| 1 | Schedule-A (BR Work) |
| 2 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises completed all as specified and as directed by Engr-in-Charge. |
| 3 | Demolition of cement concrete of any description as in ground floor and paving exc 15 cm thickness(below or above ground level) all as directed by Engr in charge |
| 4 | M&L for pre cast Kerb stone with plain fair faces300x150x300 mm depth of PCC 1:1 ½ :3of shape as approved incl all excavation, embedding in ground and removing surplus spoil upto 50 Mtr distancecompleted all as specified and as directed by Engr-in-Charge. |
| 5 | M&L for sand filling under floors or in foundations incliding watering & consolidation complete all as specified and directed. |
| 6 | M&L for providing 100mm thick cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed by Engr-in-Charge. |
| 7 | M&Lfor 60mm thick Machine pressed pre casted pressed cement concrete inter locking paver blocks glazedcoloured up to 6mm on the top in any shape and size,with gray cement and no pigment, strength not less than M-35completed all as specified and as directed by Engr-in-Charge. |
| 8 | M&L for providing 75mm thick cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L Chequered cement concrete tiles 300x300x20mm thick, set jointed and pointed in near cement slurry in floors with white cement and pigments in any colour machine preassed glazed , over cement screed bed 20mm thick cement motor 1:4 all as specified and as directed by Engr-in-charge. |
| 10 | M&L machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement to match the shade of the slab including rubbing and polishing, including 20mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and as dierected. |
| 11 | M&L machine cut kota stone slab flooring 20-25mm thickin riser of steps,skirting,dado and pillar laid over 10 mm thick plastering in CM 1:4 set and jointed with grey cement to match the shade of the slab including rubbing and polishing completed all as specified and as directed by Engr-in-Charge. |
| 12 | M & L Glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thickover 10 mm thick plastering in CM 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match completed all as specified and as directed by Engr-in-Charge. |
| 13 | S&F Non skid ceramic coloured tiles7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, set and jointed in neat cement slurry and pointed in coloured cement as in floor over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and as dierected. |
| 14 | Dismantling of brick work built in cement mortar including all quions, arches, pillars, etc.completed all as specified and as directed by Engr-in-Charge. |
| 15 | M&L for Brick work with sub class B bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 completed all as specified and as directed by Engr-in-Charge. |
| 16 | Taking down cement plaster, any description on brick walls or on concrete surfaces including racking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specified and directed by Engr-in-Charge. |
| 17 | M&L for for rendering 15mm thick in CM (1:4) on brick work or concrete surfaces on fair face of brick work, finished fair & even w/o using extra cement in patches with water proofing compound by 3%weight of cement all as specified and directed by Engr-in-Charge.(Note:- Rate of water proofing compund to be used shall be deemed included under this item.) |
| 18 | M&L for rendering 10 mm thick in cement motar 1:6 on brick work or concrete surfaces other than fair face of brick work, finished fair & even without using extra cement all as specified and directed by Engr-in-Charge. |
| 19 | M&L for rendering 5 mm thick in cement motar 1:3 on ceilingon concrete surfaces, finished fair & even without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 20 | Material & Labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces completeall as specified and as directed |
| 21 | M&L Preparing New Plastered Surfaces of WALLS and applying TWO COATS of DISTEMPER OIL EMULSION (OIL BOUND WASHABLE DISTEMPER) over a Coat of CHALK WHITING, complete all as specified and as directed. by Engineer-in-Charge. |
| 22 | M&L Preparation of new plaster surfaces of ceiling, and applying two coat of white wash on ceiling all as directed by Engr-in-Charge. |
| 23 | M&L preparation old treated surfaceby complete removal of existing treatment of walland applying two coat of cement base pant over a coat of primer complete all as specified and as directed. |
| 24 | M&L preparing old distempered surfaces of wall by complete removal of existing treatment and applying two coat of oil emulsion distemper over a coat of Birla / JK wall putty 3mm thick complete all as specified and as directed. |
| 25 | M&L preparing old distempered surfaces of ceiling by complete removal of existing treatment and applying two coat of white wash complete all as specified and as directed. |
| 26 | M & L preparation of old painted surfaces of steel and iron work of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 27 | M&L for preparation of old painted wooden surfaces over 10 cm width or girth and applying one coat of synthetic enamel paintcomplete all as specified and as directed. |
| 28 | Dismantling mild steel work of any description not otherwise provided completed all as specified and as directed by Engr-in-Charge |
| 29 | Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes Fe 410 W (Gde-E-250) quality-A with riveted bolt or welded etc as in duct cover & similar work completed all as specified and directed by Engr-in-Charge |
| 30 | M&L for structural steel rolled section as tubular sections as in vertical steel columns with flange plates, caps, bases, base plates, splices angle brackets, cleats, holding down bolts and nuts and other section complete of Fe 410 W E-250 grade including all welding etc, complete all as specified and directed by Engr-in-Charge. |
| 31 | S&F for MS angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets (for securing with mesh etc including all necessary drilling bolting or riveting etc and similar work confirming to Fe-290 (Gde-E-165 quality-B. Note:-Posts/struts of angle iron made to shape shall be welded to existing angle iron bracket of security wall, contractor shall make his own arrangement for welding for boundary wall by using gen sets or any alternative arrangement. |
| 32 | M&L for Preparation of new steel surface exc 10 cm width/girth one coat red oxide primer and two coat synthetic enamal paint completed all as specified and as directed by Engr-in-Charge. |
| 33 | S&F in repair Galvanized 2 stand Steel Barbed wire 2.24mm dia barbed with dia barbs at 75 mm spacing and straining and fixing to any type of stsnderd rails, straining bolts,including securing or tying at crossings with and provisuion of galvanised mild steel pins, etc including taking down of existing barbed wire as directed (each line wire to be measured) complete all as specified and directed by Engr-in- Charge |
| 34 | S&F in repair 950/650/450 mm dia (as directed by Engr-in-Charge) concertina coil reinforced punched(chrome razor or blade wire with barbed top of 0.5mm thick galvanised sheet and core wire of dia 2.5mm of high tensile steel wire incuding galvanised MS staples/ Clips for tying at crossing complete including taking down of existing concertina coilall as specifiedand directed by Engineer–in-Charge |
| 35 | Dismantling of plain or corrugated steel sheeting / AC sheeting any gauge thickness inculing nanital or similar pattern roor coverings all as specified and directed by Engr-in-Charge. |
| 36 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 37 | S&F 2 mm thick fibre glass reinforced translucent corrugated/ plain sheeting with two corrugations side lap fixed with L type or J-type or cranked hook botls and washer in roof, wall and similar work etc all as specified and directed by Engr-in-Charge. Make: Everest/ MG Polyplast or equivalent make approved in MES in any Command. |
| 38 | Hacking out old broken glass exc 1.5 sqm (any thickness, size, quality or description) from wooden/steel/aluminium frame glazed with putty or fixed with wooden /almn beads etc.completed all as specified and as directed by Engr-in-Charge. |
| 39 | S&F 4 mm thick sheet glass,ordinary quality,in squares n exc 0.5 sq m each pane fixed to aluminium frame with rubber gasket or fixed with glass putty as required etc completed all as specified and as directed by Engr-in-Charge. |
| 40 | S&F 2mm thick Linoleum covering, plain coloured, laid dry in floors including stretching, cutting and fitting complete all as specified and directed |
| 41 | Taking down Chowkhats or frames n exc 1.5 sqm each without taking of shutter from the frame all as specifed and directed by Engr-in-Charge. |
| 42 | Taking down shutter of any discriptionn.exc 1 Sqmeachcomplete all as specified and directed by Engr-in-Charge. |
| 43 | Taking down shutter of any discriptionexc 1 Sqm but n exc 2 Sqm each complete all as specified and directed by Engr-in-Charge. |
| 44 | S&Ffactory made 30mm thicksolidcore Flush door shutter with block board with BWP plywood on both side all as specified directed by Engr in Charge. |
| 45 | M&L second class Hardwood 35 mm thickness, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified by Engr-in-Charge. |
| 46 | M&L second class hardwood 30mm thickness plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats all as specified and directed by Engr-in-Charge |
| 47 | S&F stainless steel wire cloth with 8% nickle 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple complete all as specified and directed by Engr-in-Charge. |
| 48 | S&F frosted sheet glass 3.00 mm thick, ordinary quanlityand glazingwith oil puttyin squares n.exe 0.50 Sqm in each pane. |
| 49 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C\" channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and wood grain printed PVC Sheet used 5mm thick x 15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beaading of 10mm x 10mm used instead of exposed portion of PVC sheet beading for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; supplying & fixing in the frame at site as per specification & drawing. |
| 50 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing. |
| 51 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as specified and directed by Engr-in-Charge |
| 52 | M&L for preparation of new woodensurfacesof anydescriptionnot otherwise described, over10 cm widthor girth and applying two coat of synthetic enamel paint over one coat of pink wood primer all asspecifiedand directed by Engineer-in-Charge. |
| 53 | S&F aluminium anodised 150 mm handle complete all as specified and directed. |
| 54 | S&F aluminium anodised 100 mm handle complete all as specified and directed. |
| 55 | S&F aluminium anodised 150 mm long tower bolt complete all as specified and directed. |
| 56 | S&F aluminium anodised 100 mm long tower bolt complete all as specified and directed. |
| 57 | S&F 100mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 |
| 58 | S&F 75mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 |
| 59 | S&F for Aluminium alloy, anodised sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded section of length of bolt in 200mm complete all as specified and directed. |
| 60 | M&L 18/19 mm thickness prelaminatd particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work as directed by Engr-in-Charge. |
| 61 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 62 | S&F 8 to 10mm thick densified reqular edged eco friendly light weight calcium silicate false ceiling tiles size 600x600mm including main \"T\" runner of size 24x38mm made from 0.33 mm sheet hot deep galvanized steel sectionmaking good existing frame without disterbing the other false ceiling with all as directed by Engr-in-Charge. |
| 63 | M&L for Providing & fixing false ceiling at all heights with Semi perforated 12mm thick micro tegular edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per 8225:1987, Noncombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm.Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 64 | Taking down existing bitumen felt roof treatment including padding/ cement mortar bedding and cleaning the surface and dremoval outside the MOD land, complete all as specified and directedNote- Taking down earthng strips from roof and re-fixing on the same position after APP laying is deemed to be inclusive of rate quoted by the contractor |
| 65 | M&L for Cutting out cracks \"V\" section on existing roofs or terrace cleaning out and filling solidly with a hot mixture bitumen and clean dry sand 1:1 by weight complete all as specified and directed by Engr-in-Charge. |
| 66 | M&L 25 mm thick PCC 1:2:4, type B0 (using 12.5mm graded aggregate ) as in padding of floors/ roofsurface finished even and smoot surface complete all as specified and as directed by Engr-in-Charge. |
| 67 | M & L rendering 10 mm thickfare faces of brick work or concrete surfaces inCM (1:4) mixed with WPC as per manufacturer’s instructions, @ 0.5 % by weight of cement on concrete surface finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately. |
| 68 | M&L water proofing treatment on roof and vertical surface consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 litre/sqm including preparation of roof surfaces (b) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/Sqm on plaster surface all as specified.(c) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/ sqm), duly sealed at over laps & joints with end laps of the 10cm and side over laps of 7.5cm by flame (by torch application) all as per manufacturer’s instructions, complete all as specified and directed. |
| 69 | Supply only water proofing liquid compound complete all as specified and directed by Engr-in-Charge. :Make : DR. FIXIT PIDEPROOF LW,CICO, FOSROC. |
| 70 | M&L for applyingone coat Bitumenwater proofing aluminium heat resistance painton the roof as per manufacture instructions complete all as specified and directed by Engr-in-Charge. Make : PLASCON/PLASCON or equivalent. |
| 71 | S&F in repair 20mm bore , CPVC confirming to IS 15778, SDR 11 pipe first Class with all fittingcomplete fiixed on wall, celling andfloor incl taking down old pipe line complete all as specified and directed by Engr-in-Charge. |
| 72 | S&F powder coated aluminium frame/chowkhat for door shutter of section 101.0x44.4 mm of gauge 16 fixed in brick masonery or conrcrete work by necessary drilling and rawl plug aggangement etc incl polyester powder powder coated aluminium door shutter top rain and middle rail of section 85x44.4 of 16 gauge and bottomrail of section 150x44.4 mm 16 gauge (all section of such type having arrangement for fixing glass/prelaminated board on one or both sides as required) incl aluminium fittings such handle (2 Nos each shutter), tower bolt, locks (mortise type lock) glazing clips, rubber packing, anodised aluminium snap beading screw, hinges type B-21 150mm long (3 Nos each shutter) etc and one door stopper two legged with each leaf (shutter) complete (Glass and prelaminated board to be measured separately under appropriate item of sch A) complete all as specified and directed by Engr-in-Charge |
| 73 | S&F powder coated aluminium frame/chowkhat for window/ ventilator of section 63.5x38.1 mm of16 guage fixed in brick masonery or conrcrete work by necessary drilling and rawl plug aggangement etc incl polyster powder coated of any colour anodised aluminium window & ventilator shutters side hung type without sash bars aluminium with section 44.4x44.4mm of 16 guage including necessary jointing cleats, glazing clips, rubbers packing powder coated anodised aluminium snap beading, screw, powder coated aluminium anodised fittings such as peg stays 150mm long (1Nos), Hinges type B-21 100mm long (2Nos) suitable handle 1 Noscomplete all as specified and directed by Engineer-in-Charge. |
| 74 | M&L in repair fabrication of aluminium composite panel of 4mm thick with .5 mm aluminium core/skin as a tap and bottom layer, middle ;ayer 3mm thick of polythincore (LDPE) and finally with PVDF coating 28 to 32 micron and joints filed with silicon sealant and including aluminium frame of section 37.5mm x 25mm x 1.6mm fixed on the wall/ columns as a cladding and on ceiling of steel structure/ RCC celing withscrew complete incl dismantling of old decayed panels all as directed and as per manufacture\"s instruction, coloured/texture pattern as diesided by Engr-in-Charge all as specified and as directed. |
| 75 | S&FAnodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. all as specified and directed by Engr-in-Charge. |
| 76 | Note:- The amount of Rs 62675.00 against Schedule of Crediton Srl Page 142 shall be deducted from the total amount quoted against Sch \"A\" |