| 1 | CIVIL |
| 2 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 4 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) |
| 5 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 6 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 7 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 8 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require |
| 9 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete |
| 10 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour ,600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms |
| 11 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.20 mm nominal dia Pipes |
| 12 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter |
| 13 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.20 mm nominal dia Pipes |
| 14 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kind |
| 15 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 16 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry@ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 17 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., completeSize of Tile 800 x 800 mm |
| 18 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer- in-Charge. |
| 19 | 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of \"H\" section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. \"U\" cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer\"s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). |
| 20 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 21 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal wood |
| 22 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in charge. (Note:- Butt hingesand necessary screwsshall be paid separately) 30 mm thick |
| 23 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 24 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : |
| 25 | 200x10 mm |
| 26 | 150x10 mm |
| 27 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : |
| 28 | 250x16x5 mm |
| 29 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3sqm and below |
| 30 | Providing and fixing health faucet of approved quality and manufacture complete. |
| 31 | Providing and fixing CP brass angle cock of approved quality andmanufacture complete.15 mm |
| 32 | Providing and fixing PTMT bib cock of approved quality andcolour15 mm nominal bore, 86 mm long ,weighing not less than 88 gms |
| 33 | Providing and fixing nominal guage PVC Pipe of approved qualitycompleate with special flang compression type fittingsincluding trenching and re filling etc. External work |
| 34 | 32 mm nominal bore |
| 35 | 63 mm nominal bore |
| 36 | 110mm nominal bore |
| 37 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 38 | With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) |
| 39 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modifiedself curing mortar, including disposal of rubbish, all completeas per the direction of Engineer-In-Charge. |
| 40 | ELECTRICAL |
| 41 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 42 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 43 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 44 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 45 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 46 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 47 | 5/6 A switch |
| 48 | 15/16 A switch |
| 49 | 3 pin 5/6 A socket outlet |
| 50 | 6 pin 15/16 A socket outlet |
| 51 | Bell push |
| 52 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections, but excluding modular plates etc.. |
| 53 | Supply and fixing following sizes/ Modules, GI box along with Modular base and cover plate formodular switches in recess etc as required. |
| 54 | 1 or 2 Module |
| 55 | 3 Module |
| 56 | 4 Module |
| 57 | 6 Module |
| 58 | 8 Module |
| 59 | 12 Module |
| 60 | Supplying and fixing 3pin, 5A cealing rose on the existing junction box/ wooden block including connections etc. as required. |
| 61 | Supply and fixing call bell /buzzer suitable for 230V complete as required |
| 62 | Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-260 Volt, frequency 50/60 hz, (8w to10w) |
| 63 | Installation, testing and commissioning ofwall brackets/ceiling fittings of all sizes and shapes containing uptotwo GLS/CFL/LED lamps per fitting,, complete with all accessories, including connections etc required |
| 64 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 65 | Dismantling of ceiling fan and painting with the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reels, nuts and bolts with washers and safety pins, reinstalling the same as required. |
| 66 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 67 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 68 | Single Pole |
| 69 | Single Pole and neutral |
| 70 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required. |
| 71 | 63 A |
| 72 | Supplying and fixing following rating, double pole, (single phase and neutral), 214 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. as required. |
| 73 | 40 A |
| 74 | Supplying and fixing following rating, four pole, (Three phase and neutral), 415 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. as required. |
| 75 | 63 A |
| 76 | Supply and laying 6 SWG GI wire at 0.5 meter below ground level for conductor earth electrode, including connection/termination with GI thimble etc as required |
| 77 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board vertical type, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 78 | 12 Way double door |
| 79 | Supplying and fixing following way, Three pole and neutral, sheet steel, MCB distribution board vertical type, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 80 | 8 way (4+18) Double door |
| 81 | DATA |
| 82 | Supplying and fixing of 25 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 83 | Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required. |
| 84 | 1 or 2 Module (75mmX75mm) |
| 85 | Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required. |
| 86 | one run |
| 87 | Dismantling of unserviceable following electrical items including stacking with same as per engineer-in-charge |
| 88 | Tube light 40/20W |
| 89 | Ceiling fan / Exhaust fan |
| 90 | CFL / Bulk head |
| 91 | Wiring wire with conduit |
| 92 | Supplying of LED Tubelight set 20w 1800 lumen 4 feet |
| 93 | Supplying of PVC Bulkhead with Suitable LED bulb |
| 94 | LED lamp 7W/9W |
| 95 | Earthing with GI earth pipe 32mm dia 2.5m long including accessaries, nut and bolt washer etc complete as required. |
| 96 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 97 | 32A DP Switch |