| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. DSR 2023 SI. No. 2.6.1 |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) Complete al as per DSR 4.1.10 |
| 3 | Brick work with common burrnt clay. F.P.S. (Non Modular) bricks 1:6 Cement & C/Sand mix mortar in Fdn and Plinth all respect Complete all as per DSR 6.1.2 |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth ,in proportion 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) DSR No 5.1.2 (Reinforced Cement Concrete) |
| 5 | R/F cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement . as per DSR NO. 5.2.2 |
| 6 | Brick work with common burrnt clay. F.P.S. (Non Modular) bricks 1:6 Cement & C/Sand mix mortar in super structure all respect Complete all as per DSR 6.4.2 |
| 7 | Steel reinforcement for R.C.C work including straihtening, cutting, bending, placing in position and binding all complete as per DSR NO. 5.22A.6 |
| 8 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer.Complete al Complete all as per DSR10.2 |
| 9 | Painting or varnishing work in small areas or new wood work with one coat (upto one square metre of ready mixed priming paint and one coat of approved Complete all as per DSR13.53 |
| 10 | 12 mm thick cement plaster of mix 1:6 ( 1 cement & 6 coarse sand Complete all as per DSR .No 13.4.2 |
| 11 | 12 mm thick cement plaster of mix 1:6 ( 1 cement & 6 coarse sand Complete all as per DSR .No 13.4.2 |
| 12 | 12 mm thick cement plaster of mix 1:6 ( 1 cement & 6 coarse sand Complete all as per DSR .No 13.4.2 |
| 13 | Providing and applying white cement based putty of average thickness brand and manufacture over the plastered wall surface to prepare the surface even and smooth complete all as per DSR 13.80 |
| 14 | Distmpring two coat with oi; bound distemper of approved brands & manufacturer Complete all as per DSR 13.41.1 |
| 15 | Finising walls with Acrylic Smooth exterior paint of required shade New work (two or more coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) Complete all as per DSR 13.46.1 |
| 16 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. DSR 2023 SI. No. 2.25(a) |
| 17 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete all as per DSR 2.27 |
| 18 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).DSR 11.47.2 Size of Tile 600x600 mm |
| 19 | 1:2:4 (1 cement : 2 Coarse sand (zone-iii) derived from netural sources stone aggregate 20 mm nominal size derived form natural sources ) complete All as per DSR 4.2.3 |
| 20 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface I recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. As per DSR E&M Ser No1.1.2 Group B |
| 21 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch. connections etc. as required. As per DSR E&M Ser No 1.32 |
| 22 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq.mm + 1 X 2.5 sqmm earth wire As per DSR E&M Ser No 1.14.2 |
| 23 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. As per DSR E&M Ser No 1.25 |
| 24 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providingand fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, paintingetc. as required.As per DSR E&M Ser No 1.57 |
| 25 | Supply and fixing of 12-15 Watt LED Down lighter (SMD Type) (System lumen efficacy >135 lm/Watt) Supplying, installation, testing &Commissioning of LED Recessed/surface Down lighter (Round /squre/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement. Powder coated dia cast /Extruded aluminium Body including trim. complete all as per DSR E&M 8.3.3 |
| 26 | Supply and fixing of Bruh Less Direct Current (BLDC) mortar supply, Installation, Testing and Commissioning of celling fan with Brush Less Direct Current (BLDC) mortar, class of insulation: B, 3 nos.metal (Aluminum alloy) blades, 30 cm long down rod 2 nos. cogylator nopies, . complete all as per DSR E&M 9.2.2 |
| 27 | S/F Information /sign board i/c all comp. at site. |
| 28 | ADD GST 18 % Please Enable Macros to View BoQ information |