Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | NOTE:- (Applicable for all parts/items/):- The bidders/contractorsare advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 2 | Lumpsum price workedout by the tenderer for BUILDING& STRUCTURE WORKS as listed in Schedule ‘A’ Part-I |
| 3 | Lumpsum price worked out by the bidder/ tenderer forSITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule \"A\" Part-II. |
| 4 | Lumpsum price worked out by the bidder/ tenderer forINTERNAL WATER SUPPLYas listed in Schedule \"A\" Part-III. |
| 5 | Lumpsum price worked out by the bidder/ tenderer forINTERNAL ELECTRIFICATION as listed in Schedule \"A\" Part-IV. |
| 6 | Lumpsum price worked out by the bidder/ tenderer for DEMOLITION/DISMANTLINGas listed in Schedule \"A\" Part-V. |
| 7 | Lumpsum price worked out by the bidder/ tenderer for FIRE FIGHTING SYSTEMas listed in Schedule \"A\" Part-VI. |
| 8 | Lumpsum price worked out by the bidder/ tenderer for LIGHTNING PROTECTION as listed in Schedule \"A\" Part-VII. |
| 9 | Lumpsum price worked out by the bidder/ tenderer for ROAD, PATH & CULVERT as listed in Schedule \"A\" Part-VIII. |
| 10 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLY as listed in Schedule \"A\" Part-IX. |
| 11 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule \"A\" Part-X. |
| 12 | Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSALas listed in Schedule \"A\" Part-XI. |
| 13 | Lumpsum price worked out by the bidder/ tenderer forAREA DRAINAGE as listed in Schedule \"A\" Part-XII. |
| 14 | Lumpsum price worked out by the bidder/ tenderer for COMPOUND WALL, FENCING & STEEL GATEas listed in Schedule \"A\" Part-XIII. |
| 15 | Lumpsum price worked out by the bidder/ tenderer for RETAINING WALL as listed in Schedule \"A\" Part-XIV. |
| 16 | Sch \"A\" Sec-XV (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col. 5 siginifies this fact only. |
| 17 | Dismantling and taking down carefully distribution board any size including MCBscomplete all as specified and directed. |
| 18 | Dismantling and taking down service cable of any size complete all as specified and directed. |
| 19 | Dismantling and taking down GI service bracket of any size and shape complete all as specified and directed. |
| 20 | Dismantling and taking down sub main wiring, aluminium conductor of any size complete all as specified and directed. |
| 21 | Supply, install and testing electric driven fire 3 HP pump horizontal end suction, centrifugal type CI casing and bronze impeller stainles steel shaft, suitable for delivering 1620 LPM, 70 meter head 2900 RPM, including suitable size factory made base frame with channel (Gde Fe-410 S) angle or Tee sections, cut to required length and making holes for fixing of motor and pumps, including providing suitable and vibration pads with nuts, bolts & washers, electrical cable/connections etc. and connecting with suction and discharge water mains including providing suitable foundation complete all as specified and directed. |
| 22 | Supply and hoisting PVC water tank of capacity 10000 Lts (Terrace tank) complete all as specified and as directed. |
| 23 | Supply & Fix100mm bore sluice valve (operation-cap) both side flanged, ISI marked (IS No 14846-2000 class PN-1.6) having cast iron body, cast iron hand wheel, non rising type with brass spindle, cheek nuts and sliding gate type body including testing against any leakages complete all as specified and as directed. |
| 24 | Supply and fixing 100mm bore, cast iron Non return valve, flange type with by pass arrangement class PN 1.6 complete all as specified and as directed. |
| 25 | Supply, install, testing and commissioning outdoor cubical type CPRI approved control panel mounted on pedestal factory made totally enclosed dust & vermin proof (protection class IP 54) (front opening) with proper locking arrangement made out of MS angle iron frame size of 40mmx40mmx6mm and CRCA sheet of 3.15 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide primer. the panel shall be suitable for 415 volts, 50HZ 3 phase 4 wire system with suitable size of PVC insulated copper conductor for internal wiring, thimbles glands complete all as specified and directed. The cost of the PCC pedestal is deemed to be included in the quoted rate. The panel shall comprise of the following Note : Contractor shall submit the design of the panel alonwith accessories for approval before placing the order.a) MCCB TPN 100 Amps 35 KA-01 Nosb) Aluminium Busbar 200 Delta stater suitable for pump set 01 Nosc) Fully automatic star Delta Starter suitable for pump set 01 Nosd) Single phase preventer 01 Nos e) Digital Volt meter with selector switch -01 setf) Digital Ammeter with selector switch-01 |
| 26 | Supply, testing and commisioning of hose reel drum with 20 mm rubber hose pipe 30 m long ISI marked IS 444 hose reel shall be mounting on wall with fastner drilling 20 mm dia including globe valve of size 20 mm and GI pipe fitting for mounting hose pipe 20 mm complete all as specified and directed. |
| 27 | Supply & fix hydrant landing valve type A (Double head outlet ) of 63 mm dia, confirming to IS 5290 complete all as specified and directed. |
| 28 | Supply and fix Pressure gauge 100 mm dia with ball valve of pressure 25 kg/Sqcm complete all as specified and directed. |
| 29 | Supply and fix Cast Iron Automatic air release valve 50 mm dia suitable for domestic water with 50 mm gun metal stop valve complete all as specified and directed |
| 30 | Supply and fix Branch pipe gun metal 63mm instantaneous inlet made threaded outlet 20 mm bore nozzle long complete all as specified and directed. |
| 31 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke dust and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 32 | Material and labour for Preparation of road surfaces and applying thermoplastic reflective paint in marking of minimum 2.5mm thick single coat as in center line and edge line road marking of 150/100mm width using thermoplastic paint (Hot application) white/yellow by indigenous modern propelled road marking machine as directed including all ingredients such as blinder, glass beads Titanium dioxide calcium carbonate inter fillers, thermoplastic requirement for glass beads shall be the table No. 800.4 of MOST specification including spraying of glass beads etc all as per manufacture instructions and as directed |
| 33 | Material and labour for rubber pressed glossy finish chequered cement concrete tiles of size 250x250x25mm thick with 15mm thick screed bed or bedding layer of mortar for laying floor finishes in cement mortar 1:4, etc, set, jointed and pointed in neat cement slurry with grey cement and pigments complete all as specified and directed. |
| 34 | Cutting of existing DI/CI pipes of size upto 300 mm internal dia in position for taking out or connection including necessary excavation in any types of soil complete all as specified and as directed. |
| 35 | Supply, laying and jointing of ductile iron pipes of 150mm bore with spigot and socket ends conforming to IS 8329 : 2000, suitable for push on rubber joint centrifugally cast, class (K-9), inner side cement lining and outer side black bitumen coating andany length, laid in trenches or fixed in floors or on walls including push on rubber (EPDM) ring with ISI marked complete all as specified and directed.Note: Ductile iron fitting such as Bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \"Y\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of suitable size are deemed to be included in the quoted rate. |
| 36 | Supply and fix 3 layered fusion welded PP-R (polypropylene Random Co -Polymer) gate valve (brass insert as per requirement of the site with handle, screwed both ends for PP-R pipes or for unions fixed of grade SDR - 7.4 (PN-16) and size 110 mm complete all as specified and directed. |
| 37 | Supply and fix 3 layered fusion welded PP-R (polypropylene Random Co -Polymer) gate valve (brass insert as per requirement of the site with handle, screwed both ends for PP-R pipes or for unions fixed of grade SDR - 7.4 (PN-16) and size 75 mm complete all as specified and directed. |
| 38 | Supply and fix Cast iron Air release valve with single air outlets confirming to IS 14845 of size 100 mm /90 mm dia bore complete all as specified and directed. |
| 39 | Supply & Fix 150mm bore sluice valve (operation-cap) both side flanged, ISI marked (IS No 14846-2000 class PN-1.6) having cast iron body, cast iron hand wheel, non rising type with brass spindle, cheek nuts and sliding gate type body including testing against any leakages complete all as specified and as directed. |
| 40 | M&L for construction of brick masonry valve pit of size 1050 X 1050 X 1000 mm(internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded aggregate) as in foundation, and 15mm thick rendering in cement mortar (1:4) internally, externally up to 15cm below GL, providing valve pit cover made of 3mm thick MS sheet/plate, welded including provision of hinges, handle and locking arrangement including40 X 40 X 6mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC block 1:2:4 type B-1 (20mm graded aggregate) of size230 X 200 X 100mm, including two coats of anti-corrosive paint over a coat of red oxide zincChrome primer and necessary earth work in soft/loose soil complete all as specified & directed. |
| 41 | Supply, install, testing and commissioning out door type bus bar chamber completely vermin proof, IP 65 class suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory, approved from CPRI having thickness of powder coat not less than 100 microns provided with suitable gasket to make it dust/vermin proof having tapered roof outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 90 cm above and 45 cm below the ground level, frame factory fabricated with front openable door system, 04 Nos Al bus bar 400 amps cap fixed over epoxy insulators duly insulated with different sleeves and neccessary holes of suitable dia in Bus bar strip with locking arrangements “U” type gasket shall be used to make the outer shell all as specified and directed. |
| 42 | Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified),LT feeder pillar box(KIOSK), outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bars suitable Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys,internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size including the provision of space to accommodate the under mentioned items. The scope of work includes the following:- (Main Panel) |
| 43 | Sr. Item No. 15.27(Contd)...(a) Incoming(i)MCCB 4 pole, 415 volts AC grade, 320 Amps rating and 35KA rupturing capacity - 01No (ii) Voltmeter 0-500 volts, square, 144 mm, flush pattern with 3 way rotary selector switch- 01 No(iii) Ammeter size 144 mm, square dial, flush pattern having dual range 1000 amps with three way rotary selector switch with suitable size of LT\"s01 No(iv) Indicating lamps : 01 set of three(b) Outgoing(i) MCCB 4 pole, 415 volts AC grade, 200 Amps rating and 25KA rupturing capacity complete- 02 Nos (ii) MCCB 4 pole, 415 volts AC grade, 160 Amps rating and 25KA rupturing capacity complete- 02 Nos (iii) MCCB 4 pole, 415 volts AC grade, 100 Amps rating and 25KA rupturing capacity complete- 01 Nos (Iv) Indicating lamps on each outgoing.(V) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class `B\", old sizebricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cmabove the nearest road level.Note :(i)All out going feeders shall be connected by cable through suitable size gland plate / glands.(ii) The various feeders shall be indicated by 50 mm size lettersin synthetic enamel white paint. |
| 44 | Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified),LT feeder pillar box(KIOSK), outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bars suitable Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,front opening type, with aprons for cable entry,with double door shutter and locking arrangement lock with 2 keys,internal wiring 2.5 Sqmm with PVC insulated,solid copper conductor, FRLS cables, IS-694marked of adequate size incl the provision of space to accommodate the under mentioned items. The scope of work includes the following:- |
| 45 | Sr Item No. 15.28(Contd)….(a) Incoming(i) MCCB 4 pole, 415 volts AC grade, 100 Amps rating and 36KA rupturing capacity complete - 01 No (ii)Voltmeter 0-500 volts,square,144 mm,flush pattern with 3way rotary selector switch- 01 No(iii) Ammeter size 144 mm, square dial, flush pattern having dual range 1000 amps with three way rotary selector switch with suitable size of LT\"s01 No(iv) Indicating lamps : 01 set of three(b) Outgoing(i) MCCB3 pole, 415 volts AC grade, 63 Amps rating and 25KA rupturing capacity complete with microprocessor based OL, UK & EF protection - 02 Nos(ii)MCB TPN 40 Amps Amps rating and 10KA - 01 No(iii) Indicating lamps on each outgoing.(c) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class `B\", old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cmabove the nearest road level.Note :(i)All out going feeders shall be connected by cable through suitable size gland plate/glands.(ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. |
| 46 | Supply ,installation, testing and commissioning floor mounted transformer of capacity 160 KVA step down, outdoor type, 3 Phase, 50 Hz, AC oil immersed, air naturally cooled (ONAN type), with external cooling tubes/radiators, double wound core type, copper wound having no voltage ratio 11 KV/433 V corresponding to principal tapping, Delta connected primary winding (HV side) and star connected on secondary winding (LV side) in accordance with vector group DYN -11 (Vector group 4) with neutral brought out on LV side and, with automatic voltage regulation in suitable step/positionson HV side for constant output so as to alter/vary secondary voltage of + 5% to 10% in steps of 2.5% by means of manual offload tap changing arrangements complete and conforming to IS-1180 (Part-I) 2014, Maximum loses of transformer shall be energy efficiency level 3 as per IS-1180 (Part-I) 2014, Temperature rise in oil 40°C and windings 45°C, Having percentage of impedence not less than 4.75% complete with all standard fittings and accesssories, gauges, first filling of transformer oil etc complete all as specified and comprising with the following fittings and accessories :- |
| 47 | Sr Item No. 15.29(contd/....)(a) Externally hand operated off-circuit Tap Switch with position indicator and locking device.(b) Conservator with oil gauge, filling hole with plug & drain hole with plug.(c) Under carriage with four plain rollers(d) Oil filling hole cum air release plug - 01 No(e) Drain valve cum sampling valve-01 No(f) Filter valve with plug - 01 No(g) Rating Plate & Diagram Plate - 01 No(h) Lifting lugs for Transformer - 02 Nos(j) Lifting lugs for lid -02 Nos(k) Earthing terminals - 02 Nos(l) Thermometer pocket - 01 No (m) Silica gel breather - 01 No Make: URJA/VOLTAMP/NGEF.Note : (i) The contractor shall provide BEE certified energy efficient level 3 specified in IS-1180 (Part-I) 2014 transformer.(ii) The transformer shall be tested in factory premises before despatch by the representative of Accepting Officer. (iii) The quoted rate shall also deemed to be included for transformer platform of size 2500 x 2500 x 1000 mm with PCC 1:4:8 type D2 foundation and brickwork all around in CM 1:6 including plastering, white washing complete. |
| 48 | Supply and fixing expulsion type drop out fuse unit suitable for 11000 volts and current rating 50 to 100 Amps shall be mounted on MS Channel complete with two post insulator for 11000 volts including necessary clamps, nuts, bolts, washers, the exposed steel surface shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified all as specified and as directed. |
| 49 | Material & Labour for Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion complete all as per specified and as directed. |
| 50 | Supply & fixing of Automatic Street Light Control Switch suitable for Single Phase with Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS). Nature Switch operation should be based on Natural Light Lux level. Required Illuminance Level for Switching ON is ≤ 30/60 Lux and for switching OFF ≥ 10 Lux. The Sensor should also have part night operation facility of min. 4 to max. 12 hrs. VMS should have Adjustable Over & Under Voltage Trip level and Protection against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & VMS along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP54. The circuit should also have provision for Manual Operation (i.e. By-Pass Option for both Sensor complete all as per specified and as directed. |
| 51 | Supply & Fix PVC street light junction box of size 300 x200 x110mm with front openable shutter and locking arrangement for bus bar fixed on porcelain insultor and fixed to pole with MS flat iron clamp 25 mm x 3mm size with nuts and bolts washers, etc complete all as specified and directed. |
| 52 | Supply and fixing cable route indicator over the HT/LT cable made out of cast iron block 100 mm dia 8 mm thickness and fixing with MS strip of size 40 mmx6 mm, upto length 75 cm and marked with HT/LT cable size including excavation and earthwork, PCC foundation etc, complete all as specified and directed. |
| 53 | Supply and fixing 2.5 sqmm twin core copper cable including suitable protection PVC pipefor connection junction box to street light complete all as specified and as directed. |
| 54 | Supply & fix DWCPE (SN 8) 150mm inner dia pipe laid in trenches ISI marked with smooth internal and corrugated (profiled) external surface with anti rodent property and shall be conforming to IS-16098 (Part-2) : latest amendmended laid in trenches including connections and fittings complete all as specified and directed. |
| 55 | Supply & fix DWCPE (SN 8) 200mm inner dia pipe laid in trenches ISI marked with smooth internal and corrugated (profiled) external surface with anti rodent property and shall be conforming to IS-16098 (Part-2) : latest amendmended laid in trenches including connections and fittings complete all as specified and directed. |
| 56 | M & L for RCC septic tank conventional type for 150 users design to carry sewage and sludge water constructed with RCC M-30 (Design Mix) including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/STD-02 sheet 1/2 & 2/2 and complete all as specified and directed. |
| 57 | M & L for RCC septic tank conventional type for 100 users design to carry sewage and sludge water constructed with RCC M-30 (Design Mix) including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/STD-02 sheet 1/2 & 2/2 and complete all as specified and directed. |
| 58 | M & L for soakage well of size 3.0 m dia and 3.0 m effective depth including intercepting chamber and screen chamber, including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/TD-45, sheet 1/2& 2/2 complete all as specified and directed. |
| 59 | M & L for soakage well of size 1.8 m dia and 3.0 m effective depth including intercepting chamber and screen chamber, including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/TD-45, sheet 1/2& 2/2 complete all as specified and directed. |
| 60 | Construction of Steel gate 6.0m wide & 2.1m height with RCC pillar including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2017/TD-034, sheet 1/3& 3/3 complete all as specified and directed. |
| 61 | Supply and laying ofpolyester needle punched non woven geo textile drainge composite Non woven geo textile 2 layers net in between conforming to IRC 34-2011 complete all as specified and directed. |
| 62 | Material & Labour for Concealed Point wiring with 1.5 Sq. mm (nominal cross sectional area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one light/fan/bell/exhaust point controlled by one way switch. |
| 63 | Material & Labour for Concealed Point wiring with 1.5 Sq. mm (nominal cross sectional area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one socket outlet point 6 Amp on same board. |
| 64 | Material & Labour for Concealed Point wiring with 1.5 Sq. mm (nominal cross sectional area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one socket outlet point 6 Amp on independent board. |
| 65 | Material & Labour for Concealed Point wiring with 1.5 Sq. mm (nominal cross sectional area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one light point controlled by two way switch. |
| 66 | Concealed Point wiring with 4 Sq. mm (nominal area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 4 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one16 Amps socket outlet on independent board. |
| 67 | Supply and fix Piano switch single pole two way flush type 6 Amps, 230 volts, complete all as specified and directed. |
| 68 | Sub main wiring with two runs of single core FRLSH PVC insulated and unsheathed multistranded, copper conductor cable of size 6 Sq mm (nominal area), 1100 volts grade drawn through and including adequate size PVC concealed conduit and accessories (IS-694 marked in PVC conduit) and fittings and one run of 6 Sq mm single core FRLSH multistranded copper conductor cable as earth continuity conductor.NOTES :-(a) Two runs of copper conductor, one run of earth wire and one run of conduit shall be measured as one run length. |
| 69 | Sub main wiring with four runs of single core FRLSH PVC insulated and unsheathed multistranded, copper conductor cable of size 10 Sq mm (nominal area), 1100 volts grade drawn through and including adequate size PVC concealed conduit and accessories (IS-694 marked in PVC conduit) and fittings and one run of 10 Sq mm single core FRLSH multistranded copper conductor cable as earth continuity conductor.NOTES :-(a) Four runs of copper conductor, one run of earth wire and one run of conduit shall be measured as one run length. |
| 70 | Supplying and laying of 40 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches including special fittings like CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brassadaptor) complete all as specified and directed. |
| 71 | Supplying and laying of 32 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches including special fittings like CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brassadaptor) complete all as specified and directed. |
| 72 | Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches including special fittings like CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brassadaptor) complete all as specified and directed. |
| 73 | Supply & fix cromium plated health faucet suitable for 15 mm bore pipe with 1.2m long flexible tube and wall hook including making connections complete all as specified and directed. |
| 74 | Supply & fix LED bulb 9 watt B22 complete all as specified and directed. |
| 75 | Supply & fix Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 76 | Supply and lay M S Pipes of 15mm bore heavy grade with all fittings laid in floors or fixed to walls and ceilings or laid in trenches complete all as specified and directed. |
| 77 | SCHEDULE \"A\" PART-XVI (Provisional lumpsum) Lumpsum price worked out by the tenderer forProvisional sum of` 23,00,000/- for following items including of earth work, concrete work, steel sectionetc. complete all as directed.(i)Play ground: 01 No(ii)Basket ball court : 01 No(iii)Volley Ball Court: 01 No (iv)Badminton Court : 01 NoNote:- Contactor shall quote against pre-priced amount. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail