| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level 1:2:4 (1 cement:2 coarse sand(zone-Ill) derived from natural sources:4graded stone aggregate 20mm nominal size derived from natural sources) |
| 2 | Brick work with non modular flyash bricks conforming to IS:12894, class designation10 average compressive strength in super structure above plinth level up to floor V level in Cement mortar1:6(1cement:6Coarsesand) as per approved sample |
| 3 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 4 | For chajja |
| 5 | For lintel |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete upto plinth level and above plinth level , Thermo-Mechanically Treated bars of grade Fe-500D or more, lintel, chajja |
| 7 | Providing and constructing concrete block masonry using 150x200x400 mm solid core compact concrete block (Grade C – 50Kg/Cm2 ) in CM 1:6 including all scaffolding, curing, etc. complete For walls |
| 8 | Reinforced cement concrete work in lintel beams, chajja above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources) |
| 9 | For lintel and chajja |
| 10 | Providing and fixing in position 30mm thick factory made sandwiched puf panels between two Engineered sheets of precoated profiles sheet of 0.45mm (+0.50%) with plain on one side and corrugated on the other side both the sides total coated thickness with zinc coating 120grams per sqm as per IS:277, in 240mpa steel grade 57 microns epoxy primer on both side of the sheet and polymer tp coat 15-18microns, sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation .The sand witch panel core shall consist of 50mm thick puf of density not less than 40 kg/ per cum (+/-2).Fixing operations of wall panels shall be completed in all respect as per drawings and specifications and under the overall direction of the Engineer incharge |
| 11 | Providing Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster |
| 12 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (Asian Tractor / Jonson Nicholson / Berger) |
| 13 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface Water thinnable cement primer |
| 14 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats (Asian Tractor / Jonson Nicholson / Berger ) |
| 15 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (Asian Tractor / Jonson Nicholson/Berger) |
| 16 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, etc. complete. for window angle , roof purlins, base plate, and steel stair case |
| 17 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. (Asian Tractor / Jonson Nicholson / Berger) |
| 18 | 12.5mm thick square edge PVC Laminated Gypsum t tile of size595x595mm, made of Gypsum plaster board manufactured from natural gypsum asperIS2095partIand laminated with white0.16mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the backside metalized polyester film so as to make the tile a completely sealed unit. |
| 19 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm |
| 20 | Providing and fixing aluminium work for, windows with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge.(Glazing, paneling and dash fasteners to be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 21 | For shutters of doors, windows including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 22 | Providing and fixing glazing in aluminium door, window, shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) plain glass |
| 23 | Supplying and fixing with close nit SS mesh as per approved sample for aluminium shutters |
| 24 | Supplying and fixing star lock to aluminium shutters as per approved sample |
| 25 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm M.S. gusset plates at the junctions and corners all necessary fittings complete, including applying a priming coat of approved steel primer Using M.S. angels 40x40x6mm for diagonal braces |
| 26 | Providing and fixing precoated galvanized steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete tiled shaped as per approved sample for roof |
| 27 | Demolishing mud phaska in terracing and disposal of material within 50 metres lead |
| 28 | Supplying of fixing 150 mm dia half cut PVC pipes (4Kg/cm2 – ISI – Finolex/Supreme/Kisan/Prince) with necessary over laps and silicon sealant wherever necessary with required slope |