc conforming FE-410-Grade 250, complete all as specified and directed. |
| 68 | S&FStainless Steel wire cloth 0.36 mm nominal dia of wire and 0.91 mm average width of aperture fixed with tinned tacks or galvanised wire staple, complete all as specified and directed. |
| 69 | Supply and fix anodised aluminium frame for door windows , ventilators with one or more rebates including jointing cleat for fixing etc, complete all as specified and directed. |
| 70 | Supply and fixing aluminium anodised door shutters, aluminium section weighting 0.55 kg/m including necessary joining cleats , glazing clips , rubber , neoprane packing handles 2 Nos in each door , hinges , anodised aluminium snap beading screws etc, complete all as specified and directed. |
| 71 | M&L for sheet glass, ordinary quality, 5.5 mm thick fixed to aluminium doors with aluminium and rubber beading in square exc 0.5 sqm in each pane, complete all as specified and directed. |
| 72 | S&F 5mm thick plain colour PVC sheet in strips & channel feathered at the edges for fixing as in pannels to door and Solid PVC Partitions inclusive of Solvent Cement and fixing at site, complete all as specified and directed. |
| 73 | S&F for brass mortice lock vertical type 100 mm long with 4 lever, complete all as specified and directed. |
| 74 | M&L in 75mm diaoutlet of inPVC SWR foor trap plain with grating including jointing with solvent cement including removing old trap and make good existing floors etc, complete all as specified and directed. |
| 75 | S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid under floors or in trenches, complete all as specified and directed. |
| 76 | M&L for preparation of steel surface and applying two coats of synthetic enamel paint over a coat of red oxide primerexc 10 cm width or girth, complete all as specified and directed. |
| 77 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and directed. |
| 78 | M&L for 75mm thick PCC (1:4:8) type D-2 (using 40mm gradded crushed stone aggregate) as in sub base of floor, complete all as specified and directed. |
| 79 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, set and joint filled with sand, complete all as specified and directed. |
| 80 | Removing excavated material n.exc 50mm and depositing where directed at a level n. exc. 1.5m above the starting point, complete all as specified and directed. |
| 81 | M&L for PCC.1:3:6 type C2 (40mm graded stone aggregate) as in foundation mass concrete, complete all as specified and directed. |
| 82 | M&L for reinforced concretre pipes, class NP 2 150mm bore, laid and jointed complete with collars, complete all as specified and directed. |
| 83 | Supply only integral water proofing compound conforming to IS, complete all as specifiedand directed. |
| 84 | M&L for precast ce- ment concrete 1:2:4 type B1 (using 20mm graded stone aggregates)in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces . and setting in mortar complete with joints to match, set in cement mortar 1:4, complete all as specified and diredted. |
| 85 | M&L for chequered cement concrete tiles of size 300x300x25mm thick set and jointed in neat cement slurry in path over and including 15mm thick screed bed in CM 1:6, complete all as specifiedand directed. |
| 86 | Sch \"A\" Part-II (E/M works)Taking down unserviceable aluminium point wiring (light, fan, bell, socket or power) complete, including all fitting and fixtures such as switches, ceiling roses, pendants, regulators sockets, light fittings etc.) removing material for taking credit (credit for above items should be made as per conditions separately) and making good the disturbed, complete all as specified and directed. |
| 87 | M&L for point wiring for following types of electriccal points with two runs of FRLS PVC insulated unsheathed 1100 Volts, grade multi stranded copper conductor of size 1.5 sqmm drawn through medium grade PVC conduit pipe not less than20mm dia concealed in wall/ surface in ceiling incluidng provn of pressed steel terminal boxes suitable size of 2.8mm thickplastic laminated sheet cover for mounting switches, sockets, fan regualrors etc with necessary screws and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making goodthe diturbed surfaces to match with the existing, complete all as specified and directed as per following:-Note: Cost of cutting chasing and making good to disturbed surface to match with existing surface are deemed to be included in quoted rate. |
| 88 | One light point/ fan point controlled by one switch. |
| 89 | One socket outlet 5 Amp point controlled by one switch one way on same switch board. |
| 90 | One socket out let 5 Amps point controlled by one switch one way on independent board. |
| 91 | All as per item No 87 here-in-before, but point wiring 2.5 sqmm for socket outlet 15Amps point controlled by one switch. |
