Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Sunken Floor treatment :- Taking down old treatment/ floor tiles/ PCC and Providing & laying of water proofing treatmentto sunken portion including vertical portion by applying cement slurry mixed with acralic based polymer modified cementitious composite compound of make as approved including demolition and filling of sunken floor.(a) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @0.253 Kg/Sqm. This layer allowed to air cure for 4 Hours.(b) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.125 Kg/ Sqm this layer allowed to air cure for 4 Hours.(c). 50mm thick 1:4:8 PCC at the bottom of slab and slopeshall be 1:20 toward the corner of outer wall and GI pipe of 50mm dia (Med grade) be inserted at corner projecting outside 20 cm . (d).15 mm thick plaster in CM 1:3 mixed with WP Compound shall be provided while concrete is green.(e) Joints of trap/WC/Soil pipes shall be properly sealed with sealing compound.Cont to item No02 |
| 2 | Item No 01 ContNote :- (i). Concrete for sunken slabs shall be mixed with WP compounds asmanufacturdrs instructions before carrying out water proofing treatment the sunken slabslab shall be tested with water for 48 hrs for any leakage/dampeness is seen in ceiling below, then treatment is again carried out to RCC slab and it is again tested (Water proof compound rate will not be paid separately). |
| 3 | (ii).Only floor area shall be measured for payment purpose. |
| 4 | (iii). Treatement shall only be done from approved manufacturer & name of manufacturer required to be approved from GE before treatement. |
| 5 | Mild steel work conforming to Fe-290 (Gde E-165) as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, and similar works, complete all as specfied. |
| 6 | Demolition of brick work or stone boulder masonarybuilt in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework, complete all as specified and as directed. |
| 7 | Brick work with old size sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified. |
| 8 | Brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4, complete all as specified. |
| 9 | Taking down cement plaster of any description including racking outjoints, hacking for key, scrubbing down with water etccomplete all as specified and directed. |
| 10 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises,complete all as specified. |
| 11 | Rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished the surface even and smooth without using extra cement, complete all as specified & directed. |
| 12 | Rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified and as directed. |
| 13 | Rendering 15mm thick in cement mortar (1:6) on other than fair faces of the brick work or cement concrete surfaces, finishing the surface even and smooth without using extra cement, complete all as specified. |
| 14 | Preparation of newly plastered surfaces of walls andapplying two coats of oil bound distemper over a coat of chalk whitening primer complete all as specified and as directed. |
| 15 | Preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified. |
| 16 | Preparation of old plastered surfaces on walls and applying two coats of oil bound distemper completeall as specified and directed. |
| 17 | Preparation of old plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed. |
| 18 | Preparation of plastered surfaces or unplastered on old surfaces of walls & applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall, complete all as specified and directed.(i) The work shall be carried out in different shade and the same shall be got approved from Engineer-in-charge/GE/(ii) The work may be carried out upto 4th storey of bldgs and no extra payment shall be admissible for necessary form work & scaffolding required for the same. |
| 19 | Preparation of newly plastered surface of wall & applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall, complete all as specified and directed.(i) The work shall be carried out in different shade and the same shall be got approved from Engineer-in-charge/GE/(ii) The work may be carried out upto 4th storey of bldgs and no extra payment shall be admissible for necessary form work & scaffolding required for the same. |
| 20 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level ) complete all as specified and as directed. |
| 21 | -Ditto- all as srl item No 20 above but reinforced as in chajjas shelves, roof slab and cover slab etc. Reinforcement cut to facilitate demolition. |
| 22 | 20-25 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over with mirror cut polishing 100mm wide marble patti/border all around and including 15mm thick screed bed in cement and sand mortar 1:4 complete all as specified and as directed.Note:-(Size of Kota Stone slab shall be 53 cm x 53 cm). |
| 23 | Description all as per item No 22 above but in skirting/dado incl 10mm thick rendering CM 1:4 complete all as specified and directed. |
| 24 | Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm(400x400mm) in floors etc.set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement and sand mortar 1:4,complete all as specified and directed. |
| 25 | Glazed ceramic coloured tiles (450 x 350mm x 7mm thick, as in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15mm thick back coat layer plaster in cement mortar 1:4, complete all as specified and directed. |
| 26 | Granite (of any type) work 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like including pointing in white cement (1:2) using marble dust with admixure of pigment to match with shade of granite including 15mm thick screed of CM 1:4 after applying cement slurry@3 kg/sqm of cement per sqm, complete all as specified.(Note : A hole shall be drilled in the Granite after fixing for gas pipe all as directed). |
| 27 | Providing cement concrete type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate), 50 mm thickas in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand ( all by weight), complete all as specified and as directed. |
| 28 | 25mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base/ floor finishing surface even and fair, complete all as specified. |
| 29 | Repair to balcony/facia and soffit of chajjas etc by taking down old plastered surfaces and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30sqcm in width or girth & applying rendering 15 mm thick dubbing coat where required to match with the existing thickness in CM 1:4including formwork/scaffolding work upto height 7.00mtr & applying two coats of exterior emulsion weather proof paint (Apex) as reqd over one coat of primer above ground level of bldg complete all as specified and as directed. |
| 30 | Reinforced cement concrete (nominal mix) type B-0 1:2:4 (using 12.5mm graded crushed stone aggregatge) for Chajjas/Balcony/Landing work. |
| 31 | Formwork to sides and soffits/faccia of floor or roof beams, beam haunchings, girders, bressummers, lintels, chajja, cantilevers, shelves including supports, overhangs, etc. complete all as specified and directed. |
| 32 | TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified. |
| 33 | Reinforced cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate ) as inslabs supported on walls, beams and columns in floor,roofs,landings,balconies,canopies,shelves, deck slabs and in similar works, complete all as specified . |
| 34 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Vertical , Horizontal or sloping)sidesincluding sup- ports, overhangs,for fair finished surface of concrete etc. complete all as specified and directed. |
| 35 | Taking down chowkhats or frameswith shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each complete all as specified and as directed. |
| 36 | Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 m and n.exc 4.00 Sqm each complete all as specified and as directed. |
| 37 | Taking down shutter of any description area not exc 1 Sqm each, complete all as specified and directed. |
| 38 | Mild steel framed workas in door or gate of angle or other section with gusset plate, rail braces complete drilled for fixing of steel sheeting or other covering . door etc to be prepared for hanging of sliding with grills, grating etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, conforming to Fe-410-W(Gde-E-250) quality-B, complete all as specified and directed . |
| 39 | Pressed steel frames of sizes 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, providing mild steel 6 mm dia threshold bar complete all as specified and directed. |
| 40 | Pressed steel frames of sizes 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, providing mild steel 6 mm dia threshold bar complete all as specified and directed. |
| 41 | Plain cement concrete 1:2:4 type B-0 (Using 12.5 mm graded crushed stone aggregate) as in back filling of pressed steel frame, 50 mm thick parapet coping all as specified and directed. |
| 42 | Plain Cement Concrete 1:3:6 type C-1 (Using 20mm graded crushed stone aggregate) for hold fast blocks, including necessary form work for rough finished surfaces etccomplete all as specified and as directed. |
| 43 | Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing, complete all as specified and directed. |
| 44 | Factory made solid Panel PVC( door/almirah shutter/cupboard) shutter 30mm thick (style) consisting of frames made out of MS tubes for tip and bottom rails M.S frames shall be covered with heat channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rails, lock rail and bottomrail on either side and as a gap insert for top rail and bottom rails, Panelling of plain colour PVC sheet to be fitted in the MS frame welded/slealed to the stiles and nails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at side as per specification and drawing. |
| 45 | 35mm thick Flush shutters, solid core with particle board exterior grade as per IS-2202 of 1999 (Part-I).Flush door shutter shall be internally lipped as per clause 8.55.2 of SSR-2009 Part-I complete all asspecified and directed. |
| 46 | Glazed and skelton shutters 35 mm thick second class hard wood, opened rebated and prepared to receive glass, guaze (without sashbars) wire mesh etc, edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing wire mesh etc. Size of members of shutters as specified in SSR Part-I, Sec-8, clause 8.24(a) complete all asspecified and directed. |
| 47 | Pre laminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame in repairs as cupboard shelve and shutter, 12 mm thick. (Kitchen cup board/covered bottom shelf of cooking platform) fixed in repairs complete all as specified and directed. |
| 48 | Pre-laminated particle board, exterior grade, laminated on one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame and necessary item like hasp and staple , in repairs as cupboard/Alimirahshelve and shutter, 18/19 mm thick, complete all as specified. |
| 49 | External teak wood lipping 6 mm thick fixed with nails for 18/19 mm thick board, complete all as specified. |
| 50 | 03 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified and as directed. |
| 51 | 04 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified and directed. |
| 52 | Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staple complete all as specified and directed. |
| 53 | Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified and as directed. |
| 54 | Aluminium anodised barrel tower bolt 150mm extruded section ISI marked complete all as speicified. |
| 55 | Aluminium handles cast type anodised of size 100mm long ISI marked with screws complete all as specified and as directed. |
| 56 | Aluminiumanodised sliding door bolts with hasp and stapple extruded sectionor cast aluminium alloy with length of bolt as 300 mm including fixing bolts complete all as specified. |
| 57 | Mild steel springs for doors, 300 mm, ordinary rat tail rod pattern including roller and roller plate complete all as specified. |
| 58 | Floor door stopper 100mm overall length of cover plate of aluminium alloy body and tongue,anodised,with hard drawn steel spring,fixed in bottom body of door complete all as specified and as directed. |
| 59 | Curtain rod ,20 mm dia Stainless steel ,chromium platedfixed with CP bracket, incl taking down of old curtain rods, complete all as specified. |
| 60 | Steel windows glass/gauzedshutters (Box type) factory madeof size 79mmx39mm,16 gauge rectangular tubular frame withside hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts in each shutter 100mm long with & including 8mm square bar grills, complete all as specified & as shown on drg No. CEUZ/TD/1517/15 Sh No 1/3 to 1/3 .Note:-(a) Fixed type glass panes shutter if any provided in above same window shall be measured and paid separately & area of these fixed shutter shall be deducted from total area of box type window for payment purpose. (b) Sheet glass/ wire cloth shall be measured & paid separately under respective item |
| 61 | Factory made box type steel ventilators top hung shutter shutters glass/glazed including guard bars ,hinges,steel handle,tower bolt and steel peg stay,complete with or without glazing bars ,devotiled or welded,including one coat of red oxide primer complete shown as drawing No (CEUZ/TD/1517/15 Sh No 1/3 to 3/3) |
| 62 | Preparation new steel and iron surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and as directed. |
| 63 | Preparation of new untreated wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of pink primer all as specified and directed. |
| 64 | Vitreous china squatting pan \"Orissa Pattern\" size 580 x 440 mmin white/ coloured with integral foot rest incl lime mortor, \"S\" trap fixed in repairs complete all as specified and directed of make specified in list make as approved by GE. |
| 65 | PVC valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete, fixed in repairs complete all as specified and as directed. |
| 66 | Vitreous china wash basin, white, flat back, size 550x400mm including waste fitting chromium plated brass, chromium plated steel chain and rubber plug, porcelain stopper, a pair of CI brackets and waste pipe etc., fixed in repairs complete all as specified and as directed of make as specified in the list of makes as approved by GE. |
| 67 | CP Sink mixer central hole basin mixer with popup waste system with 450mm long braided hoses (15mm cartridge size) fixed in repairs all as specified in the list of Makes as approved. |
| 68 | Supply only PVC connection 15mm size with PTMT nuts on both ends of length 600mm |
| 69 | S & F in repairCP angle valve/concealed stop cock (weight not less than 0.40Kg as mentioned in SSR part- 1 clause no. 18.14.2)of cast copper alloy (ISI Marked) chromium plated fancy type screwed down high pressure with capstain head screwed both ends for iron pipe 15mm bore complete all as specified and directed. |
| 70 | Stop valves/angle valve, cast copper alloy, chromium plated fancy type screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions, for bore dia of pipe 15 mm, supplied and fixed in repairs complete all as specified. |
| 71 | CP Brass wall mixture with Telephonic shower arrangement for mixing hot and cold water supply screwed down incl connecting legs & wall flanges for iron pipe 15mm dia bore fancy type as in repairs complete all as specified and directed. |
| 72 | Corner glass shelf assembly consisting of 5.5 mm thick sheet glass shelf with chromium plated bracket guard complete all as specified and directed. |
| 73 | Chromium Plated stainless steel towel rail 20mm dia \"D\" type 60 cm longbetween flanges complete all as specified and directed. |
| 74 | Brass chromium plated shower rose 125mm sizewith or without swivel joints, with arm any size, including fixing to steel pipe or union complete all as specified and directed |
| 75 | 600mm x 450mm size bevelled edge mirror with border, selected quality 5mm thick glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 76 | Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed. |
| 77 | Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed. |
| 78 | Mild steel galvanized steel tubing medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete ofbore15 mm all as specified and directed. |
| 79 | Mild steel galvanized steel tubing medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete of bore 20 mm all as specified and directed. |
| 80 | Dismantling water tanks of cap exc 500 but n.exc 1000 ltr all as specified. |
| 81 | Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) 3 layered hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified and directed. |
| 82 | Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe20 mm dia (minimum weight 210 gms) complete all as specified. |
| 83 | 20mm bore gun metal glove or gate valve with iron wheel head screwed both end for iron pipe and fixed in repairs,complete all as specified and as directed. |
| 84 | Taking down eaves gutters and rain water pipe , soil and waste pipe (any size or pattern), including all fittings, heads , shoes bends , swan-necks etc complete all as specified and directed. |
| 85 | 110mm bore PVC SWR Type-B (pressure not less than 6 Kg/cm2) pipes single socket in any length with rubber joints fixed to wall with PVC/MS holderclamp etc complete all as specified and as directed. |
| 86 | 110mm bore PVC SWR Type-B (pressure not less than 6 Kg/cm2) pipes single socket in any length with rubber joints and laid in trenches in floors withcomplete all as specified and as directed. |
| 87 | 75mm bore PVC SWR Type-B (pressure not less than 6 Kg/cm2) pipes single socket in any length with rubber joints fixed to wall with PVC/MS holderclamp etc complete all as specified and as directed. |
| 88 | 75mm bore PVC SWR Type-B (pressure not less than 6 Kg/cm2) pipes single socket in any length with rubber joints and laid in trenches in floors withcomplete all as specified and as directed. |
| 89 | PVC (SWR)bend 110 mm dia any radiusall as specified and directed |
| 90 | PVC (SWR)junction single (single T) equal or unequal provided with access door 110 mm dia in repair all as specified and directed |
| 91 | 75mm PVC (SWR) bends any radius provided withaccess door, complete all as specified and as directed. |
| 92 | PVC (SWR)junction single (single T) equal or unequal75 mm diaall as specified and directed |
| 93 | PVC (SWR)branch piece of 75 bore pipe, single (single Y) equal or unequal ordinary or inverted (spigot or socket type) provided with access door in repairs complete all as specified and directed. |
| 94 | PVC SWR vent cowl75 mmcomplete all as specified and as directed. |
| 95 | PVC (SWR)75 mm dia floor trap plain with grating including jointing with solvent cement fixed in repairs, all as specified and directed |
| 96 | Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends to stays to wall or roof of 100mm bore of pipe |
| 97 | Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends to stays to wall or roof of 75mm bore of pipe |
| 98 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortarof 150 mm diameter incl bends, complete all as specified and directed. |
| 99 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 100 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out etc in any type of soil, complete all as specified and directed. |
| 101 | PCC 1:2:4 type B-0 (Using 12.5mm graded crushed stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles including necessary form work complete all as specified and directed. |
| 102 | Plain Concrete bed to drain pipes in PCC 1:3:6 type C-2 (Using 40mm graded crushed stone aggregate) including packing under and haunching against the side of pipes after they are laid and tested for 150mm internal dia of pipe, complete all as specified and directed. |
| 103 | RCC classNP3 150mm dia drain pipes laid in trenches and jointed with & including coller complete all as specified and directed. |
| 104 | Pre cast reinforced cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregates) as in manhole cover slabs including use and waste of necessary formwork complete all as specified and directed. |
| 105 | TMT Bar 8mm dia bar and over cut to length, bent to shape required including cranking, bending, hooking ends, binding, with and including mild steel wire (annealed) not less than steel wire 0.9mm dia or securing with clips, complete all as specified and directed. |
| 106 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified and directed. |
| 107 | Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed. |
| 108 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, internal dia of pipe in 150mm, complete all as specified and directed. |
| 109 | Demolition of existing old tarfelt, water proofing membrane including roof tiles, cement mortar screed, concrete base of any thickness and roughing surfaces to receive roof treatement including removal of debris from MoD land, complete all as specified and as directed. |
| 110 | 15mm thick plaster on roof / concrete surfaces incl parapet etc in cement mortar 1:3 and finished even and smooth without using extra cementand mixed with waterproofing compound as per manufacturers instructions. (Note. WPC shall be measured and paid separately). |
| 111 | Supply only liquid water proofing compound conforming to IS 2645-1975 of approved make complete all as specified and directed.(Dosage- @ 200ml per 50Kgs of Bags of cement) |
| 112 | Roof treatment :- Water proofing treatment to RCC roof slab including parapet as under :- (a) 1st Course: Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer.(b) 2nd Course : Applying evenly a tack coat of industrial bitumen grade 85/25 conforming to IS-702 at rate of 1.2 Kg/Sqm. (c) 3rd Course :APP (Atactic Polypropylene) modified polymeric membrane, 5 layered,3 mm thick weight not less than 3.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints.(d) 4th Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. (i) On Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions.(ii) Coved fillet in PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of required radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6).Note :(i) Roof treatment work shall be carried out through approved manufacturers only or through their authorised personal only. |
| 113 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed. |
| 114 | Machine cut kota stone 20-25mm in vertical surfaces such as riser of steps skirting dado and pillar etc over and including 10mm thick plaster in CM 1:4 Complete all as specified and as directed. |
| 115 | Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular), area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm (size of tiles 600x600mm), as in floors, set and jointed in neat cement slurry and pointed in colouredcement laid over & including 15mm thickscreed bed or bedding layer in cement mortar 1:4,complete all as specified and directed. |
| 116 | ditto all as per item No 115 but as in skirting including 10mm thick plaster in CM 1:4 complete all as specified and directed |
| 117 | Plain Cement Concrete 1:2:4 Type B-0 (using 12.5 mm graded crushed stone aggregrate) as in floor finished even and fair for receiving tiles complete all as specified and directed. |
| 118 | Broken stone boulder hardcore of guage nexc 63mm deposited, spread and levelled in layers n exc 15cm thick watered and rolled/rammed to a true surface, complete all as directed. |
| 119 | 100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc, finished fair & even complete all as specified and directed. |
| 120 | Sand cushioning in flooring below interlocking tiles laid in layers 25mm thick complete all as specified and directed. |
| 121 | Machine pressed precast concrete interlocking paver block of any shape and size approved by EIC, conforming to (IS:15658-2006)60mm thick,M-35 grade , in paths and hardstanding,with grey cement and coloured pigment, laid tightly overand joints filled with dry sand. (Colour and pattern as approved by GE) complete all as specified and directed. |
| 122 | Preparation of newly plastered surfaces of walls and applying 3mm thick wall care putty over one coat primer and applying two coat of oil bound distemper complete all as specifed and directed. |
| 123 | Complete removal of existing treatment of walls and applying 03mm thick wall care putty over one coat of interior wall primer and applying two coat of oil bound distemper complete as specified and directed. |
| 124 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power)complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed complete all as specified anddirected. |
| 125 | Point wiring complete with 1.5 sqmm PVC insulated, FRLStype, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc. metal flush boxwith top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloursandincluding 1.5 Sqmm PVC insulated multistranded FRLStype unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor theOne light point/fan /bell pointcontrolled by one switch.(Note:- Allnecessary accessories such asmodular steelbox,top cover plate, blank plate, screws,washers are to be used of same make/brand onlyand shall be deemed in to included in quoted rate only.) |
| 126 | One light point controlled by one switch |
| 127 | One 3 pin 5 amps socket point controlled by one 5 amps switch on independent board |
| 128 | One 3 pin 5 amps socket point controlled by one 5 amps switch on same board |
| 129 | All as per item No 125 above but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:- (a) One 6 Pin 16/6 amps socket outletr point controlled by one 16 amps switch on independent board. |
| 130 | Supply only Modular type switch 10 Amps, single pole,1way,1/2 module,240V, ISI Markedcomplete all as specified and directed. |
| 131 | Supply only Modular type switch 16 Amps, single pole, 1way,1/2 module, 240V, ISI Marked Complete all as specified and directed. |
| 132 | Supply only Modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module, 240V, AC ISI Marked Complete all as specified and directed. |
| 133 | Supply only Modular type socket shuttered type 16 Amps, 2/3 Pin combined 2 module, 240V, AC ISI Marked Complete all as specified and directed. |
| 134 | Angle lamp holder, insulated body with back plate for LED lamp including removing old unsv itemcomplete all asspecified and directed. |
| 135 | Ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed |
| 136 | LED light fitting 1x20W, 4 feet, 220V, general purpose surface and wall mounted LED batten with aluminium housing integrated electronic driver LED fitting connecting up with three core flexible copper conductor cable of suitable size from ceiling rose as approved by GE fixed in repairs complete all as specified and directed. |
| 137 | LED light fitting 1x10W, 2 feet, 220V, general purpose surface and wall mounted LED batten with aluminium housing integrated electronic driver LED fitting connecting up with three core flexible copper conductor cable of suitable size from ceiling rose as approved by GE fixed in repairs complete all as specified and directed. |
| 138 | LED INVERTER batten 20 watt 4 feet with square profile and poly carbonate channel lithium ion battery with charging time 8 to 10 hours and backup time upto 4 hoursand connecting up with twin core twisted copper wire from LED fitting to ceiling rose as approved by GE and removing old unserviceable fitting complete all as specified and directed. |
| 139 | LED bulb 12 watts, 240Volts,50Hzpin type as approved by GE andincluding removing old unserviceable itemcomplete all as specified and directed. |
| 140 | LED secruity light fitting of capacity25 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protectionwith suitable inbuilt surge protector and cable connection from ceiling rose to light fitting and testing as approved by GE and including removing of old unserviceable item complete all as specified and directed. |
| 141 | Supply & fixing and in repair sheet metal enclosure acrylic door 240 volts AC,SPNdistribution board 8 way suitable for flush mounting with 100amps copper busbar,neutral bar,earth barand MCB incomer of rating upto 100Amps ,MCB SPN/DP,and MCB SP as outgoing and complete connecting cable linkswith top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat all as specified and as directed. |
| 142 | MCB SP 6 to 32 Amps 10 KA,\"C\" series,AC,240Volts,50Hz , ISI marked complete all as specified and directed. |
| 143 | MCB single pole & neutral 40 to 63 amps 240 volts 10 KA \"C\" series complete all as specified. |
| 144 | Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6CM with Reinforcement bars of 8mm dia @120mm c/c excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed. |
| 145 | Exhaust fansingle phase metal body, AC 230 Volt, 50 Hz, 900 RPMof size 300mm sweep with louvers shutter complete with all accessories as in list of Makes approved by GE and connecting up from ceiling rose incl taking down old u/s Exhaust Fans and depositing the same to MES Store Yard complete all as specified and directed. |
| 146 | Sub main wiring complete with 2 runs of 6 sqmm single core copper conductor (ISI marked)cable1100 volts grade,FRLS type, PVC insulated, unsheathed, flexible, multi strandedcolour coded cables drawn throughrigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLStype as earth continuity conductor connected to common earth dollyincluding making good the disturbed surfaces to match with existing surface including taking down of old existing submain cable complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 147 | Ceiling fans complete with blades. Down rods, electronic regulator and accessories, 230 volt, 1400mm sweep, min air delievery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) as in list of Makes and as approved by GE incl taking down existing and depositing the same with MES store yard all as specified and directed. |
| 148 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 35 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 149 | Supply and laying pipe galvanised Medium Class including fittings 25mm (1.0) dia all as specified and directed. |
| 150 | 25 mm dia bore gun metal globe or gate valve with iron wheel head screwed both end for iron pipe fixed in repairscomplete all as specified and directed. |
| 151 | Single pole and neutral enclosure with two pin and earth plug and socket with one single pole MCB of capacity 20 amp 240 volts and connecting electrically including taking down unserviceable enclosure with U/S MCB complete all as specified and directed. |
| 152 | Supply and fixing in replacementelectric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece incl making holes on walls for proper fixing with nuts and bolts complete making the surface good as per existing all as specified and directed. Note : Old u/s geysers shall be deposited with the MES store yard. |
| 153 | Double walled corrugated (DWC) HDPE pipe of size 90mm including snap firt coupler conforming to IS16098 (Pt-II), SN4 pressure rating for protection of underground cable complete all as specified and directed. Make : SFMC, SUPREME, FINOLEX, KISAN, PRINCE |
| 154 | Excavation in trenches not exceeding1.5 m wideand not exceeding 1.5 m deep for foundationof pole and laying LT cable including gettingout in any type of soil complete all as specified and directed. |
| 155 | Modular type switch 06 Amps, single pole,1way,1/2 module,240V, ISI Marked fixed in repairscomplete all as specified and directed. |
| 156 | Ceiling fans complete with blades. Down rods, electronic regulator and accessories, 230 volt, 1200mm sweep, min air delivery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) as in list of Makes incl taking down existing and depositing the same with MES store yard all as specified and directed. |
| 157 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 25 sqmm 2.0 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 158 | Supply and fixing of Double wall corrugated (DWC) HDPE tubing 40/32 mm bore for open/underground laying cable, cut to size and making thetubing forcable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate.(b) The insulation of DWC pipe should be of high that does not deteriorate withUV rays/ heavy sun rays/winter season etc.(c)Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates. Make : SFMC, SUPREME, FINOLEX, KISAN, PRINCE |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail