| Sl. No. | Item Description |
| 1 | ScheduleA1- Civil works -Medical Block |
| 2 | 1. Dismantling the existing Nominal concrete 1:3:6 or richer mix including equivalent design mix to the required level, size and shapewherever required without damaging the nearby structures if any, and depositing the debris within a lead of 50m for retransportation and disposal all as per relevant specification and all as directed at site of work including all labour, tools, equipment, fuel, transport, etc., complete. |
| 3 | 2. Dismantling / cuttingthe existing RCCmembersat Ground floor including stacking the steel without disturbing near by structure and conveying and handing over the serviceable materials, if any, to the departmental stores and wherever requiredincluding collecting and depositing the Debris in Ground level with in a lead of 50m for disposal all as specified andas directed at site of work including all labour, tools, equipments, transport, fuel etc., complete. |
| 4 | 3. Dismantling and removing theexisting damaged brick work in cement mortar by manually/mechanical meanswherever requiredwithoutdamaging the nearby structures including collecting andbringing downdown the debris to the ground leveland depositing the debris within a lead of 50m for disposingall as specified andas directed at site, including all labour, tools, tackles, equipments, fuel, scaffolding, etc., complete. |
| 5 | 4. Dismantling and removing the existing IWC / EWCwith tank, W.C.Pan from Toilet without disturbing the existing structure near by including collecting and depositing the debris within a lead of 50m all as directedincluding all labour, tools, equipments, etc., complete. |
| 6 | 5. Removing the existing damaged wash hand basin with all accessories without disturbing the near by structure and handing over the serviceable materials, if any, to the department stores/ RSD and bringing downthe debris to the ground level and depositing with in a lead of 50mts for disposal, all as directed at site of work including all labour, tools, equipments, transport, fuel, etc., complete. |
| 7 | 6. Removing the existing damaged Urinal with all accessories without disturbing the near by structure and handing over the serviceable materials, if any, to the department stores and bringing down the debris to the ground level and depositing with in a lead of 50mts for disposal, all as directed at site of work including all labour, tools, equipments, transport, fuel, etc., complete. |
| 8 | 7. Dismantling AC sheet/Galvalume sheet roofing including ridges, hips, valleys and gutters etc., without disturbing near by structure and conveying and handing over the serviceable materials, if any, to the departmental stores and bringing downthe debris to the ground level for disposal and depositing with in a lead of 50mts for disposal, all as directed at site of work including all labour, tools, equipments, transport, fuel, etc., complete. |
| 9 | 8. Dismantling and removing the existing worn-out wooden/PVC doors etc., including frame with shutters in all floors without damaging the structures nearby, including transporting and handing over the same to departmental stores / RSO yard within a lead of 3km all as specified and as directed at site of work including all labour, tools, equipments, transport, fuel etc., complete.a). Area Less than 3 M2 |
| 10 | B). Area More than 3 M2 |
| 11 | 9. Dismantling and removing the existing worn-out wooden / Aluminium Windows / Ventilators etc., including frame with shutters in all floors without damaging the structures nearby, including transporting and handing over the same to departmental stores / RSO yard within a lead of 3km all as specified and as directed at site of work including all labour, tools, equipments, transport, fuel etc., complete.a). Area Less than 3 M2 |
| 12 | b). Area More than 3 M2 |
| 13 | c). Ventilators Area Less than 3 M2 |
| 14 | 10. Dismantling and removing the existing Gypsum board / hard board / thermocole false ceiling with frames, clamps etc., without damaging the adjoining structures, transporting and handing over the unserviceable materials to departmental stores/ RSD yard and bringing downthe debris to the ground level and depositing within a lead of 50m for disposal, all as directed including all labour, tools, equipment, scaffolding, transport, fuel, etc., complete. |
| 15 | 11. Dismantling and removing aluminium/ Gypsum / wooden partitionswherever required without damaging the near by structures including bringing downthe same to ground level, collecting and stacking the unwanted materials within a lead of 50m for disposal and handing over the retrived materials to RSD yard within a lead of 2kms allas specified and as directed at site of work including all labour, tools, equipments, transport, fuel, scaffolding etc., complete. |
| 16 | 12. Dismantling and removing the existing damaged floor plastering/floor tiles/mosaic/ Cuddappah stone in Cement Mortar to the required thickness wherever required without damaging the structures nearby, includingcollecting and bringing down the debris to the ground level and depositing within a lead of 50m for disposal, all as directed at site of work, including all labour, tools, equipments, transport, fuel, etc., complete |
| 17 | 13. Dismantling the existing wall tile dadooing including base mortar to the required thickness from the walls and wherever required to receive new finish including collecting and depositing the debris to the ground levelwithin a lead of 50m all as directed including all labour, tools, equipments,etc., complete. |
| 18 | 14. DismantlingtheexistingBrick jelly lime concrete in sunken portion of toilet area wherever required without damagingthenearbystructurestothe required level, size andshapeand makinggood the disturbed portions if any,includingcollecting and bringing downthe debris to the ground level and depositing within a lead of 50m for disposal, all as per relevant specification andas directed at site, including all labour, tools, equipment, transport, fuel, etc., complete. |
| 19 | 15. Preparing the surfaces of the sunken portion of toilet area wherever required and plastering with C.M 1:3 (1cement:3 CS sand) 20mm thick withIntegral water proofing liquid admixture conplast (or) equivalent(160ml /50kg of cement all as per relevant standards and specifications and all as directed at site of work including, curing, all materials,labour, tools, equipments, transport, fuel, etc., complete. |
| 20 | 16. Providing and laying brick jelly cement concrete in mix 1:5:10 (1 cement :5 CS sand :10 broken brick aggregate of 40mm nominal size ) in volumetric proportionsfor sunkenportions of the toilets to the required levels all as per relevant standards and specificationsincluding mixing, transporting, placing, consolidating, curing etc., all as directed including cement and all other materials, labour, tools, equipments, etc., complete. |
| 21 | 17. Providing and laying Ceramic glazed floor tiles of size 300 x 300 mm or nearest size (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Crushed stone sand), jointing with grey cement slurry @ 3.3 kg/ sq.m , complete and joints neatly pointed with white cement added with pigment to match the colour of the tiles, curing all as directed at site of work including cement and all other materials, labour, tools, equpiments, etc., complete. |
| 22 | 18. Chipping thoroughlythe existingdamagedplasteringfrom walls to receive new finish wherever required without damaging the nearby structures including conveying the debris to the ground level and depositing within a lead of 50m for disposal all as directed including all labour, tools, equipments, scaffolding etc., complete. |
| 23 | 19. Providing and fixing wall Dadooing using 1st quality ceramic glazed tilesof size 300mm x 200mm or of nearestsize as available in the market conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make and approved colour and shade set in cement mortar 1:3 (1cement: 3 fine CS sand), 12mm thick and joints neatly pointed with white cement added with pigment to match the colour of the tiles, curing all as directed at site of work including cement and all materials, labour, tools, equpiments, transport, fuel, etc., complete. |
| 24 | 20. Providing flooring with good quality Vitrified Tiles(Double Charge) of size 600mm x 600mm or of nearestsize as available in the market of 10 mm Nominal thickness set in cement mortar 1:4 (1 cement : 4 clean fine CS sand) 20 mm average thick with required slope fixed with neat cement slurry,and joints neatly pointed with white cement added with pigment to match the colour of the tiles,curing all as directed including cement and all other materials labour,tools, equipments , etc., complete |
| 25 | 21. Refilling with available excavated earth excluding boulders, rubbish, debris, etc., wherever required in layers not exceeding 200 mm thick and as directed at site, including consolidating the deposited earth in layer by watering and ramming including all labour, tools, equipment, etc., complete |
| 26 | 22. Providing and laying plain cement concrete of mix 1:4:8 (1cement :4 CS sand: 8 hard granite graded stone aggregate of 40mm nominal size) in volumetric proportion for levelling course wherever required including shuttering, mixing, transporting, placing, consolidation by ramming, curing etc., all as per relevant standards and specifications all as directed at site of work including cement, all materials, labour, tools, equipments, transport, fuel, etc., complete. |
| 27 | 23. a). Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.Three track three panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (98mm & above) x (40mm & above) & sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on two end panels along with multi-point locking system (Height upto 1.8 metre). |
| 28 | 23. b). Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work |
| 29 | 24. Providing Half brick work using bricks of class designation 50setin cement mortar 1:4 (1 Cement: 4 CS sand)in footh path, kitchen platform, partition in ground level upto fifth floor level and wherever necessary, all as directed at site of work, including scaffolding, labour, materials, Cement, tools, curing, etc., complete. |
| 30 | 25. Preparing the surfaces of walls and plastering in cement mortar 1:5 (1 cement : 5 CS sand), 12mm thick to the required finishwherever required all as directed at site of work, including cement and other materials, labour, tools, equipments, scaffolding, curing etc., complete. |
| 31 | 26. Providing and fixing granite slab of 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size of colour black, Cherry/Ruby red approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 CS sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels including all materials, labour, tools, equipments, curing etc., complete. |
| 32 | 27. Preparing the surfaces of old wooden members and applying two coats of synthatic enamelpaint (Asian / Nippon / Berger or equivalent)of approved brand and colour of good quality to give an even shadeall as directed at site of work including all labour, materials, tools, tackles, equipments, brushes, scaffolding, etc., complete. NOTE: 1. Necessary painting co-efficient shall be allowedas per Ch.P.A. engineering manual.2. The above quantity is inclusive of painting co-efficient. |
| 33 | 28. Providing and fixing SFRC (Steel Fiber Reinforced Concrete) Manhole cover with frame of size600 x 600 mm for Manhole and wherever required in mix 1:1.5:3 ( 1 cement : 1.5 C.S.sand: 3 hard granite graded stone aggregate of 20mm nominal size) in volumetric proportions to the required size, all as per relevant specifications, drawings and as directed includingnecessary form work, mixing, transporting, placing, compacting, curing, finishing the exposed concrete surface withneat cement punning at 2.2 kg/Sq.m as directed, includingremoving the existing damaged manhole cover, lifting, handling, transporting and placing the cover over the frame in correct position and alignment, providing necessary lifting holes including all materials, labour, tools, plants, equipments, fuel, etc., complete. |
| 34 | 29. Dismantling of Gully trap including chamber wherever required without damaging the structures nearby and collecting, stacking the debris within a lead of 50m for disposal all as directed at site of work including costs of all labour, tools, equipments, etc., complete. |
| 35 | 30. Providing and fixing Gully trap including constrcution of Chamber of size 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 CS sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 CS sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 crushed stone sand) 12mm thick, finished with a floating coat of neat cement all as directed at site of work including all labour, materials, tools, tackles, equipments, brushes, etc., complete. |
| 36 | 31. Earth work excavation upto 1.50m in ordinary soil, sand, clay mixed with roots, boulders weighing individually less thasn 250kg debris, rubbish etc., as existing at site of work for all foundations and other such works as directed including dressing of sides ramming of bottom all as per relevant specification and as directed at site, depositing the excavated earth within a lead of 50m for transportation including shoring, strutting, all labour, tools, tackles, equipments, fuel, etc., complete. |
| 37 | 32.Providing and laying reinforced cement concrete of mix 1:1.5:3 (1 cement:1.5 CS sand:3 hard graded stone aggregate of 20mm nominal size) in volumetric proportions for Drain Side Walls and wherever required all as per relevant specification and as directed at site of work including cement, mixing, transporting, placing, vibrating,ramming, consolidating, curing, shuttering, all materials, labour, tools, plants, equipments, fuel, etc., complete. |
| 38 | 33. Casting, transporting and placing RCCpre cast cover slabs 100 mm thick in mix 1:1.5:3 (1 cement : 1.5 CS sand : 3 hard granite stone graded aggregate of 20mm nominal size) in volumetric proportion including formwork, mixing, transporting, placing, consolidating, etc., including finishing the exposed surfaces with a floating coat of neat cement punning 2.2kg/sqm and as directed including necessary curing, handling, placing and fixing in position and all other materials, labour, tools, equipments etc., complete.Note: Supplying and fabrication of steel reinforcement will be measured and paid seprately under the relevant item. |
| 39 | 34. Supplying, fabricating and placing in positionHYSD (Fe 500/ 550 grade) TMT steel bars as reinforcement for all RCC works wherever required, including handling, cutting, bending and tying with 1.25mm dia black annealed steel binding wire including placing, all as per relevant specification, drawings and as directed,including all materials, labour, tools, equipment, transport, fuel, etc., complete.Note: 1.The rate shall be inclusive of cost of reinforcement steel, binding wire and fabrication charges etc., complete. Binding wire will not be measured for payment purpose. |
| 40 | 35. Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). |
| 41 | 36. Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge and as directed at site of work including transporting, placing, all materials, labour, tools, plants, equipments, fuel, etc., complete.(Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 42 | 37. Providing and fixing IS : 12817 marked stainless steel fittings (heavy weight) with stainless steel screws for doors, etc., as directed at site of work with the approval of engineer in charge, including all materials, labour, tools, equipments, etc. completea) Butt Hinges 125mm |
| 43 | b) Tower bolt 150 mm |
| 44 | c) Tower bolt 75mm |
| 45 | d) Aldrop 250mm |
| 46 | e) 125mm Handle |
| 47 | 38. Preparing the surfaces of existing ceiling etc., and applying onecoatofwhite washing with premium acrylic emulsion paint of interior grade, (Asian / Nippon / Berger or equivalent) having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour all as directed at site of work including all labour, scaffolding, materials, tools, equipments, brushes, safety ladder, safetybelts, safety helmets, etc.,complete. |
| 48 | 39. Preparing the surfaces of existing interior walls etc., and applyingtwocoatsofColour washing with premium acrylic emulsion paint of interior grade, (Asian / Nippon / Berger or equivalent) having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including one coat of interior primer wherever required to achieve even shade and colour all as directed at site of work including all labour, scaffolding, materials, tools, equipments, brushes, safety ladder, safetybelts, safety helmets, etc.,complete. |
| 49 | 40. Providing and fixing White vitreous china Orissa pattern W.C pan of size 580x 440 mm with integral type foot rest squatting pan (Indian Type WC Pan) Parryware/Hindware/ jaquar or equivalent with 100 mm sand cast iron P or S trap, 10 litre low level white PVC flushing cistern, incluing flush pipe, with manually controlled device (Handle lever) conforming to IS :7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required, all as directed at site of work including all materials, labour, tools, equipments, etc., complete. |
| 50 | 41. Providing and fixing white vitreous china pedastal type water closet ( European type W.C pan) Parryware/Hindware/ jaquar or equivalent with seat and lid , 10 litre low level white PVC flushing cistern, including flush pipe, with manually controlled device(Hnadle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required, all as directed at site of work including all materials, labour, tools, equipments, etc., complete. |
| 51 | 42. Providing and fixing good quality vitreous white wash hand basin ofsize 550x 400 mm or nearest size as available in the market ( Parryware/Hindware/ jaquar or equivalent) with single 15mm C.P brass pillar tap. CP waste fitting , 32mm dia cp brass union, 15 mm dia PVCinlet connection, 32mm dia pvc waste pipe fittings, a pair of cast iron brackets etc as available in the market suitable for fixing the wash hand basin, including painting the brackets etc with two coats of syntheticenamel paint over one coat of primer fixing the brackets with teak wood plugand making good the disturbed portion, etc., all in sound working condition all as per relevant specification and as directed including all materials, labour, tools,equipments,etc., complete. |
| 52 | 43. Providing and fixing white vitreous china flat back type lipped front urinal basin of 430x260x350 mm sizes or asavailable in the market (Parryware/Hindware/ jaquar or equivalent) as per manufacturers specification with PVC flexible flush pipe with clamp, teakwood plugs, screws with all fittings and fixtures for inlet and outlet arrangements etc., all as per relevant secification and as directed at site in sound working condition, including all materials, labour, tools, equipment, etc., complete. |
| 53 | 44. Dismantling and Removing the existing damaged PVC / Cast Iron / GI pipes with all accessories, wherever required without damaging near by structuresincluding collecting and stacking the dismantled pipes within a lead of 50m for disposal , transporting and handing over the unserviceable materials to departmental stores/ RSD yard all as specified and as directed at site of work including all labour, tools, tackles, equipments, scaffolding, transport, fuel, safety ladder, safety belts, safety helmets, safety netsetc., complete. |
| 54 | 45. Removing the existing damaged taps, wall mixture, shower arm with shower rose, Health facuet, angle cock etc.,with all accessories without disturbing near by structure and conveying and handing over the serviceable materials, if any, to the department stores, all as directed at site of work including all labour, tools, equipments, transport, fuel, etc., complete. |
| 55 | 46. Supplying and fixingChlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply (Varun / Finolex / Trubore or equivalent) for external / internal works exposed on wall with CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing with all required accessories like tees, bends, couplings, elbows, reducers, unions, etc.,jointing of pipes & fittings with one step CPVC solvent cement and testing of joints andincluding punching the masonry/concrete wherever required and making good the disturbed portions, all as per relevant specification and directed at site of work,labour, tools, equipments, scaffolding etc., completea) 32 mm dia. |
| 56 | 46.b) 25mm dia. |
| 57 | 46.c) 20mm dia. |
| 58 | 46.Providing and fixing First quality Gun metal gate valve (Full way valve with Handle) of following sizesto the water pipe lines in all floors in sound working condition by removing the existing wheel valve including making the joints water tight and testing etc., all as directed at site of work including all materials, labour, tools, equipments, etc., complete.(d). 32mm dia. |
| 59 | 46.(e) 25 mm dia. |
| 60 | 47. Providing, fixing and laying of pipes on floors of, approved quality rigid PVC pipes of 75/110mm outside diameters 6 Kgf/sq.cm pressure-(Finolex (or) Trubore (or) Varun (or) Supreme or equivalent) for waste water lines/sewage lines including necessary specials like bends, tees, elbows, clamps and specials, etc., wherever required, including joining the pipes using necessary adhesives, and making connections to floor traps, gully traps manholes etc., including cutting the floor concrete masonry and making good the disturbed portions all as directed at site of work including all materials, labour, tools, equipments, scaffolding, cement etc., complete.a). 110mm Dia |
| 61 | b). 75mm Dia |
| 62 | 48. Providing and fixing 110mm dia PVC Nahani trap (floor trap with gratings suitable for PVC drainage pipe) embedding the trap making the joints water tight etc., allas directed including allmaterials, labour, tools, equipments etc., complete. |
| 63 | 49. Supplying and fixing the sanitary fittings with First qualityC.P fittings (Parryware/Hindware/ jaquar /Metro or equivalent) intoilets in sound working condition including testing etc., all as directed at site of work including all materials, labour, tools, equipments, etc., complete.a) Health Faucet |
| 64 | b) Short body Tap 15mm dia conforming to IS:8931 |
| 65 | c) Stop cock 15mm dia (concealed) conforming to IS:8931 |
| 66 | d) 32mm size PTMT Bottle Trap |
| 67 | e) Angle valve 15mm dia |
| 68 | f) Long body Tap(Bib Cock) 15mm |
| 69 | 50. Loading, transporting, dumping and leveling the surplus earth and debris etc., within a lead of 3 kms outsidethe Port premises all as per relevant specifications and as directed including all labour, transport, tools, equipments, fuel, etc., complete.Note:1.The tenderer shall maintain trip sheets in triplicate in Trust\"s approved format at his own cost.2.Payment will be based on the lorry cubical content. No deduction of voids for debris will be made. 4. 20%deduction of voids for surplus earthwill be made. However the final quantity will be restricted to actual quantity of debris dismantling /demolishing items.(a) Surplus Earth |
| 70 | (b) Debris |
| 71 | 51. Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen, including removing the scaffolding with platform after completion of works all as directed at site of work including all labour materials tools equipmentstransport fuel etc complete.. The elevational area of the scaffolding shall be measured for payment purpose.Note (1) 75% of payment may be relaeased after erecting of scaffolding in all respect.(2) The balance 25% ofpayment may be released after completion of improvement works and removal of scaffolding |
| 72 | 52. Supplying diluting and injecting chemical emulsion for post constructional anti termite treatment with chlorpyrlphos Emulsifiable concentrate with 1% concentration (i.e. one litre of chemical for every 20 litires of emulsion) in soil along internal andexternal wall using chemical emulsion at 2.25 litire per linear metre inlcuding drilling and plugging holes etc. and treating the soil under floors, masonry / concrete inside and outside of buildings wherever required, using chemical emulsion at 1 litre per hole at 30cm interval including drilling 12mm dia holes and plugging them with cement mortar 1:2 to the full depth of the hole and treating the points of contact of wood work by chemical emulsion (in oil of kerosene based solution) at 0.5 litres per hole by drilling 6mm dia at downward angle of 45 degree at 150mm c/c and sealing the same and as directed including all material (including cement) labour, tools, scaffolding, ladder, equipments etc. complete |
| 73 | 53. Supplying, fabricating and fixing the M.S gate, window / Ventilator grill, Ladder as per existing or as directed at site using structrual steel, etc., using as verticles, horizontals and diagonal members, including fixing including cutting the flats, bars, etc., to the reqired length, welding the joints all as directed at site of work , providing scaffolding, fixingin proper alignment, all as directed at site of work including applying a priming coat of approved steel primer all materials, labour, tools, transport, equipments, fuel, etc., complete.Note:1. The payment is based on the total weight of the MS flats, bars, etc., as fabricated. 2. The weighment will made at site or any other place as approved by the engineer-in-charge. Necessary charges for transport, weighment. etc., will be borne by the contractor. |
| 74 | Schedule- A2 Civil Works -Surgical Block |
| 75 | 1.Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen, including removing the scaffolding with platform after completion of works all as directed at site of work including all labour materials tools equipmentstransport fuel etc complete.. The elevational area of the scaffolding shall be measured for payment purpose.Note (1) 75% of payment may be relaeased after erecting of scaffolding in all respect.(2) The balance 25% ofpayment may be released after completion of improvement works and removal of scaffolding |
| 76 | 2. Dismantling and removing the existing damaged floor plastering/floor tiles/mosaic/ Cuddappah stone in Cement Mortar to the required thick wherever required without damaging the structure nearby, includingcollecting and bringing downthe debris to the ground level and depositing within a lead of 50m for disposal, all as directed at site of work, including all labour, tools, equipments, transport, fuel, etc., complete |
| 77 | 3. Dismantlingand removing the existing wall plastering / tile dadoing including base mortar to the required thick from the walls wherever required to receive new finish including collecting and depositing the debris to the ground levelwithin a lead of 50m all as directed including all labour, tools, equipments, transport, fuel,etc., complete. |
| 78 | 4. Dismantling and removing the existing worn-out wooden/ PVC doors/ windows/ ventilators etc., including frame with shutters in all floors without damaging the structures nearby, including transporting and handing over the same to departmental stores / RSO yard within a lead of 3km all as specified and as directed at site of work including all labour, tools, equipments, transport, fuel etc., complete.a). Area Less than 3 M2 |
| 79 | b). Area More than 3 M2 |
| 80 | c).Dismantling and removing the existing wornout wooden/Aluminium partition etc., including frame with shutters and handing over the same to departmental stores/RSD yard within a lead of 3km, without damaging the adjoining structures, and bringing downthe debris to the ground level and depositing within a lead of 50m for disposal, all as directed including all labour, tools, equipment, scaffolding, transport, fuel, etc., complete. |
| 81 | 5. Dismantling and removing the existing Gypsum board / thermocole false ceiling with frames, clamps etc., without damaging the adjoining structures, transporting and handing over the unserviceable materials to departmental stores/ RSD yard and bringing downthe debris to the ground level and depositing within a lead of 50m for disposal, all as directed including all labour, tools, equipment, scaffolding, transport, fuel, etc., complete. |
| 82 | 6. Dismantling and Removing the existing damaged PVC / Cast Iron / GI pipes with all accessories, wherever required without damaging near by structures and handing over the unserviceable materials to departmental stores / RSD yardincluding collecting and stacking the dismantled pipes within a lead of 50m for disposal all as specified and as directed at site of work including all labour, tools, tackles, equipments, scaffolding, transport, fuel, safety ladder, safety belts, safety helmets, safety netsetc., complete. |
| 83 | 7. Dismantling and removing the existing IWC / EWC with floor concrete from Toiletwithout disturbing the existing structure near by including collecting and depositing the debris within a lead of 50m all as directedincluding all labour, tools, equipments, etc., complete. |
| 84 | 8. Removing the existing damaged Urinal with all accessories without disturbing near by structureand bringing down the debris to the ground level and depositing with in a lead of 50mts for disposal, all as directed at site of work including all labour, tools, equipments, transport, fuel, etc., complete. |
| 85 | 9. Removing the existing damaged wash hand basin with all accessories without disturbing near by structure and conveying and handing over the serviceable materials, if any, to the department stores/ RSD yardand bringing down the debris to the ground level and depositing with in a lead of 50mts for disposal, all as directed at site of work including all labour, tools, equipments, transport, fuel, etc., complete. |
| 86 | 10. Dismantling / cuttingthe existing RCCmembers at all floors including stacking the steel without disturbing near by structure and conveying and handing over the serviceable materials, if any, to the department stores and wherever requiredincluding collecting and depositing the Debris in Ground level with in a lead of 50m for disposal all as specified andas directed at site of work including all labour, tools, equipments, transport, fuel etc., complete. |
| 87 | 11. Dismantling the existing Plain cement concrete in Rich mix to the required level, size and shape wherever required without damaging the nearby structures if any, and depositing the debris within a lead of 50m for retransportation and disposal all as per relevant specification and all as directed at site of work including all labour, tools, equipment, fuel, transport, etc., complete. |
| 88 | 12. Dismantling the existing Plain cement concrete in lean mix to the required level, size and shape wherever required without damaging the nearby structures if any, and depositing the debris within a lead of 50m for retransportation and disposal all as per relevant specification and all as directed at site of work including all labour, tools, equipment, fuel, transport, etc., complete. |
| 89 | 13. Dismantling and removing theexisting damaged brick work in cement mortar by manually/mechanicallywherever requiredwithout damaging the nearby structures including collecting and bringing down the debris to the ground leveland depositing the debris within a lead of 50m for disposingall as specified andas directed at site, including all labour, tools, tackles, equipments, fuel, scaffolding, etc., complete. |
| 90 | 14. Dismantling and removing the existing wornout MS grill, MS gates, window grill, ventilators grill etc without damaging the structures nearby, including transporting and handing over the same to departmental stores / RSO yard within a lead of 3km all as specified and as directed at site of work including all labour, tools, equipments, transport, fuel etc., complete. |
| 91 | 15. DismantlingtheexistingBrick jelly lime concrete / Cement Concrete in sunken portion of toilet area wherever required without damagingthenearbystructurestothe required level, size andshapeand makinggood the disturbed portions if any,includingcollecting and bringing downthe debris to the ground level and depositing within a lead of 50m for disposal, all as per relevant specification andas directed at site, including all labour, tools, equipment, transport, fuel, etc., complete. |
| 92 | 16. Removing the existing damaged taps, wall mixture, shower arm withrose, Health facuet, angle cock, towel rod, etc.,with all accessories without disturbing near by structure and conveying and handing over the serviceable materials, if any, to the department stores /RSD, all as directed at site of work including all labour, tools, equipments, transport, fuel, etc., complete. |
| 93 | 17. Earth work excavation in ordinary soil, sand, clay mixed with roots, boulders weighing individually less than 250kg debris, rubbish etc., as existing at site of work for all foundations and other such works up to 1.50m depth including dressing of sides ramming of bottom all as per relevant specification and as directed at site, depositing the excavated earth within a lead of 50m for transportation including shoring, strutting, all labour, tools, tackles, equipments, fuel, etc., complete. |
| 94 | 18. Refilling with available excavated earth excluding boulders, rubbish, debris, etc., wherever required in layers not exceeding 200 mm thick and as directed at site, including consolidating the deposited earth in layer by watering and ramming including all labour, tools, equipment, etc., complete |
| 95 | 19. Providing and laying plain cement concrete of mix 1:4:8 (1cement :4 Crushed stone sand: 8 hard granite graded stone aggregate of 40mm nominal size) in volumetric proportion for levelling course wherever required including shuttering, mixing, transporting, placing, consolidation by ramming, curing etc., all as directed at site of work includingcost of cement, all materials, labour, tools, equipments, transport, fuel, etc., complete. |
| 96 | 20. Providing Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:5 (1 cement : 5 CS sand) for raising walls in all floors upto fifth floor level and wherever required, all as per the details and as specified in the relevantschedule and as directed at site of work including scaffolding,curing, cement, all other materials, labour, tools, equipments, transport, fuel, etc., complete. |
| 97 | 21. Providing Half brick work with common burnt clay (non-modular) bricks of class designation 7.5setin cement mortar 1:4 (1 Cement: 4 CS sand)in toilet / bathroom / partition in ground level upto fifth floor level and wherever necessary, all as directed at site of work, including scaffolding, labour, materials, Cement, tools, curing, etc., complete. |
| 98 | 22. Providing Brick pillasterwith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V levelin CM 1:4 (1 cement : 4 CS sand) wherever required, all as directed at site of work including cost of cement , all materials, labour, tools, equipments, scaffolding, curing, transport, fuel, etc., complete |
| 99 | 23. Casting, transporting and placing RCC pre cast cover slabs of various thickness more than 40 mm thick in mix 1:1.5:3 (1 cement : 1.5 CS sand : 3 hard granite stone graded aggregate of 20mm nominal size) in volumetric proportion including formwork, mixing, transporting, placing, consolidating, etc., including finishing the exposed surfacesand as directed including necessary form work, curing, handling, placing and fixing in position with CM 1:3(one cement : three fine CS sand) including cost of cement and all other materials, labour, tools, equipments etc., complete.Note: Supplying and fabrication of steel reinforcement will be measured and paid seprately under the relevant item. |
| 100 | 24. Providing and laying plain cement concrete of mix 1:1.5:3 (1 cement:1.5 CS sand:3 hard graded stone aggregate of 20mm nominal size) in volumetric proportions wherever required all as per relevant specification and as directed at site of work including mixing, transporting, placing, vibrating, ramming, consolidating, curing, shuttering, including cost ofcement all materials, labour, tools, plants, equipments, fuel, etc., complete. |
| 101 | 25. Providing and laying plain cement concrete of mix 1:2:4 (1 cement: 2 CS sand:4 hard graded stone aggregate of 20mm nominal size) in volumetric proportions wherever required all as per relevant specification and as directed at site of work including mixing, transporting, placing, vibrating, ramming, consolidating, curing, shuttering,including cost of cement, all materials, labour, tools, plants, equipments, fuel, etc., complete. |
| 102 | 26. Supplying, fabricating and placing in positionHYSD (Fe 500/ 550 grade) TMT steel bars as reinforcement for all RCC works wherever required, including handling, cutting, bending and tying with 1.25mm dia black annealed steel binding wire including placing, all as per relevant specification, drawings and as directed,including all materials, labour, tools, equipment, transport, fuel, etc., complete.Note: (i) The rate shall be inclusive of cost of reinforcement steel, binding wire and fabrication charges etc., complete. Binding wire will not be measured for payment purpose. |
| 103 | 27. Supplying, fabricating and fixing the M.S gate, window / Ventilator grill, Ladder, etc.,as per existing or as directed at site using suitable MS Square bars, MS Square sections, MS Flats, M.S.sheet, etc., using as verticles, horizontals and diagonal members,including cutting the flats, bars, etc., to the reqired length, welding the joints all as directed at site of workproviding scaffolding, fixing gate in proper alignment including applying one coat of red oxide primer all as directed at site of work including all materials, labour, tools, transport, equipments, fuel, etc., complete.Note:1. The payment is based on the total weight of the MS flats, bars, etc., as fabricated. 2. The weighment will made at site or any other place as approved by the engineer-in-charge. Necessary charges for transport, weighment. etc., will be borne by the contractor. |
| 104 | 28. Preparing the surfaces of the floor area wherever required and plastering with C.M 1:3 (1cement:3 fine CS sand) 20mm thickall as per relevant specifications and all as directed at site of work including, curing, cost of cement, all materials,labour, tools, equipments, transport, fuel, etc., complete. |
| 105 | 29. Preparing the surfaces of the floor area wherever required and plastering with C.M 1:3 (1cement:3 fine CS sand) 20mm thick with water proofing compoundof integral water proofing liquid admixture conplast ( 160ml / 50kg of cement) all as per relevant specifications and all as directed at site of work including, curing, cost of cement, all materials,labour, tools, equipments, transport, fuel, etc., complete. |
| 106 | 30. Preparing the surfaces of walls and plastering in cement mortar 1:5 (1 cement : 5 fine CS sand), 12mm thick to the required finish all as directed at site of work, including cost ofcement and other materials, labour, tools, equipments, scaffolding, curing etc., complete. |
| 107 | 31. Preparing the surfaces of ceilingand plastering in cement mortar 1:3 (1cement : 3 clean fine CS sand) 6 - 10 mm thick to the required finish, all as directed at site of work including alllabour, cement, materials, tools, equipments, scaffolding, curing, etc. complete. |
| 108 | 32. Providing and laying Ceramic glazed floor tiles of size 300 x 300 mm or nearest size (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 CS sand), jointing with grey cement slurry @ 3.3 kg/ sq.m , complete and joints neatly pointed with white cement added with pigment to match the colour of the tiles, curing all as directed at site of work including cement and all other materials, labour, tools, equpiments, etc., complete. |
| 109 | 33. Providing and laying Ceramic glazed wall dadooing / skirtingwith tiles conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 12 mm thick bed of cement mortar 1:3 (1 Cement : 3 CS sand), and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade,all as directed at site of work including all materials, labour, tools, equpiments, scaffolding, curing, etc., complete. |
| 110 | 34. Providing and layingVitrified Tile flooring(Double Charge) of size 600mm x 600mm or nearestsize with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 CS sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and pigments to match the colour of the tiles, all as directed including cost of cement and all other materials, labour,tools, equipments, curing etc., complete |
| 111 | 35. Providing and fixing granite slab of 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for cupboard, shelves, racks and similar locations of required size of colour black, Cherry/Ruby red approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 CS sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges, etc. complete at all levels including all materials, labour, tools, equipments, curing etc., complete. |
| 112 | 36. Providing edge moulding to 18 mm thick granite stone for cupboard, shelves, racks and similar locations etc., including machine polishing to edge, etc., all as directed at site of work including all materials, labour, tools, equipments, curing etc., complete. |
| 113 | 37. Providing and fixingsal/padak wood frame for doors / windows / ventilators with necessary M.S. hold fasts / clamps of size 40x5x400mm longfixed suitably to the masonry / concrete including cutting pockets and grouting with plain cement concrete 1:3:6 (1 cement : 3 CS sand : 6 hard granite graded stone aggregate of 20mm nominal size) in volumetric proportions, curing including oil type wood preservative of approved brand and manufacture on the portions of the timber abutting against masonry / concrete all as directed at site of work including cement and all other materials, labour, tools, scaffolding equipment, etc., complete. |
| 114 | 38. Providing and fixing Second class teak wood shutterframe with wood panelleing /glazed shutters 30mm thick for doors, windows / cupboard etc., including top rail, bottom rail, lock rail etc., all as per relevant specifications as directed at site of work including all materials, labour, tools, equipments, transport, fuel etc., complete. Note:Necessary fixtures like butt hinges, Aldrop and tower bolts, etc., will be paid under relevant item of BOQ |
| 115 | 39. Providing and fixing sal/Padak wood for Cup-board Main frame and shutter including coach screwsincluding applying one coat of coal tar paint on the portions of the timber abutting against masonry / concrete all as directed at site of work including all materials, labour, tools, equipment, etc., complete. |
| 116 | 40. Providing and fixing of colour anodized aluminium main frame for doors and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia. and size, including necessary filling up the gaps at junctions, i.e., at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically (anodised transparent or dyed to required shade according to IS: 1868,Minimum anodic coating of grade AC 15) wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all as per relevant specifications as directed at site of work including all materials, labour, tools, equipments, transport, fuel etc., complete. |
| 117 | 41. Providing and fixing colour anodized aluminium sections for Shutter frames of doors and partitions with extruded built up standard tubular and other sections of approved make (INDAL or JINDAL or Equivalent make) with clear anodized aluminium coating (minimum anodized coating of Grade AC 15) conforming to IS 1868 including supplying and fixing necessary accessories like anodised aluminium cleat angles, snap on beadings (clips) for glazing / panelling, C.P. brass screws, anodised aluminium push plates 100mm wide both sides fixed with G.I. Bolts and nuts including necessary metal screws and concealed locking arrangements with woollen felt, filling the hollows of frames with wooden inserts of required length of approved quality wherever required to facilitate fixing of fittings all as shown in the drawing and as directed including all materials, labour, tools, equipments etc., complete. |
| 118 | 42. Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo withIS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. all as directed including all materials, labour, tools, equipments etc., complete. |
| 119 | 43. Providingand fixing Prelaminated flat pressed three layer or graded wood particle board with both sides decorative lamination, (medium density) Grade I, Type II conforming and marked to IS : 12823 (exterior grade) 12 mm thick fordoors / partitions all as directed including all materials, labour, tools, equipments,transport,etc., complete. |
| 120 | 44. a). Supplying and fixing in position 5.5 mm thick plain glass (saint Gobain or Modiguard or equivalent) for doors / windows / partitions with necessary accessories like wooden beading/ Rubber beading, screw etc., all as directed at site including removing the old damaged glass, all materials, labour, tools, equipments, transport, fuel, etc., complete.Note: The actual area of glass used alone measured for payment purpose. |
| 121 | 44. b). Supplying and fixing in position 4 mm thick Frosted glass sheet (saint Gobain or Modiguard or equivalent) (weight not lessthan 10kg/sqm) for doors / windows / partitions with necessary accessories like wooden beading/ Rubber beading, screw etc., all as directed at site including removing the old damaged glass, all materials, labour, tools, equipments, transport, fuel, etc., complete.Note: The actual area of glass used alone measured for payment purpose. |
| 122 | 45. Providing and laying brick jelly cement concrete in mix 1:5:10 (1 cement :5 CS sand :10 broken brick aggregate of 40mm nominal size ) in volumetric proportionsfor sunkenportion of the toilet to the required thicknessincluding mixing, transporting, placing, consolidating, curing etc., all as directed including cement and all other materials, labour, tools, equipments, etc., complete. |
| 123 | 46. Providing and fixing white vitreous china pedastal type water closet ( European type W.C pan) with seat and lid, 10 litre low level white PVC flushing cistern, including flush pipe, with manually controlled device(Handle lever) conforming to IS : 7231, with all fittings and fixtures complete,in sound working condition, including cutting and making good the walls and floors wherever required, all as directed at site of work including all materials, labour, tools, equipments, etc., complete. |
| 124 | 47. Providing and fixing White vitreous china Orissa pattern W.C pan of size 580x 440 mm with integral type foot rest squatting pan (Indian Type WC Pan) with 100 mm sand cast iron P or S trap, 10 litre low level white PVC flushing cistern, incluing flush pipe, with manually controlled device (Handle lever) conforming to IS :7231, with all fittings and fixtures complete, in sound working condition, including cutting and making good the walls and floors wherever required, all as directed at site of work including all materials, labour, tools, equipments, etc., complete. |
| 125 | 48. Providing and fixing white vitreous china flat back type lipped front urinal basin of 430x260x350 mm sizesavailable in the market as per manufacturers specification with PVC flexible flush pipe with clamp, teakwood plugs, screws with necessary fittings and fixtures for inlet and outlet arrangements etc., all as per relevant secification and as directed at site in sound working condition, including all materials, labour, tools, equipment, etc., complete. |
| 126 | 49. a). Providing and fixing good quality vitreous white wash hand basin ofsize 550x 400 mm or nearest size as available in the market ( parrywareor equivalent) with single 15mm C.P brass pillar tap. CP waste fitting , 32mm dia cp brass union, 15 mm dia PVCinlet connection, 32mm dia pvc waste pipe fittings, a pair of cast iron brackets etc as available in the market suitable for fixing the wash hand basin, including painting the brackets etc with two coats of syntheticenamel paint over one coat of primer fixing the brackets with teak wood plugand making good the disturbed portion, etc., all in sound working condition all as per relevant specification and as directed including all materials, labour, tools,equipments,etc., complete. |
| 127 | 49. b). Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings suitable for the wash hand basin, including teak wood plug and necessary screwsand making good the disturbed portion, etc., all in sound working condition all as per relevant specification and as directed including all materials, labour, tools,equipments,etc., complete. |
| 128 | 49. c). Providing and fixing white vitreous china laboratory sink of Size 600x450x200 mm wherever required with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, including cutting and making good the wall all in sound working condition all as per relevant specification and as directed including all materials, labour, tools, equipments, etc., complete. |
| 129 | 49. d). Providing and fixing white glazed fire clay Drain Board of size 600 x 450 x 25mm wherever requiredwith proper aligment /slope to drain the water including C.I. brackets, painting of brackets, cutting and making good the walls all in sound working condition all as per relevant specification and as directed including all materials, labour, tools, equipments, etc., complete. |
| 130 | 50. Providing and fixing 110mm dia PVC Nahani trap (floor trap with gratings suitable for PVC drainage pipe) embedding the trap making the joints water tight etc., allas directed including allmaterials, labour, tools, equipments etc., complete. |
| 131 | 51. Providing andfixing PVC gully trap with constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 CS sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 crushed stone sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 CS sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 crushed stone sand) 12mm thick, finished with a floating coat of neat cement punning @3.3kg/Sqm all as per relevant specification and as directed including cost of cement,all materials, labour, tools, equipments, etc., complete. |
| 132 | 52. Supplying and fixingChlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply (Trubore / Finolex or equivalent) for internal works exposed on wall with CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing with all required accessories like tees, bends, couplings, elbows, reducers, unions, etc.,jointing of pipes & fittings with one step CPVC solvent cement and testing of joints andincluding punching the masonry/concrete wherever required and making good the disturbed portions, all as per relevant specification and directed at site of work, including cost of cement and all materials, labour, tools, equipments, scaffolding etc., completea) 32 mm dia |
| 133 | b) 25mm dia |
| 134 | c) 20mm dia |
| 135 | 53. Supplying and fixingChlorinated Polyvinyl Chloride (CPVC) pipes of 20 mm dia, having thermal stability for hot & cold water supply (Trubore / Finolex or equivalent) for concealed works with CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing with all required accessories like tees, bends, couplings, elbows, reducers, unions, etc.,jointing of pipes & fittings with one step CPVC solvent cement and testing of joints andincluding punching the masonry/concrete wherever required and making good the disturbed portions, all as per relevant specification and directed at site of work,including cost of cement and all labour, tools, equipments, scaffolding etc., completeNote: Necessary Cutting of Brick work, Concrete, Plastering, etc., will be paid under relevant items of BOQ |
| 136 | 54. Providing, fixing and laying of pipes on floors of, approved quality rigid PVC pipes of 50/75/110mm outside diameters 6 Kgf/sq.cm &4Kgf/sq.cmpressure-(Finolex (or) Trubore (or) Varun (or) Supreme or equivalent) for waste water lines/sewage lines / rain water down fall pipe including necessary specials like bends, tees, elbows, clamps and specials, etc., wherever required, including joining the pipes using necessary adhesives, and making connections to floor traps, gully traps manholes etc., including cutting the floor concrete masonry and making good the disturbed portions all as directed at site of work including all materials, labour, tools, equipments, scaffolding, cement etc., complete.a). 50 mm Dia (6 Kgf/sq.cm) |
| 137 | b). 75mm Dia (6 Kgf/sq.cm) |
| 138 | c). 110 mm Dia (4 Kgf/sq.cm) |
| 139 | d). 110 mm Dia (6 Kgf/sq.cm) |
| 140 | 55. Supplying and fixing the sanitary fittings with First quality (Parryware/Hindware/ jaquar /Metro or equivalent) C.P Brass / PTMT/ PVC/ SS fittings intoilets in sound working condition including testing etc., all as directed at site of work including all materials, labour, tools, equipments, etc., complete.a). PTMT 600mm Long Towel Rail |
| 141 | b). C.P Brass Health faucet 15mm dia. With 1.2M length hose |
| 142 | c). C.P Brass Pillar cock 15mm dia |
| 143 | d).C.P Brass Short body tap 15mm dia |
| 144 | e).C.P Brass Stop cock 15mm dia (Concealed) |
| 145 | f). C.P Brass Angle valve 15mm |
| 146 | g).C.P Brass Long body Bib cock 15mm |
| 147 | h). C.P Brass Extension nipple of size:15mmx50mm |
| 148 | i). C.P Brass Shower arm with flange 12\" length |
| 149 | j).C.P Brass Shower rose |
| 150 | k). C.P Brass 15mm dia. Single lever Wall mixer with telephonic shower |
| 151 | l). PTMT 32mm bottle trap- PTMT |
| 152 | m). PVC connectionfor wash basin and flush tank -600mm length |
| 153 | n). PVC connection for Kohinoor Brand with Nylon thread Hot water line |
| 154 | 0). Stainless Steel Grating 100mm dia |
| 155 | 56. Supplying and fixing on wallBevelled edge face mirror (saint Gobain or equivalent) of size 610x450mm(approx) with PVC frames and plywood back all as directed at site of work including all materials, labour, tools, equipments, etc., complete. |
| 156 | 57. Supplying and fixing of Anodized Aluminium fittings for doors, cup-boards, etc., (anodised transparent or dyed to required shade according to IS: 1868,Minimum anodic coating of grade AC 15) with necessary screws, all as directed at site of work including all materials, labour, tools, equipments, etc. completea). Tower bolt (barrel type) 200x10 mm |
| 157 | b). Tower bolt (barrel type) 100x10 mm |
| 158 | c). Tower bolt (barrel type) 75x10 mm |
| 159 | d). Hook and eye 250mm |
| 160 | e). Door handle100mm long with plate 150x32mm |
| 161 | f). Butt hinges 125mmlong |
| 162 | g). Butt hinges 100mmlong |
| 163 | 58. Supplying and fixing of brass fittings for doors etc., with necessary screws, etc as directed at site of work including all materials, labour, tools, equipments, etc. completea). Door Stopper with rubber bush (Heavy) with CP brass screw |
| 164 | b). Bright finished Brassbutt hinges 125mm |
| 165 | c).Bright finished Brass butt hinges 100mm |
| 166 | d). Bright finished Brass Tower bolts 150mmlong |
| 167 | e). Bright finished Brass handles 125 mm with plate 175x32 mm |
| 168 | 59. Supplying and fixing of Heavy Duty Stainless steel fittings for doors, etc., with necessary screws, etc as directed at site of work including all materials, labour, tools, equipments, etc. completea). Butt hinges - 125mm. |
| 169 | b). Butt hinges - 100mm. |
| 170 | c). Tower Bolt / Draw Bolt - 150mm |
| 171 | d). Tower Bolt / Draw Bolt - 75mm |
| 172 | e). Aldrop 250mm long |
| 173 | f). Door handle 125mm long |
| 174 | g). Door handle 100mm long |
| 175 | h). Magnetic catch for doors/cup boards |
| 176 | i). Hook and eyes 150mm long |
| 177 | j). Hook and eyes 50mm long |
| 178 | 60. Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of weathering course roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application /system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, all as per relevant specification as directed including all materials, labour, tools, equipments, etc., complete. |
| 179 | 61. Preparing the internal / external surfaces of walls by Removing the existing white or colour wash by scrapping and sand papering and preparing the surface, including applying putty to seal the cracks in the wall wherever required all as directed at site of work including all labour, materials, tools, tackles, equipments, brushes, scaffolding, etc., complete |
| 180 | 62. Preparing the surfaces of internal walls and applying one coat of primer (Asian / Nippon / Berger or equivalent))of approved brand and colour of good quality to give an even shadehaving low VOC (Volatile Organic Compound ) content all as directed at site of work including all labour, materials, tools, tackles, equipments, brushes, scaffolding, etc., complete |
| 181 | 63. Preparing the surfaces of existing interior walls / Ceilingsetc., and applyingtwocoatsofColour washing / White washing with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre (Asian / Nippon / Berger or equivalent) of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour all as directed at site of work including all labour, scaffolding, materials, tools, equipments, brushes, safety ladder, safetybelts, safety helmets, etc.,complete. |
| 182 | 64. Preparing the surfaces of existing external walls /sunshades / wherever required and applyingtwocoatsofColour washing with Exterior emulsion paint having VOC (Volatile Organic Compound ) content less than 50 grams/ litre (Asian / Nippon / Berger or equivalent) of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour all as directed at site of work including all labour, scaffolding, materials, tools, equipments, brushes, safety ladder, safetybelts, safety helmets, etc.,complete. |
| 183 | 65. Preparing the surfaces of Old Internal walls andpainting with two coats of synthetic enamel paint(colour) (Asian / Nippon / Berger or equivalent) of approved quality to give an even shade, all as directed including all materials, labour, scaffoldings, brushes, tools, equipments, etc., complete. |
| 184 | 66.Preparing the surfaces of old wooden members and painting with two coats of synthetic enamel paint(Asian / Nippon / Berger or equivalent) of approved quality to give an even shade, all as directed including all materials, labour, scaffoldings, brushes, tools, equipments, etc., complete.NOTE: 1. Necessary painting co-efficient shall be allowed as per ChPA engineering manual.2. The above quantity is inclusive of painting co-efficient. |
| 185 | 67.Preparing the surfaces of new wooden members and painting with two coats of Deluxe multi surface paint(Asian / Nippon / Berger or equivalent)of approved quality over coat of primer to give an even shade, all as directed including all materials, labour, scaffoldings, brushes, tools, equipments, etc., complete.NOTE: 1. Necessary painting co-efficient shall be allowed as per ChPA engineering manual.2. The above quantity is inclusive of painting co-efficient. |
| 186 | 68.Preparing the surfaces of old /New steel members and painting with two coats of synthetic enamel paint(Asian / Nippon / Berger or equivalent) of approved quality to give an even shade, all as directed including all materials, labour, scaffoldings, brushes, tools, equipments, etc., complete.NOTE: 1. Necessary painting co-efficient shall be allowed as per ChPA engineering manual.2. The above quantity is inclusive of painting co-efficient. |
| 187 | 69. Supplying of heavy dutybrass/SS/Aluminium fittings for doors, windows, cupboard etcin sound working condition etc., all as directed at site of work including all materials, labour, tools, equipments, etc., complete.a). Brass cupboard lock 6 lever of approved quality, 75mm size |
| 188 | b). Aluminium hanging floor door stopper with twin rubber & stopper |
| 189 | c). Stainless steel butt hinges 125x64x1.9mm |
| 190 | d). Anodised Aluminium tower bolt (barrel type) 150x10mm |
| 191 | e). Anodised Aluminium handles 125mm with plate 175x32mm |
| 192 | f). Anodised Aluminium Aldrop 250mm long |
| 193 | 70. Supplying diluting and injecting chemical emulsion for post constructional anti termite treatment with chlorpyrlphos Emulsifiable concentrate with 1% concentration (i.e. one litre of chemical for every 20 litires of emulsion) in hospital building basement treatment of soil along internal andexternal wall using chemical emulsion at 2.25 litire per linear metre inlcuding drilling and plugging holes etc. and treating the soil under floors, masonry / concrete inside and outside of buildings wherever required, using chemical emulsion at 1 litre per hole at 30cm interval including drilling 12mm dia holes and plugging them with cement mortar 1:2 to the full depth of the hole and treating the points of contact of wood work by chemical emulsion (in oil of kerosene based solution) at 0.5 litres per hole by drilling 6mm dia at downward angle of 45 degree at 150mm c/c and sealing the same and as directed including all material (including cement) labour, tools, scaffolding, ladder, equipments etc. complete |
| 194 | 71. Removing the existing glass panes in the fixed aluminium frames in aluminium windows wherever required and refixing with new Neoprene/EPDM rubber gasket/ sealeant, aluminium clips using existing glass panes, etc., all as directed at site of work including all labour, scaffolding, materials, tools, equipments, etc.,complete. |
| 195 | 72. Supplying of Foam board of various sizes for use of signage , identification and name boards whererver required all as directed at site of work including all labour material,tools, equipments, transport,etc.complete. |
| 196 | 73. Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat of size 45x85mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge and as directed at site of work including transporting, placing, all materials, labour, tools, plants, equipments, fuel, etc., complete. |
| 197 | 74. Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge and as directed at site of work including transporting, placing, all materials, labour, tools, plants, equipments, fuel, etc., complete.(Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 198 | 75. Providing and fixing First quality UPVC Ball valve to the water pipe lines in all floors in sound working condition including making the joints water tight and testing etc., all as directed at site of work including all materials, labour, tools, equipments, etc., complete.a). 25mm dia |
| 199 | b). 32mm dia |
| 200 | 76. Providing and fixing First quality Gun metal gate valve with CI wheel to the water pipe lines in all floors in sound working conditionincluding making the joints water tight and testing etc., all as directed at site of work including all materials, labour, tools, equipments, etc., complete.a). 20mm dia |
| 201 | b). 25mm dia |
| 202 | c). 32mm dia |
| 203 | 77. Engaging of the labours (Coolie) to shifting hospital fixtures / equipments wherever required to the opt places for day to day operation in a safer manner as directed as site including labour, tools, etc., complete. |
| 204 | 78. Deep cleaning the existing wall tiles, floor tiles and Mosaic tiles wherever required by using harmless chemical solution and as per manufactures specification all as directed including all labour, tools, equipments, chemical etc. complete. |
| 205 | 79. Removing, rolling, stacking and refixing the available mesh gap garware polyster safety materials over hospital buildingall as directed at site of work including all materials, labour, tools, equipments, etc., complete. |
| 206 | 80. Supplying, fabricating and fixing the M.S gate, window / Ventilator grill, Ladder as per existing or as directed at site using suitable structrual steel as verticles, horizontals and diagonal members,to the reqired length, welding the joints all as directed at site of work andproviding scaffolding, fixing gate in proper alignment, including painting with one coat of red oxide primer on the steel members, all as directed at site of work including cost of cement and all materials, labour, tools, transport, equipments, fuel, etc., complete.Note:1. The payment is based on the total weight of the MS flats, bars, etc., as fabricated. 2. The weighment will made at site or any other place as approved by the engineer-in-charge. Necessary charges for transport, weighment. etc., will be borne by the contractor. |
| 207 | 81. Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand for boxes, shelves, racks, almirah, cupboard and drawer etc. including necessary nails,screws etc.all as directed at site of work including all materials, labour, tools, transport, equipments, fuel, etc., complete. |
| 208 | 82. Supplying and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 crushed stone sand). Light shade pigment using white cement all as directed at site of work inclulding all labour, tools, tackles, equipments, fuel transport, etc. complete. |
| 209 | 83. a). Hire charges for Tractor with trailor forshift basis (8 hours) for conveying unwanted materials steel/ wooden / Rubber materials/leavesetc to RSO yard /dumping yard with Labour Engaged for lifting the scraps etc..,Loading and unloading materials etc., all as directed at site of work inclulding all labour, tools, tackles, equipments, fuel transport, etc. complete.Note : The required labour will be supplied under relevant item in BoQ. |
| 210 | b). DeploymentofLabour (Coolie)(3Nos/shift) and engaged 10 shifts |
| 211 | 84. Operating of vehicle mounted Heavy duty jetting cum suction machine including diesel with driver and operator for cleaning sewer lines, septic tank, manholes including loading and disposing the wastewherever required as directed at site including all labour, tools, equipments, transport, fuel, etc., complete.Note: 1. For handling/cleaning the machine, the cost of labour charges will be bone by the contractor.2. The required water will be given in the near by site area at free of cost.3. The rate shall be inclusive of diesel, all tools and plants etc., complete.4. The contractor has not claim any charge for damaged parts. 5. The unwanted materials like silt or any garbage to be dumped at open area as directed by the department.6. If any Break down or labour problem during working time deduction will be calculated proportionately based on the rate per day/per hour. |
| 212 | 85. Dewatering using 10 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges wherever required as directed at site including all labour, tools, equipments, transport, fuel, etc., complete. |
| 213 | 86. Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., all as directed at site of work including all labour,materials, tools, equipments, etc.,complete. |
| 214 | 87. Supplying and fixing20mm dia PVC Pipe for AC water drain outlet, with all required accessories like tees, bends, couplings, elbows, reducers, unions, etc.,jointing of pipes & fittings with PVC solvent and testing of joints andincluding cutting the masonry/concrete wherever required and making good the disturbed portions, all as per relevant specification and directed at site of work,labour, tools, equipments, scaffolding etc., completeNote: Necessary Cutting of Brick work, Concrete, Plastering, etc., will be paid under relevant items of BOQ. |
| 215 | 88. a). Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. |
| 216 | b). Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Fixed window / ventilator with mullion / transom.Using R4 series with frame (64mm & above ) x (50mm & above) & mullion (64mm & above) x (70mm & above). (Height above 2.5 metre)Note: Glass area will be measured and paid separately as per relevant BoQ. |
| 217 | 89. Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Three track three panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (98mm & above) x (40mm & above) & sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on two end panels along with multi-point locking system (Height upto 1.8 metre).Note: Glass area will be measured and paid separately as per relevant BoQ. |
| 218 | 90. Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Two and half track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (65mm & above) x (40mm & above) & glazed sash (25mm & above) x (50mm & above) & fly screen sash (18mm & above) x (40mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre). Note: Glass area will be measured and paid separately as per relevant BoQ. |
| 219 | 91. Providing and fixing good quality polyester fabric (washable) vertical blinds (100mm wide) with anodized aliminium top rails, wheels in poly carbonate runners for smooth movement and self adjustable unbreakable Teflon spacers, trouble free control unit, bottom chain, fitting chain galvanised steel bottom weight, abord weight including all accessories etc. all as directed including all materials, labour, tools, equipments, scaffolding etc. complete. |
| 220 | 92. Providing and fixing good quality non - reflective type sun control film (Garware or equivalent) of thickness 50mm microns to the glasspanels of the partition / doors / windowsincluding thoroughly cleaning the glass panels and removing the stain if any, with good quality soap or liquid detergents, removing any other foreign particles etc., all as directed including all materials, labour, tools, etc., complete. |
| 221 | 93. Engaging of labour for removal of unwanted vegetation growth in all floors of the building wherever requiredall as directed including labour, materials, tools, equipments, transport, fuel, etc., complete. |
| 222 | 94. Providing and laying Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 CS sand), 25mm thick all as directed including all materials, labour, tools, etc., complete. |
| 223 | 95. Providing and laying 40mm thick granolithic flooring in C.C. 1:2:4 in volumetric proportions (1 cement : 2 crushed stone sand : 4 hard granite graded stone aggregate 12.5mm nominal size) including finishing coat of neat cement at 2.20Kg/m2, including mixing, transporting, placing ramming, consolidating, curing,etc.,all as directed includingcement and all othermaterials, labour,tools, equipments, etc. complete. |
| 224 | 96. Providing and fixing SFRC (Steel Fiber Reinforced Concrete) Manhole cover with frame of size as directed for Manhole and wherever required in mix 1:1.5:3 ( 1 cement : 1.5 C.S.sand : 3 hard granite graded stone aggregate of 20mm nominal size) in volumetric proportions to the required size, all as per relevant specifications, drawings and as directed includingnecessary form work, mixing, transporting, placing, compacting, curing, finishing the exposed concrete surface withneat cement punning at 2.2 kg/Sq.m as directed, including lifting, handling, transporting and placing the cover over the frame in correct position and alignment, providing necessary lifting holes including all materials, labour, tools, plants, equipments, fuel, etc., complete.a). 900mm x 900mm |
| 225 | b). 600mm x 600mm |
| 226 | 97. Supplying and fixing of good quality insects preventing PVC netlon mesh without country weed reepers consisting of 1.8mm X1.8mm apexture for size (Approx) to the window openings andventilators etc., and wherever required after removing the old damaged mesh including providing 25mm wide hook fasteners nailed stabled continuously on all the four sides of the existing upvc frames with suitable hook and loop fasteners tailored on the edges of the screen all of approved quality and as directed at site of work including all labours, materials, fabrication, tools, equipments, scaffoldings, etc., complete. |
| 227 | 98. Removing the exisitng wornout Aluminium sliding door and re-placing with UPVC (Un-Plasticized Polyvinyl Chloride) Two track two panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system, adjustable nylon rollers with SS 304 body Using R4 series with frame (64mm & above) x (45mm & above) & sash (44mm & above) x (85mm & above). (Height above 2.5 metre) all as directed at site of work including all labours, materials, fabrication, tools, equipments, scaffoldings, etc., complete. |
| 228 | 99. Removing wornout GI pipe outlet / delivery pipe embedded in the RCC Over head tank above staircase Head room and Providing and fixingGI pipe / Gun Metal Gate Valve for Delivery / Washout pipe all as directed at site of work including all labours, materials, fabrication, tools, equipments, etc., complete.Note: Necessary Cutting of RCC, laying of concrete and finishing with CM 1:3, 20mm thick with admixtures etc., will be paid under relevant items of BOQ.a). 50mm dia GI Pipe |
| 229 | b). 50mm dia Gate Valve (Heavy Duty) |
| 230 | 100. Loading, transporting, dumping and leveling the surplus earth and debris etc., within a lead of 3kms out side the Port premises all as per relevant specifications and as directed including all labour, transport, tools, equipments, fuel, etc., complete. Note:1.The tenderer shall maintain trip sheets in triplicate in ChP\"s approved format at his own cost.2.Payment will be based on the lorry cubical content. No deduction of voids for debris will be made. 4. 20%deduction of voids for surplus earthwill be made. However the final quantity will be restricted to actual quantity of debris dismantling /demolishing items.(a) Surplus Earth |
| 231 | b). Debris |
| 232 | Schedule- A3Electrical work |
| 233 | 1).Supply and Install / Replacing of Electric Flying Insect Killer Machine 2 feet. Wall Mounted or Free Standing - Hanging Chain Included Removable Catchment Tray For Dead Insect Bodies, Easily Cleanable Without Insect Contact as per Schedule ‘A’. |
| 234 | 2.Supply and Install / Replacing of Distribution Board – I comprising of 1 No 125A 4P 25 kA MCCB as incomer 2 Nos 63A TP MCB, 6 Nos 32A SP MCB, 12 Nos 20A SP MCB, 12 Nos 16A SP MCB, \"B\" Series MCB and 9 Nos 10A SP MCB, \"B\" Series MCB as outgoing with suitable copper wires / busbar for each phase and neutral connection with earth link and all other components and accessories as per Schedule ‘A’. |
| 235 | 3.Supply and Install / Replacing of Distribution board - II shall be comprising with suitable way of 1 No 100 A 4P, 25 kA MCCB as incomer and 2 Nos 63A TP MCB, 3 Nos 32A SP MCB, 6 Nos 20A SP MCB, 6 Nos 20A SP MCB, \"C\" Series MCB12 Nos 16A SP MCB, \"B\" Series MCB and 12 Nos 10A SP MCB, \"B\" Series MCB as outgoing with suitable copper wires / busbar for each phase and neutral connection with earth link and all other components and accessories as per Schedule ‘A’. |
| 236 | 4.Supply and Install / Replacing of Distribution Board - III comprising of 1 No 63A, 4P, MCCB as incomer and 2 Nos 32A TP MCB, 12 Nos 20A SP MCB, \"C\" Series MCB and 12 Nos 10A SP MCB, \"B\" Series MCB as outgoing with suitable copper wires / busbar for each phase and neutral connection with earth link and all other components and accessories as per Schedule ‘A’. |
| 237 | 5.Supply and Install / Replacing of Distribution Board – IV comprising of 1 No 63A 4P MCCB as incomer and 1 Nos 32A TP MCB, 3 Nos 20A SP MCB, 9 Nos 16A SP MCB, \"C\" Series MCB and 9 Nos 10A SP MCB, \"B\" Series MCB as outgoing with suitable copper wires / busbar for each phase and neutral connection with earth link and all other components and accessories as per Schedule ‘A’. |
| 238 | 6.Supply of 4 Feet 2 X 20w Box type LED BOX TYPE FITTING with T8 LED Tube light with SINGLE SIDE connection and all other accessories as per Schedule ‘A’. |
| 239 | 7.Supply of 4 Feet 1 X 20w Box type LED BOX TYPE FITTING with T8 LED Tube light with SINGLE SIDE connection and all other accessories as per Schedule ‘A’. |
| 240 | 8.Installation Surface/ Recessed of 4 Feet BOX TYPE FITTING light fitting with suitable down rods, brackets as per Schedule ‘A’. |
| 241 | 9.Supply of suitable Down Rod for 4 Feet Tube Light Fittings as per Schedule ‘A’. |
| 242 | 10.Supply of 2 Feet 10 W Moulded type MIRROR LED Fittings with all connections other accessories as per Schedule ‘A’. |
| 243 | 11.Installation of above Moulded type LED Mirror light fittings as per Schedule ‘A’. |
| 244 | 12.Supply of recess type diffused LED 20 W Bulk Head light fitting suitable for 220V, full bright at various locations as per Schedule ‘A’. |
| 245 | 13.Installation of Bulk Head light fittings as per Schedule ‘A’. |
| 246 | 14.Supply and Install LED 0.5 W BULB FOR B22 holder suitable for 220V, full bright at various locations as per Schedule ‘A’. |
| 247 | 15.Supply and Install / Replace of recess type diffused LED 7\" round 12 W light fitting WITH BULB suitable for 220V, full bright at various locations as per Schedule ‘A’. |
| 248 | 16.Supply and Install / Replacing to be mount in the Surface/ Recessed 220V CALLING BELL with 6 different sounds along with base plates Junction Box and ceiling rose including terminations for all units. including supply of modular switch boxwith all other accessories etc. as per Schedule ‘A’. |
| 249 | 17.Supply and Install / Replace of one number 63A FP, MCCB with suitable connections and Metal type ENCLOSURE (\"C\" series MCCB) at various locations as per Schedule ‘A’. |
| 250 | 18.Supply and Install / Replace of one number 32A FP, MCCB with suitable connections and Metal type ENCLOSURE (\"C\" series MCCB) at various locations as per Schedule ‘A’. |
| 251 | 19.Supply and Install / Replace of one number 32A DP, MCB with suitable connections and Metal type ENCLOSURE (\"C\" series MCB) at various locations as per Schedule ‘A’. |
| 252 | 20.Supply and Install of one number 16A/20A DP, MCB with suitable connections and Metal type ENCLOSURE (\"C\" series MCB) at various locations as per Schedule ‘A’. |
| 253 | 21.Supply and Install / Replace of one number 32A DP, MCB with suitable connections on the EXISTING Metal type ENCLOSURE / DB (\"C\" series MCB) at various locations as per Schedule ‘A’. |
| 254 | 22.Supply and Install / Replace of one number 20A SP, MCB with suitable connections on the EXISTING Metal type ENCLOSURE / DB (\"C\" series MCB) at various locations as per Schedule ‘A’. |
| 255 | 23.Supply and Install / Replace of one number 16A SP, MCB with suitable connections on the EXISTING Metal type enclosure / DB (\"C\" series MCB) as at various locations as per Schedule ‘A’. |
| 256 | 24.Supply and Install / Replace of one number 10A SP, MCB with suitable connections on the EXISTING Metal type ENCLOSURE / DB (\"B\" series MCB) at various locations as per Schedule ‘A’. |
| 257 | 25.Supply and Installation / Replace of 6 Way Metal Box Enclosure as per Schedule ‘A’. |
| 258 | 26.Supply and Installation / Replace of 8 Way Metal Box Enclosure as per Schedule ‘A’. |
| 259 | 27.Supply and Install / Replace Surface/ Recessed of all materials and accessories for 16A/15A MODULAR type switch and socket outlet along with base plates, FRAME AND WITH SUITABLE BOX connections as per Schedule ‘A’. |
| 260 | 28.Supply and Install / Replace Surface/ Recessed of all materials and accessories for 2 Nos 5A MODULAR type switch and socket outlet along with base plates, FRAME AND with SUITABLE BOX connections as per Schedule ‘A’. |
| 261 | 29.Supply and Install / Replacing to be mount in the Surface/ Recessed switch board of all materials of 5 Amps Modular Switch and Socket outlet to be mounted in the modular type Sub Switch Board itself, including base plates, FRAME and wiring to the plug as per Schedule ‘A’. |
| 262 | 30.Supply and Install / Replacing to be mount in the Surface/ Recessed switchboard of all materials of 5 Amps modular switch including supply of modular switch box with all other accessories to control of fan, light etc. as per Schedule ‘A’. |
| 263 | 31.Supply and Install / Replacing to be mount in the Surface/ Recessed switchboard of all materials of 5 Amps MODULAR Bell push switch including supply of modular switch boxwith all other accessories to control of fan, light etc. as per Schedule ‘A’. |
| 264 | 32.Supply of 1200 MM, brown colour sweep Ceiling fan, with wide blades, suitable down Rod, electronic regulator and all other accessories as per Schedule ‘A’. |
| 265 | 33.Installation of Ceiling fan as per Schedule ‘A’. |
| 266 | 34.Supply of suitable Down Rod for Ceiling fan with as per Schedule ‘ A’. |
| 267 | 35.Supply of 450 mm sweep, Wall mounting fan with polypropylene plastic blade, powder coated metal body and guards with speed control and all other accessories as per Schedule ‘A’. |
| 268 | 36.Supply of 400 mm sweep, Wall mounting fan with polypropylene plastic blade, powder coated metal body and guards with speed control and all other accessories as per Schedule ‘A’. |
| 269 | 37.Installation of above Wall mounting fans as per Schedule ‘A’. |
| 270 | 38.Supply of 450 mm sweep, Pedestal fan with polypropylene plastic blade, powder coated metal body and guards with speed control and all other accessories as per Schedule ‘A’. |
| 271 | 39.Supply of 18” size of Exhaust fan with necessary clamps and accessories for all units as per the technical specifications as per Schedule ‘A’. |
| 272 | 40.Installation of above Exhaust fan as per Schedule ‘A’. |
| 273 | 41.Supply of 15” size of Exhaust fan with necessary clamps and accessories for all units as per the technical specifications as per Schedule ‘A’. |
| 274 | 42.Installation of above Exhaust fan as per Schedule ‘A’. |
| 275 | 43.Supply of 12” size of Exhaust fan with necessary clamps and accessories for all units as per the technical specifications as per Schedule ‘A’. |
| 276 | 44.Installation of above Exhaust fan as per Schedule ‘A’. |
| 277 | 45.Supply of 9\"\" size of Exhaust fan with necessary clamps and accessories for all units as per the technical specifications as per Schedule ‘A’. |
| 278 | 46.Installation of above Exhaust fan as per Schedule ‘A’. |
| 279 | 47.Supply of 15 litre, 2000 Watts storage water heater with ABS body and PUF insulation as per Schedule ‘A’. |
| 280 | 48.Installation of above Heater as per Schedule ‘A’. |
| 281 | 49.Supply of EXTENSION BOX that contains 3 Nos 5A MODULAR type switch and 5 PIN socket along with 5 metre 1.5 sqmm 3 core Workshop flexible copper cable and 5A 3 pin TOP outlet along with Suitable connections as per Schedule ‘A’. |
| 282 | 50.Supply of EXTENSION BOX that contains 2 Nos 15A/5A MODULAR type switch and 6 PIN socket along with 5 metre 2.5 sqmm 3 core Workshop flexible copper cable and 15A 3 pin TOP outlet along with Suitable connections as per Schedule ‘A’. |
| 283 | 51.LAYING of 1.25 INCH PVC Pipe in the FLOOR / WALL by CONCEALED. The Contractor shallcut the groove on the wall as per the requirement, after laying the pipe & wire, the same area shall be replaster the groove as per Schedule ‘A’. |
| 284 | 52Supply and wiring of all materials and accessories to carry out the surface/concealed wiring by using suitable size of PVC conduit /Casing and capping with 2 runs 1.5 Sq.mm and one run 1.0 Sq.mm FRLS PVC insulated unsheathed multistrand copper conductor multistrand wires for Phase, Neutral and Earth. From SSB to Individual PT for Fans, Tube lights etc., through connected junction/ inspection boxes along with modular flush type control switch along with base plates and ceiling rose including terminations wherever necessary as per the technical specifications as per Schedule ‘A’. The Contractor shallcut the groove on the wall as per the requirement, after laying the pipe & wire, the same area shall be replaster the groove. |
| 285 | 53.Supply and Wiring of all materials and accessories and to carry out the surface/concealed with suitable size of PVC conduit /CASING and Capping wiring by using with 4 runs 10 sq.mm and one run of 6 Sq.mm FRLS PVC insulated unsheathed multistrand copper conductor wires etc., through connected junction/ inspection boxes along with terminations wherever necessary as per Schedule ‘A\". The Contractor shallcut the groove on the wall as per the requirement, after laying the pipe & wire, the same area shall be replaster the groove. |
| 286 | 54.Supply and Wiring of all materials and accessories and to carry out the surface/concealed with suitable size of PVC conduit /CASING and Capping wiring by using with 4 runs 6 sq.mm and one run of 4 Sq.mm FRLS PVC insulated unsheathed multistrand copper conductor wires etc., through connected junction/ inspection boxes along with terminations wherever necessary as per Schedule ‘A\". The Contractor shallcut the groove on the wall as per the requirement, after laying the pipe & wire, the same area shall be replaster the groove. |
| 287 | 55.Supply and Wiring of all materials and accessories and to carry out the surface/concealed with suitable size of PVC conduit /CASING and Capping wiring by using with 4 runs 4 sq.mm and one run of 2.5 Sq.mm FRLS PVC insulated unsheathed multistrand copper conductor wires etc., through connected junction/ inspection boxes along with terminations wherever necessary as per Schedule ‘A\". The Contractor shallcut the groove on the wall as per the requirement, after laying the pipe & wire, the same area shall be replaster the groove. |
| 288 | 56.Supply and Wiring of all materials and accessories and to carry out the surface/concealed with suitable size of PVC conduit /CASING and Capping wiring by using with 2 runs 6 sq.mm and one run of 4 Sq.mm FRLS PVC insulated unsheathed multistrand copper conductor wires etc., through connected junction/ inspection boxes along with terminations wherever necessary as per Schedule ‘A\". The Contractor shallcut the groove on the wall as per the requirement, after laying the pipe & wire, the same area shall be replaster the groove. |
| 289 | 57.Supply and Wiring of all materials and accessories and to carry out the surface/concealed with suitable size of PVC conduit /CASING and Capping wiring by using with 2 runs 4 sq.mm and one run of 2.5 Sq.mm FRLS PVC insulated unsheathed multistrand copper conductor wires etc., through connected junction/ inspection boxes along with terminations wherever necessary as per Schedule ‘A\". The Contractor shallcut the groove on the wall as per the requirement, after laying the pipe & wire, the same area shall be replaster the groove. |
| 290 | 58.Supply and Wiring of all materials and accessories and to carry out the surface/concealed with suitable size of PVC conduit /CASING and Capping wiring by using with 2 runs 2.5 sq.mm and one run of 1.5 Sq.mm FRLS PVC insulated unsheathed multistrand copper conductor wires etc., through connected junction/ inspection boxes along with terminations wherever necessary as per Schedule ‘A\". The Contractor shallcut the groove on the wall as per the requirement, after laying the pipe & wire, the same area shall be replaster the groove. |
| 291 | 59.Supply and Wiring of all materials and accessories and to carry out the surface/concealed with suitable size of PVC conduit /CASING and Capping wiring by using with 2 runs 1.5 sq.mm and one run of 1.0 Sq.mm FRLS PVC insulated unsheathed multistrand copper conductor wires etc., through connected junction/ inspection boxes along with terminations wherever necessary as per Schedule ‘A\". The Contractor shallcut the groove on the wall as per the requirement, after laying the pipe & wire, the same area shall be replaster the groove. |
| 292 | 60.Supply of 4 core 25 Sq.mm L.T. underground cable of 1100 V galvanized steel strip armoured XLPE cable with stranded Aluminium conductorconforming to IS 7098 Part I 1985 with latest amendments with ISI mark for various locations as per Schedule ‘A’. |
| 293 | 61.Laying of the cable on the wall by Alu. Clamping with equal intervals with all other accessories as per Schedule ‘A’. |
| 294 | 62.Laying of the cable of through on the tray as per Schedule ‘A’. |
| 295 | 63.Supply of 4 core 16 Sq.mm L.T. underground cable of 1100 V galvanized steel strip armoured XLPE cable with stranded Aluminium conductorconforming to IS 7098 Part I 1985 with latest amendments with ISI mark for various locations as per Schedule ‘A’. |
| 296 | 64.Laying of the cable on the wall by Alu. Clamping with equal intervals with all other accessories as per Schedule ‘A’. |
| 297 | 65.Laying of the cable of through on the tray as per Schedule ‘A’. |
| 298 | 66.Removal of Existing All kind of Cables, Wirings, Light fittings, all kind of Fans, Panels and DBs as per Schedule ‘A’. |
| 299 | Schedule- A4 Electronics & Communication-Telephone Communication work, |
| 300 | 1). Supply of 50 pair 0.5 mm copperunarmoured PVC cablePreferred make : Finolex / PolyCab/Legrand |
| 301 | 2). Supply of 20 pair (15 mm copper unarmoured PVC cablePreferred make : Finolex /PolyCab/Legrand |
| 302 | 3). Supply of 5 pair 0.5 mm copper unarmoured PVC cable Preferred make : Finolex I PolyCab/Legrand |
| 303 | 4). Supply and Laying of size PVC casing & capping for the laying 50 pair 0.5 mm copper unarmoured PVC cable inside the cabin |
| 304 | 5). Supply and Laying of 1 1/2\" size PVC casing & capping for the laying 20 pair 0.5 mm copper unarmoured PVC cable inside the cabin |
| 305 | 6). Supply and Laying of 1\" size PVC casing & capping for the laying 5 pair 0.5 mm copper unarmoured PVC cable inside the ca in |
| 306 | 7). Supply and Installation of Krone connector |
| 307 | 8). Supply of Installation of I/O Box |
| 308 | 9). Supply and Installation of 50 pair junction box with Krone Connector |
| 309 | Schedule- A5 Electrical- Power supply work, |
| 310 | 1). Charges for Dismantling, Removal, Loading, Transporting, Dumping of old, reduntant various Alu power cables and LT panels etcfrom Hospital complex to RSD |
| 311 | 2). Supply & Laying of 4core 70, Aluminium conductor XLPE L.T. cablea). Supply |
| 312 | b). Laying Inconcrete trench |
| 313 | c). Laying on cable Tray |
| 314 | d). Laying Underground |
| 315 | e).End termination for 4Core x 70 |
| 316 | 3). Supply & Laying of 3.5 core 185, Aluminium conductor XLPE L.T. cablea). Supply |
| 317 | b). Laying Inconcrete trench |
| 318 | c). Laying on cable Tray |
| 319 | d). Laying Underground |
| 320 | e). End termination for 3.5 x 185 |
| 321 | 4). Supply & Laying of 3.5c150sqmm LT Alu cablea). Supply |
| 322 | b). In concrete trench |
| 323 | c). On FRP cable tray |
| 324 | d). Under ground |
| 325 | e). End termination |
| 326 | 5). Supply & Laying of 4c95 sqmm LT Alu cablea). Supply |
| 327 | b). Laying in Concrete trench |
| 328 | c). On FRP cable tray |
| 329 | d). Underground |
| 330 | e). End termination |
| 331 | 6. Supply& laying of 4core 50 square mm alu xlpe lt cablea). Supply |
| 332 | b). Laying in Concrete trench |
| 333 | c). On FRP cable tray |
| 334 | d). Under Ground |
| 335 | e). End termination 4core 50sqmm |
| 336 | 7. Supply& laying of 4core 25 square mm alu xlpe lt cablea). Supply |
| 337 | b). Laying in Concrete trench |
| 338 | c). On FRP cable tray |
| 339 | d). Under ground |
| 340 | e). End termination 4core 25 |
| 341 | 8. Supply& laying of 4core 16 square mm alu xlpe lt cablea). Supply |
| 342 | b). Laying in Concrete trench |
| 343 | c). On FRP cable tray |
| 344 | d). Under ground |
| 345 | e). End termination 4c16sqmm |
| 346 | 9. Supply installation testing commsioning of wall mountedLT Panel -I comprising250Amps 4 pole incomer MCCB and 3 NoS 100AmPs MCCBas out goinga). Supply |
| 347 | b). Installation Testing commissioning |
| 348 | 10). Supply installation testing commsioning ofwall mounted LT Panel -II comprising 2 nos 400 Amps 4p MCCB as incomers, 10 Nos 100Amps, 4p,MCCBS, 1 Nos. 250A MCCB 4P as out going feedersa). Supply |
| 349 | b). Installation Testing commissioning |
| 350 | 11). Supply installation testing commsioning of wall mounted LT Pane-III comprising 630 Amps 4p MCCB as incomer and 8 Nos 100A 4p MCCB and 6 Nos 63A 4P MCCB as outgoing feedersa). Supply |
| 351 | b). Installation Testing commissioning |
| 352 | 12). Supply installation testing commsioning ofFloor Mounted LT feeder pillar outdoor with250Amps 4P MCCB as Incomer and 6 nos 100A 4p MCCB 6 nos 63A 4P MCCB as outgoinga). Supply |
| 353 | b). Installation Testing commissioning |
| 354 | 13). Supply installation testing commsioning of wall mounting LT Panel -IV comprising 250Amps MCCB as incomer, and1 no 100A MCCB 8 Nos 63 amps 4p mccb as outgoinga). Supply |
| 355 | b). Installation Testing commissioning |
| 356 | 14). Charges for Rerouting of various size LT cables 16 sqmm to 300 sqmm including dis connection and reconnectiona). In trench |
| 357 | b). FRP cable tray |
| 358 | c). Underground |
| 359 | 15). Supply and Mounting of FRP cable Tray Ladder Type 600 mm widtha). Supply |
| 360 | b). Mounting along the wall with Angle Grouting |
| 361 | 16). Supply and Mounting of FRP cable Tray Ladder Type 300 mm widtha). Supply |
| 362 | b). Mounting along the wall with Angle Grouting |
| 363 | 17). Supply & mounting FRP cable TRAY ladder type 150mm widtha). Supply |
| 364 | b). Mounting along the wall with Angle Grouting |
| 365 | 18). Supply & Mounting of cone type FRP junctions for 500 mm to 300mm traya). Supply |
| 366 | b). Mounting along the wall with Angle Grouting |
| 367 | 19). Supply & Mounting of cone type FRP junctions for 500 mm tray to 150mma). Supply |
| 368 | b). Mounting along the wall with FRP/MS Angle Grouting |
| 369 | 20). Supply & Mounting of cone type FRP junctions for 300 mm tray to 150mma). Supply |
| 370 | b). Mounting along the wall withMS/FRPAngle Grouting |
| 371 | 21). SITC of Permanent Earth Electrodea). Supply |
| 372 | b). Installation Testing commissioning |
| 373 | 22). Supply & laying of GI Earth Strip 40mm*5mma). Supply |
| 374 | b). Laying and interconnecting |
| 375 | 23). Supply & laying of GI Earth Strip 25mm*6mma). Supply |
| 376 | b). Laying and interconnecting |
| 377 | 24). SITC of AC DBs with 100A MCCB 4P as Incomer and 16 Nos 20A DP MCB as outgoinga). Supply |
| 378 | b). Installation Testing commissioning |
| 379 | 25). Supply and Laying of GI earthwire 8 SWGa). Supply |
| 380 | b). Laying |
| 381 | 26). Supply and providing cable Joints for various size LT cablesa). Supply of Joint Kit 3.5.Core 185 Sqmm |
| 382 | b). Providing Joint |
| 383 | c). Supply of Joint Kit 3.5.Core 150 Sqmm |
| 384 | d). Providing Joint |
| 385 | e). Supply of Joint Kit for 4x95,4x70, 4x50, 4x25, 4x16 cables (2 Nos. Each) |
| 386 | f). Providing Joint for above cables |
| 387 | 27). Supply& Installation of 100KVAR AFC panel,indoorFloor Mounted , Top side Cable Entry 415V, 3-phase, 50Hz microcontroller-based APFC relay for automatic power factor correction, capacitor duty contactors, individual MCB protection for each capacitor bank, a current transformer (CT) for accurate current sensing, and a digital display for parameters like voltage, current, and power factor. The panel will also have specific features such as auto/manual mode, screen hold, and overload protectionwith 200A,50KA, 4P MCCB as incomera). Supply |
| 388 | b). Installation Testing& commissioning |
| 389 | Schedule- A6-Air Condition with CAMC |
| 390 | ITEM – I Supply and Installation1). Cost for supply of Non Inverter Type 2 TR capacity 3 star rated slim high wallmounting type split air conditioner along with all requiredmaterials and accessories, as per schedule ‘A’. |
| 391 | 2). Cost for installation of Non Inverter Type 2 TR capacity 3 star rated slim high wall mounting type split air conditioner, as per schedule ‘A’ |
| 392 | ITEM – IICAMC for 5 yearsCharges for Comprehensive Annual Maintenance Contract for 25 Nos. 2 TR, 3 Star rated Split Air Conditioners at various locationNote: The CAMC rate is per unit per month.During the CAMC period the firm shall do servicing of Air Conditioners in a period of 3 months (i.e., 4 times in a year for each AC) and attending break down calls as and when informed by Engineer-in-Charge)a). 1st Year |
| 393 | b). 2nd year |
| 394 | c). 3rd year |
| 395 | d). 4th Year |
| 396 | e). 5th Year |
| 397 | Schedule- A7 Pipeline Works |
| 398 | Medical Block:1). Supply and fixing of CPVC Pipeline 50mm dia, Trubore/ Finolex or equivalent (Internal work exposed on wall) wherever necessary including cost of fittings, fixing the pipe with clamps at 1.00m spacing all as directed at site of work including all labour, tools, equipment, etc. complete. |
| 399 | 2). Supply and fixing of CPVC Pipeline 25mm dia, Trubore/ Finolex or equivalent (Internal work exposed on wall ) wherever necessary Including cost of fittings all as directed at site of work Including all labour, tools, equipment, etc. complete. |
| 400 | 3). Supply and fixing of CPVC Pipeline 25mm dia, Trubore/ Finolex or equivalent (Concealed work, including cutting chases and making good the walls etc.) wherever necessary Including cost of fittings, fixing the pipe with clamps at 1.00m spacing all as directed at site of work Including all labour. tools, equipments, etc. complete. |
| 401 | 4). Supply and fixing of CPVC Pipeline 20mm dia, Trubore/ Finolex or equivalent (Concealed work, including cutting chases and making good the walls etc.) wherever necessary including cost of fittings, the pipe with clamps at 1.00m spacing all as directed at site of work including all labour, tools, equipments. etc. complete. |
| 402 | Surgical Block:5). Supply and fixing of CPVC Pipeline 50mm dia, Trubore/ Finolex or equivalent (Internal work exposed on wall) wherever necessary including cost of fittings, fixing the pipe with clamps at 1.00m spacing all as directed at site of work including all labour, tools, equipment, etc. complete. |
| 403 | 6). Supply and fixing of CPVC Pipeline 25mm dia, Trubore/ Finolex or equivalent (Concealed work, including cutting chases and making good the walls etc.) wherever necessary Including cost of fittings, fixing the pipe with clamps at 1.00m spacing all as directed at site of work Including all labour. tools, equipments, etc. complete. |
| 404 | 7). Supply and fixing of CPVC Pipeline 20mm dia, Trubore/ Finolex or equivalent (Concealed work, including cutting chases and making good the walls etc.) wherever necessary including cost of fittings, the pipe with clamps at 1.00m spacing all as directed at site of work including all labour, tools, equipments. etc. complete. |
| 405 | 8). Supply and fixing of G I. pipeline 50mm dia (C-Class) (Internal work exposed on wall) complete with GI fittings and clamps at1.00m spacing,including cutting chases and making good the walls wherever necessaryall as directed at site of work Including all labour, tools, equipments, etc. complete |
| 406 | 9). Supply and fixing of G I. pipeline 50mm dia (C-Class) (External work) complete with 0.1. fittings, including trenching and refilling etc. wherever necessary all as directed At site of work including labour, tools, equipments, etc., complete |
| 407 | 10). Supply and fixing of 2\" Gun Metal Non-Return Valve(Horizontal) |
| 408 | 11). Supply and fixing of 2\" Gun Metal Gate Valve |
| 409 | 12). Supply and fixing of 3/4\" CPVC Ball Valve |
| 410 | 13). Supply and fixing of I CPVC Ball Valve |
| 411 | 14). Dismantling of existing pipeline PVC / UPVC/G.I. of sizes 3/4\" Dia , 1\" Dia and 2\" Dia and shifting to RSA Yard |
| 412 | RO WATER PIPELINES15). Supply and fixing of CPVC Pipeline 25mm dia, Trubore/ Finolex or equivalent (Concealed work, including cutting chases and making good the walls etc.) wherever necessary including cost of fittings, fixing the pipe with clamps at 1.00m spacing all as directed at site of work including all labour, tools, equipments, etc. complete |
| 413 | 16). Supply and fixing of 1\" - CPVC Ball Valve |
| 414 | Schedule- A8 Replacement of Gas pipeline to Kitchen |
| 415 | 1). Supplying and fixing ofstainless steel 304 Grade 12 mm dia seamless pipeincluding valve, manifold, flexiable tubes, etc and connection with cooking equipments including fixing in proper positionall as directed at site of work including all labour, tools, equipment, etc. complete. |
| 416 | Schedule- A9 Replacement of Oxygen pipeline system-(i) Medical Block |
| 417 | 1). Medical Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling). The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg. / cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection. The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V. The pipelines installed at the various wings and floors etc., complete as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. (i)76mm OD X 1.5mm thick |
| 418 | ii).42mm OD X 1.2mm thick |
| 419 | iii).28mm OD X 0.9mm thick |
| 420 | iv).22mm OD X 0.9mm thick |
| 421 | v).15mm OD X 0.9mm thick |
| 422 | vi).12mm OD X 0.9mm thick |
| 423 | 2). SITC of Primary Oxygen Source System.(i)Liquid Medical Oxygen (LMO) tank 3KL |
| 424 | 2(ii) VIE Vaporizer 300nm3 |
| 425 | 2(iii)Stainless Steel Pipe and Flange Tube Workfrom LMO to VIE Vaporizer |
| 426 | 2(iv) High Pressuring Regulating System(Working & Standby) for LMO Tank |
| 427 | 3.SITC of Manifolds ( without Cylinders):(i). Pressure Gauge |
| 428 | 3(ii). Oxygen manifold arrangements of 2 banks x 20 cylinder each wing with semi automatic control panel which includes contact gauge 2 Nos., outlet pressure gauge, brass heavy duty IO x regulator 2 Nos. with suitable adopter, flexible SS Hose. Mainfold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 1282-1989. Emergency alarms with illuminating display for low / high pipeline pressure and malfunctioning of system. 1) Mainfold top frame with provision for connecting 12 cylinders on right bank and 12 cylinders on left bank with high pressure interconnecting copper tubing, silver brazing, non return valve, fasteners and cylinder spport middle angle frame for claping 2 x 12 cylinders and related fasteners. The O2 manifold should with stand a pressure of 140 kg. / CM2. The installation is commissioned after testing as per standards and painted as per International Code and as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. - |
| 429 | 4). SITC of Secondary Oxygen Source System:Digital Fully Automatic Oxygen Control System: 3 Source Control Panel with Primary Ist as liquid with PRS system for liquid oxygen and Secondary as Manifold. The heavy duty control panel to be provided with a flow capacity of approx 2666 LPM at 50 to 60 psi with .CE Certified, ETL Listed / Country of Orgin : Germany. |
| 430 | 5).Compressed Medical Air System: Supply, installation, testing and commissioning of Compressed Air System of Reciprocating Oil Free Air Compressor Belt Driven Type 10 HP Air Compressor with following provisions. As per IS 12827 / 1987 & ISO 7396 / 1987 Specification Compressor package consists of following: a) 10 HP Air Compressor - 1 No.b) Electric Motor 10 HP - 1 No.c) Dol Starter - L&T - 10 HP - 1 No.d) Base Frame Kit (for Motor and Compressor) - 1 set e) Pressure Swith - 1 No.f) Pressure Gauge - 1 No. g) NRV and Pilot Fittings - 1 No. h) Delivery Tube - 1 Noi) Foundation Bolts & Anchor Fasteners - 1 Lot j) Belt Guard - 1 No.k) Refrigerator Type Air Dryer-40 cfm. capacity-1 No. l) Drain Ball Valve - 1 No.m) Air Outlet Ball Valve - 1 No.Vacuum Room & Air Compressor Room Inside Accessories:Non-Return Valves, Air Pressure Switch, Pressure Gauge, Isolation Valves, Air Filters etc., Inter connecting piping: Mild Steel Pipe of 2 with fittings |
| 431 | 6).Medical Vacuum SystemSupply, installation, testing and commissioningof Reciprocating Air Cooled Type (10 HP) RatingVaccum Pump as per following provisions.As per IS 12827 / 1987 & ISO 7396 / 1987 Specificationa) Vaccum Pump - 10 HP - 1 No.b) Electric Motor - 10 HP - 1 No.c) DOL Starter with OLR - 1 No.d) Vaccum Switch - 1 No.e) Vaccum Gauge - 1 No.f) Control Frame with Fittings - 1 No.g) Suction Scrubber - 1 No.h) V-Belts - 1 No.i) GI & MS Fittings - 1 No.j) Brass Fittings - 1 No.k) Exhaust Silencer - 1 No.i) Base Frame for Motor and Vaccum Pump - 1 setm) Pilot Line with Fittings - 1 set,Vaccum Room & Air Compressor Room Inside |
| 432 | 7). SITC of ISOLATION CONTROL VALVE: Brass Isolation Valve suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball valve of reputed make, conneced in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber O\" ring, tapion lap and etc. All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827-1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827 / 1989 & ISO 7396 / 1987 Sepecification. (i) 12 mm ball valve with O-ring Type Both End Adapter |
| 433 | ii). 15 mm ball valve with O-ring Type Both End Adapter |
| 434 | iii). 22 mm ball valve with O-ring Type Both End Adapter |
| 435 | iv). 28 mm ball valve with O-ring Type Both End Adapter |
| 436 | v). 42 mm ball valve with O-ring Type Both End Adapter |
| 437 | vi). 76 mm ball valve with O-ring Type Both End Adapter |
| 438 | 8). SITC of Area Valve Service Unit (Valve Unit): Area Valve Service Unit (Alarm & Valve Combo Unit) Area valve box with inbuilt touch screen alarm with sensor kit, NFPA Compliance product combined valve box assembly with alarm & alarm is ETL listed to UL 1069 and CSA C22.2 No 205 signal equipment.(i) 1 Gas -- VALVE -2 SERVICE-ISO (Oxygen and Vacuum) |
| 439 | (ii) 2 Gas -- VALVE -2 SERVICE-ISO (Oxygen and Vacuum) |
| 440 | (iii) 3Gas -- VALVE -3 SERVICE-ISO (Oxygen, Air 4 Barand Vacuum) |
| 441 | 9). SITC of Area Alarm Service Unit (Medical Gas Alarm Unit): Area Alarm box with touch screen alarm with sensor kit, HTM02-01 Compliance product combined with Medical Gas Alarm(i) 1 Gas -- VALVE -2 SERVICE-ISO (Oxygen and Vacuum) |
| 442 | (ii) 2 Gas -- VALVE -2 SERVICE-ISO (Oxygen and Vacuum) |
| 443 | (iii) 3Gas -- VALVE -3 SERVICE-ISO (Oxygen , Air 4 Bar and Vacuum) |
| 444 | 10). SITC of Terminal Units: DIN / BS Standard Outlet Points with from loading, inner connecting and brass body. Single press inlet with two stage process first stage for patient usage and second stage in parking mode, covered by plastic cover duly colour indicated with specific gas name and non inter changeable for other gases. The cost of materials inclduingtransport, etc., complete, as per standard specification and as directed by the Departmental Officers(i) 1 Gas -- VALVE -2 SERVICE-ISO (Oxygen and Vacuum) |
| 445 | (ii) 2 Gas -- VALVE -2 SERVICE-ISO (Oxygen and Vacuum) |
| 446 | (iii) 3Gas -- VALVE -3 SERVICE-ISO (Oxygen , Air 4 Bar and Vacuum) |
| 447 | 11). SITC of Oxygen Flow Meter made up of Brass with Humidifier Bottle Flow Meter should be back pressure compressed and should be accurate gas flow measurement with control range 0-13 litres per minute. It should meet strict permission and dumbling standard. The meter body should be made of brass materials. The humidifier bottle should be made of unbreakable polycorbonate material and auto cleavable at 134 degree centigrate. The rate includes flow meter and its accessories (silicon tube with mask). The cost of materials including transport, etc., complete as per standard specification and as directed by the Departmental Officer and as per IS 12827 / 1989 and ISO 7396 / 1987 Specification |
| 448 | 12). SITC of Ward Vaccum Unit with Gauge both mounted on a collection jar of capacity 600 ml and with a wall bracket for mounting it on the wall. The collecion jar should be made of unbreakable polycarbonate materials which is fully auto cleavable at 134 degree centigrade as per standard specification and as directed by the Departmental Officers and as per IS 12827 / 1989 and ISO 7396 / 1987 Specification. The rate includes cost of silicon hose with SS nipple on either sid |
| 449 | 13).Medical gas hose : It shall be colour coded for individual services i.e. white for Oxygen, Blue for N2O and Yellow for Vacuum, Black for air. Antistatic rubber tube should be as per ISO standards. |
| 450 | 14) SITC of Terminal Unit Console Metal Box (i) EGP 1.2mm Thk Metal Powder Coated Box with Printed Aluminium Cover Plate for Single Gas |
| 451 | (ii) EGP 1.2mm Thk Metal Powder Coated Box with Printed Aluminium Cover Plate for TWO Gas |
| 452 | (iii) EGP 1.2mm Thk Metal Powder Coated Box with Printed Aluminium Cover Plate for ThreeGas |
| 453 | (iv) EGP 1.2mm Thk Metal Powder Coated Box with Printed Aluminium Cover Plate for Four Gas |
| 454 | Schedule- A9 Replacement of Oxygen pipeline system-(ii) Surgical Block |
| 455 | 1). SITC of Medical Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling). The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg. / cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection. The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V. The pipelines installed at the various wings and floors etc., complete as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification.(i)76mm OD X 1.5mm thick |
| 456 | ii).42mm OD X 1.2mm thick |
| 457 | iii).35mm OD X 1.2mm thick |
| 458 | iii).28mm OD X 0.9mm thick |
| 459 | iv).22mm OD X 0.9mm thick |
| 460 | v).15mm OD X 0.9mm thick |
| 461 | vi).12mm OD X 0.9mm thick |
| 462 | 2.SITC of Manifolds ( without Cylinders):(i). Pressure Gauge |
| 463 | 2(ii). Oxygen manifold arrangements of 2 banks x 20 cylinder each wing with semi automatic control panel which includes contact gauge 2 Nos., outlet pressure gauge, brass heavy duty IO x regulator 2 Nos. with suitable adopter, flexible SS Hose. Mainfold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 1282-1989. Emergency alarms with illuminating display for low / high pipeline pressure and malfunctioning of system. 1) Mainfold top frame with provision for connecting 12 cylinders on right bank and 12 cylinders on left bank with high pressure interconnecting copper tubing, silver brazing, non return valve, fasteners and cylinder spport middle angle frame for claping 2 x 12 cylinders and related fasteners. The O2 manifold should with stand a pressure of 140 kg. / CM2. The installation is commissioned after testing as per standards and painted as per International Code and as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification |
| 464 | 2(iii). Oxygen manifold arrangements of 2 banks x 12 cylinder each wing with semi automatic control panel which includes contact gauge 2 Nos., outlet pressure gauge, brass heavy duty IO x regulator 2 Nos. with suitable adopter, flexible SS Hose. Mainfold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 1282-1989. Emergency alarms with illuminating display for low / high pipeline pressure and malfunctioning of system. 1) Mainfold top frame with provision for connecting 12 cylinders on right bank and 12 cylinders on left bank with high pressure interconnecting copper tubing, silver brazing, non return valve, fasteners and cylinder spport middle angle frame for claping 2 x 12 cylinders and related fasteners. The O2 manifold should with stand a pressure of 140 kg. / CM2. The installation is commissioned after testing as per standards and painted as per International Code and as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification |
| 465 | 2(iv). Supply Of Nitrous Oxide Manifold 2+2 Cylinder With Copper tail pipe, Special NRV, Distance piece, Middle frame With Individual Chain Support, Provision For Fixing Fully-Automatic Control Panel Board with the following items :• Total number for Brass block for NRV – 4 nos.• Total number for Gas pre heater – 4 nos.• Total number of Brass Block for Cylinder Valve – 4 nos.• Non Return Valve - 4 nos.• Cylinder Valve - 4 nos.• Block for regulator – 2 nos.• Double Stage & Double Gauge Regulator – 2 nos.• Middle frame with chain – 4 nos. |
| 466 | 3). SITC of Oxygen Source System:Digital Fully Automatic Oxygen Control System: 3 Source Control Panel with Primary Ist as liquid with PRS system for liquid oxygen and Secondary as Manifold. The heavy duty control panel to be provided with a flow capacity of approx 2666 LPM at 50 to 60 psi with .CE Certified, ETL Listed / Country of Orgin : Germany. |
| 467 | 4).SITC of Primary N2O Main Source System: Digital Fully Automatic Nitrous Oxide Control System: 2 Source Control Panel with Primary Ist as liquid and Secondary as Manifold. The heavy duty control panel to be provided with a flow capacity of approx 1500 LPM at 50 to 60 psi with .ETL Listed as per ISO 7396 HTM02-01 standard / Country of Orgin : Germany. |
| 468 | 5).SITC of Secondary N2O Main Source System: Supply, Installation, Testing, and Commissioning of Single Cylinder Emergency N2O arrangement using a High Flow Double Guage Single Stage Regulator and 3/4\" Control Valve with O-ring Type Adapter for quick release and adopt mechanism using N2O Terminal Unit or NIST with HP Hose,Gas Pre Heater and NRV. |
| 469 | 6).Compressed Medical Air System: Supply, installation, testing and commissioning of Compressed Air System of Reciprocating Oil Free Air Compressor Belt Driven Type 15 HP Air Compressor with following provisions. As per IS 12827 / 1987 & ISO 7396 / 1987 Specification Compressor package consists of following: a) 15 HP Air Compressor - 1 No.b) Electric Motor 10 HP - 1 No.c) Dol Starter - L&T - 10 HP - 1 No.d) Base Frame Kit (for Motor and Compressor) - 1 set e) Pressure Swith - 1 No.f) Pressure Gauge - 1 No. g) NRV and Pilot Fittings - 1 No. h) Delivery Tube - 1 Noi) Foundation Bolts & Anchor Fasteners - 1 Lot j) Belt Guard - 1 No.k) Refrigerator Type Air Dryer-60 cfm. capacity-1 No. l) Drain Ball Valve - 1 No.m) Air Outlet Ball Valve - 1 No.Vacuum Room & Air Compressor Room Inside Accessories:Non-Return Valves, Air Pressure Switch, Pressure Gauge, Isolation Valves, Air Filters etc., Inter connecting piping: Mild Steel Pipe of 2 with fittings |
| 470 | 7). Medical Vacuum SystemSupply, installation, testing and commissioning of Reciprocating Air Cooled Type (15 HP) Rating Vaccum Pump as per following provisions. As per IS 12827 / 1987 & ISO 7396 / 1987 Specification a) Vaccum Pump - 15 HP - 1 No. b) Electric Motor - 15 HP - 1 No.c) DOL Starter with OLR - 1 No. d) Vaccum Switch - 1 No.e) Vaccum Gauge - 1 No.f) Control Frame with Fittings - 1 No.g) Suction Scrubber - 1 No.h) V-Belts - 1 No.i) GI & MS Fittings - 1 No.j) Brass Fittings - 1 No.k) Exhaust Silencer - 1 No.i) Base Frame for Motor and Vaccum Pump - 1 setm) Pilot Line with Fittings - 1 set,Vaccum Room & Air Compressor Room Inside |
| 471 | 8). SITC of ISOLATION CONTROL VALVE: Brass Isolation Valve suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball valve of reputed make, conneced in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber O\" ring, tapion lap and etc. All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827-1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827 / 1989 & ISO 7396 / 1987 Sepecification(i) 12 mm ball valve with O-ring Type Both End Adapter |
| 472 | ii). 15 mm ball valve with O-ring Type Both End Adapter |
| 473 | iii). 22 mm ball valve with O-ring Type Both End Adapter |
| 474 | iv). 28 mm ball valve with O-ring Type Both End Adapter |
| 475 | v). 42 mm ball valve with O-ring Type Both End Adapter |
| 476 | vi). 76 mm ball valve with O-ring Type Both End Adapter |
| 477 | 9). SITC of Area Valve Service Unit (Valve Unit): Area Valve Service Unit (Alarm & Valve Combo Unit) Area valve box with inbuilt touch screen alarm with sensor kit, NFPA Compliance product combined valve box assembly with alarm & alarm is ETL listed to UL 1069 and CSA C22.2 No 205 signal equipment.(i) 1 Gas -- VALVE -2 SERVICE-ISO (Oxygen) |
| 478 | (ii) 2 Gas -- VALVE -2 SERVICE-ISO (Oxygen and Vacuum) |
| 479 | (iii) 3Gas -- VALVE -3 SERVICE-ISO (Oxygen, Nitrous Oxide,Air 4 Barand Vacuum) |
| 480 | 10). SITC of Area Alarm Service Unit (Medical Gas Alarm Unit): Area Alarm box with touch screen alarm with sensor kit, HTM02-01 Compliance product combined with Medical Gas Alarm(i) 1 Gas -- VALVE -2 SERVICE-ISO (Oxygen ) |
| 481 | (ii) 2 Gas -- VALVE -2 SERVICE-ISO (Oxygen and Vacuum) |
| 482 | (iii) 3Gas -- VALVE -3 SERVICE-ISO (Oxygen , Nitrous Oxide,Air 4 Bar and Vacuum) |
| 483 | 11). SITC of Terminal Units: DIN / BS Standard Outlet Points with from loading, inner connecting and brass body. Single press inlet with two stage process first stage for patient usage and second stage in parking mode, covered by plastic cover duly colour indicated with specific gas name and non inter changeable for other gases. The cost of materials inclduing transport, etc., complete, as per standard specification and as directed by the Departmental Officers(i) Oxygen Gas Terminal Unit with Suitable Probe. |
| 484 | (ii) N2O Gas Terminal Unit with Suitable Probe. |
| 485 | (iii) MA4 Air Gas Terminal Unit with Suitable Probe. |
| 486 | (iv) Vacuum Gas Terminal Unit with Suitable Probe. |
| 487 | 12). SITC of Oxygen Flow Meter made up of Brass with Humidifier Bottle Flow Meter should be back pressure compressed and should be accurate gas flow measurement with control range 0-13 litres per minute. It should meet strict permission and dumbling standard. The meter body should be made of brass materials. The humidifier bottle should be made of unbreakable polycorbonate material and auto cleavable at 134 degree centigrate. The rate includes flow meter and its accessories (silicon tube with mask). The cost of materials including transport, etc., complete as per standard specification and as directed by the Departmental Officer and as per IS 12827 / 1989 and ISO 7396 / 1987 Specification |
| 488 | 13). SITC of Ward Vaccum Unit with Gauge both mounted on a collection jar of capacity 600 ml and with a wall bracket for mounting it on the wall. The collecion jar should be made of unbreakable polycarbonate materials which is fully auto cleavable at 134 degree centigrade as per standard specification and as directed by the Departmental Officers and as per IS 12827 / 1989 and ISO 7396 / 1987 Specification. The rate includes cost of silicon hose with SS nipple on either side |
| 489 | 14).Medical gas hose : It shall be colour coded for individual services i.e. white for Oxygen, Blue for N2O and Yellow for Vacuum, Black for air. Antistatic rubber tube should be as per ISO standards.. |
| 490 | 15) SITC of Terminal Unit Console Metal Box (i) EGP 1.2mm Thk Metal Powder Coated Box with Printed Aluminium Cover Plate for Single Gas |
| 491 | (ii) EGP 1.2mm Thk Metal Powder Coated Box with Printed Aluminium Cover Plate for TWO Gas |
| 492 | (iii) EGP 1.2mm Thk Metal Powder Coated Box with Printed Aluminium Cover Plate for FiveGas |
| 493 | 16. SITC of Anesthetic Gas Scavenging System:(i) Duplex Anesthetic Gas Scavenging System (AGSS) Duplex blower type with 1 working + 1 standby, AGSS duplex Remote switch flush type and AGSS transfer and hose(3nos) |
| 494 | 16. (ii) AGSS Duplex remote switch |
| 495 | 16. (iii) AGSS Gas Outlet Points |
| 496 | Schedule- A 10 -(I) Fire Fighting System |
| 497 | A. FIRE PUMPHOUSE EQUIPMENTS1. MAIN PUMPSET:Supply and Installation of Electrical 3 phase 415v , 50Hz motor driven Horizontal End Suction Top Discharge Centrifugal pumpset with bronze impeller, cast iron body rated 137 Cu.m/hr at 70MWC 3000 RPMWithElectrical motor of Suitable 75HP, TEFC andcomplete with all accessories.For Hydrant System |
| 498 | 2. STANDBY PUMPSET:Supply and Installation of Diesel engine driven horizontal end suction centrifugal pumpset with bronze impeller, cast iron body rated 137 Cu.m/hr at 70 MWC.The pump should have RPM between 2150 complete 90HP with all accessories |
| 499 | 3. JOCKEY PUMPSET:Supply and Installation of Electrical 3 phase 415v , 50Hz motor driven horizontal Side suction Top Discharge centrifugal pumpset rated 10.8Cu.M/hr. at70MWC, 2900-3000RPM WithElectrical motor of Suitable 10HP, TEFC and complete with all accessories For Hydrantsystem. |
| 500 | 4. FIRE PUMP PANEL:a). Autostart panel for theDiesel engine complete auto/ manual switch, indication lamps protective fuses with battery charger, suitable of working on 230 V, AC, single phase, enclosure being vermin & dust proofb). Supply and Installation of MCC with Star & Delta starter for the electrical motor driven pumpset / DOL starter Jockey pumpset complete with isolator switch, voltmeter, ammeter manual / auto mode switch, indicating lamps etc., |
| 501 | 5. Supply and Installation of Cable, Earthing, Cable TrayFor the Pumps, Pressure Switchs, Etc.,a). \"3.5 C x 70 sq.mm Al.Armoured Cable |
| 502 | b). 3.5 C x 16 Sq.mm Al.Armoured Cable |
| 503 | c). \"3 C x 1.5 Sq.mm Copper armoured Cable |
| 504 | d). \"10 C x 2.5 Sq.mm Copper armoured Cable |
| 505 | e). Earthing of the Electrical Motor / MCC(25 x 6 cu.) |
| 506 | f). Cable tray with supports (Tray Size 150mm Width x 75mm Height) |
| 507 | 6. Supply and Installation of M.S Pipe 200NB above as per IS 3589 , 150NB and Below as per IS 1239With Heavy Duty Fittings including cutting,welding and testing to the Following Specifications.a). 200 NB, 6.35 mm thick MS -C CLASS |
| 508 | b). 150 NB,5.5 mm thickMS -C CLASS |
| 509 | c). 100 NB, 5.5 mm thick MS -C CLASS |
| 510 | d). 80 NB,4.8 mm thick MS- C CLASS |
| 511 | e). 50 NB,4.8 mm thick MS- C CLASS |
| 512 | 7. a).Supply and installation of Y strainer of 150NB with necessary grooved end, nut, bolts & washers, painting, etc. complete as required |
| 513 | 7. b). 80mm dia Y Strianer. |
| 514 | 8. Supply and installation of Foot valvewith necessary grooved end, nut, bolts & washers, painting, etc. complete as requireda). 200mm dia |
| 515 | b). 80mm dia |
| 516 | 9. Priming tank 1000ltrs capacity |
| 517 | 10. Supply and Installation of CI Butterfly Valve PN 16Rating with Matching flanges,gasket,bolts and nutsa). 200 NB - Lever operated |
| 518 | b). 150 NB - Lever operated |
| 519 | c). 50NB -Lever operated |
| 520 | d). 100 NB - Lever operated |
| 521 | 11). Supply and Installation of CI Non-Return Valve with Matching flangesa)150 NB |
| 522 | b)100 NB |
| 523 | c) 50 NB |
| 524 | 12).Supply & installation ofPressure switch,Pressure gauge, Gunmetal Ball Valve, NRVFor Test Array Arrangement including Supporting Arrangement. a)Pressure switch 0-12 bar |
| 525 | b)Pressure guage 0-12 bar |
| 526 | c) 15mm Ball Valve |
| 527 | d) 25mmBall valve |
| 528 | e) 25mm NRV |
| 529 | 13). Air Release Valve size & specification should be confrimed by vendor |
| 530 | 13). a.Drain Valve size & specification should be confrimed by vendor.. |
| 531 | 14) Painting of the abovegroundMS pipes / valves with one coat of metal primer and two coat of fire red enamel paint of approved quality |
| 532 | 15) Supply and Installation of four way fire brigade inlet with 150NB Butterfly valve with matching flanges |
| 533 | B. FIRE HYDRANT SYSTEM FOR PROPOSED & EXISTING BUILDING:-1. Above Ground MSERWpipes as perIS:3589/1239,including Heavy class fittings.a) 150 NB, Heavy Class - C |
| 534 | b). 100 NB, Heavy Class - C |
| 535 | c). 80 NB, Heavy Class - C |
| 536 | 2. Under Ground MSERWpipes as perIS:3589/1239, Heavy class including fittings.Coating & Wrapping Materials for underground MS Pipes 200mm |
| 537 | 3. HYDRANT COMPONENTS:a). Doubleheaded, Hydrant valve, oblique type 63 mm dia with flanged inlet with blank cap & chain all are should be considered SS as per standard with ISI Mark |
| 538 | b). Branch Pipe, short with 63 mm dia instantaneous inlet hexagonal nozzle should be considered SS as per standard with ISI Mark |
| 539 | c). R.R.L.hose of 63mm dia SS Coupling as per IS:636 with ISI Mark 15 Mts.long |
| 540 | d). Hydrant box made of 18 G MS Sheet Size: 750 x 600 x 250 with glass fronted door, painted red outside, white inside |
| 541 | 4. Supply,installation,testing and commisioning of fire hose reel(as per ISI) wall mounted,swinging type 18 SWG MS sheet,fitted with 20 mm dia into 36 m long, high pressure hose with 5 mm outlet GM nozzle with shut off valve(IS: 884) includes stop cock and chrom plated nozzle with all nececssery fixing materials complete. |
| 542 | 5. 150NB Non Return Valve with matching flanges,Gasket,bolts and nuts |
| 543 | 6. CI Butterfly valve as per BS:5155 with matching flanges,Gasket,bolts and nuts150 NB - lever Operated |
| 544 | 7. 25NB Pressure Relief with isolation valve |
| 545 | 8. Painting of the aboveground MS pipes / valves with two coats of primer and two coats of fire red enamel paint of approved quality |
| 546 | 9. Civil 3 Nos. pumps foundation work and pipe line scoffolding charges. |
| 547 | 10. civil work core cutting. |
| 548 | 11. Supports made of MS \"C\" channel, Ms plate, angle and anchor fastener \"U\" bolts etc., for above |
| 549 | C. ADDRESSABLE FIRE ALARM SYSTEMS1. Analogue addressable micro Process - controlled Fire Alarm Control Panels with interfacing box, capable of being to the central monitoring System, to monitor and integrated the following quantity of accessories like detectors, MCP\"s/hooters/control modules, Fault Isolation Modules, hooters, response indicators,fire/fault indicators, audio-visualsignals, central processing units, , complete with LCD display( (640 nos. of characters 8 lines min), zone indicating LEDs as per the detailed specification: complete with Battery backup for 48 hours in standy mode and 30 minutes in alarm condition. The system should be capable of detecting fire within 3secs as per UL 9th edition/FM/EN-54 approval with charger for each panel.Each loop should provide with minimum 252 detectors and devices. Fire panel should be RS-485 communication port and integrate with other fire panel and Repeater panel2 Loop panel |
| 550 | 2. Supply, installation, fixing, testing and commissioningof Analog Addressable Smoke detector (photo) with base, Junction box and other accessories as required and Detectors shall be UL listed,(ON CEILING) |
| 551 | 3. Supply, installation, fixing, testing and commissioningofAddressable monitor module |
| 552 | 4. Supply, installation, fixing, testing and commissioningofAddressable control module |
| 553 | 5. Hooter with Control Relay module and storb light with minimum 85 db audiable and control relay module, power supply units etc @ 3m for Audible annunciation and 75cd flashintg at 1 Hz for visual indicationwithControlModule. |
| 554 | 6. Manual call points pull stations of approved make with NO/NC contacts slim type and projecting out from the surface of enclosurewith glass suitable for addressable function |
| 555 | 7. 2C 1.5 sq mm armoured FRLS cables in celing with suitable clamps and screws (RED colour) |
| 556 | D. P.A. SYSTEM1. Supplying, installing, testing and commissioning of 4-zone selector P.A. console with mounting racks and other accessories. |
| 557 | 2. Supplying, installing, testing and commissioning of solid state Amplifier of 480W RMS out put in rack, including necessory control wires, jacks etc. complete. |
| 558 | 3. Supplying, installing, testing and commissioning of 12W wall mounted type speakers with mounting fixtures |
| 559 | 4. Supplying, installing, testing and commissioning of 2 core of 1.5 sq. mm, Annealed tin copper conductor, PVC Sheathed unarmoured FRLS Cable. |
| 560 | 5. Supply, Installation, Testing & Commissioning of 4 Zone Call Station with Gooseneck Microphone |
| 561 | 6. Excavating trenches by mechanical/manual means of required width for pipes, cables etc., including excavation for sockets, and dressing of sites, ramming of bottoms, for all depths, including getting out the excavated soil, and then returrning the soil as required, in layers not exceeding 20 cm depth, including consolidating each deposited layers by ramming, watering etc., and disposing of surplus excavated soil as directed, within a lead of 50 mtrs for laying of Pipe, cables etc., exceeding 80mm dia but not exceeding 300 mm dia |
| 562 | 7. Demolishing of cement concrete/ road cutting manually by Mechanical means including disposal of materials within 50 mtrs lead as per direction of Engineer- in-charge and back filing with nominal concreate 1:3:6 or richer mix (including equivalent design mix) |
| 563 | E. Supply and installation of Signage system1). \"FIRE EXIT\"(AUTO GLOW)-SINGLE SIDE-FOR FIRE EXIT DOORS-150x300 mm |
| 564 | 2. \"DIRECTIONAL EMERGENCY EXIT\" (AUTO GLOW-DOUBLE SIDE-150x300 MM-FOR INTERNAL AREAS |
| 565 | 3. \"EXTINGUISHER\" SIGNAGES-(AUTOGLOW)-WITH SUSPENSION CHAIN-150x300mm-double side with suspension chain(SS) |
| 566 | 4. \"MCP SIGNAGES\"-(AUTOGLOW)-WITH SUSPENSION CHAIN-150x300mm-double side with suspension chain(SS) |
| 567 | Schedule- A 10 -Fire Fighting System (II) Construction of Low Level Reservoir |
| 568 | 1.01. Earthwork excavation by manually / mechanically in ordinary soil, sand, clay, mixed wtih roots, boulders, weighing individually less than 250 kg. debris, rubbish etc., for foundation of Low Level Reservoir and wherever required, including dressing of sides, ramming of bottom as specififed under relevant schedules and drawings, depositing the excavated earth within a lead of 50 m all as directed including shoring, shuttering, labour, tools, tackles, equipments, fuel, etc., complete.a. Up to 1.5 m depth |
| 569 | b. below 1.5 m depth |
| 570 | c. Dewatering in the excavated area by pumping the water from foundation trench and wherever required using 10 HP motor as per site condition and as directed including pumping the water carefully without affecting the near by site including all labour, tools, plants, equipment, transport, fuel etc., complete. |
| 571 | 1.02 Providing and laying of Plain Cement Concrete of mix 1:4:8 in volumetric proportion (1 cement : 4 CS sand : 8 Hard granite graded stone aggregate 40 mm nominal size) for levelling course of Low Level Reservoir and wherever required including mixing, transporting, placing, ramming, consolidating, curing all as per relevant specifications, drawings and as directed including all labour, cost of cement, materials, tools, equipments, etc, complete.Note:The cost of centering and shuttering will be measured and paid seperately under relevant item of this schedule. |
| 572 | 1.03 Preparing the top surfaces of PCC levelling course, side walls of LLR and wherever required and providing plastering in cement mortar 1:5 (1cement : 5 CS sand) 20 mm thick, before laying of tar felt, to the required finish curing etc., all as directed at site of work including all labour, cost of cement, materials, tools, equipment’s, scaffolding, etc., complete. |
| 573 | 1.04 Providing and laying 3 layer of water proofing treatment with bitumen felt over the plastered levelling course, side walls of LLR and wherever required consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS:702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) all as directed at site of work including all labour, cost ofmaterials, tools, equipment’s, scaffolding, etc., complete |
| 574 | 1.05 Preparing the top surfaces of after laying tar felt LLR flooring area, side walls of LLR and wherever required and providing plastering in cement mortar 1:5 (1 cement : 5 CS sand) 20 mm thick, to the required finish curing etc., all as directed at site of work including all labour, cost of cement, materials, tools, equipment’s, scaffolding, etc., complete. |
| 575 | 1.06 Providing and laying RCC of mix in1:1.5:3 (1 cement :1.5 coarse sand : 3 Hard granite graded stone aggregate 20 mm nominal size) in volumetric proportions up to plinth level, for base slab / side wall / beams / top cover slab of LLR and wherever required including mixing, transporting, placing, ramming, consolidating, excluding the cost of centering, shuttering, finishing and reinforcement all as per relevant specification and as directed including all materials,cement, labour, curing, tools, equipments, transport, fuel, etc., complete.Note:1.The cost of centering and shuttering will be measured and paid seperately under relevant item of this schedule.2. Supplying, fabricating and fixing in position of reinforcement steel will be measured paid seperately under relevant item of this schedule. a. LLR Base Slab |
| 576 | b. LLR side walls |
| 577 | c. LLR Beams |
| 578 | d. LLR top cover slab |
| 579 | 1.07Providing Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 for foundation up to plinth in CM 1:4 (1 cement : 4 CS sand) all as directed at site, including all labour, cost of cement, materials, curing,tools, tackles, equipments, scaffolding, transport, fuel, etc, complete. |
| 580 | 1.08 Providing centering and shuttering including strutting, propping etc., with steel shutters / spans /propsand removal of form for foundations, footings for mass concrete all as directed, including labour,tools,tackles, equipments, scaffolding, transport etc, complete.a. For levelling course |
| 581 | b. For base slab |
| 582 | c. For Side Walls |
| 583 | d. For Beams |
| 584 | e. For Roof Slab |
| 585 | 1.09 Preparing the surfaces of LLR Flooring & Roof Slab and providing plastering in cement mortar 1:3 (1cement : 3 CSsand) 20 mm thick and providing ISI certified water proofing material in proportion recommended by the manufaturer/Integral water proofing liquid admixture conplast (or) equivalent(160ml /50kg of cement and with neat cement slurry to the required finish, curing etc., all as directed at site of work including all labour, cost of cement, materials, tools, equipments, scaffolding, fuel, etc., complete. |
| 586 | 1.10 Preparing the surfaces of LLR and providing plastering in cement mortar 1:3 (1cement : 3 CS fine sand) with 12 mm thick with ISI certified water proofing material in proportion recommended by the manufacturer/ withIntegral water proofing liquid admixture conplast (or) equivalent(160ml /50kg of cement including finishing with neat cement slurry to the required finish, curing etc., all as directed and wherever required including all labour, cost of cement, materials, tools, equipments, scaffolding, fuel, etc., complete. a. For RCC Side Walls - inside |
| 587 | b. For Beams |
| 588 | C. For RCC Side Walls -outside |
| 589 | 1.11 Providing plastering for the Brick work with cement mortar 1:5 (1cement : 5 CS fine sand) 12 mm thick with providing ISI certified water proofing material / withIntegral water proofing liquid admixture conplast (or) equivalent(160ml /50kg of cement to the required proportioning as per the manufacturer specificaitons, to the required finish, curing etc., all as directed at site of work including all labour, cost of cement, materials, tools, equipments, scaffolding, fuel, etc., complete. |
| 590 | 1.12 Refilling with available excavated earth in the sides of foundations etc., and wherever required in layers not exceeding 200 mm consolidating the deposited layer by ramming and watering as directed including all labour, tools, equipments, etc, complete. |
| 591 | 1.13 Supplying and fixing of orange colour safety foot rest inside the walls of LLR with minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 CS sand : 6 graded stone aggregate 20 mm nominal size) complete as per design all as directed including all labour, cost of cement, tools, equipments, etc, complete. |
| 592 | 1.14 Providing, casting and fixing in postion of RCC precast Manhole Cover slab 75 mm thick of required size in cement concrete 1:1.5:3 (1 cement :1.5 CS sand : 3 graded stone aggregate 20 mm nominal size) in volumetric proportion including finishiing the exposed surface, in cement mortar 1:3 (1 cement : 3 CS sand) 6 to 10 mm thick with a floating coat of neat cement punning all as per relevant specifications and as directed at site including cost of cement, mixing, transporting, placing, ramming, consolidating etc, including shttering, struting, curing, equipment, tools etc., complete. Note:Supplying, fabricating and fixing in position of reinforcement steel will be measured paid seperately under relevant item of this schedule. |
| 593 | 1.15 Providing and fixing of PVC pipe 100 mm dia with Cowl / Airvent or nearest size as availablein the market all as per relevant specification and as directed including all materials, labour, tools, equipment, transport, fuel, etc., complete. |
| 594 | 1.16 Supplying, fabricating and placing in position Fe 500/550 D grade or more HYSD TMT steel bars as reinforcement for all RCC works including handling, cutting, bending and tying in position with 1.25 mm dia black annealed steel binding wire including placing all as per relevant specification and as directed including all materials, labour, tools, equipment, transport, fuel, etc., complete. Note:The rate shall be inclusive of cost of reinforcement steel, binding wire and fabrication charges etc., complete. Binding wire will not be measured for payment purpose. |
| 595 | 1.17 Preparing the surface of external walls of LLR and applying two coats of water proof cement paint of approved brand and shade wherver required over a priming coat with cement primer all as directed including all labour, cost of cement, materials, tools, brushes, tackles, equipments, scaffolding etc., complete. |
| 596 | 1.18 Loading, transporting and dumping the surplus excavated earth outside the port premises within a lead of 3 km and all as directed including all labour, cost of cement, transport, tools, equipments, fuel, etc., complete. Note: 1. The tenderer shall maintaintrip sheets in triplicate in Port’s approved format at his own cost for the quantity of earth transported. 2. Payment will be based on the lorry cubical content. 20% deduction for voids to be made. |
| 597 | Schedule- A 10 -Fire Fighting System (III) Construction of Pump Room |
| 598 | 1.Dismantling / demolishing the existing brick work in cement mortar by manually /mechanically tothe required level, size andshape wherever requiredwithoutdamaging the structures nearby including stacking of serviceable materials, collectingand depositing the debris within a lead of 50m for disposal all as per relevant specification and as directed at site of workincluding all labour,tools, tackles, equipments, transport, fuel, scaffoldingetc., complete |
| 599 | 2. Dismantling the existing Plain cement concrete in lean mix to the required level, size and shape wherever required without damaging the nearby structures if any, and depositing the debris within a lead of 50m for retransportation and disposal all as per relevant specification and all as directed at site of work including all labour, tools, equipment, fuel, transport, etc., complete. |
| 600 | 3.Earth work excavationby mechanical / manual means in ordinary soil, sand, clay mixed with roots, boulders weighing individually less than 250 Kg, debris, rubbish etc., as existing at site of work up to 1.5m depthforfoundationsandwhere ever required all as directed at site, including dressing of sides ramming of bottom all as per relevant specificationand as directed at site including depositing the excavated earth within a lead of 50 m for transportationincluding shoring, strutting if required, including all labour, tools, tackles, equipments, fuel etc., complete. |
| 601 | 4.Providing and laying plain cement concrete of mix 1:4:8(1 Cement: 4 CS sand : 8 hard granite graded stone aggregate of 40 mm nominal size) in volumetric proportions for levelling course in foundations and wherever required all as per relevant specification and as directed at site including mixing, transporting, vibrating, placing, ramming, consolidating, curing, shuttering, dewatering if any etc., including all materials, cement, labour, tools, plants, equipments,etc., complete |
| 602 | 5. Providing Brick workwith common burnt clay(non modular) bricks of class designation 7.5in cement mortar 1:4 ( 1 Cement : 4 CS sand) for foundation and wherever required all as as per relevant specication andas directed at site including all materials, cement,labour, curing,tools, scaffolding, equipments, transport, fuel ,etc., complete |
| 603 | 6. Providing and laying ReinforcedCement Concrete of mix 1:1.5:3 (1 Cement: 1.5 CS sand : 3hard granite graded stone aggregate of 20 mm nominal size) in volumetric proportions for Plinth beam, all as per relevant specifications and as directed including cost of shuttering, mixing, transporting, placing, vibrating,finishing, curing etc.,including all materials, labour, strutting, tools, plants, equipments, machinery, fuel, etc., complete.Note:Steel reinforcement will be measured and paid for separately under relevant item. |
| 604 | 7. Supplying and filling withcrushed stone sandfor bedding to arequired depth in basementandwhereever required including ramming, wateringconsolidation all as per relevant specificationand as directed at siteincluding all labour, materials, tools, equipments, fuel etc., complete |
| 605 | 8. Providing Brick workwith common burnt clay(non modular) bricks of class designation 7.5in cement mortar 1:5 ( 1 Cement : 5 CS sand) forsuper structure and wherever required all as as per relevant specication andas directed at siteincluding all materials, cement,labour, curing,tools, scaffolding , equipments, transport, fuel etc., complete. |
| 606 | 9. Providing and laying Reinforced cement concrete of mix 1:1.5:3 (1 cement: 1.5CS sand : 3 hard granite graded stone aggregate of 20 mm nominal size) in volumetric proportions for RCC lintel all as per relevant specifications including scaffolding, centering, shuttering, mixing, transporting, placing, vibrating, curing all as directed at site of work including cement, all labour, materials, equipments, tools, plants, fuel, etc., complete.Note: Supplying and fabrication of steel reinforcement will be measured and paid separately under the relevant item. |
| 607 | 10. Providing and laying Reinforced cement concrete of mix 1:1.5:3 (1 cement: 1.5 CS sand : 3 hard granite graded stone aggregate of 20 mm nominal size)in volumetric proportions for R.C.C sunshades all as per relevant specifications and as directed at site of work including scaffolding, centering and shuttering, mixing, transporting, placing, vibrating, curing including all labour, cost of cement, materials, Cement, equipments, tools, plants, fuel, etc., complete.Note: Supplying and fabrication of steel reinforcement will be measured and paid separately under the relevant item. |
| 608 | 11. Providing Reinforced cement concrete of mix 1:1.5:3 (1 cement : 1.5 CS sand : 3 hard granite graded stone aggregate of 20 mm nominal size) in volumetric proportions for R.C.C roof beam all as per relevant specifications, and as directed at site of work including scaffolding, centering and shuttering, mixing, transporting, placing, vibrating, curing, including all labour, cost of cement, materials, Cement, equipments, tools, plants, fuel, etc., complete.Note: Supplying and fabrication of steel reinforcement will be measured and paid separately under the relevant item. |
| 609 | 12.Providing and laying Reinforced cement concrete of mix 1:1.5:3 (1 cement : 1.5 CS sand: 3 hard granite graded stone aggregate of 20 mm nominal size) in volumetric proportions for R.C.Croof slaball as per relevant specifications and as directed at site of work including scaffolding, shuttering, centering, mixing, transporting, placing, vibrating, curing, including all labour, cost of cement, materials, Cement, equipments, tools, plants, fuel, etc., complete. Note: Supplying and fabrication of steel reinforcement will be measured and paid separately under the relevant item. |
| 610 | 13. Re-filling with available excavated earth (excluding boulders, rubbish, debris etc.,) in sides of foundationand wherever requiredin layers not exceeding 200mm in depth all as perrelevant specification and as directed at site including consolidating the deposited earth in layer by ramming and wateringincluding all labour, cost of cement,tools, equipments, etc., complete. |
| 611 | 14.Providing and laying Plain Cement Concrete of mix 1:1.5:3 in volumetric proportion (1 Cement: 2CS sand: 4hard granite graded stone aggregate of 20 mm nominal size) for Grano flooring with 40mm thick forfloor area concrete and wherever required, including necessary form work, shuttering,strutting, mixing, transporting, placing, consolidating,neat cement punning and making thread lines, curing etc., including all as directed at site of work, including all labour, cost of cement, cement, materials, equipments, tools, plants, fuel, scaffolding, equipments etc., complete. |
| 612 | 15.Preparing the surfaces of ceilingand plastering in CM 1:3, (1 cement : 3 C.S. sand) 6 to 10 mm thickto the required finish wherever required , curing all as per relevant specifications and as directed at site including all materials, cement, labour, tools, equipment,scaffolding, fuel etc., complete. |
| 613 | 16).Providing and fixing in position First Class country wood (SAL/ PADAUK )wrought main frames of finished size 95mm x 58mm for doors with necessary M.S. hold fasts(40x5mm) 400mm (overall length) long / clamps fixed suitably to the masonry / concrete including cutting pockets and grouting with P.C.C.1:3:6 ( 1 Cement : 3 CS sand : 6 Hard granite graded stone aggregate of 20mm nominal size) etc,. and applying two coats of oil type wood preservatives of approved brand and manufacture all as directed at site of work including all labour, cost of cement,materials, tools, equipments,etc., complete. |
| 614 | 17).Providing and fixing second class teak wood35mm thick panelled shuttersframe for doors and fixing with butt hinges of required size with necessary screws, including panelling 16mm tk with single leaves / double leaves all complete as per direction of Engineer-in-charge / as per chennai port civil engineering manual and drawing (amended )including all labour, cost of cement, materials, tools, equipments,etc., complete. Note:- Butt hinges with necessary screws shall be paid separately. |
| 615 | 18. Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Two and half track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (65mm & above) x (40mm & above) & glazed sash (25mm & above) x (50mm & above) & fly screen sash (18mm & above) x (40mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre). Note: Glass area will be measured and paid separately as per relevant BoQ. |
| 616 | 19.Supplying, fabricating and placing in positionHYSD (Fe 500/550 grade) TMT steel bars as reinforcement for all RCC works wherever required, including handling, cutting, bending and tying with 1.25mm dia black annealed steel binding wire including placing, all as per relevant specification, drawings and as directed,including all materials, labour, tools, equipment, transport, fuel, etc., complete.Note:1.The rate shall be inclusive of cost of reinforcement steel, binding wire and fabrication charges etc., complete. Binding wire will not be measured for payment purpose. |
| 617 | 20. Preparing the surfaces of walls and plastering in cement mortar 1:5 (1 cement : 5 CS sand), 12mm thick to the required finish all as directed at site of work, including cement and other materials, labour, tools, equipments, scaffolding, curing etc., complete. |
| 618 | 21. Supplying, fabricating and fixing M.S Grills of required pattern in frames of windows / openingsMSFlats, square orround bar etc., including priming coat with approved steel primerscaffolding all as directed at site of work, including all materials cost ofcement, labour, tools, transport , fuel, welding charges etc., complete. |
| 619 | 22.Preparing the surface of interior wallsand applyingwith Two coats of premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic compound) content less than 50 grams/ litre of approved brand and manufacture including applying addtional coats wherever required to achieve even shade and colourincluding one coat of primer (Asian/Berger or equivalent)on new wallswherever necessary all as directed at site of work including all labour, cost ofmaterials, tools, scaffolding, brushes, equipments,etc., complete. |
| 620 | 23.Preparing the surface ofexterior walls andpainting ( twoor more coat applied @ 1.67 lit / 10sqm over including priming coat of exterior primer applied @ 2.20kg/10sq.m) coats ofAcrylic smooth exterior paint of required shade including one coat of primer (Asian/Berger or equivalent)on old/ new wallswherever necessary all as directed at site of work including all labour,materials, tools, scaffolding, brushes, equipments,etc., complete. |
| 621 | 24. Preparing the surfaces of newwooden membersand applying with two or more coats over an under coat of suitable primer shade of synthetic enamel paint (Asian / Berger / Dulux or equivalent)of approved colourto give an even shade and finish all as directed at site of work including all labour, costmaterials, tools, tackles, equipments, brushes, scaffolding etc., complete.NOTE:1. Necessary painting co-efficient shall be allowed as per Ch.P.A. engineering manual.2.The above quantity is inclusive of painting co-efficient |
| 622 | 25. Preparing the surfaces of Ceilingand applyingtwocoatsofwhite washing using Lovelycem or equivalentto give an even shade all as directed at site of work wherever required including all labour,scaffolding, materials, tools, tackles,equipments, brushes, etc. complete. |
| 623 | 26. Providing and fixingAnodized aluminium fittings (AC 10 grade as per IS:1868)to the door etc., with necessary screws allas directed at site including allmaterials, labour, tools, screws, equipments etc., complete.26. a).Aldrop 250 mm long |
| 624 | 26(b). Tower bolt 150 x 10mm long |
| 625 | 26(c ). Butt hinges 125mm |
| 626 | 26(d ). Anodised aluminium hanging type door stopper - Single Rubber stopper |
| 627 | 26( e).Hooks and eyes 100mm long |
| 628 | 27. Preparing the surfaces on top of the roofor wherever required and Providing plastering in CM 1:3, 20 mm thick (1 cement:3CS sand) inTerrace portion withIntegral water proofing liquid admixture conplast (or) equivalent(160ml /50kg of cement or as equivalent all as per manufacturer specification all as per relevant specifications and as directed at site of work including curing, cement,water proofing admixture, all materials, labour, tools, equipments,etc., complete |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail