| 1 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 2 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 3 | In 75x75 mm deep chase |
| 4 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 5 | 160 mm dia pipe |
| 6 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 7 | Bend 87.5° |
| 8 | 163 mm bend |
| 9 | Shoe (Plain) |
| 10 | 160 mm Shoe |
| 11 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 12 | 160 mm |
| 13 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 14 | Providing and fixing High impact Polycarbonate multiwall sheets in available shade in an existing steel frame and fixing with gasket and galvanised screws of required dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of frame work), including cutting sheets to size and shape wherever required. |
| 15 | (a) with 6mm thick multiwall polycarbonate sheets |
| 16 | Grading roof for water proofing treatment with |
| 17 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 18 | Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 19 | 12 mm cement plaster of mix : |
| 20 | 1:4 (1 cement: 4 coarse sand) |
| 21 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 22 | 1:4 (1 cement: 4 coarse sand) |
| 23 | Neat cement punning |
| 24 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 25 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 26 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 27 | Painting with aluminium paint of approved brand and manufacture to give an even shade: |
| 28 | Two or more coats on new work |
| 29 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-charge. |
| 30 | With cement mortar 1:4 (1cement: 4 coarse sand). |
| 31 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete.The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : |
| 32 | 3 mm thick |
| 33 | Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. |
| 34 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 35 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 36 | Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make. |
| 37 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge.Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). |
| 38 | 25 mm average thickness in 2 layers. |