| 1 | Excavation in foundation in ordinary soil (Loam, clay or sand) including lift upto 1.50 M. and lead upto 30 M.. Complete al as per DSR 2.8.1 |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :CC 1:4:8 with Stone Aggregate Complete all as specified 4.1.8 |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)Complete all as per DSR 6.1.1 |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 inSuper Structure in: Cement mortar 1:4 (1 cement : 4 coarse sand)Complete all as per DSR 6.4.1 |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering in proportion 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) DSR No 5.2.2 (Reinforced Cement Concrete) |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for :For Column beam and Slab as per DSR 5.9.5 |
| 7 | M.s. or tor steel in plain such as RCC work i/c its cutting, bending & binding complete . Complete all as per DSR 5.22.6 |
| 8 | 12mm thick plaster in 1:4 Cement & C/Sand mix mortar Complete all as per DSR 6.4.2 |
| 9 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer.Complete al Complete all as per DSR10.2 |
| 10 | Supply and fixing of Kota Stone in floor complete all in 20mm thick Complete all as per DSR 11.26.1 |
| 11 | Providing Wall putty on New Surface with approved quality of material of Berger/JK/Birla or Similar make in Two coats.Complete all as per DSR 13.8 |
| 12 | Distempring two coat with oil bound distemper of approved brands & manufacturer complete Complete all as per DSR 13.41.1 |
| 13 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)Complete all as per DSR13.46.1 |
| 14 | Painting or varnishing work in small areas or new wood work with one coat (upto one square metre of ready mixed priming paint and one coat of approved Complete all as per DSR13.53 |
| 15 | Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) Complete all as per DSR 22.14.1 |
| 16 | 6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge.As per DSR 13.86 |
| 17 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface I recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. As per DSR E&M Ser No1.10.2 Group B |
| 18 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq.mm + 1 X 2.5 sqmm earth wire As per DSR E&M Ser No 1.14.2 |
| 19 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. As per DSR E&M Ser No 1.25 |
| 20 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. As per DSR E&M Ser No 1.31 |
| 21 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch. connections etc. as required. As per DSR E&M Ser No 1.32 |
| 22 | S/F Information /sign board i/c all comp. |
| 23 | ADD GST 18 % Please Enable Macros to View BoQ information |