Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M&L for sand filling under floor or in foundations including watering and consolidation complete all as specified and directed. Note:- Punned thickness of sand shall be measured and paid. |
| 2 | M&L for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 3 | M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 4 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 5 | M&L forproviding precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings kneelers, apex stones, pier caps, columns, posts, boundary pillars,bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling) corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in cement mortar 1:6 complete with joints to match complete all as specified and directed. |
| 6 | M&L for drilling suitable holes in reinforced cement concrete with power driven drill machine to a minimum depth of 10D (D-dia of bar in mm) inRCC beams, lintels, columns and slabs to introduce new steel barsincluding cleaning the holes by air blowers prior to fixing the new steel bars in position using Lokfix E77, a two-component epoxy anchoring material, supplied in 3:1 ratio having compressive strength (EN196) not less than 122 N/sqmm, Flexural Strength (EN196) not less than 66 N/sqmm, E Modulus (EN ISO 527-2) 6300 N/sqmm or of equivalent make but excluding the cost of reinforcement, complete all as per direction of Engineer-in- Charge for 10mm dia shear connectors. Note : 1. Anchoring chemical shall comply with ETA 21/0354, ETA 21/0518 for anchoring bars for 10mm dia complete all as specified and directed.2. Reinforcement shall be measured and paid separately. |
| 7 | M&L for chipping of plaster / unsound weak and cracked concrete / cover of reinforcement of RCC member like slab, beam, column, chhaja etc or as per site requirement by standard power driven percussion type or pneumatic chisel including tapering all edges, making square shoulder of cavities etc and disposal of debris / malwa from site complete all as specified and directed. |
| 8 | M&L for cleaning of existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, dirt etc. complete and applying two coats of alkline rust converting primer on the existing rebar and allowing it to react with rust for 6 hours and form corrosion resistant, insoluable and adherant protective layer, including cleaning the reinforcement wire brushing to remove the rust spalls, with time interval of 1 hour between the coats complete all as specified and directed. |
| 9 | M&L for corrosion inhibiting impregnation coating, designed for use as an imregnation for protection of steel reinforcement within unexposed concrete with in consumption of 0.5 Kg/Sqm. The product should be amino alcohol and inorganic combination based migratroy corrosion inhibitor for both cathodic and anodic protection complete all as specified and directed.Make : Fosroc / Thermax / Sika or equivalent as approved by GE. |
| 10 | M&L for zinc rich epoxy anti-corrosive protective coating for rebar corrosion protection system complete all as specified and directed.Make : Fosroc / Thermax / Sika or equivalent as approved by GE. |
| 11 | M&L for providing, mixing & applying two component of epoxy resin concrete bonding coat on prepared RCC surfaces as per manufacturer specification including prepartion of surface by chipping and throughly cleaning of surface complete wherever required complete all as specified and directed. Make : Fosroc / Thermax / Sika or equivalent as approved by GE. |
| 12 | M&L for re-building the section of damaged RCC elements to its original size on an average 15 mm thickness in two layers each by providing and applying with pre- batched, polymer modified mortar of approved make having compressive strength not less than 50 N/sqmm (28 days) as per ASTM C-109 and flexural strength not less than 05 N/sqmm (7 days) as per ASTM C-293-79 standards including water fog curing to keep surface moist for seven days complete all as specified and directed. Make : Fosroc / Thermax / Sika / Dr. fixed or equivalent make as approved by GE.Note : (i) To achieve the required thickness, the above process should be repeated after 24 hours.(ii) Surface area with 15mm thick layer will be measured as one unit for payment purpose.(iii) Rate shall be including all necessary scaffolding upto height of four storey building. |
| 13 | M&L for brick work using old size bricks with sub class \"B\" bricks straightor curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 14 | M&L Brick work using old size bricks with sub class \"B\" bricks straightor curved on plan to any radius in half brick thick walls built in cement mortar 1:6 complete all as specified and directed. |