| 92 | S&F switch piano flush type 5/6 Amps SP one way 230 volts, complete all as specified and directed. |
| 93 | S&F switch piano flush botton single pole, one way 15 Amps 240 volts, complete all as specified and directed. |
| 94 | S&F socket outlet 2 in 1,5/15 Amps, 3/5 Pin, flush type, 230 volts, complete all as specified and directed. |
| 95 | M&L for socket outlet 2 in 1, 5/15 Amps, 3/6 Pin, flush type, 230 volts, complete all as specified and directed. |
| 96 | M&L for ceiling rose surface bakelite 3 terminals, PVC/ Polycarbonate, isolated body, complete all as specified and directed. |
| 97 | M&L in replacementfor LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in andincluding LED tube light connection complete prewiredand connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height, complete all as specified and directed. |
| 98 | S&F lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/ angular/ pendent fittings, complete all as specified and directed. |
| 99 | S&F LED lamp 7/9 watt suitable for lamp holder, complete all as specified and directed. |
| 100 | S&F in replacement of sheet metal enclosure MCB DB, SPN 240 volts 8 way with IP-43 IK-09 protection double door 200A complete with appropirate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specificaiton, complete all as specified and directed.Note: MCBs will be measured separately. |
| 101 | S&F in replacement of sheet metal enclosure MCB DB, SPN 240 volts 4 way with IP-43 IK-09 protection double door 200A complete with appropirate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specificaiton, complete all as specified and directed.Note: MCBs will be measured separately. |
| 102 | S&F in replacement of MCB SP 240 volt any rating from 6 to 40 Amps conorming to IS 8828 of 1996, with rupting capacity 10KA including providing thimble for out goint cable complete all as specified and directed. |
| 103 | S&F in replacement of MCB SPN 240 volt any rating from 5 to 40 Amps conorming to IS 8828 of 1996, with rupting capacity 10KA including providing thimble for out goint cable complete all as specified and directed. |
| 104 | S&F in replacement LED building security light 35 Watt with pressure dia-cast housing with individual LEDs as light source and lens embedded PC cover having TOP opening separate driver compartment with IP 66 protection and impact resistance of IK 07, complete with connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 1.00 sqmm, complete all as specified and directed. |
| 105 | S&F in replacement of bulk head luminaries with 1 x 9/10 watt bulk head luminaries LED light driver holder etc complete with all accessories and including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 106 | S&F exhaust fan heavy duty plastic body 250mm sweep with all accessories connecting up with twin core tweisted flexible coper conductor cable from ceiling rose to exhaust fan including necessary fixing arrangement for proer fixing in wall, complete all as specified and directed. |
| 107 | Supply, laying, jointing and testing,XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushioning, brick protection cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE). |
| 108 | M&L for service cable of size 10Sqmm 2 core 1100volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular, complete all as specified and directed. |
| 109 | M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed.Note: Punned thickness of sand shall be measured and paid. |
| 110 | Supply and Laying brick covering with width equal to length of brick as mechanical protection to cable using Sub class ‘B’ bricks laid dry flatsize 230mm x 115mm x 75mm, complete all as specified and directed. |
| 111 | Supply and Laying in GI tubing light grade of 50mm with necessary fittingsas in cable protection in trenches/ fixed on wall / floor including necessary clamps bolts and nuts, complete all as specified and directed. |
| 112 | M&L for earthing complete with steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground earth pit to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, connected to the connecting to the GI wire 4.0mm dia by means of belts, nuts, check nut and washer of GI and steel wire protected by provision of GI pipe 15mm bore light grade including provision of concrete pit made from RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 02 Nos and with 6mm MS bar handle made to shape, GI medium grade 20mm bore pipe ofr watering perforated at bottom 1.75mtr long placed on top edge of earth plate, common salt & charcoal filling, test point made out of 17mm x 8mm FI with fixing arrangement, funnel, wire mesh and earth work in hard/ dense soil, returning filling in including ramming and removal of surplus soil to a disance not exc 50mtr, all as per electrical plate No 5 of SSR Part-I, connected to earth test point including testing on completion, complete all as specified and directed. |