| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: 1 meter from cutting edge All kinds of soil 25 meter beyond 1 mfrom cutting edge |
| 2 | Supplying and laying of stone soling hand packed tightly incl ramming watering and filling of interstices incl all carriage complete job |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level.1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns |
| 8 | Structural steel work in single section, fixed with or without connectingplate, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer and synthetic paint. all complete. |
| 9 | Structural steel work in single section, fixed with or without connectingplate, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer and synthetic paint. all complete. |
| 10 | Providing wood work in frames of doors,windows, Clerestory windows and frames, wrought framed and fixed in position with hold fasts or lugs or with fasteners of required dia and length (Hold fast lugs or with dash fasteners shall be paid separately). KD Wood |
| 11 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws 2nd class Kail wood 30 mm thick ) |
| 12 | Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size with necessary screws including panellig complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). 30 mm second class kail wood |
| 13 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge ( 2nd class Kail wood 30 mm thick ) |
| 14 | P/F of 12mm thick imported wood paneling (newzealand pine or equivalent) of approved pattern overand including base of 10mm thick plywood exposed surface with two of more coats of touch wood and polish including cost of nails, adhesive material, cornices etc. and all carriages (Design of panelling to be approved by EIC) |
| 15 | P/F of 12mm thick plywood including fixing and carriages all job complete. |
| 16 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50mm thick with 20 mm nominal size stone aggregate. |
| 17 | Providing and fixing bright finished brass handles with screws etc. complete :125 mm |
| 18 | 100 mm |
| 19 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. 150x10 mm |
| 20 | 100x10 mm |
| 21 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x70x4 mm (ordinary type) |
| 22 | 75x40x2.5 mm (ordinary type) |
| 23 | Providing and fixing bright finished brass door latch with necessary screws etc. complete. : 250x16x5 mm |
| 24 | Supply, Installation, Testing and Commissioning of 3 star rating 1.5 Ton Inverter type (Hot and Cold) split Air Conditioner suitable for operation on AC supply single phase 50Hz 230V with hermetically sealed inverter compressor with air cooled condenser latest R410A/ R-32 refrigerant fan motor, start and run capacitors, relay and over load protector internal unit with one indoor and one outdoor unit. The indoor unit fitted on wall by employing suitable clamps and the outdoor unit will be placed on angle iron stand fitted with nut/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrilic foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ PVC insulated copper cable and a battery operated wireless remote unit. The job includes repairs to walls wherever the same are cut and the AMC of AC for a period of one year from date of successful commissioning. (Panasonic/Daikin/Godrej/LG/Lloyd/ Voltas)Sample to be approved before installation including Supply, Installation, Testing and Commissioning of 4KVA automatic relay type Voltage Stabilizer for 1.5 ton AC operating from input voltage 90-260V thereby producing 230+-3 output voltage.sample to be approved before installation. |
| 25 | Supplying, fitting and fixing 8mm thick AC4 Grade Waterproof Laminated woodenFlooring Work including cornice of required size with plank size not less than 1218mmx 193mm) mm (with unilin/tongue-groove locking arrangement) having 0.2mm thicktop abrasive layer over a decorative layer followed by a High-density fibreboard (HDF)having density > 850 kgJrn3 substrate core over a resin saturated backing layer andinstalling through unilin or tongue- groove system (having locking strength not less than1000 kg/m) over a 2 mm thick underlayer polyurethane foam on polythene sheet 250microns, over a smooth, flat, hard subfloor free from moisture (<8%), grease etc,complete in all respect with requisite accessories like end profile, transition profile,reducer T profile etc. wherever required and preparation of base including all otherincidental works as per direction & satisfaction of Engineer in charge |
| 26 | P/F track deck crill make or equivalent HI rib color coated profilled sheets 1000 to 1020mm cover width 28-35mm high crests at 250 to 255mm TCT (total coated thickness) high tensile SMP Galvalume steel with silicon modified ployester coating of approved colour of total thickness of 35 micron comprising 20 micron exterior coat of SMP over 5 micron polyester back coat over 5 micron primer coats on both surfaces incld. side and end lap and using 8mm galvalume hex self drilling fastener on each crest of sheet for connection with purlins and seam bolts at 300mm centers on all side and end lapps etc. (measured for unit of laid area)0.S0mm THICK (TATA,JSW OR EQ brand) I/C ALL CARRIAGES/H/LOAD |
| 27 | Providing and fixing plained eaves boarding 2nd class kail wood 250x32 mm (nominal size ) |
| 28 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work |
| 29 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete In colour such as White, Ivory, Grey, Fume Red Brown |
| 30 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 31 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of :G.S. Sheet |
| 32 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead Of sectional area 40 sqcm. and above. |
| 33 | Carriage of materials from a lead of 50km by mech transportSand and Bajri |
| 34 | Wiring for lighting points/fan points/exhaust fan points/call bell points with 2x1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch ,modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) including the cost of conduit including Supply, Installation, Testing and Commissioning of 15W/+ LED recessed/mounted (round or square) Down lighters having aluminum body |
| 35 | P/F heating plug points (15/16A heating points) with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mmFRLS PVC insulated copper conductor single core cable for loopearthing as required Please Enable Macros to View BoQ information |