| 15 | M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms or any horizontal portion and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granitecomplete all as specified & directed. |
| 16 | M&L 20 mm thick granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) (or any vertical portion) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified & directed. |
| 17 | Taking down chowkats or frames n.exc 1.5 Sqm each with shutters (without taking off shutters from the frames) and removing to or from store complete all as specified and directed. |
| 18 | Taking down chowkats or frames exc 1.5 sqm but not exc 4.0 sqm each with shutters (without taking off shutters from the frames) and removing to or from store complete all as specified and directed. |
| 19 | S&F for solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, supplied and fixing in opening as specified and shown on drawing made on section 8 of SSR 2020 Part-II complete all as specified anddirected. |
| 20 | S&F Factory made Solid PVC Moulded door shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2 mm thick moulded Prelam PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 21 | Taking down old aluminium door of any size and refixing in the same opening including change of hinges, neoprene rubber bead, replacing the damage portion of chowkhat or frame and tightening all loose screws and frames of the door complete all as specified and directed. |
| 22 | S&F aluminium, anodised, barrel tower bolts of extruded section 200 mm long complete all as specified and directed. |
| 23 | S&F aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy of 300 mm length of bolt complete all as specified and directed. |
| 24 | S&F butt hinges, medium weight, cold rolled mild steel 100 mm long complete all as specified and directed. |
| 25 | S&F extruded aluminium alloy handles fabricated type anodised of 150 mm size complete all as specified and directed. |
| 26 | S&F in repair mortice lock, vertical type, size 100 mm, 4- lever mild steel body with two keys complete all as specified and directed. |
| 27 | S&F in repair brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges etc complete as all specified and directed. |
| 28 | S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass,other parts made of mild steel heavy duty and fixed complete all as specified and directed. |
| 29 | S&F 25 mm dia stainless steel, silver & chrome finish, fancy type, anti-rust curtain rod complete as all specified and directed. |
| 30 | S&F brass curtain rod bracket / end bracket for holding drapery rod of 25mm dia complete as all specified and directed. |
| 31 | M&L for mild steel TMT bar 10 mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 32 | S&F rolled mild steel section in framed work as in doors or gates of angle or other section withgusset plates, rails, braces etc, complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging of grade Fe 410-W (Gde E-250) quality A complete all as specified and directed. |
| 33 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 34 | M&L for powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 35 | S&F for powder coated (thickness of powder coating not less than 50 micron) anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. Note : Glass and other filling material in panels shall be measured and paid seperately. |
| 36 | S&F powder coated (thickness of powder coating not less than 50 micron) anodised aluminium window and ventilator shutters, side hung / sliding type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws anodised aluminium fittings such as peg stays 150 mm long (1 No), hinges type B-21, 100 mm long (2 No) , suitable handle (1 No) complete all as specified and directed. |
| 37 | M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 38 | S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) door shutter with frame, partly glazed with 5 mm thick tinted glass and partly panelled with 9 mm thick prelaminated particle board with both side decorative laminated including rubber bead joining cleat for fixing in position, aluminium door handle 150 mm size, aluminium barrel tower bolt 200 mm size,floor door stopper of size 200mm etc. using medium weight, aluminium section as follow :- (a) Frame (top & side) section shall of size 101.60x 44.75 x 2.4 mm (Section 14021)(b) Vertical Members of shutter section shall be of size 85.00 x 44.45 x 2.00 mm (Section No 19560).(c) Top members of shutter section shall be of size 83.50 x 44.45 x 2.00 mm (19581).(d) Lock rail (Middle member) of shutter section shall be of size 150 x 44.4 x 3.00 mm (Section No 19596)(e) Bottom Members of shutter section shall be of size 150.00 x 44.45 x 3.10 mm (Section No 19584)Note:- Section given above are of Make Jindal, the contractor may use similar section ofother make as mentioned in Appx \"B\" of PS. |
