Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Civil works |
| 2 | CARRIAGE OF MATERIALS.Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transportincluding loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, completeas per directions of Engineer-in-charge |
| 3 | Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means includingstacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :In cement mortar |
| 4 | Removing mortar from and cleaning stones and concrete articles (net quantity of stacks of cleaned materials will be measured): In cement mortar |
| 5 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below |
| 6 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead Of sectional area 40 square centimetres and above |
| 7 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : Of sectional area below 40 square centimetres |
| 8 | Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional span of one metre or part thereof beyond 10 metres Of sectional area 40 square centimetres and above |
| 9 | Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional span of one metre or part thereof beyond 10 metres : Of sectional area below 40 square centimetres UOM AU:Metre per metre span |
| 10 | Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional height of one metre or part thereof beyond 5 metres : Of sectional area 40 square centimetres and above |
| 11 | Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional height of one metre or part thereof beyond 5 metres : Of sectional area below 40 square centimetres UOM AU: Metre per metre height |
| 12 | Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in R.S. Joists |
| 13 | Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: Channels, angles, tees and flats |
| 14 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 15 | Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one metre or part thereof beyond 10 metresUOM AU: Kg per metre span |
| 16 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 17 | Dismantling tile work in floors and roofs laid in cement mortar includingstacking material within 50 metres lead For thickness of tiles above 25 mm and up to 40 mm |
| 18 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet |
| 19 | Dismantling roofing including ridges, hips, valleys and gutters etc., andstacking the material within 50 metres lead of: Asbestos Cement sheet |
| 20 | Dismantling and stacking within 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of: R.C.C. |
| 21 | Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. |
| 22 | Dismantling expanded metal or I.R.C. fabrics with necessary battens and beading including stacking the serviceable material within 50 metres lead. |
| 23 | Dismantling wooden boardings in lining of walls and partitions, excludingsupporting members but including stacking within 50 metres lead : Up to 10 mm thick |
| 24 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead : Thickness above 10 mm up to 25 mm |
| 25 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead : Thickness above 25 mm up to 40 mm |
| 26 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 75 to 80 mm dia pipe |
| 27 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 100 mm dia pipe |
| 28 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 150 mm dia pipe |
| 29 | Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50metres lead as per direction of Engineer-in-charge : bituminous road |
| 30 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical meansincluding stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore |
| 31 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction ofEngineer-in-charge : Above 40 mm nominal bore |
| 32 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: Up to 150 mm diameter |
| 33 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: Above 150 mm dia up to 300 mm dia |
| 34 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: Above 300 mm diameter |
| 35 | Dismantling steel cylinder R.C. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical meansbreaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metres lead as per direction of Engineer-in-charge : Up to 600 mm diameter |
| 36 | Dismantling steel cylinder R.C. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical meansbreaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metres lead as per direction of Engineer-in-charge : Above 600 mm diameter |
| 37 | Dismantling asbestos cement pressure pipes including excavation and refilling trenches after taking out the pipes manually/ by mechanicalmeans and stacking the pipes within 50 metres lead as per direction of Engineer-in-charge : Up to 150 mm diameter |
| 38 | Dismantling asbestos cement pressure pipes including excavation and refilling trenches after taking out the pipes manually/ by mechanicalmeans and stacking the pipes within 50 metres lead as per direction of Engineer-in-charge : Above 150 mm diameter |
| 39 | Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ bymechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. |
| 40 | Taking out C.I. cover with frame from R.C.C. top slab of inspection chambers of various sizes including demolishing of R.C.C. work manually/by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. |
| 41 | Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. |
| 42 | Dismantling of flushing cistern of all types (C.I./PVC/ Vitreous China) including stacking of useful materials near the site and disposal ofunserviceable materials within 50 metres lead |
| 43 | Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres Up to 150 mm diameter |
| 44 | Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres Above 150 mm diameter |
| 45 | Dismantling of spindle fire hydrant including stacking of useful materials within 50 metres lead |
| 46 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 47 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer in-charge. |
| 48 | Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. |
| 49 | Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in-charge. |
| 50 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 51 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 52 | Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. (iv) Beyond 30 cm girth up to and including 60 cm girth |
| 53 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge |
| 54 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 14.2.1 Door chowkhats |
| 55 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.14.2.2 Window chowkhats |
| 56 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.14.2.3Clerestory window chowkhats |
| 57 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class Acategory with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In Charge.(Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 26.87.235 mm thick |
| 58 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 59 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) |
| 60 | Refixing old glass panes with putty and nails |
| 61 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres |
| 62 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 63 | Brick work withcommonburnt clayF.P.S.(non modular) bricks ofclass designation 7.5 in foundation and plinth in: Cement mortar 1 :4(1 cement: 4 coarse sand) |
| 64 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead For thickness of tiles above 25 mm and up to 40 mm |
| 65 | ProvidingandlayingCeramicglazedfloortilesofsize 600x600mm (thickness tobespecifiedbythemanufacturer) of1st quality conforming toIS:15622 ofapprovedmakeincolourssuchasWhite,Ivory,Grey, Fume RedBrown,laid on20mm thick cement mortar 1 :4(1Cement : 4 Coarsesand),Jointing withgreycement slurry @ 3.3 kg/sqmincluding pointing the joints with white cement and matching pigment etc., complete. |
| 66 | Providing and fixing1st quality ceramic glazed tiles conforming toIS : 15622 (thickness tobe specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Chargeinskirting,risersof stepsanddados over12 mmthickbedofcementMortar1 :3(1cement:3 coarsesand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment ofmatching shade complete. |
| 67 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 68 | Painting with oil type wood preservative of approved brand and manufacture:Old work (one or more coats) |
| 69 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work |
| 70 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 71 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 72 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : Newwork(twoormorecoats)overandincludingwater thinnable priming coat with cement primer having VOC content less than50 gram/litre |
| 73 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90litre/10 sqm) |
| 74 | Providing & fixing at all heights, levels and locations colour finish Aluminum alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming toIS737anddimensionsasperIScode2676withcharacteristicsof goodformabilityandcorrosionresistance.Theprofilesheetsshallbe fixedtotrussmembersin slope orrequiredpitchor curvature withHex capheadedself drilling/tapping Stainless steelscrewsM6,50mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc.complete asper directions oftheEngineer-In-Charge.(Cost of truss/frame work shall bepaid separately). 0.56mm,AluminumColorcoatedtroughedprofilewith center to centerpitchof200mm,depthof 32 mm,overall profile width1092 mm, cover width1000 mm. |
| 75 | Steel workinbuilt up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete. |
| 76 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (bothside inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flangesof 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finishof tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitablyfixed, all complete as per drawings, specification and direction ofthe Engineer in Charge but excluding the cost of painting with |
| 77 | 125 mm wide Stay in Place PVC Wallform made of minimum 2.50 mm thick sections and minimum weight 21.97 kg /sqm of formwork |
| 78 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 79 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Mild steel and Medium Tensile steel bars |
| 80 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Hard drawn steel wire |
| 81 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Cold twisted bars |
| 82 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Hot rolled deformed bars |
| 83 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Hard drawn steel wire fabric |
| 84 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-5000 or more. |
| 85 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer all complete. |
| 86 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 87 | Welding by gas or electric plant including transportation of plant at site etc. complete. |
| 88 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube |
| 89 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.E. R. W. tubes |
| 90 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.G.I. pipes |
| 91 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 92 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides |
| 93 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 94 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 95 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 96 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 97 | Disconnecting damaged overhead/terrace PVC water storage tankofany size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. |
| 98 | Providing & placing tank 4 LProviding and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank |
| 99 | Providing & placing tank 2 LProviding and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank |
| 100 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 101 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 102 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked black solid plastic seat and lid |
| 103 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaflushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 104 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaflushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked black solid plastic seat and lid |
| 105 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 106 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern |
| 107 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern |
| 108 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern |
| 109 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern |
| 110 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern |
| 111 | Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automaticflushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required : Range of two squatting plates with 5 litre P.V.C. automatic flushing cistern |
| 112 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 113 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 114 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 115 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 116 | Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : White solid plastic seat with lid |
| 117 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. |
| 118 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia |
| 119 | Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 120 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 121 | Providing and fixing toilet paper holder |
| 122 | Providing and fixing soil, waste and vent pipes : 100 mm dia,Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
| 123 | Providing and fixing soil, waste and vent pipes :75 mm,Centrifugally cast (spun) iron socketed pipe as per IS: 3989 |
| 124 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 125 | Providing and fixing Polyethelene-Aluminium- Polyethelene PE-AL-PE Composite Pressure Pipes conforming to IS : 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with trenching, refilling and testing of joints complete as per direction of the engineer in charge. External work 18.3.64050 (50 mm OD ) pipe |
| 126 | Providing and fixing Polyethelene-Aluminium- Polyethelene PE-AL-PE Composite Pressure Pipes conforming to IS : 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge.Concealed work, including cutting chases and making good the wall etc. 18.2.2 1620 (20 mm OD) pipe |
| 127 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work150 mm nominal dia Pipes |
| 128 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work100 mm nominal dia Pipes |
| 129 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in- charge. |
| 130 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 25mm average thickness. |
| 131 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter. |
| 132 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars above 12 mm diameter. |
| 133 | Providing Shear Connector 16mm dia:-Supply and fixing of rebarring chemical FOSROC LOKFIX E75- pure Chemical anchor grout or equivalent for various diameters of reinforcement bar provide embedment depth as per the manufacturer’s specifications and instructions for use in concrete applications as directed by Engineer in charge. 16mm dia rebar at 240mm depth |
| 134 | Providing Shear Connector 12mm dia:- Supply and fixing of rebarring chemical FOSROC LOKFIX E75- pure Chemical anchor grout or equivalent for various diameters of reinforcement bar provide embedment depth as per the manufacturer’s specifications and instructions for use in concrete applications as directed by Engineer in charge. 12mm dia rebar at 180mm depth |
| 135 | Providing Shear Connector 10mm dia.:- Supply and fixing of rebarring chemical FOSROC LOKFIX E75- pure Chemical anchor grout or equivalent for various diameters of reinforcement bar provide embedment depth as per the manufacturer’s specifications and instructions for use in concrete applications as directed by Engineer in charge. 10mm dia rebar at 150mm depth |
| 136 | Providing Shear Connector 8mm dia.:- Providing and applying Share connector using rotary hammer drill machine and dust removing, batching, mixing of resin and hardener, inserting & anchoring re bars of specified dia in existing concrete surfaces using polyster resin based anchoring grout of make Fosroc Lokfix ,Hilti RE 500or equivalent and necessary re baring of reinforcement steel up to 15D mm depth. 8 mm dia |
| 137 | Application of Bonding Agent:- Providing and applying structural grade long pot life epoxy bond coat of Nitobond EP or equivalent prior to building up of section with any type of mortar/ concrete to ensure bond between old concrete & new concrete by brush application as per the manufacturers specifications. (Mode of measurement- per sqm of application of concrete surface ) |
| 138 | Patching of damaged concrete surface withstructural grade polymer modified reinstatement mortar to like Fosroc Renderoc S2 or equivalentat a thickness of 10 to 20mm as per instructions of manufacturer and as approved by the Engineer.The prepacked repair mortar should have a compressive strength 45 N/mm²,Flexture strength 8 N/mm² at 28 Days. |
| 139 | Epoxy Grout:-Providing and Sealing the cracks, or grouting in the concrete surface, after opening the cracks using suitable tools or saw cut in the crack, and cleaning the interior sides of the crack using sharp tools to remove all loose materials, using two component, high strength, non-sag, epoxy compound Nitobond PC 40 of fosroc make or equivalent, inclusive of all Manpower, Material and Equipment. Injection Of Low Viscous Resin: BY Providing and grouting the cracks after fixing the injection ports at predetermine locations with the help of suitable injection grouting pumps at suitable pressures using two component, high strength, low viscous epoxy injection resin system such as Conbextra EP 10 of Fosroc or equivalentinclusive of Manpower, Material and Equipment\". (Mode of measurement: Per litre of grout consumption. |
| 140 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy |
| 141 | Cementitious Grout:-Injecting cement slurry 1:3 (1 cement: 3 water) by weight including mixing of grout compound (CEBEX 100 of FOSROC or equivalent) as per manufacture specifications, in cracks/effected RCC work under low pressure upto 0.50 kg/cm2 though already fixed 12 mm dia PVC nipples complete as per direction of Engineering charge.(Fixing of PVC nipples shall be paid separately) |
| 142 | Micro Concreting:-Concreting of the structurewith free flow no shrink cementitious micro concrete with Renderos RG of Fosroc or equivalent after proper mixing with clean water including formwork followed by proper curing for 28 days as per manufacturer\"s specifications complete and as directed by the Department . |
| 143 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100 mm upto 200 mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/ balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. Upto and including 12 mm dia. |
| 144 | Supplying, fitting and placing TMT bar reinforcement in sub-structure complete as per drawing and technical specifications. (i) \"TMT CRS ( Fe-500)reinforcement bar |
| 145 | 12mm cement plaster:-Applying of 12 mm cement plaster finished with a floating coat of neat cement of mix(1 cement: 3 fine sand) |
| 146 | 20 mm cement plaster:-Applying of 20 mm cement plaster finished with a floating coat of neat cement of mix(1 cement: 3 fine sand) |
| 147 | Providing and applying Nitocote CM210 or equivalent, an elastomeric cementitious coating approved under the UK WBS (WRc Listed) Scheme No. 0510522 or equivalent upto a thickness of 1mm. The cured coating, after immersion, shall be capable of withstanding cracked substrate cyclic movement from 0 - 300 - 0 microns at 15°C for 6,000 cycles without failure. It shall have the capability to resist a positive water pressure of 5 bar as per DIN 1048,Pt 5 and a negative water pressure of 2 bar when tested to ITM / FTM-181. The cured coating, shall have the capability to static crack accommodation 0.9mm with Abrasion resistance as per ASTM D4060 : Wear Index (equivalent to 40 N conc.) with CO diffusion resistance (Taywood method) > 50 m .Application should be as per manufacturer\"s methodology. |
| 148 | ProvidingandlayingSBRPolymermodified(ofapprovedmake@ minimum 2% by wt. of cement used) plain/reinforced concrete jacket for the structural members e.g. columns, pillars, piers, beams etc with concretehavingthespecifiedminimumcharacteristiccompressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] with specified average thickness all-round existing core of RCC member. Note: Rates shall be for finished surface area of concrete and shall include the cost of making holes in existing RCC slab, if required, for pouring concrete in shuttering mould of jacket and appropriate approved Super-Plasticiser for rendering concrete as flowable self compactingand SBR polymer but shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering, strutting, propping etc (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument) |
| 149 | Cuplock scaffolding:-Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.**This item will not be used with any other items where scaffolding is already included. |
| 150 | Waterproofing:- Supplying and applying Polyurethane (PU) membrane (Moist cured)over the existing exposed terrace afterproper surface preparaton, crack treatment where ever required, repairing the Khura etc., complete.The scope of work includes the following sequence of operations.PRIMECOAT:-Priming should be done using two component epoxy based,water dispersed VOC freePrimer at a covarage of 0.2-0.4 Kg/Sqm using brush/ roller or asrecommended by manufacturer .The primer should have mix density of1.03 +0.02 Kg/Litre& Bond strength 1.5 N/Sq mmTOP COAT:-Proving and applying a single-component, liquid applied, elastomeric polyurethane coating s like Nitoproof 600PF of Fosroc/ Sikalastic 450(I) of Sika/Aqua Arm WPU 1K E of MYK toprovides excellentresistance to moisture, water, and salts penetration into concrete and masonry surfaces. The waterproofing coating should confirm the requirement of ASTM C-836. The formed membrane should have properties at 28 days of Elongation: 450 %, Tensile strength 1.4 N/Sq mm confirming to ASTM D412 with Tear resistance: 10 N confirming to ASTM D624 . |
| 151 | Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. |
| 152 | Grading roof for water proofing treatment with i.Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 153 | Grading roof for water proofing treatment withii.Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 154 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.Measurement: Per bag of 50kg cement used |
| 155 | Electrical Works |
| 156 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C |
| 157 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 158 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 159 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 160 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 161 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 162 | Supplying anddrawing co-axialTVcableRG-6grade,0.7mmsolidcopperconductorPEinsulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 163 | supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 164 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required. 5/6 amps switch |
| 165 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required.15/16 amp switch |
| 166 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 167 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 168 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required.Telephone socket outlet |
| 169 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required.TV antenna socket outlet |
| 170 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required.Bell push |
| 171 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. |
| 172 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc asrequired. 1 or 2 Module (75mmX75mm) |
| 173 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc asrequired.3 Module (100mmX75mm) |
| 174 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc asrequired.4 Module (125mmX75mm) |
| 175 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc asrequired.6 Module (200mmX75mm) |
| 176 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc asrequired.8 Module (225mmX75mm) |
| 177 | Supplyingandfixing3pin,5ampceilingroseontheexistingjunction box/ wooden block including connection etc as required. |
| 178 | Supplying and fixing call bell/ buzzer suitable for single phase, 230volts, complete as required. |
| 179 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. asrequired. Upto 450 mm sweep |
| 180 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
| 181 | Wiringforgroupcontrolled(looped)lightpoint/fanpoint/exhaustfanpoint/callbellpoint(without independent switch etc.) with 1.5 sq. mmFRLS PVC insulated copper conductor single core cable in surface/recessedPVC conduit, and earthing the point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable etc. as required. Group-C |
| 182 | Supplying and fixing PVC batten/ angle holder including connectionsetc. as required. |
| 183 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, onsurface/ recess, complete withtinnedcopperbusbar,neutralbusbar,earthbar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door |
| 184 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, onsurface/ recess, complete withtinnedcopperbusbar,neutralbusbar,earthbar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 185 | Supplying and fixing following way, horizontal type TP&N MCB distribution board of steel sheet for 415 voltsonsurface/recesscompletewithtinnedcopperbusbar,neutrallink,earthbar,dinbar, interconnections,powderpaintedincludingearthingetc.asrequired.(ButwithoutMCB/RCCB/ Isolator) 6 way (4 + 18), Double door |
| 186 | Supplying and fixing following way, horizontal type TP&N MCB distribution board of steel sheet for 415 voltsonsurface/recesscompletewithtinnedcopperbusbar,neutrallink,earthbar,dinbar, interconnections,powderpaintedincludingearthingetc.asrequired.(ButwithoutMCB/RCCB/ Isolator)8 way (4 + 24), Double door |
| 187 | Supplyingandfixing5ampsto32ampsrating,240/415volts,“C”curve,miniaturecircuitbreaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 188 | Supplying and fixing following rating, double pole, 240 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A |
| 189 | Supplying and fixing following rating, double pole, 240 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A |
| 190 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps |
| 191 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 Amps |
| 192 | Supplyingandfixingfollowingrating,doublepole,(singlephaseandneutral),240volts,residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 Amps |
| 193 | Supplyingandfixingfollowingrating,doublepole,(singlephaseandneutral),240volts,residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps |
| 194 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness |
| 195 | EarthingwithG.I.earthpipe4.5metrelong,40mmdiaincluding accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeetc.withcharcoal/coke and salt as required. |
| 196 | Earthing with copper earth plate 600 mm X600 mm X 3 mm thick includingaccessories,and providingmasonryenclosurewith cover platehavinglockingarrangementandwateringpipeof2.7metrelong etc. with charcoal/ coke and salt as required. |
| 197 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washerspaced at 50mm) |
| 198 | Providing and fixing 4.00 mm dia copper wire on surface or in recess forloopearthingalongwithexistingsurface/recessedconduit/submain wiring/ cable as required. |
| 199 | Jointingcopper / G.I. tape (with another copper/ GI tape, base of thefinialoranyothermetallicobject)byriveting/nutbolting/sweating and soldering etc as required. |
| 200 | Supplying,installation,testingandcommissioningofAstronomical timeswitchoffollowingconfigurationtobemountedinfeeder pillars/LightingDBsforautomaticswitchingOn&OFFofstreet lightsatsunset&sunriseortwilight(AutoON,AutoOFF,Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programmingat site complete as required. 3 output (1output per phase) and suitable for three phase supply |
| 201 | Supply, Installation , Testing & Commissioning of various Type of Hanging/Surface/ Recessed Mounted/ INDOOR LED Type Lighting Fixtures. Including all support structure/ stripe /rod etc for hanging light etc: 10w LED recessed spotlight with diameter 70mm, housing made of Aluminium: PMMA Clear Diffuser & Reflector PC metalized. CREE LED, CRI >80, Lumen package of 968 Lumens. Available in 3 beam angles- spot, medium, wide. LED Life Time @L70/B10 >50,000 hours. Driver: OSRAM(Havells UNECOADJDLR12WLED) |
| 202 | Supply, Installation , Testing & Commissioning of various Type of Hanging/Surface/ Recessed Mounted/ INDOOR LED Type Lighting Fixtures. Including all support structure/ stripe /rod etc for hanging light etc: 36w LED recess 595mmx595mm Grid Ceiling Fixture. Housing made of Mild Steel with Premium High transmission Opal Diffuser. LED: Samsung Mid power, CRI >80 & LED Life Time @L70/B10 >50,000 hours. Lumen Package 0f 3793 Lumens @ 4000k. Power factor >.95. Driver OSRAM / Fulham (Havells PLANO 2X2) |
| 203 | Supply, Installation , Testing & Commissioning of various Type of Hanging/Surface/ Recessed Mounted/ INDOOR LED Type Lighting Fixtures. Including all support structure/ stripe /rod etc for hanging light etc: 20w LED Suspended Linear L:1200mm W:60mm. Extrusion made of Aluminium with Premium High transmission Opal Diffuser. LED: Samsung Mid power, CRI >80 & LED Life Time @L70/B10 >50,000 hours. Lumen Package 0f 2399 Lumens @ 4000k. Power factor >.95. Driver OSRAM / Fulham (DESTG250LR25WLED840SWH1130) |
| 204 | Supply, Installation , Testing & Commissioning of various Type of Hanging/Surface/ Recessed Mounted/ INDOOR LED Type Lighting Fixtures. Including all support structure/ stripe /rod etc for hanging light etc: 30w LED Suspended Decorative Fixture of Dia: 450mm. Housing made of Aluminium with Premium High transmission Opal Diffuser. LED: Samsung Mid power, CRI >80 & LED Life Time @L70/B10 >50,000 hours. Lumen Package 0f 1693 Lumens @ 4000k. Power factor >.95. Driver OSRAM(TORUS600RDP/S25WLED840SPM MAWH) |
| 205 | Supply, Installation , Testing & Commissioning of various Type of Hanging/Surface/ Recessed Mounted/ INDOOR LED Type Lighting Fixtures. Including all support structure/ stripe /rod etc for hanging light etc: 18Watt Surface Mounted pressure die cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver (Havells EDGESURFACERDDLR18WLED857S) |
| 206 | Supply, Installation , Testing & Commissioning of various Type of Hanging/Surface/ Recessed Mounted/ INDOOR LED Type Lighting Fixtures. Including all support structure/ stripe /rod etc for hanging light etc: surface mounting heavy duty industrial battens with best in class luminaire efficiency. (Havells STOUTPRO1200BS23WLED865PCWH) |
| 207 | Supply, Installation , Testing & Commissioning of various Type of Hanging/Surface/ Recessed Mounted/ INDOOR LED Type Lighting Fixtures. Including all support structure/ stripe /rod etc for hanging light etc: 8w/mtr Strip Light with Aluminium Profile and Diffuser (Linescape 8w/mtr (1 Driver for every 5 meter roll) |
| 208 | Supply, Installation , Testing & Commissioning of various Type of Hanging/Surface/ Recessed Mounted/ INDOOR LED Type Lighting Fixtures. Including all support structure/ stripe /rod etc for hanging light etc: 18Watt Surface Mounted pressure die cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver (Havells EDGEPRONEORDDLR15WLED857S) |
| 209 | Supply, Installation, Testing and Commissioning of1200/1400 mm sweep BLDC ceiling fan providing minimum air deliveryof 270 Cu Mtr/Minute with power consumption not more than 42 watts at the speed of 270 RPM, service value greater than 7, complete in all respect Powder coated Aluminium die cast body & blades(minimum 1 mm thick aluminium leaf), Power factor not less than 0.90 including providing 6 key remote along with necessary down rod of standard length (upto 30cms) complete as required. 1200 mm Sweep (BLDC Fan) |
| 210 | Supply of following sizes of Havey duty Exhaust fan with Louver suitable for operation on single phase 230 Volt AC 50 Hz supply complete with all fixing accessories as required. 300 mm Sweep (900 RPM) |
| 211 | Supply,installation,testingandcommissioning of cabinfans of 1350RMmade of highquality engineering plastic complete with all accessories as required in the following sizes :- 400 mm Sweep. |
| 212 | LayingofonenumberPVCinsulatedandPVCsheathed/XLPEpowercableof1.1kVgradeof following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 213 | LayingofonenumberPVCinsulatedandPVCsheathed/XLPEpowercableof1.1kVgradeof following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm |
| 214 | Supplying andmakingindoorendterminationwithbrasscompressionglandandaluminiumlugsfor following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 240 sq. mm (62 mm) |
| 215 | Supplying andmakingindoorendterminationwithbrasscompressionglandandaluminiumlugsfor following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 35 sq. mm (32mm) |
| 216 | Supplying andmakingindoorendterminationwithbrasscompressionglandandaluminiumlugsfor following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 217 | Supplying andmakingindoorendterminationwithbrasscompressionglandandaluminiumlugsfor following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25 mm) |
| 218 | Supplyof followingsizeof1.1KVgrademulticorealuminiumconductorXLPEinsulated PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required.3.5 core, 240 Sq.mm. |
| 219 | Supplyof followingsizeof1.1KVgrademulticorealuminiumconductorXLPEinsulated PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required.3.5 core, 35 Sq.mm. |
| 220 | Supplyof followingsizeof1.1KVgrademulticorealuminiumconductorXLPEinsulated PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required.4 core, 16 Sq.mm. |
| 221 | Supplyof followingsizeof1.1KVgrademulticorealuminiumconductorXLPEinsulated PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required.4 core, 10 Sq.mm. |
| 222 | Supplyof followingsizeof1.1KVgrademulticoreCopperconductorXLPEinsulated PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required. 4 core, 16 Sq.mm. |
| 223 | Supplyof followingsizeof1.1KVgrademulticoreCopperconductorXLPEinsulated PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required.4 core, 10 Sq.mm. |
| 224 | Supplying, installation, testingandcommissioning of 6meterHeighthotdippedgalvanized pole for corrosion resistance - 60% more life at 20% higher costcontinuously tapered (bolt fixing type) octagonalPolewithtop 70 mm dia and bottom 130 mm dia made of 3 mm thick H T sheet Steelconforming to grade S 355 complete with G Ibase plate of size 220 mm(L) X 220 mm(B) X 16 mmthicknesswelded at bottom of pole completewith4 Nos 20 mmdia 600 mm longfoundationboltsconformingtoEN8grade,inbuilt/Vandal resistance,weatherproofelectrical junction box having terminalblock,MCB etcmountedon Bakelite sheet forlooping in /looping out of cables,withflushdoorhavinglocking arrangement,earthingarrangement(atleast 0.5mheight) and mounted on RCC foundation of size 500 mm x 500 mm x 1200 mm in ground and 200 mm above ground level with foundation bolt duly embedded before casting and supply and embedding ofsuitable size HDPE pipe sleeve for cable entry. complete including erection of Pole complete in all respect as per specification as reqd. |
| 225 | Supplying,installation,testingandcommissioning of Ornamental Poles 3Meters- Description Below1) Design Standard EN402) Design criteria-2.1) Basic Wind Speed: 169 kmph2.2) Topography is considered as flat.3) Materials.3.1) Pole shaft: Steel tube grade YSt 240.3.2) Base plate: A36/A572-50 or equivalent.3.3) Anchor Bolts: EN8 Grade4) Hot dip galvanised to ASTM A123, with minimum average GI coatingof 65μm.5) PU(Polyurethane) painted with avg. DFT of 70μm, using very highquality paint & primer. supply and embedding ofsuitable size HDPE pipe sleeve for cable entry. complete including erection of Pole complete in all respect as per specification as reqd. NOTE :- (i) Provision of earth strip interconnections from earth pit to feeder pillar not included in above item. This shall be paid under separate items. |
| 226 | SupplyInstallation,Testing&CommissioningofIP66LEDstreetlightfittinghavingsystemlumen outputnotlessthan7000,efficacybetterthan 110lumensperwattandlifeexpectancyof50000 burning hours@L70,Power Factor> 0.90& THD<20%, CRIbetter than70,neutral white light andmadeof pressuredie cast / extruded Aluminiumhousing with separate optics and control gear compartment, toughened glass protector, permanently sealedand a removable control gear plate, , mounting spigot suitableforhorizontalmounting(Ø32–42mm)withtiltflexibilityof(+)(-)10degrees, suitablefor operationon230 V+/-10% singlephase50HzACSupply , surgeprotectionof3KVanddriver efficiency more than 85%(LED shall be ofCree/Lumileds/Nichia complete in all respect i/c connections etc as reqd. |
| 227 | SupplyInstallation,Testing&Commissioningof LED Post top luminaire, electrical Class I, with a Graphite grey paintedhigh die cast aluminium body with specially profiled cooling fins foreffective heat management, optical grade opal PC Diffuser ( IK 08 impactresistance), of IP 65 optical & Mid Watt SMD, suitable for verticalmounting of 60mm diameter. The luminaire shall have a CCT of 3000Kand Colour Rendering Index (CRI) ≥80, a driver (efficiency ≥ 85%) withinternal surge protection of 4/4 kV and external surge protection of 6/6kV (in both Common & Differential Modes), Power Factor ≥0.95, aresidual flux of 70% (L70) @ 50,000 hours. etc as reqd. |
| 228 | Supply,Installation,testingandcommissioningof1000mmlongSinglearm 60mm diabracketofapproved designandshapemadeupofMSmetalwithhotdipgalvanisedsuitableforpoletopof70mmdia complete with fixing arrangement as required |
| 229 | Supply,Installation,testingandcommissioningof1000mmlongDoublearm 60mm dia bracketofapproved designandshapemadeupofMSmetalwithhotdipgalvanisedsuitableforpoletopof70mmdia complete with fixing arrangement as required |
| 230 | Supply of LED flood light fixture suitable for Surface/ Walltype mountingwith Epoxy powder coated die -cast aluminiumhousing with heat Sink, toughened glass, completewith inbuilt electronics driver, mountingbracket,110Lumen/wattefficacy,min7000Lumenoutput,THD<10%,P.F.>0.95,IP65 rated as required |
| 231 | Providing Panel / Power distribution Boards as per IEC 61439 suitable for 415V 50Hz 3ph 4 wire supply dust and vermin proof floor/ wall mounting cubicle pattern with removable gland plates, copperbus bar, mounting frame, grouting made out of crca sheet, double door, duly powder coated painted as specified as follows. MCB with ‘C’ curve for lighting and ‘D’ curve for UPS Load will be used. MAIN LT PANEL Outdoor Type Comprising of : Incoming of 400amp 4P 36kA thermal magnetic MCCB - 02 Nos. Three Nos. Phase Indicating Lamps, Control fuses– 02 set. Analogue 0-500V Volmeter with Selector Switch - 02 set Analogue 0-400A Ameter with Selector Switch - 02 set Indication Lamps for ON, OFF & TRIP - 02 set 40 KA Class B+C Surge Supperessor - 01 No. Load Manager (V, A, Hz, KW, KVA, KVAR, PF, KVAh, KVARh, THD FOR A&V, MD KVA) – 02 Nos. 600 A TPN Tinned Aluminium. Busbar 50kA for 1 sec. - 01 Set. with Changeover-1nos Outgoing – 80 A TPN 36 kA MCCB - 10 No. 125 A TPN 36 kA MCCB- 01 No. 63A 4P 10 kA C Curve MCB - 4 Nos. |
| 232 | 20KVA ( 3 Phase In/3 Phase Out ) with 30 Minute back up Supply /Install of20KVA(16 Kw)UPS System suitable for :Three Phase input : 415V AC 1PH, 3 wire +20%, -40%, 50HZ +/- 10%, ThreePhase output: 415V +/- 1%, 50HZ, DSP based IGBT Rectifier,Input Current Harmonics: <3%, Input Power Factor: >0.99, High Overall AC / AC efficiency:>96% Make: vertive |
| 233 | 20KVA ( 3 Phase In/3 Phase Out ) with 30 Minute back up Batteries for above 20KVA Supply, Install, Commission Battery back up for 30 minutes, for full load, Suitable for above UPS completeMake: Exide/Quanta |
| 234 | 20KVA ( 3 Phase In/3 Phase Out ) with 30 Minute back up MS powered coated Rack, Isolator, Inter links , cables etc . The Each battery shall be of 12Volts. The rate shall also include supply and installation of suitable rating Battery Bank Isolators installed in Sheet Steel rack and suitable nyvin cable for connectivity between UPS and battery set. The batteries shall be open type vertical rack mounting with suitable accessories. Any module should be replaceable during continuous operation without disturbing load and parameters of UPS outgoing including voltage etc. Before supply of these batteries the detail arrangement drawing is to be prepared by the vendor and the same should be get approved from the consultants and as per final direction and approval ofthe Consultant. |
| 235 | DISMENTALLING AND REMOVALRemoval of existing lighting fixture, along with conduit , wiring , cable, power sockets, cable tray as per instruction and handing over the same to facility team |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail