| 1 | Excavation in post holes (or similar holes) each n. exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layer not exceeding 25 cm thick, watering and removing surplus soil to a distance n. exc 50m and making good surface in hard/dense soil complete all as specified and as directed. |
| 2 | Excavation in post holes (or similar holes) each n. exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layer not exceeding 25 cm thick, watering and removing surplus soil to a distance n. exc 50m and making good surface in hard rock/ PQC complete all as specified and as directed. |
| 3 | S&F mild steel rolled section as in main and cross beams, hip and jack rafter, purlins where connected to common rafters and running rails and guides, fixed with angle cleats or other connecting plates etc conforming to Fe-410W (Gde E-250) quality-A grade complete all as specified and as direted. |
| 4 | S&F mild steel work in tubular trusses/ posts including special shaped washer etc, complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St -240 complete all as specified and as direted. |
| 5 | S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of FE 410-W (Gde-E-250) quality B complete all as specified and as direceted. |
| 6 | S&F Pre-painted galvalume aluminium zink coating GI based corrugated steel sheet 0.5 mm thick of an colour having tensile strength of 550 Mpa (AZ-150) as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and as direceted. |
| 7 | S&F Pre painted galvalume aluminium zink coating GI based plain steel sheet 0.5 mm thick of an colour having tensile strength of 550 Mpa (AZ-150) as in roof covering/ cladding to wall or in ridges, valley gutters fixed with self tapping screws complete all as specified and as directed. |
| 8 | S&F flat iron fillets as in wind ties for roof including securing bolts/screw etc complete all as specified and as directed. |
| 9 | M&L for PCC (1:3:6) type C1 (using 20 mm graded stone aggregates) as in pillars, posts, copings and other similar bands and hold fast block including necessary use and waste of form work complete all as specified and as directed. |
| 10 | M&L for preparation of steel surfacesof any description, over 10 cm in width or girth, not otherwise described and providing two coats of synthetic enamel paint over a coat of red oxide primercomplete all as specified and as directed. |
| 11 | M&L for hardcore (broken stone or boulders) of guage exc 63mm but n. exc 100mm deposited, spread and levelled in layers n.exc 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed. |
| 12 | M&L for 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregates)as in sub floors, sub base, etc, surface finished even and fair without using extra cement complete all as specified and as directed. |
| 13 | M&L for 25 mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in floor, surface finished even and smooth with using extra cement complete all as per specified and as directed. |
| 14 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan, exceeding 6 mtr mean radius, built in cement mortar (1:6) complete all as specified and as directed. |
| 15 | M&L for 10mm thick rendering in cementmortar (1:6) onfairfacesofbrickworkorconcretesurfaces, finished evenandsmooth without using extra cement complete all as specified and as directed. |
| 16 | M&L for 15mm thick cementplaster on fair faces of brick work or concrete surfaces in cement mortar (1:4), surface finished even and smooth without using extra cement mixed with water proofing compound by weight as per manufacturer\"s instructions complete all as specified and as directed. |
| 17 | Supply only integral water proofing compound complete all as specified and as directed. |
| 18 | M&L for preparation of new plastered surfaces of walls and applying two coats of white wash on undecorated surface including necessary scaffolding etc complete all as specified and as directed. |
| 19 | Surface dressing not exceeding 15cm deep and getting out in hard / dense soil complete all as specified and as directed. |
| 20 | Excavating in trenches not exceeding 1.5m deep and n.exc 1.5m wide and getting out in hard / dense soil for foundation, etc. complete all as specified and as directed. |
| 21 | Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 22 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note:- A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming. |
| 23 | M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation, fillings, mass concrete, footings etc complete all as specified and as directed. |
| 24 | M&L for RCC M–25 Design Mix, (using 20mm graded stone aggregate) as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc. complete all as specified and as directed. |
| 25 | Use and removal of steel formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits [if any] of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces complete all as specified and as directed. |
| 26 | M&L for RCC M-25 Design Mix, (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts etc. complete all as specified and as directed. |
| 27 | Use and removal of steel formwork to sides of pillars, posts, struts, piers, columns and stanchions of any shape / cross section for rough finished surfaces of concrete complete all as specified and as directed. |
| 28 | M&L for RCC M-25 Design Mix, (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and as directed. |
| 29 | Use and removal of steel formwork to sides and soffits of floor or roof beams, beam launchings, girders, bressummers, lintels,cantilevers, shelves including supports, overhangs, etc, splays between floors and beams and similar works for rough finished surfaces of concrete complete all as specified and as directed. |
| 30 | M&L for RCC M-25 Design Mix, (using 20mm graded stone aggregate) as in slabs supported on walls, beams, columns, landings, shelves and the like complete all as specified and as directed. |
| 31 | Use and removal of steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] for rough finished surfaces complete all as specified and as directed. |
| 32 | S&F reinforcement using high strength corrosion resistant deformed TMT bars of grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. |
| 33 | S&F reinforcement using high strength corrosion resistant deformed TMT bars of grade Fe–500D of 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. |
| 34 | M&L for brick work with sub class B bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed. |
| 35 | M&L for preparing the surfaces of concrete roof and brushing neat cement slurry with 3.0 Kg of cement per sqm area, rendering 10mm thick in cement mortar (1:3) on concrete surfaces finished even and smooth without using extra cementincluding mixing of water proofing compound of approved make as per manufacturer\"s instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 Kg per sqm, applying a coat of blown bitumen of grade 85/25 @ 1.2 Kg per Sqm, laying polymeric water proofing membrane of weight not less than 3.00 Kg per Sqm reinforced with polyester non-woven fabric of weight notless than 150 gm per sqm, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of blown bitumen of grade 85/25 @ 1.2 Kg per Sqm and finished with a coat of bituminous aluminium paint @ 100 grams per sqm on top for water proofing treatment complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid separately. |
| 36 | M&L for 25mm average thick, PCC (1:2:4), type B-0, (using 12.50mm graded stone aggregate) as in padding over roof slabs etc. including mixing water proofing compound as per manufacturer\"s instructions and finishing the top surface rough complete all as specified and as directed.Note:- Water proofing compoundshall be measured and paid separately. |
| 37 | M&L for rendering 5mm thick in cement mortar (1:4) including mixing water proofing compound as per manufacurer\"s instructions over a backing coat of 10mm thick in CM (1:6) on concrete or brick masonry surfacesand finishing the top surface even and smooth without using extra cement complete all as specified and as directed.Note:- Water proofing compoundshall be measured and paid separately. |
| 38 | M&L for rendering 5mm thick in cement mortar (1:3) on fair faces of concrete surface of ceiling surfaces, finished even and smooth without using extra cement complete all as specified and as directed. |
| 39 | M&L for two coats of weather proof exterior emulsion paint [100% Acrylic] by using auto roller/ airless sprayer over a coat of exterior primer of same manufacturer as that of paint on newly plastered walls, pillasters, bands, borders, soffits of chajjas and projections including necessary preparation of surfaces by using vaccume based sanding machine complete all as specified and as directed. |
| 40 | M&L for preparing newly plastered ceiling surfaces and applying threecoats of white washing complete all as specified and as directed. |
| 41 | M&L for preparing newly plastered wall surfaces by using vaccume based sanding machineandapplying two coats of oil base distemper by using auto roller/airless sprayer, over a coat of alkali resistant primer over 3mm thick cement based wall care putty on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the wall surfaces complete all as specified and as directed. |
| 42 | M&L for 20mm thick granite (of any type) work (table rubbed and polished) fixed on floor/platform including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed bed or bedding layer of cement mortar (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 43 | M&L for provding false ceiling of 12mm thick fine fissure board sharped finished mineral fiber acoustic false ceilingtiles with back of the duly sanded and finshed with a coat of protective paint and front duly finished false system of size (600 x 600)mm having noise reduction co-efficient of 0.55 light reflection of 80% thermal conductivity k=0.057 W/WWC and humidity resistance of 95% fixed to true look PVC die KL -24 suspension system (Hot dipped a glvanised steel section) of exposed T Section consisting of perimeter wall angle of size (24x24)mm of thickness 0.45mm c/c universal main runner of T shape with double rotary siticing of size (38x25)mm of lenght 1200mm made from 0.33 GS steel of lenght 3.60 mtr to be specified at (600x 600)mm size c/c CRO runner T shape wtih double rotary siticing of size (30x24)mm of length 1200mm made 0.25 thick GS sheet spaced @ 600mm c/c (600mm x 600mm) size complete all as specified and directed by Engineer -in- Charge. |
| 44 | S&F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps complete all as specified and as directed. |
| 45 | S&F 110 mm bore PVC [SWR] bends of any radius including jointing with solvent cement complete all as specified and as directed. |
| 46 | M&L for hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding15cm thick watered and rolled/rammed to a true surface complete all as specified and as directed. |
| 47 | M&L for 75 mm thick PCC (1:3:6), type C-1 (using 20mm graded stone aggregate) as in plinth protection, surfaces finished even and smooth complete all as specified and as directed. |
| 48 | S&F factory made single extruded WPC (wood polymer composit) solid door/window and other frames/chowkhat of size (50x100)mm comprising of virgin PVC polymer of K value 58-60 (suspension grade) calcium carbonte and natural fibers (wood powder/rice husk/wheat husk) and non toxic aditives (maximum toxicity index of 12 for 100 gms) fabricated with full body threaded star headed SS screws having minimum frame density of 750 kg/cum screw withdrawl strength of 2200 N (face) & 1100N (Edge) minimum compressive strength of 58 N/sqmm modules of ealsticity 900 N/sqmm and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per manufacturer\"s instructions and direction of Enger-in-charge. (Make- M/s Rajshree plastiwood ltd or its equivalent) |
| 49 | S&F factory made single extruded WPC (wood polymer composit) solid decorative type flush door shutter of size 30mm thick comprising of virginpolymer of K value 58-60 (suspension grade) calcium carbonte and natural fibers (wood powder/rice husk/wheat husk) and non toxic aditives (maximum toxicity index of 12 for 100 gms) fabricated with full body threaded star headed SS screws having minimum frame density of 650 kg/cum screw withdrawl strength of 1800 N (face) & 900N (Edge) minimum compressive strength of 50 N/sqmm modules of ealsticity 850 N/sqmm and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hotmelt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws complete all as manufacturer\"s instructions and all as directed of Enger-in-charge. Make- M/s Rajshree plastiwood ltd or its equivalent) |
| 50 | S&F anodised aluminium powder coated frame for door, windows, ventilators, partition wall with one or more rebatesincluding joining cleat for fixing etc. complete all as specified and as directed |
| 51 | S&F anodised aluminium powder coated door shutter, aluminium section wt 0.55 Kg/m including neccesary joining cleats, glazing clips,rubber neoprene packing, handle 2 nos in each door, hinges, anodised aluminium snap beading screw etc. complete all as specified. |
| 52 | S&F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised, handle 2 nos in each window aluminium fittings such as peg stays150mm long (1 no.) hinges type B-21,100mm long (2 no.) suitable tower bolt (1no.) complete all as specified and as directed. |
| 53 | M&Lfor 12mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination & fixed with screws to aluminium/timber frame complete all as specified and as directed. |
| 54 | S&F 75mm size, butt hinges, stainless steel, medium weight, bright polished including fixtures complete all as specified and as directed. |
| 55 | S&F aluminium anodised handle, of extruded section fabricated type of size 75mm long complete all as specified and as directed. |
| 56 | S & F aluminium anodised barrel tower bolt of size 100 mm size of extruded section complete all as specified and as directed. |
| 57 | Supply only powder coated aluminium Deco Grill of Model / Design No. DG 104 (7.2mm x 4.2mm) including powder coated aluminium channel of size (30 x 12 x 1.5)mm for fixing Deco Grill complete all as specified and as directed. |
| 58 | Supply only 5mm thick sheet glass ordinary quality in squares exceeding 0.5 sqm in each pane complete all as specified and as directed. |
| 59 | S&F stainless steel curtain rod, 20 mm dia with fixing brackets, end caps etc complete all as specified and as directed. |
| 60 | S&F aluminium alloy anodised sliding door bolt with hasp and staple [Bolt Type] of size 250 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 61 | S&F aluminium anodised barrel tower bolt of size 300mm size of extruded section complete all as specified and as directed. |
| 62 | S&F aluminium anodised handle of extruded section fabricated type of size 150mm long complete all as specified and as directed. |
| 63 | S&F floor door stopper of size 150 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed. |
| 64 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 sqm each including cutting holes in walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified and as directed. |
| 65 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size exceeding 1.50 sqm but n. exc 4.0 sqm each including cutting holes in walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified and as directed. |
| 66 | Demolition of reinforced concrete roofs, floors (other than ground floors), beams, staircases, landing,shelves chajjas and similar suspended work complete all as specified and as directed. |
| 67 | Dismantling structural steel work including door, gates but excluding framed truss etc. complete all as specified and as directed. |
| 68 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coverings complete all as specified and as directed. |
| 69 | M&L for PCC (1:2:4), type B-1 (using 20mm graded stone aggregate) as in coping, mud stops, rounded or chamfered on edges including necessaary use and waste of form work complete all as specified and as directed. |
| 70 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. any type all as specified and as directed. |
| 71 | M&L for point wiring with single core PVC insulatedbut unsheathed 1.5 sqmm FRLS multistranded copper conductor cable 1100 volts grade IS-694 marked drawn in and including rigid non metallic PVCconcealed /surface conduit, medium grade not less than 20 mm diaISI marked with all conduit fittings and fixing accessories including modular metal flush box with modular plate for mounting switches, sockets, fan regulators, etc and earth wire single core PVC insulatedbut unsheathed multistrand copper conductor cable 1100 volts grade IS-694 marked 1.5 sqmm FRLS cable as continuous earth wire connecting to common earth dolly in concealed wiring system including making good the disturbed surface of wall complete all as specified and as directed by Engr- in- Chargefor the following :- (a) One light point controlled by one switch one way |
| 72 | (b) One ceiling fan point controlled by one switch. |
| 73 | (c) One socket outlet 5 Amp controlled by one switch on independent board |
| 74 | (c) One socket outlet 5 Amp controlled by one switch on same board |
| 75 | Description all as per Srl item No 71.00 here-in-before but for one power point 6 pin 15 Amps socket out let with 2.5sqmmstranded copper conductor cable PVC insulated including earth wire 2.5sqmm copper conductor cable connected to earth dolly complete all as specified and as directed. |
| 76 | Supply and fixing modular switch 1 way 6 Amps one module complete all as specified and as directed. |
| 77 | Supply and fixing modular socket 6 Amps 2/3 Pincombined02 module complete all as specified and as directed. |
| 78 | Supply and fixing modular switch one way 16 Amps, one module complete all as specified and as directed. |
| 79 | Supply and fixingof socket modular type 6 amp/16 amps, 2/3 pin combined 02 Module complete all as specified and as directed. |
| 80 | Supply and fixing modular fan regulator stepped type 120W (2 module) complete all as specified and as directed. |
| 81 | S&F ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and as directed. |
| 82 | Material and labour for submain wiring with two single core2.50 sq mmPVC insulated FRLS multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit, medium gradeISI marked with all conduit fittings & fixing accessories and one single core 2.50 Sqmm FRLSmultistranded copper conductor cable as continuous earth wire complete all as specified and as directed. |
| 83 | Material and labour for submain wiring with two single core4.0 sq mmPVC insulated FRLS multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit, medium gradeISI marked with all conduit fittings & fixing accessories and one single core 4.0 Sqmm FRLSmultistranded copper conductor cable as continuous earth wire complete all as specified and as directed. |
| 84 | Material and labour for submain wiring with two single core6.0 sq mmPVC insulated FRLSH multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit, medium gradeISI marked with all conduit fittings & fixing accessories and one single core 6.0 Sqmm FRLSHmultistranded copper conductor cable as continuous earth wire complete all as specified and as directed. |
| 85 | Supply and fixing sheet metal enclosure for distribution board SPN (when MCBs to be used ) 8 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed. |
| 86 | Supply and fixing sheet metal enclosure for distribution board SPN (when MCBs to be used ) 4 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed. |
| 87 | Supply and fixing MCB, SPN, 32 Amp, 10 kA complete all as specified and as directed. |
| 88 | Supply and fixing of MCB, SP, 6-32A ,10 kA complete all as specified and as directed. |
| 89 | Supply and fixing of high efficient, energy saving, environmental friendly, long life, exclusive die-cast aluminium LED flood light withequipped with IP66 protection of 100 Watts complete with driver and connection with suitable size copper wire etc all as specified and directed. |
| 90 | Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1400 mm sweep. Minimum air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 91 | M&L for earthing complete for bldgwith galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm diaby means of nuts, bolts, thimbles, check nuts, washers of GI or steel,PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) with fair finish, internal surface of concrete chamber shall be given 15mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge, 8 mesh per liner inch, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) reinforced with XPM, jalli and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR Part-I (2009) and specified includingprovision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. |
| 92 | S&F in replacement indoor decorative LED battens integrated type 20 watt 4 feet white fixture with extruded aluminium body suitable for LED tube 20 watt, bipin holder, connector block, LED rod 20 watt etc complete with all accessories internally pre wired and including connecting up with twin corecopper conductor cable completeall as specified and as directed. |
| 93 | S&F LED luminaire 600mm x 600mm, 35/36 watt, 220 volt AC, recessed type with high effeiciency PMMA diffuser soft glare free light complete with driver, holder and LED lamp suitable for ceiling and connecting up with twin core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 94 | Supply and fixing in replacement sheet metal enclosure for distribution board SPN (when MCBs to be used) 12 way double door, 230 volts, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed. |
| 95 | Supply and fixing MCB, SPN, 40 Amp, 10 kA complete all as specified and as directed. |
| 96 | Supply and fixing sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 amps complete all as specified and as directed. |