| 39 | M&L for applying fibre reinforced, single component, elastomeric liquid applied water proofing coating in white colour, anti-fungal, anti-algae, resistance to water and ageing, excellent UV resistant having Solar Reflective Index more than 105, with PU hybrid polymers and reinforcing acrylic fibers, elongation greater than 300% and applied in three layer complete all as follow :- (a) Preparation of surface by cleaning and removing loose particles then apply first coat of liquid water proofing after diluting as per manufacture instruction as a primer and allow the surface to dry for minimum 10 to12 hours complete all as specified and directed. (b) Apply second coat of liquid water proofing without dilution on the primed surface and allow time to dry the surface for minimum 10 to12 hours complete all as specified and directed.(c) Apply third coatof liquid water proofing without dilution over the second coat and allow minimum 48 hour complete all as specified and directed.Note : (i) Work shall be carried out by authorised applicator of manufacturer onlyand contractor will submit MoU with authorised applicator of manufacturer before execution of work. (ii) Material incorported in the work shall be calculated as per site requirement and full quantity of material shall be brought at site before execution of work.(iii) Necessary gurantee for 05 years shall be submitted by the contractor. Make :- Berger-HS Roof Kool & Seal, STP-Shali Urethane (R) BTD Plus, Asian - Smart care Damp Proof Ultraor equivalent make as approved by GE. |
| 40 | S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 41 | S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 42 | M&L for carried out water roof treatment as under :-(a) Demolition of existing water proofing treatment including PCC in roof covering / padding kerbs, roof kerbs, benching, coved fillets, old decayed water proofing treatment of any type upto mother slab of roof. (b) All visible cracks to be opened up in V shape cleaned properly with wire brush washed and filled with cracks filling compound for cracks upto 5mm width / depth of cracks. (c) Cracks of more than 5mm width / depth are filled with URP cement grouting by injecting through nozzles till refusal by authorised applicator of manufacturer, carefully by following manufacture instruction. The size and spacing of nozzles shall be as per manufacturer instruction or as directed by Engineer-in-Charge.(d)Preparation of dry surface and laying 25mm thick PCC type B-0, (1:2:4) using 12.5mm graded stone aggregate finished even & smooth without using extra cement to cover negative slope into prop with including WPC @ 3% weight of cement or as per manufactururer instruction.(e) M&L for rendering 10mm thick in CM 1:3 on concrete surfacesto receive water proofing treatment finished even and smooth complete all as specified.(f) Necessary gurantee for 5 years shall be submitted by the contractor.Make :- Cement Grout : Dr. Fixit (Fixit Pidicrete URP Model:301) or equivalent in Fosroc / Choksey chemicals / Sika / Berger (HS Super Grout) or equivalent as approved. |
| 43 | M&L false ceiling at all heights with semi perforated 12 mm thick micro tegular edged GRG (Glass fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 4x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, and direction of engineer-in-charge complete all as specified and directed. |
| 44 | M&L for machine cut kota stone slab flooring mirror finished 20-25 mm thick (each slab not less than 0.25 sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing andpolishing on treads of step and landing of stair including screed bed 15 mm thick in CM 1:6 complete all as specified and directed. |
| 45 | M&L for Machine cut kota stone slab mirror finished 20-25 mm thick (each slab not less than 0.25 sqm) in riser of step ,skirting, dado and pillar over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing andpolishing including rendering 15 mm thick in CM 1:4 complete all as specified and directed. |
| 46 | M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate, 75 mm thick in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed. |
| 47 | M&L for 100 mm thick Cement concrete 1:4:8type D-2using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 48 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 25 mm thick surface finished even andsmooth with using extra cement complete all as specified and directed. |
| 49 | M&L for glazed ceramic coloured tiles in vertical surface350x 250x 7 mm / 450X 350X 7 mm / 300x 600x7 mm / 450x 300x7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in CM 1:4 complete all as specified and directed. |
| 50 | M&L for non skid ceramic coloured tiles of design as approved7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 51 | M&L for non skid ceramic coloured tiles of design as approved7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 52 | M&L for full body vitrified Ceramic tiles light shade cut out of 10mm thick (square/ rectangular) polished area of each tiles not exceeding 0.36 sqm in vertical surface such as dado / skirting / risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 53 | M&L for vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished area of each tiles not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 54 | S&F for rubber moulded machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement andpigment complete all as specified and directed. |
| 55 | M&L (except interlocking paver block) for interlocking paver block, any shape and size of 60 mm thickness, by vibratory compaction, cutting paver blocks in required size and pattern, filling joints with sand including sand cushing 50 mm thick and sweep out surplus sand complete all as specified and directed.Note : (1) Old paver block obtained from dismantle shall be used. (2) Sand cushioning shall be measured and paid separetely. |
| 56 | M&L for chequered cement concrete tiles 25 cm x 25 cm x 22 to 25 mm thick set, jointed and pointed in neat cement slurry as in floors with grey cement and pigments over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 57 | Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing)and removing rubbish off the premises complete all as specified and directed. |
| 58 | M&L for rendering on fair faces of brick workor concrete surfaceof wall 15 mm thick in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed. |
| 59 | M&L for rendering on fair faces of brick workor concrete surfaceof wall 15 mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed |
| 60 | Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 61 | M&L for 15 mm thick screed bed or bedding layer in CM 1:6 surface finished fair and even for laying floor finishes complete all as specified and directed. |
| 62 | M&L for preparation of new surface of walls of any description with a coat of 1 mm thick wall putty and applying two coats of Plastic Emulsion Paint (Luxury /Royal) on wallwhite or tinted including scaffolding arrangement, trestles, ladders etc complete all as specified and directed. |
| 63 | M&L for complete removal of existing treatment and preparation of old surface of ceiling of any description and and applying two coats of Plastic Emulsion Paint (Luxury /Royal) on ceiling white or tinted including scaffolding arrangement, trestles, ladders etc complete all as specified and directed. |
| 64 | M&L for preparation of new surface of walls of any description with a coat of 1 mm thick wall putty and applying two coats of acrylic emulsion exterior grade weather proof paint over a coat of primer complete all as specified and directed.Make for Acrylic Emulsion Paint : Apex Ultima of Asian Paint / WeatherShield Max of Dulux / WeatherCoat Anti Dust of Berger or equivalent make as approved by GE.Note :- Acrylic Emulsion Paint shall be carried out as specified in clause 15.17of SSR Part-I including all necessary arrangement such as scaffolding / working plateform for execution of work upto four storey building etc. |
| 65 | M&L for complete removal of existing treatment and preparation of old surface of wall of any description with a coat of 1 mm thick wall putty and applying two coats of acrylic emulsion exterior grade weather proof paint over a coat of primer complete all as specified and directed.Make for Acrylic Emulsion Paint : Apex Ultima of Asian Paint / WeatherShield Max of Dulux / WeatherCoat Anti Dust of Berger or equivalent make as approved by GE.Note :- Acrylic Emulsion Paint shall be carried out as specified in clause 15.17of SSR Part-I including all necessary arrangement such as scaffolding / working plateform for execution of work upto four storey building etc. |
| 66 | S&F 4.8 mm thicksheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane, complete all as specified and directed. |
| 67 | M&L for complete removal of existing treatment and preparation of old surface of wall of any description, and apply two coat of plastic emulsion paint over a coat of primer and including 1 mm thick wall putty complete all as specified and directed. |
| 68 | M&L for preparationof new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 69 | S&F in repair PVC connection 15 mm size borewithPTMT nuts of length 450 mm complete all as specified and directed. |
| 70 | S&F in repair for 32 mm borebrass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and directed. |
| 71 | M&L for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors/ in wallof 150 mm bore of pipe etc complete all as specified and directed. |
| 72 | M&L in repair for table top wash basins, of size 700 x 435 x 135mm Vitreous China, white, flat back, excluding taps, waste, chain and plug andporcelainstopper but including PVC waste pipe minimum 600 mm long suitable for 32 / 40 mm dia of outlet complete all as specified and directed. |
| 73 | S&F in repair chromium plated urinal valve 15 mm dia with built in auto closing system control complete all as specified and directed. |
| 74 | S& F in repair 18mm thick granite urinal partition of size 950x450 mm,urinal partitions terminating about 40cm above floor line complete all as specified and directed. |
| 75 | S&F 16 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls / ceiling or laying in floors including special fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor etc), Unions, Ball valves, Flange and tank adaptor) complete all as specified. |
| 76 | S&F 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls / ceiling or laying in floors including special fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor etc), Unions, Ball valves, Flange and tank adaptor) complete all as specified. |
| 77 | Dismantling of AC/PVC water tank and S&Frotational moulded polyethylenewater storage tank (cylindrical vertical with closed top) 500 litre capacity hoisted and fixed in positioncomplete all as specified and directed |
| 78 | Dismantling of AC/PVC water tank and S&Frotational moulded polyethylenewater storage tank (cylindrical vertical with closed top) 1000 litre capacity hoisted and fixed in positioncomplete all as specified and directed. |
| 79 | M&L for providing circular, raised platform of height 20 cm below the tank and base dia 25 cm more than the external dia of PVC tank of 500/1000 liters using PCC 1:3:6 type C1 using 20 mm graded stone aggregate with smooth finish including necessary form work etc. complete all as specified and directed. |
| 80 | M&L for Double Wall Corrugated (DWC) pipe of class SN-4, IS-16098 (part-II) of 200mm bore (internal), laid to slope in trenches, jointed complete with coupler, bends, Tee, reducers etc and tested complete all as specified and directed.Make : Ultra plus of Supreme / Corfit of Prince / D-Rex of Astral or equivalent as approved by GE. |
| 81 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed. |
| 82 | M&L for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed. |
| 83 | M&L in repair for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed. |
| 84 | M&L in repair for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of 110 mm bore of pipe etc complete all as specified and directed. |
| 85 | S&F PVC (SWR) bends any radius of 75 mm borewithoutaccess door complete all as specified and directed. |
| 86 | S&F PVC (SWR) bends any radius of 110 mm borewithoutaccess door complete all as specified and directed. |
| 87 | S&F in repair PVC (SWR) bends any radius of 110 mm borewithoutaccess door complete all as specified and directed. |
| 88 | M&L in repair PVC (SWR) multi floor trap of diameter of outlet 75 mm, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 89 | Taking up or down steel tubing and connections including cleaning if refixingrequired for 15 mm bore of pipe complete all as specified and directed. |
| 90 | Taking up or down steel tubing and connections including cleaning if refixingrequired for 20 mm bore of pipe complete all as specified and directed. |
| 91 | S&F in repair bib taps cast copper alloy with crutch or butterfly handle, long body, screwed down, screwed for iron pipe or for brass ferrulefancy type chromium plated of 15 mm bore dia of pipe complete all as specified and directed. |
| 92 | S&F in repair for 15mm bore dia of pipe brass CP swan neck, wash hand basin mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and directed.Make : Jaquar CAT Part No OPP-CHR-15011BPM / Kohler CAT Part No 22534IN-4-CP / Grohe CAT Part No 32851000 or equivalent as approved by GE. |
| 93 | S&F in repair stop valves, fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions for 20 mm bore dia of pipe complete all as specified and directed. |
| 94 | M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 100 mm bore of pipe withcement concrete 1:3:6 type C-2 using 40mm graded stone aggregatecomplete all as specified and directed. |
| 95 | M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150 mm bore of pipe withcement concrete 1:3:6 type C-2 using 40mm graded stone aggregatecomplete all as specified and directed. |
| 96 | M&L in repair for Vitreous China urinals, bowl type flat back size of 465 x 355 x 265 mm white (minimum)with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement etc complete all as specified and directed. |
| 97 | M&L in repair toilet paper holder , of stainless steel with flat recessed type, chromium plated, fixed to walls with chromium plated (CP) brass screws complete all as specified and directed. Make:- Jaquar CAT Part No. CPA-CHR-1151 / Grohe Cat Part No. 40367000 / Kohler cat Part No. K-5633IN-CP or equivalent as approved by GE. |
| 98 | S&F in repair looking mirror 5.5 mm thick of selected quality glass of size 600 x 450 mm bevelled edge , mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screw and cup washers including aluminium anodized frame complete all as specified and directed. |
| 99 | S&F in repair white rimless single piece EWC with UF soft close slim seat cover, Hinges, fixing accessories and accessories set and cistern fittings, S trap including fixing as per manufacturer instructions complete all as specified and as directed. Make : Jaquar CAT Part No OPS-WHT-15853S300UF / CNS-WHT - 855S220SPPSM/ Kholer CAT part No. 77739T-SL-0 / Grohe Cat Part No. 39675000 / Roca CAT Part No. RS34273700H or equivalent make as approved by GE. |
| 100 | S&F in repair bib taps 2-in-1 cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrulefancy type of 15 mm bore dia of pipe complete all as specified and directed. Make : Jaquar CAT Part No KUP-CHR-35041PM / Kohler CAT Part No 25432IN-4-CP / Grohe CAT Part No 20281000 or equivalent as approved by GE. |
| 101 | S&F in repair chromium plated soap dish holder complete all as specified and directed. Make:- Jaquar CAT Part No. ACN-CHR-1131N / Grohe CAT Part No. 1024612430 / Kohler CAT Part No. K-5634IN-CP / Roca CAT Part No. RF9060A1 or equivalent as approved by GE. |
| 102 | S&F in repair angle stop valve, fancy type chromium plated cast copper alloy,for 15 mm bore dia of pipe screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed. Make:- Jaquar CAT Part No OPP-CHR-15053PM / Kholer CAT part No. 11568IN-7B-CP / Grohe CAT Part No 2201600M or equivalent as approved by GE. |
| 103 | S&F in repair health faucet (hand shower) chromium plated suitable for 15 mm dia pipe with 1.2 metre long flexible tube with non return valve and wall hook including making connections and fixed in position complete all as specified and directed.Make : Jaquar CAT Part No ALD-CHR-577 / Kholer CAT Part No K-12927IN-CP / RocaCAT Part No RF9060A1 or equivalent make as approved by GE. |
| 104 | S&F in repair for refilling ofR-410a / R-32 gas suitable for AC of any capacity, ISI marked complete all as specified and directed. |
| 105 | Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 106 | M&L for point wiring complete with 1.5 Sqmm single core (Phase - Red, Neutral - Black) PVC insulated and unsheathed multi stranded copper conductor FRLS cable of 1100 V grade PVC insulated and unsheathed cable inclosed in and including concealed PVC conduit 20mm dia medium grade with all accessories ISI marked, including MS sunken box / modular metal flushbox of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting fitting like switches, sockets fan regulators etc. including 1.5 Sqmm single core (Green colour) PVC insulated unsheathed copper earth continuity conductor FRLS cable 1100 V grade as continuous earth wire for one light / fan / bell point controlled by one, one way switch.Note :- (i) The Switch / Socket accessories shall be measure and paid separately. (ii) The cost of MS sunken box & cover plate of size as required at site and cutting chases in stone / brick masonry and making good disturbed surfaces using CM 1:3shall deemed to be included in quoted rate. |
| 107 | M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5Sqmm (Green), concealed in wall and drawninto andincluding rigid non metallic PVC conduit medium grade not less than 20 mm diaISI marked ivory colour with all conduit fittings / fixing accessories and terminated in MS sunken box modular metal flushbox of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulator as required for one 3pin socket outlet 5Amps on the same board with other switches, complete all as specified and as directed. |
| 108 | M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5Sqmm (Green), concealed in wall and drawninto andincludingrigid non metallic PVC conduit medium grade not less than 20 mm diaISI marked ivory colour with all conduit fittings / fixing accessories and terminated in MS Sunken box of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulator as required for 3 pin 5Amps socket outlet on independent board, complete all as specified and directed.Note :- (i) The Switch / Socket accessories shall be measure and paid separately. (ii) The cost of MS sunken box & cover plate of size as required at site and cutting chases in stone / brick masonary and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate. |
| 109 | M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 Sqmm (Green), concealed in wall, drawninto andincludingrigid non metallic PVC conduit medium grade not less than 25 mm diaISI marked ivory colour with all conduit fittings / fixing accessories and terminated in MS Sunken box of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulator as required for 3Pin 15 Amps socket outlet on independent board, complete all as specified and directed.Note :- (i) The Switch / Socket accessories shall be measure and paid separately. (ii) The cost of MS sunken box & cover plate of size as required at site and cutting chases in stone / brick masonary and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate. |
| 110 | M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0Sqmm (Green), concealed in wall, drawninto andincludingrigid non metallic PVC conduit medium grade not less than 25 mm diaISI marked ivory colour with all conduit fittings / fixing accessories and terminated in MS Sunken box / modular metal flushboxof thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulator as required for 3 Pin 15Amps socket outlet on independent board, complete all as specified and directed.Note :- (i) The Switch / Socket accessories shall be measure and paid separately. (ii) The cost of MS sunken box & cover plate of size as required at site and cutting chases in stone / brick masonary and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate. |
| 111 | S&F modular switch 1 way 16A, 1 module complete all as specified and directed. |
| 112 | S&F modular socket6A/16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 113 | S&F fan step regulator, 120W - 2 module complete all as specified and directed. |
| 114 | M&L in repair for sub main wiring complete with 2 runs of 6Sqmm single core PVC insulated unsheathed FRLS copper cable 1100 V grade with multistranded copper conductor ISI marked drawn through and including PVC rigid conduit / casing capping not less than 20mm and conduit accessories fixed on surface of wall / celing etc including provision of 1 Run of 6 Sqmm PVC insulated unsheathed FRLS cable with multistranded copper conductor as earth continuity complete all as specified and directed. Note : 02Run of 06 Sqmm copper wire and01 Run of 06Sqmm copper earth wire along with PVC conduct shall be measured as one unit. |
| 115 | S&F in repairamp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of Single Pole and 06 to 32 Amp current carrying capacity complete with connection testing and commissioning all as specified and directed. |
| 116 | S&F in repair sheet metal enclosure with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB of capacity 20 Amps complete all as directed. |
| 117 | M&L for servicing of split type AC of 1.5/2.0 tone capacity by taking out the same from existing location, cleaning of condenser, cooling coil, and other components with cooling coil rinse solution and clean water, greasing of fan, motor, blower etc without damage any part and re-install at the same location complete all as specified and directed. |
| 118 | M&L in repair for earthing complete withgalvanized steel earth plate 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m belownormal groundlevel, connected to GI wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of GI wire from earth electrode, supply and laying charcoaldust, common salt, PCC (1:3:6)type B-1 using 20mm graded stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4)type B-1 using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars@75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm bore GI Pipe medium grade for wateringcomplete all asshown in electrical plate No 3 of SSR Part-I(2009) and connected to earth test point including testing complete all as specified and directed. Note :- 1. PCC Chammer shall be constructed atleast 2.5 metre away form the earth electrode of the earth pit and pipe for watering shall be provided in slanting manner.2. GI wire and protection pipe upto 7.5 meter from the earth plate electrode is deemed to be included in quoted rate.3. Excavation for earthing to be done manually and Earth resistance below 3 Ohm should be obtained after measurement for every pit. |
| 119 | S&F electric water heater (Geyser), storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc. complete all as specified and directed. Note:- Connection with geyser inlet and outlet with 15mm bore GI pipe including PVC pipe is included in the quoted rate. |
| 120 | S&F in repair LED lights fitting 1x20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 121 | S&F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete all as specified and directed. |
| 122 | S&F modular switch one way6 A, 1 module complete all as specified and directed. |
| 123 | S&F modular Socket, 6A - 2/3 pin combined, 2 module complete all as specified and directed. |
| 124 | S&F white cover plate with frame, 3 module complete all as specified and directed. |
| 125 | S&F white cover plate with frame, 6 module complete all as specified and directed. |
| 126 | S&F in repair sheet metal enclosure factory fabricated for MCB distribution board SPN double door type concealed in wall 240 Volt 12 way IP-42 protection with 200 amp rated bus bar complete all as specified and directed. |
| 127 | S&F in repair sheet metal enclosure factory fabricated for MCB distribution board TPN double door type concealed in wall 415 volt 4 way IP-42 protection with 200 amp rated bus bar complete all as specified and directed. |
| 128 | S&F ceiling rose 3 phase, PVC / polycarbonate, isolated bodycomplete all as specified and directed. |
| 129 | Fixing / hanging ceiling fan any sweepand connecting up including PVC flexible three core cable with copper conductor of size 16 / 0.20 mm from ceiling rose to fan of sufficient length and connectingcomplete all as specified and directed.Note : Old fan obtain from taking down shall be refixed. |
| 130 | Taking down ceiling / exhaust fan any type, sealing cable end, dismantling blades and removing fan and blades to MES store complete all as specified and directed. |
| 131 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep with minimum air delivery 210 cubic meter per minute(CMM) with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete all as specified and directed.Note:- The rate quoted by contractor shall deemed to be included for the followings : (i) The colour BLDC Fan shall be pearl white. (ii) Proper hanging arrangement like 0.45 meter down rod, canopy etc. (iii) Writing the Fan No. on fan body.(iv) Making connection with 1.5 Sqmm copper wire complete all as directed. |
| 132 | S&F exhaust fan, made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweepof size 300mm complete all as specified and directed. |
| 133 | S&F in repairamp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN and 40 to 63 Amp current carrying capacity complete with connection testing and commissioning all as specified and directed. |
| 134 | S&F in repair415V 10KA \"B\" curve miniature circuit breaker (MCB) of TPN / FP and 40 to 100 Amp current carrying capacity complete with connection testing and commissioning all as specified and directed. |
| 135 | S&F white cover plate with frame, 12 module complete all as specified and directed. |
| 136 | M&L for PVC casing capping of size not less than 25x15 mm, ISI marked, ivory colour along with all fittings / fixing accessories, complete all as specified and directed. |
| 137 | S&F PVC blanking plate one module complete all as specified and directed. |
| 138 | Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required for 100 mm internal dia of pipe complete all as specified and directed. |
| 139 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 140 | Dismantling of stone slabs of any description or thickness, laid dry or laid dry and pointed in floor, apron etc complete all as specified and directed. |
| 141 | Demolition of cement concrete un-reinforced in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. |
| 142 | Demolition of cement concrete reinforced in ground floor and paving n exc 15 cm thick (below or above ground level) (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 143 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 144 | Dismantling of AC corrugated / semi corrugated or translucent sheet as in roof coverings complete all as specified and directed. |
| 145 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs/ blankets any thickness including cover fillets complete all as specified and directed. |
| 146 | Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortar for 200 mm internal dia of pipe complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |