| Sl. No. | Item Description |
| 1 | Dismantling of plain or corrugated steel sheeting, any gauge, thickess including Nainital or similar pattern roofs covering complete all as specified and directed. |
| 2 | Dismentling single layer mangalore pattern or similar tiles in roofing complete all as specified and directed. |
| 3 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 4 | Taking down existing roof treatment of any type with PCC padding, cleaning of roof top by brooming down with steel wire brush, scrapping down with steel scrapper and roughening surfaces of old roof and washing down with water to remove dust etc. complete all as directed. |
| 5 | Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillets complete all as specified and directed. |
| 6 | Demolition of cement concrete unreinforced in ground floors and pavings n.exc. 15 Cm thickness (below or above ground level) complete all as specified and directed. |
| 7 | Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing), removing tiles and rubbish off the premises complete all as specified and directed. |
| 8 | Taking down cement or cement lime plaster on walls/ concrete/roof slab any description including racking out joints hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 9 | Taking up or down existing GI tubing and connections, including making good the disturbed surface for 15 mm dia pipes complete all as specified and directed. |
| 10 | Taking up or down existing GI tubing and connections, including making good the disturbed surface for 20 mm dia pipes complete all as specified and directed. |
| 11 | Taking up or down existing GI tubing and connections, including making good the disturbed surface for 25 mm dia pipes complete all as specified and directed. |
| 12 | Taking up or down existing GI tubing and connections, including making good the disturbed surface for 40/50 mm dia pipes complete all as specified and directed. |
| 13 | Taking down Chowkats or frames with shutter (without taking off shutters from the frame) n. exc. 1.50 sqm each complete all as specified and directed. |
| 14 | Taking down Chowkats or frames with shutter (without taking off shutters from the frame) exc. 1.50 sqm and n. exc. 4.00 sqm each complete all as specified and directed. |
| 15 | Taking down shutters of any descriptionn. exc. 1 Sqm each complete all as specified and directed. |
| 16 | Taking down shutters of any descriptionexc 1 sqm & n. exc 2 sqmeach complete all as specified and directed |
| 17 | Taking down shutters of any descriptionexc 2 sqmeach complete all as specified and directed |
| 18 | Taking down shutters of any descriptionexc 1 sqm & n. exc 2 sqmeach and refixing in same opening after easing and adjusting including refixing builders hardware as required and renewal of screws etc. complete all as specified and directed |
| 19 | Demolition of Brick Work/ stone work / concrete block wall built in cement mortar including all quoins, arches, pillars, etc. of any descriptions, complete all as specified and as directed. |
| 20 | Dismantling of stone slabs and tiles of any description and thickness as in floor, apron etc. laid dry or laid dry and pointed complete all as specified and directed. |
| 21 | S&F rolled mild steel in roof trusses(framed), trussed purlins, crane gantries, rails and fastenings, MS pipe for post and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe- 290(Gde E-165) complete all as specified and directed. |
| 22 | S&F rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe- 290 (Gde E-165) complete all as specified and directed. |
| 23 | S&F mild steel work as in bands, hold fasts, wall ties, wind tie straps, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hooks for hanging, plain angle cleats, plain angle cleats support and stay for rain water pipes, clamps and similar articles conforming to Fe- 290. Gde-E-165 complete all as specified and directed. |
| 24 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 25 | S&F Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, ridge, hip and vally gutters, fixed with self tapping screws as specified complete all as specified and directed. |
| 26 | Filling and reinstating of separation cracks: Opening the separation cracks at the junction of RCC and masonry where ever directed and instructed into \"V\" Grooves 2 to 3\" from either side of the cracks by carefully marking areas to be opened up using a cutting machine and skillfully/carefully chiseling with a well sharpened chisel and hammer as directed including wire brushing and washing of concrete substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the consultant as instructed and directed. Moistening the cracks, provinding and applyin priming/bonding coat of slurry made out of \"Polyalk EP\" and cement (or equivalent as specified in the list of brand names) in proporiton 1:1 to surfaces prepared as instructed and directed. Filling the cracks/grooves by providing and applying \"Polyalk EP\" Polymer modified cement mortar (or equivalent as specified in the list of brand names) in proporiton 1:5:15 (Polyalk EP: Cement: Graded Sand/Quartz Sand) on the prepared surfaces and finishing it in the level with the existing plaster including hand packing, curing and making the surface similar to the external plastering using wooden floats/punch etc. complete all as specified and directed. |
| 27 | M&L for 25 mm thick cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in padding on roof surface for levelling/ making proper slope finished even and fair without using extra cement complete all as specified and directed. |
| 28 | M&L for rendering/screeding 15 mm thick on roof slab in cement mortar 1:3 mixed with liquid WPC @ 200 ml per bag of cement finished fair and even without using extra cement complete all as specified and directed.Note:- WPC shall be measured and paid seperately |
| 29 | M&L for laying water proofing treatment using 4 mm thick APP modified membrane consisting five layers membrances with features as specified weighing not less than 3.50 kg per sqm reinforced with non woven polyester fiber @ 160 gm/Sqm laid over a coat of cold applied bituminous primer @ 0.40 kg/sqm by torching the membrance and sealing the over lap by 100 mm length side and 150 mm width side all as per manufacturer instructions including joints and changes in direction be curved with cement mortar 1:3 mixed with SBR latex @ 200 ml/bag of cement curved well before laying membrance and applying two finishing coats of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm (each coat) complete all as specified and directedNote: (i) Irrespective of lap the net covered area will only be measured for payment. (ii) Rate is inclusive of APP membrane, SBR Latex, primer, aluminium paint etc. |
| 30 | Providing & fixing false ceiling at all heights With Semi perforated 12 mm thick micro tegular edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patternshaving moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4) -1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 grams per Sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000 mm, cross-T of size 15 x 32 mm of length 1200 mm and secondary intermediate cross-T of size 15 x 32 mm of length 600 mm to form grid module of s1ze 600 x 600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1m length and L shape level adjuster of size 85 x25 x 2 mm. Galvanised iron perimeter wall angle of size 24 x 24 x 0.40 mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws complete all as per specifications, drawing and as directed. |
| 31 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed. |
| 32 | M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles lad over & including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed. |
| 33 | M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular)to match floor tiles fixed on vertical surfaces such as dado, skirting etc. jointed and pointed in white or coloured cement to match the existing surface with & including rendering 10 mm thick in cement mortar 1:4 finished rough to fix tiles complete all as specified and directed. |
| 34 | M&L for light shade vitrified ceramic tiles 9-10 mm thick(square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed. |
| 35 | M&L for light shade vitrified ceramic tiles 9-10 mm thick(square/rectangular) polished, to match floor tiles fixed on vertical surfaces such as dado, skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including rendering 10 mm thick in cement mortar 1:4 finished rough to fix tiles complete all as specified and directed. |
| 36 | M&L for joint free glazed ceramic coloured tiles or ceramic designer tiles of size 450 x 350 x 7 mm thick in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface with & including rendering 10 mm thick in cement mortar 1:3 finished rough to fix tiles complete all as specified and directed. |
| 37 | M&L for granite stone 18 to 20 mm thick (of any type) glazed(table rubbed and polished) fixed as in steps, jambs, pillars, window cills, cooking plateform and the like set in cement mortar 1:4 and pointed with white cement (1:2) using marble dust with admixture of pigment to matchand exposed edges rounded laid over and including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed. |
| 38 | M&L for precast cement concrete block masonry, type C-1 (1:3:6) (20 mm graded aggregate) with solid blocks, exc 10 cm in width and setting in CM 1:6 complete all as specified and as directed. |
| 39 | M&L for rendering on fair faces of brick work or concrete surface or block masonary, 15 mm in CM 1:4, mixed with liquid water proofing compound as per manufacturer instructions finished the surface even and smooth without using extra cement complete all as specified and directed. Note:- WPC shall be measured and paid seperately |
| 40 | M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
| 41 | M&L for rendering 5 mm thick on ceiling in cement mortar 1:3including finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 42 | M&L for applying one coat of alkali resistant primer on plasteredsurfaces of ceiling over 1.5 mm thick wall care putty and applying two coat of oil bound distemper including preparation of new surfaces complete all as specified and directed. |
| 43 | M&L for applying one coat of alkali resistant primer on plasteredsurfaces of wall over 1.5 mm thick wall care putty and applying two coat of oil bound distemper including preparation of new surfaces complete all as specified and directed. |
| 44 | Material and labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004 alkali and fungal resistance, dirt resistance exterior emulsion paint of required shade (Company Depot tinted) with silicon addtitives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 Sqm etc on newly plastered surface of wall including preparation of surface complete all as specified. |
| 45 | M&L complete removal of existing treatment of wall and applying one coat of alkali resistant primer on plasteredsurfaces of wall over 1.5 mm thick wall care putty and applying two coat of oil bound distemper including preparation of old surfaces complete all as specified and directed. |
| 46 | M&L complete removal of existing treatment of ceiling and applying one coat of alkali resistant primer on plasteredsurfaces of wall over 1.5 mm thick wall care putty and applying two coat of oil bound distemper including preparation of old surfaces complete all as specified and directed. |
| 47 | M&L complete removal of existing treatment of wall and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004 alkali and fungal resistance, dirt resistance exterior emulsion paint of required shade (Company Depot tinted) with silicon addtitives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 Sqm etc on old plastered surface of wall including preparation of surface complete all as specified. |
| 48 | M&L for preparation of old surface of wall and applying one coat of oil bound distemper complete all as specified and directed. |
| 49 | M&L for preparation of old surface of ceiling and applying one coat of oil bound distemper complete all as specified and directed. |
| 50 | M&L for applying one coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004 alkali and fungal resistance, dirt resistance exterior emulsion paint of required shade (Company Depot tinted) with silicon addtitives on old plastered surface of wall/chajja/roof projection including preparation of surface complete all as specified. |
| 51 | Supply only liquid water proofing compound |
| 52 | M&L for preparation of new or previously untreated steel surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed. |
| 53 | M&L Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings. |
| 54 | M&L Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings. |
| 55 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS 1868 with minimum anodic coating of grade AC 15) of approved design/ pattern with approved standard section and fixed to the existing window frame with CP brass/ stainless steel screw @ 200 mm centre to centre including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete all as specified and directed. |
| 56 | S&F solid PVC door frame of size 50mmx 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube and fixed with screws and rawl plugs complete all as specified and directed. |
| 57 | S&F Factory made wire gauzed PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; The wire gauzed shall be wrapped on an additional 8 mm square MS solid tube and this tube shall be welded to Main MS tube. The wire gauge shall be streatched to tighten firmly complete all as specified and directed. |
| 58 | M&L for 4 mm thick sheet glass ordinary quality and fixed with oil putty or rubber beading, aluminium strip where required fixed in aluminium windows/ doors/ partition/ ventilators complete all as specified and directed.Note :- Aluminium glazing strip/ metal strip paid sepetately under respective item. |
| 59 | S&F solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturer\"s complete all as specified and directed. |
| 60 | S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 61 | S&F aluminium (extruded section) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed complete all as specified and directed. |
| 62 | S&F floor door stopper of of brass body and tongue with hard drawn steel spring, fixed in floor having overall length of cover plate 150 mm completeall as specified and directed. |
| 63 | S&F brass mortice lock 4 levers, vertical type, of size 65 mm including plate and two keys including making hole in pressed steel frame completeall as specified and directed. |
| 64 | S&F aluminium anodised barrel tower bolt of extruded section 200 mm long and fixed complete all as specified and directed. |
| 65 | S&F 100 mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed completeall as specified and directed. |
| 66 | S&F extruded aluminium alloy handles, fabricated type, anodised 150 mm size completeall as specified and directed. |
| 67 | S&F aluminium anodised barrel tower bolt of extruded section 125 mm long and fixed complete all as specified and directed. |
| 68 | S&F 75 mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed completeall as specified and directed. |
| 69 | S&F extruded aluminium alloy handles, fabricated type, anodised 125 mm size completeall as specified and directed. |
| 70 | S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed allas specified and directed. |
| 71 | S&F in repairs steel rolling shutters, with lath thickness of 1.25 mm without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, complete gear operated type with bevel gear box and crank handle complete all as specified and directed |
| 72 | Supply only safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.NOTE:- Fixing of locks will be included in rates of S&F of rolling shutters. |
| 73 | Supply only Ball bearing for rolling shutters complete all as specified and directed.NOTE:- Fixing of ball bearing will be included in rates of S&F of rolling shutters. |
| 74 | M&L for preparation of new or previously untreated steel surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint all as specified and directed. |
| 75 | Supply, fixing, laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing \"medium grade\" with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing complete all as specified and directed. |
| 76 | Supply, fixing, laying & testing 20 mm dia (Nominal bore) galvanised iron water tubing \"medium grade\" with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing complete all as specified and directed. |
| 77 | Supply, fixing, laying & testing 25 mm dia (Nominal bore) galvanised iron water tubing \"medium grade\" with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing complete all as specified and directed. |
| 78 | Supply, fixing, laying & testing 32 mm dia (Nominal bore) galvanised iron water tubing \"medium grade\" with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing complete all as specified and directed. |
| 79 | Supply, fixing, laying & testing 40 mm dia (Nominal bore) galvanised iron water tubing \"medium grade\" with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing complete all as specified and directed. |
