| 1 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses , fillets , columns , pillars , piers , abutments , posts and struts etc. upto floor five level excluding cost of centering , shuttering , finishing and reinforcement - 1:1.5:3 (1 cement : 1.5 fine aggregate : 3 graded stone aggregate 20mm nominal size) |
| 2 | Reinforced cement concrete work in beams, suspended floors , roofs having slope up to 15degree landings , balconies , shelves , chajjas , lintels , bands , plain window sills , staircases and spiral stair cases above plinth level up to floor five level excluding the cost of centering ,shuttering, finishing and reinforcement , with 1:1.5:3 (1 cement : 1.5 fine aggregate : 3 graded stone aggregate 20mm nominal size) |
| 3 | Centering and shuttering including strutting , propping etc and removal of form for - Lintels , beams , plinth beams , girders , bressumers and catilevers |
| 4 | Centering and shuttering including strutting , propping etc and removal of form for - Columns , Pillars , Piers , Abutments , Posts and Struts |
| 5 | Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete above plinth level - Thermo - Mechanically Treated bars Fe - 500D or more |
| 6 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level upto floor V level - cement mortar 1:4 (1 cement : 4 fine aggregate) |
| 7 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 fine aggregate) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 8 | Providing wood work in frames of doors , windows, clerestory windows and other frames , wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) - Forest teak wood |
| 9 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part 1) decorative type , core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters - 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 10 | Extra for providing lipping with teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured) |
| 11 | Providing and fixing M.S.grills of required pattern in frames of windows etc with M.S. flats , square or round bars etc. including priming coat with approved steel primer all complete - Fixed to openings / wooden frames with rawl plugs screws etc |
| 12 | Providing and fixing aluminium tower bolts , ISI marked , anodised (anodic coating not less than grade AC 10 as per IS :1868) , transparent or dyed to required colour or shade , with necessary screws etc. complete - 300 x10 mm |
| 13 | Providing and fixing aluminium handles , ISI marked , anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc, complete - 125 mm |
| 14 | Providing and fixing aluminium hanging floor door stopper , ISI marked , anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc complete - Twin rubber stopper |
| 15 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance +_ 1mm ), with wall thickness 2.0 mm (+-0.2mm) , corners of the door frame to be jointed with galvanized brackets and stainless steel screws , joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S.tube of size 19 x 19 mm and 1mm (+-0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer\"s specification and direction of Engineer-in-charge - Extruded section profile size 48 x 40 mm |
| 16 | Providing and fixing to existing door frames - 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59 x 24 mm and wall thickness 2 mm (+- 0.2 mm) with inbuilt edging on both sides . The styles and rails mitred and joint at the corners by means of M.S. galvanised / plastic brackets of size 75 x 220 mm having wall thickness 1.0 mm and stainless steel screws . The styles of the shutter reinforced by inserting galvanised M.S.tube of size 20x20 mm and 1mm (+- 0.1mm) wall thickness . The lock rail made up of \"H\" section , a uPVC hollow section of size 100 x 24 mm and 2 mm (+-0.2 mm) wall thickness , fixed to the shutter styles by means of plastic / galvanised M.S. \"U\" cleats. The shutter frame filled with a uPVC multichambered single panel of size not less than 620 mm, having overall thickness of 20 mm and 1 mm (+_ 0.1mm) wall thickness . They panels filled vertcally and tie bar at two places by inserting horizontally 6 mm galvanised M.S.rod and fastened with nuts and washers , complete as per manufacturer\"s specification and direction of Engineer-in-charge - (For W.C. and bathroom door shutter) |
| 17 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50m in height dimension comprising of uPVC multi - chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 + or - 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile , zinc alloy (white powder coated) touch locks with hook ,zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I. fastners 100 x8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shyall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc.After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality , all complete as per approved drawing.(Single / double glass panes , wire mesh and silicon sealent shall be paid separately) - Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels ) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 + or - 0.2 mm and single glazing bead of appropriate dimension.(Area of window upto 1.75 sqm) - sliding window size 1.20x1.35 m |
| 18 | Cement concrete pavement with 1:2:4 (1 cement : 2 fine aggregate: 4 graded stone aggregate 20 mm nominal size) including finishing complete |
| 19 | Providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as white, Ivory, Grey, Fume red brown ,laid on 20mm thick cement mortar 1:4 (1 cement : 4 fine aggregate), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigment etc., complete |
| 20 | Providing and laying vitrified floor tiles of size 600 x600 mm (thickeness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 of approved make , in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 fine aggregate) ,jointing with grey cement slurry @3.3 kg per sqm including grouting the joints with white cement and matching pigments etc., complete - size of tile600x600mm |
| 21 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 75mm diameter |
| 22 | Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - bend 87.5 degree - 110 mm bend |
| 23 | Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - shoe (plain) - 110mm shoe |
| 24 | Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs , screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 fine aggregate) and making good the wall etc., complete - 110mm |
| 25 | 15mm cement plaster on the rough side of single or half brick wall of mix - 1:4 (1cement : 4 fine aggregate) |
| 26 | 20mm cement plaster of mix -1:4 (1 cement : 4 fine aggregate) |
| 27 | White washing with lime to give an even shade - new work (three or more coats) |
| 28 | Painting with synthetic enamel paint of approved brand and manufacutre to give an even shade - Two or more coats on new work |
| 29 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content - with water thinnable cement primer on wall surface having VOC content less than 50 grams / litre |
| 30 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade- One or more coats on old work |
| 32 | Finishing walls with Acrylic Smooth exterior paint of requireshade - Old work (two or more coat applied @ 1.67 litre / 10 sqm) on existing cement paint surface |
| 33 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty - Float glass panes of nominal thickness 4mm( weight mot less than 10kg /sqm) |
| 34 | Raking out joints in lime or cement mortar and preparing the surface for repointing or replastering , including disposal of rubbish to the dumping ground all complete as per direction of Engineer-in-charge |
| 35 | Flush pointing with cement mortar 1:3 (1 cement : 3 fine aggregate) mixed with 2% of integral water proofing compound by weight of cement for flat tile bricks on top of mud phaska - with F.P.S. brick tiles |
| 36 | Demolishing lime concrete manually / by mechanical means and disposal of material within 50 metres lead as per direction of Engineer-in-charge. |
| 37 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. - Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 38 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction ofEngineer-in-charge.- in cement mortar |
| 39 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead - of area 3 sqm and below |
| 40 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead - for thickness of tiles 10mm to 25mm |
| 41 | Dismantling G.I.pipes (external work) including excavation and refilling trenches after taking out the pipes, manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge.- above 40mm nominal bore |
| 42 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead |
| 43 | Providing and fixing white vitreous china water closet squatting pan (Indian type) - long pattern W.C. pan of size 580mm |
| 44 | Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings this included jointing of pipes & fittings with one step ASTM solvent cement , trenching refilling & testing of joints complete (External work) - 32 mm nominal outer dia pipes |
| 45 | Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings this included jointing of pipes & fittings with one step ASTM solvent cement , trenching refilling & testing of joints complete (External work) - 40 mm nominal outer dia pipes |
| 46 | Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 25mm nominal bore |
| 47 | Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 32mm nominal bore |
| 48 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked , with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 49 | Providing and fixing PTMT bib cock of approved quality and colour - 15mm nominal bore, 122 mm long , weighing not less than 99 gms |
| 50 | Providing and fixing PTMT stop cock of approved quality and colour - 20 mm nominal bore , 89mm long, weighing not less than 88 gms |
| 51 | Grading roof for water proofing treatment with - Cement concrete 1:2:4 (1 cement : 2 fine aggregate : 4 graded stone aggregate 20 mm nominal size) |
| 52 | Chipping of unsound / weak concrete material from slabs , beams , columns etc. with manual Chisel and / or by standard power driven percussion type or of approved make including tapering of all edges , making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-incharge- 50 mm average thickness |
| 53 | Chipping of unsound / weak concrete material from slabs , beams , columns etc. with manual Chisel and / or by standard power driven percussion type or of approved make including tapering of all edges , making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-incharge - 25 mm average thickness |
| 54 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry , all complete as per direction of the Engineer-incharge- Bars upto 12mm diameter |
| 55 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams , lintels , columns and slabs to introduce steel bars for sunshades / balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement , all complete as per direction of the Engineer-in-charge- Upto and including 12mm dia |
| 56 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. 26.31.1SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 57 | Providing , mixing and applying SBR polymer (of approved make ) modified Cement mortar in proportion of 1:4 (1 cement : 4 graded fine aggregate with polymer minimum 2% by wt.of cement used) as per specifications and direction. Note: Measurement and Payment : The Pre-meaurement of thickness shall be done just after the surface preparation is completed and payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and / or the 75mm size cube crusing strength at the end of 28 days to be not less than 30 N / Sqmm) - 25 mm average thickness in two layers |
| 58 | Providing , mixing and applying SBR polymer (of approved make @ minimum 2% by wt.of cement used) modified plain / reinforced cement concrete for structural members having minimum charscteristic compressive strength ( with ordinary portland cement , coarese sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) with specified average thickness . Note: Rates shall be for finished surface area of concrete and shall include the cost of labour , concrete and appropriate approved Super - Plasticiser for rendering concrete as flowable and SBR polymer but shall exclude cost of reinforcement , bond coat , Shear Keys , centering and shuttering , strutting , propping etc., (Payment under this item shall be made only after proper wet curing has been done andsurface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument) - 50 mm thick in Grade M 25 with cement content not less than 330 kg per cum |
| 59 | Water proofing treatment of RCC sunshade with Zycosil / equivalent water proofing solution (1 litre of Zycosil / equivalent & 20 litres of water stirred first & 2 litres of Zycoprime/equivalent added and stirred (total 23 litres) till it meets the saturation level and testing as per RILEM or by water drops test in which water drops do not absorb but drops remain or rolls |
| 60 | Providing two legged scaffolding using 15 cm diameter blue - gum posts or casurina posts or best quality bamboo - posts of 4m over all length (3.0m height + 0.5 m projection + 0.5 into the ground) the distance between the two rows being 1.25 m and the spacing of posts with 0.5 m overlap on either side and braces to step up and providing a platform with country wood planks of 40mm thick and 1m width etc in a complete form using coir and nails 1 m run (Rate of scaffolding for a height of 3 m and lenghth of 1 m) |
| 61 | Exta for Providing two legged scaffolding for every additional height of 2.5 m (Rate for scaffolding for a height of 3 m and length of 1m) |
| 62 | Providing leak proof centering and shuttering using 25mm thick plywood for damage slab / beam to carrying out micro concreting work including ceiling the gaps if any with renderoc plugging compund and removal of form work. |
| 63 | Laying of Non shrink free flow micro concrete renderoc RG or equivalent in the proportion 1:1 (One renderoc Rg : one graded stone aggregate of 12.5mm) and below through the drilled holes till the voids and damaged area are completely filled and set to an average thickness of 50mm as directed by the Engineer-in-charge. |