| 80 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and ctting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20 cm girth as in brick wall complete all as specified and directed. |
| 81 | Disconnecting existing water tank of capacity exc. 500 ltr but not exc. 1000 ltr, setting aside (or lowering of required) for repairs to roofs etc. and hoisting if required reconnecting and refixing in position on roof complete all as specified and directed. |
| 82 | Cleaning and removing all scale and dirt, etc, with bleaching power, brushfrom mouths of circulating pipes etc capacityexc 500 and not exc 1000 Ltr each including write date of cleaning and next due date complete all as specified and directed. |
| 83 | Dismantling water tank capacity exc. 500 ltr but n.exc. 1000 ltr complete all as specified and directed. |
| 84 | S&F in position rotational moulded polyethylene water storage tanks 1000 lts capacity (cylinderical verticalwith closed top) hoisted and fixed in position incl GI/CPVC tank nipple all as specified in SSR Part I complete all as directed |
| 85 | S&F in repair 20mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 86 | S&F 20mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 87 | S&F in repair 10 ltr PVC valveless, syphonic action type, flushing cistern, low level, white, with intel, ball valve, float and handle including brackets complete all as specified and directed |
| 88 | S&F in repair Viterous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed. |
| 89 | S&F in repair vitreous china wash hand basin, white,flat back 550 x 400 mm excluding tap but including brackets 2 numbers including cutting for and pinning in ends of brackets, 32 mm CP brass waste coupling and waste pipe with long screwed shanks and fly-nuts, flange end bedded in red lead cement complete all as specified and directed. |
| 90 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 91 | S&F in repair PVC connection 450 mm long suitable for 15/16 mm pipe with two PTMT nuts & rubber washers complete all as specified and directed. |
| 92 | S & F in repair stop valve/angle valve 15 mm nominal bore cast copper alloy, fancy type, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed. |
| 93 | S&F in repair stop valves 15 mm nominal bore, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfllly handles, screwed both ends for iron pipe or for brass ferrule or to GI socket complete all as specified and directed . |
| 94 | S&F in repair long body bib taps, cast copper alloy, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule orto GI socket complete all as specified and directed. |
| 95 | S&F in repair pillar taps, long nose, cast copper alloy, with capston heads, fancytype, chromium plated, screwed down high pressure with or without lettered \"Hot\" or \"cold\" with long screwed shanks and flynuts screwed for 15 mm bore iron pipe and fixed complete all as specified and directed. |
| 96 | S&F in repair 600 mm x 450 mm x 5.5 mm thick bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and aluminium angle alround fixed to wooden plugs with chromium plated brass screws & washers complete all as specified and directed. |
| 97 | S&F in repair 20 mm dia brass chromium plated tubular towel rail, D type, 60 cm long between flanges fixed with rawl plug completeall as specified and directed. |
| 98 | S & F in repair Brass CP mixer for mixing hot & cold water screwed down for iron/CPVC pipe and fixed complete all as specified and directed. |
| 99 | S&F in repair grating doom 100 mm dia of PTMT minimum weight not less than 25 grams complete all as specified and directed. |
| 100 | S&F in repair 75 mm dia PVC (SWR) floor trap, with stainless steel grating including jointing to waste pipe with solvent cement and fixed in cement concrete 1:2:4 type B1(using 20 mm graded stone aggregate) complete all as specified and directed. |
| 101 | S&F in repair chromium plated brass shower roses 125mm dia with or without swival joints, including fixing to 15 mm dia pipe or union all as specified. |
| 102 | S&F in repair PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and laid in trenches or in floors complete all as specified and directed. |
| 103 | S&F in repair PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and laid in trenches or in floors complete all as specified and directed. |
| 104 | S&F PVC (SWR) bend 110 mm dia, any radius fixed to pipe complete all as required and as directed. |
| 105 | S&F PVC (SWR) bend 75 mm dia, any radius fixed to pipe complete all as required and as directed. |
| 106 | Removing building materials by truck or tractor with using of if necessary JCB machine and trolly load min 5.00 Cum each load including loading, unloading and stacking at the destination and depositing out side defence land complete all as specified and directed. |
| 107 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, copings, over chajja, walls and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work and necessary scaffolding/ staging/ Jhula etc. with necessary safety precautions upto 4 story height complete all as specified and directed. |
| 108 | S&F in repair toilet paper holder with flat recessed type stainless steel complete all as specified and directed. |
| 109 | M&L for 75 mm thick cement concrete type C-1 1:3:6 (using 20 mm stone graded crushed stone aggregate) as in plinth protection surface finished even and smooth without using extra cement including forming construction (dummy) joints 6 mm wide & 10 mm deep and filled with filler at an interval not exceeding 3 metre and at change of direction and necessary formwork complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail