| Sl. No. | Item Description |
| 1 | Schedule-A (B/R / EM Works) |
| 2 | Demolition of cement concrete in ground floors and pavings exc 15 cm thickness above ground level as in sunken floors etc |
| 3 | Demolition of RCC of any descrition and in any position not other wise specially provided for complete all as specified and directed by Engineer in Charge (reinforcement cut as required to facilitate demolition) |
| 4 | M&L for RCC1:2:4 type B-1 using 20mm for Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed |
| 5 | M&L for gunniting to RCC works in column beams, slabs, chajja, facia, landing, balconies etc by removing/ dismantling of RCC (loose concrete) and cutting of steel barincluding plaster cleaning of surfaces with wire brushes and applying epoxy, paint anti corrosive coating of minimum 40-50 microns thick with sikatop Armatec 108 or Colusal VL of MC Bauchemie to rusted steel reinforcement after removing cleaning all rust and supply and fixing welded steel wire mesh 75mm x75mm with 4mm dia steel wire as facies/drops and similar works etc and expoxy based or other equivalent suitable bonding against treatment to be carried out on old concrete surface with Sikadur 32 of Sikka.Nito bond EP of fosroc or equivalent (as per manufacturers instruction) to bond old and new concrete mixing @ 2% by weight of cement polycrete and providing gunniting with a minimum pressure of 2 to 2.5 Kg sqcm and applying 35mm thick gunniting in cement mortar (1:2) (one part of cement and two part of ghaghar sand)using ordinary port land cement of 43 grade over wherever required, complete all as specified and directed by Engineer-in-Charge. Note:-(i) After placing the additional reinforcement all concrete surface shall be thoroughly scrubbing with. (ii) Additional reinforced TMT bars where incorporated in work and including 20mm thick cement plaster in 1:4(iii) Work to be carried out as in patches as directed by Engr-in-charge. (iv)Rate for steel scaffolding upto 10m height as directed to be included in quoted rate. (v) All demolished material removed from MoD land completely.(vi) All loose concrete fallen on floor while gunniting to be cleaned & removed from site to outside MoD land. |
| 6 | M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed |
| 7 | M&L TMT steel bars 6mm to 8mm dia and over cut to length bent shape required, including cranking bending binding with mild steel wire (annealed) not less than 0.9mm dia quality conforming to relevant IS complete all as specified and as directed |
| 8 | Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each and removal from site all as specified and directed |
| 9 | Taking down chowkats or frame with shutter (without taking out shutter from the frame) exceeding 1.50 sqm and n exc 4.00 sqm each and removal from site all as specified and directed |
| 10 | S & F pressed steel frames of size 165 x 60 mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete as specified |
| 11 | S & F pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete as specified |
| 12 | M & L for PCC 1:3:6 type C1 as in filling back side of pressed steel door frames |
| 13 | Cutting holes into or through brick walls buil in cement mortar or cement limeand making good in cement mortar 1:3 n exc half brick thick but not exe one brick thick for inserting hold fast etc |
| 14 | S & F 35 mm thick first class Hard wood glazed skeleton shutters open rebated and prepared to receive guage etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc and fitted to chowkats |
| 15 | S & F 35 mm thick plain framed panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density wood particle board with commercial face veneers and fixed to chowkats |
| 16 | S & F 30 mm thick factory made flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides |
| 17 | S&F anodised aluminium frame powder coated (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or morerebates including joining cleat for fixing etc. complete all as specified |
| 18 | S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No) hinges type B-21 100mm long (2 No) suitable handle (1 No) in each pane complete all as specified |
| 19 | S&Fstainless steel wire cloth , 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples. |
| 20 | S & F frosted sheet glass 4.00 mm thick , ordinary quality and glazing with oil putty in squares n.exc 0.50 Sqm in each pane. |
| 21 | M&L, for 12 mm thick pre-laminated particle board, exterior grade, pre-laminated on both side with decorative choice laminations fixed between aluminium section with and including snap fitting aluminium clips of polyester powder coated along with the glass with rubber gasket, complete all as specified and directed by Engr-in-Charge. |
| 22 | Floor door stopper of aluminium alloy 150mm body and tongue, anodised, with hard drawn steel spring. Fixed in floor |
| 23 | S&F for Aluminium alloy, anodised sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded section of length of bolt in 200mm |
| 24 | S&F aluminium anodised 150 mm long tower bolt |
| 25 | S&F aluminium anodised 100 mm long tower bolt |
| 26 | S&F aluminium anodised 100 mm handle |
| 27 | S&F aluminium anodised 150 mm handle |
| 28 | S&F aluminium anodised 100 mm butt hinges type B-21 |
| 29 | S & F 100 mm size mildsteel butt hinges medium weight cold rolled andfixed with screws or welding where required |
| 30 | S & Fmild steel 300 mm , ordinary rat rail rod pattern springs including rollar and rollar plate complete. |
| 31 | S&F Aluminium anodised alloy curtain rods with fixing brackets,stops,rollers etc.fixed in repairs. |
| 32 | S & F for factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube fixed in opening complete as per manufacturer\"s specifications and as directed by Engineer-in-Charge |
| 33 | S & F for 30 mm thick factory made solid panel PVC door shutter confirming to criteria of testing as per IS : 4020, consisting of frame made out of MS tube of 19 guage thickness & size 19x19mm for stiles and 15x15mm for top & bottom rails MS frames shall have a coat of red oxide primer of approved make and shall be covered with 5mm thick heat moulded PVC `C\" channel of size 30x50mm forming styles and 5mm thick 75mm wide PVC sheets for top rail lock rail and bottom rail on either side and 10mm (5mmx2) thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail panelling of 5 mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rail with 30 mm wide x 5 mm thick PVC sheet beading on either side and joined together with solvent cement, adhesive and an additional 5 mm thick PVC strip of 20 mm width is to be struck on the interior side of \"C\" channel using PVC solvent adhesive complete as per manufacturers specifications & drawings ass as directed by Engineer-in Charge |
| 34 | Dismantling existing tanks Exc 500 lit and N exc 1000 lit capacity |
| 35 | S & F750 ltrs Rotational moulded polyethylene water storage tanks three layer (cylindrical vertical with closed top) hoisted and fixed in position all as per specified and directed. |
| 36 | S&F Ball brass valve for 20mm bore pipe high pressure with polyethylene float and fly nut complete screwed for iron pipe. |
| 37 | S& F Tank adaptor GI 20mm dia complete all aspecified. |
| 38 | Taking down or up 15 mm bore galvanised iron tubing and connection including cleaning for refixing or removal to store all as specified |
| 39 | All as per item No 37 here in before but 20 mm bore |
| 40 | Supplying and laying 16mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 41 | All as per serial item 5 here in before nut 20 mm bore |
| 42 | S & F 20 mm bore stop valve cast copper alloy screwed down high pressure with crutch butter fly handle screwed both ends for iron pipe all as specified and as directed |
| 43 | Taking down cement plaster including raking out joints hacking for key and scrubbing down with water |
| 44 | M & L 10 mm thick rendering in CM (1:6) on vertical surfaces of brick walls finished even and smooth without using extra cement |
| 45 | M & L 15 mm thick rendering in CM (1:4) on vertical surfaces of brick walls finished even and smooth without using extra cement with using water proofing compound (WPC will be measured and paid separately) |
| 46 | M & L for rendering 5 mm thick on ceiling on fair faces of concrete surface in Cm 1:4 finished even and smooth without using extra cement all as specified |
| 47 | M & L for preparation of new plastered surfaces of walls and applying two coat of Oil Bound distemper of approved tint, over a coat of 3mm thick wall care putty complete all as specified. |
| 48 | M & L for preparation of newly plastered surfaces and applying two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces |
| 49 | M&L for preparation of newly plastered surfaces applying 3 coats of white washing on internal/ external ceiling complete all as specified. |
| 50 | M & L preparation of new wood surfaces and applying two coats of sythetic enamel paint over a coat of wood primer |
| 51 | All as per item No 61 here in before but on steel surfaces over a coat of red oxide |
| 52 | M&L for preparation of old plastered surface of ceiling and applying one coat of white wash complete all as specified and directed by Engr-in-charge |
| 53 | M&L preparing old distempered surfaces of wall by complete removal of existing treatment and applying two coat of oil emulsion distemper over Birla / JK wall putty complete all as specified and as directed. |
| 54 | M & L for preparation of old painted surfaces and applying two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed |
| 55 | M&L for preparation of old painted wooden surfaces over 10 cm width or girth and applying one coat of synthetic enamel paintcomplete all as specified and as directed. |
| 56 | M & L preparation of old painted surfaces of steel and iron work of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 57 | M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete(Fe 410-W (Gde E-250) quality B) |
| 58 | M&L Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified (Paymentfor providing grooves shall be made separately). |
| 59 | M&L Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge |
| 60 | Dismantling of cast iron drain pipe jointed in lead joints or cement joints and taking out of under floors if required |
| 61 | Demolition of brick work or stone / boulder masonary, built in cement mortar including all quoins, arches, pillars etc., complete all as specified and directed. |
| 62 | M&L for brickwork with subclass \"B\" bricks,straight or curved on plan exc 6m mean radius built in CM1:6 complete all as specified and directed |
| 63 | S & F 110 mm bore of pipe PVC (SWR) pipes single socket in any length with rubber ring joint fixed to walls with MS clamps as directed 6 Kg/Sq cm. |
| 64 | S & F 110 mm bore of pipe PVC (SWR) bends of any radius / shoefixed to PVC pipes as directed |
| 65 | S&F 75mmborePVC(SWR) pipessingle socketed, in any length fixed to walls/laid in floors/trenches all as specified and directed |
| 66 | Supply and Fix in repairs PVC (SWR) bend any radius with access door suitable for 75mm dia pipes. |
| 67 | Supply and FixPVC (SWR) Vent cowl suitable for 75mm dia vent pipe. |
| 68 | S&F PVC floor trap,75mm outletdiaplain with grating includingjoining with solvent cement all as specified and directed |
| 69 | S&F PVC gully trap,125/110mm outletdiaincludingjoining with solvent cement all as specified and directed |
| 70 | S&F Shelf of PTMT fixed with and including chrominium plated brass screws and wooden/plastic cleats (minimum weight 300gm) |
| 71 | Dismantling of asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed by Engr-in-Charge. |
| 72 | S&F pre-painted galvalume aluminium zinc coated GI based corrougated steel sheet 0.50 mm thick of any colour having tansile strength of 550 MPA as in roof covering/glading to wall fixed with selftapping screws, complete all as specified and directed by Engr-in-Charge. |
| 73 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed |
| 74 | M&L Cement concrete 75 mmthick type C-2, 1:3:6 (40mm graded aggregate)mass concrete as in sub base |
| 75 | M&L Cement concrete 25 mm thick type B-1, 1:2:4, (20mm graded aggregate) as in flooring |
| 76 | M&L Chequered cement concrete tiles (vibrator made) 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over 15 mm thick screed bed in CM (1:4) finished with cloured cement to match the shed of the slab |
| 77 | Providing & fixing false ceilingat all heights with semi perforated 12mm thick micro tegular GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and Lshape level adjuster of size 85x25x2mm.The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. |
| 78 | M & L for 100 mm thick PCC 1:3:6 type C2 as in plinth protection fisished even and smooth without using extra cement as specified |
| 79 | M & L 40 mm thick PCC 1:2:4 type B0 using 12.5 mm graded aggregate using water proofing compound as in sunken floor(WPC shall be measured and paid separately) |
| 80 | M& L Applying evenly a coat of blown type bitumen at the rate of 1.50 kg/sqm and binding with clean dry sand @ 0.05 cum per sqm |
| 81 | Dismantling of mild steel work of any description not other wise provided of all as direted by Engr-in-Charge. |
| 82 | S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc (Fe410W E250 quality A) complete all as specified and as directed |
| 83 | M & L for rendering 15 mm thick in CM 1:4 with using water proofing compound (WPC shall be measured and paid separately) all as specified |
| 84 | Supply only Liquid water proofing compound of approved quality |
| 85 | M & L PCC 1:5:10 type E2 as in sub base of floor mass filling using 40 mm graded aggregate with using water proofing compound |
| 86 | S & F GI tubing medium grade with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 32 mm bore (Spout pipe for sunken portion) complete all as specified. |
| 87 | S&F in repairvitreous china wash basin, white, flat back, size 550 mm x 400 mm fixed on and including cast iron cantilever bracket 32 mm dia brass waste coupling and including fixing of tap, waste fitting and union complete all as specified and as directed. Note : Pillar tap shall be measured as supply only under respective item. |
| 88 | Supply and fixed in repair 15 mm dia bore pillar taps cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or “cold’ with long screwed shank and flynuts, screwed for iron pipe and fixed complete all as specified and as directed.(Make: Prayag ) Cat No : 8306 |
| 89 | S&F 32 mm bore of pipe low density (LDPE) of pressure rating 6 kg/ sqcm fixed to wall or floor etc including fittings complete all as specified and as directed. |
| 90 | Supply only 32mm dia waste cupling fitting brass chromium plated for basin with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed. |
| 91 | S & F in repair PVC connection 15 mm size with PTMT nuts of length 450 mm of approved quality |
| 92 | S & F15 mm chromium plated cast copper alloy bib taps with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete allas specified and as directed. |
| 93 | S&F Brass CP mixer for mixing hot & cold water screwed down for iron pipe all as specified and as directed by Enginerr-in-charge |
| 94 | S & F 15 mm dia bore angle Cock with Flangechromium plated fancy type with long shank & cup (concealed type) complete all as specified and as directed. |
| 95 | S&F kitchen sink with drainage board made outof 1mm thick stainless steel with plugs, washers and wastes, including bedding in cement mortar to dwarfwall or including fixing cantilever bracket and connecting union to pipe over all size 915 mm X 460 mm & bowl size 410 mm X 330 mm X 160 mm complete all as specified and as directed. |
| 96 | S&F brass chromium plated tubular towel rail 20 mm dia D type, 60 cm long between flanges complete all as specified and as directed. |
| 97 | S&F in repair Swivel shower of PTMT any colour for fixing with 15mm pipe (Minimum weight 40gms) including showerarms 15 mm size 195 mm long with bendcomplete all as specified. |
| 98 | S & F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to trap and to flushing pipe incl concrete bedding and connection to antisyphonage pipe etc including CI \"P\" trap dia 100 mm thick complete all as specified . |
| 99 | S & F in repair PVC low level cistern of 10 lit capacity inclusive of brackets and PVC bend long type and connectin to flush pipe of any size and pattern with inlet ball valve float and handle complete of approved make |
| 100 | Dismantling floor hearth or wall tiles including cement mortar (but not backing) removing serviceable tiles to store and rubbish off the premises |
| 101 | S&F Non skid ceramic coloured tiles7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, set and jointed in neat cement slurry and pointed in colour cement as in floor over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and as dierected. |
| 102 | -Ditto- but vertical surfaces including 10 mm thick rendering in CM 1:4 |
| 103 | M & LGlazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in colour cement to matchover 10 mm thick plastering in CM 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match |
| 104 | M&L for 100mmthick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) complete all as specified and as directed |
| 105 | M&L machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement to match the shade of the slab including rubbing and polishing, including 20mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and as dierected. |
| 106 | M&L machine cut kota stone slab flooring 20-25mm thickin riser of steps,skirting,dado and pillar laid over cement screed base laid and jointed with grey cement to match the shade of the slab including rubbing and polishing |
| 107 | Rounding to edge of stone slabs one edge such as steps, cooking platform and other similar situatiion |
| 108 | M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.ncluding 20mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and as dierected. |
| 109 | S&F for 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc. complete all as specified and as directed |
| 110 | S&F M.S square/circular tube M.S pipe etc conforming to IS-1161-1979 gardegrade YST 240 fixed with fastener complete all as specified and directed. |
| 111 | M&L Galvanised Iron steel wire 4mm dia fixing to wall and pole complete all as specified and as directed. |
| 112 | Removing existing roof treatment and preparing surfaces to the entire satisfaction of Engr-in Charge /GE including taking down existing plaster,cleaning of all foreign material such as grass roots dust etc and roughening the concrete surfaces by wire brushes and washing down to remove dust etc . flushing at junction of parapets complete and removing the same to the places where directed by Engr-in-Charge. |
| 113 | M&Lfor Rendering 15mm thick on Fair faces with WPC of brick or concrete surfaces in CM 1:4complete all as specified and as directed.(WPC measured and paid separately |
| 114 | M&l Applying evenly a priming/tack coat with bituminous primer at 4 kg per 10 sq meters |
| 115 | APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified |
| 116 | M&L preparation of surface two coat of aluminium paint for APP membrane , over 10cm in width or girth, not otherwise described complete all as specified and as directed. |
| 117 | M&L for providing cement concrete 1:3:6 Type C1 (20mm graded aggregate) as in cover slab for manholes complete all as specified and as directedNote : Steel reforcement to be measured and paid separately. |
| 118 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers ® complete all as specified and as directed |
| 119 | M&L for providing 100mm thick plain cement concrete (1:4:8) type D2 using 40mm graded aggregate as in sub basecomplete all as specified and as directed |
| 120 | M&L 25mm thick sand filling/ cushion under floors or in foundation including watering and consolidation complete all as specified and as directed |
| 121 | M&L Machine pressed precast concrete interlocking paver block any shape and sizeconfirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey pigment and cement complete all as specified and as directed |
| 122 | Cleaning of sewage lines by rodding/pumping, bamboos etc including man holes of any description by taking out night soil excreta and solid sludge and buried under 30 cm deep soil by digging suitable size of pits 100 mtr away from the site complete all as specified and as directed. Note:-1. Excavation of pit and removal of surplus soil is deemed to be included in unit rate.2.Contractor shall arrange water for jettin, refilling to tank including lanours required to be engaged in teh work and rubbish off the sludge beyond MD land.3. Bleaching powder to be spread over and all around of buried night soil/sludge. |
| 123 | M/L PCC 1:2:4 type B-1 using 20mm graded aggregate as sub base 40mm thick in floors |
| 124 | M&L screed bed or bedding layer of mortar 15mm thick rouh finished to recive tiles as in floor finishes with CM 1:4. |
| 125 | M&L for vitrified tiles10mm thick (squar / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqmas in skirtingset and jointed in neat cement slurry andjointed in white/coloured cement to match, complete all as specified and as directed by Engr-in-charge. |
| 126 | M&L for vitrified tiles10mm thick (squar / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqmas in skirtingset and jointed in neat cement slurry andjointed in white/coloured cement to match over and including10 mm thick rendering in cement mortarin1:4, complete all as specified and as directed by Engr-in-charge. |
| 127 | M&L for 12mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and directed by Engr-in-Charge. |
| 128 | S&F powder coated aluminium door shutter top rail and middle rail of section 85x44.4 of 16 gauge and bottomrail of section 150x44.4 mm 16 gauge (all section of such type having arrangement for fixing glass/prelaminated board on one or both sides as required) incl aluminium fittings such handle (2 Nos each shutter), tower bolt, locks (mortise type lock) glazing clips, rubber packing, anodised aluminium snap beading screw, hinges type B-21 150mm long (3 Nos each shutter) etc and one door stopper two legged with each leaf (shutter) complete (Glass and prelaminated board to be measured separately under appropriate item of sch A) complete all as specified and directed by Engr-in-Charge |
| 129 | S&F 4.8 mm thick Sheet glass, ordinary quality and glazing with existing rubber bead in square exc 0.5 sq. m in each panel fixed to aluminium frame of any section as in item here-in-before incl snal fit aluminium clips of polyester powder coated along the glass with rubber gasket complete all as specified and directed by Engr-in-Charge. |
| 130 | M&L 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work |
| 131 | S&F SS handel for Tougen glass doors 450mm long |
| 132 | SF floor spring incl pintel hinge at top and attachment cleats required in toughen glass doors complete |
| 133 | M&L Solid PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing |
| 134 | 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. |
| 135 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 136 | Taking down sub main wiring complete including fitting and fixtures, removing materials to store or keeping in safe custody and making good the disturbed surfaces of walls, floors, roof etc., all as specified and as dirfected. |
| 137 | Taking down carefully unserviceable DB any type/size disconnecting and making good disturbed surfaces complete all as directed |
| 138 | Taking down carefully unserviceable MCB SP/SPN/Isolator of any rating/size. |
| 139 | M&L Point wiring complete with 1.5 sqmm single core PVC insulated andunsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC concealed conduit fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60 mm thick MS sheet concealed in walls, suitablefor housing the modular electrical accessories as switches, socket outlets, fan regulators etc., all as specified and as directed for the following: - |
| 140 | (a)One light point controlled by one 6 Amps one way switch. |
| 141 | (b)One ceiling Fan, Exhaust Fan point controlled by one 6 Amps switch. |
| 142 | (c)One 3 Pin 6 Amps socket point on the independent board. |
| 143 | All as perabove item No-5 but with 2.5 Sqmm cable for 16 Amp switch socket out let point on independent board including 1.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor earthing continuity conductor all as directed and specified by Engr-in-charge. |
| 144 | S & Fix modular switch1 way 6A, 1 module |
| 145 | S & Fix modular switch1 way 16A, 1 module |
| 146 | S & Fixsocketout let 6A 2/3 on combined 2 module |
| 147 | S & Fix socket out let 6A/16A-2/3 pin combined 2 module |
| 148 | S & Fixceiling rose surface backlite 65x50mm 3 terminals complete. |
| 149 | S/F modular white cover plate with frame, 3 module |
| 150 | S/F modular white cover plate with frame, 4 module |
| 151 | S/F modular white cover plate with frame, 6 module |
| 152 | S/F metal flush box 3 module |
| 153 | S/F metal flush box 4 module |
| 154 | S/F metal flush box 6 module |
| 155 | S & F LED tube light along with fixture,22 W. |
| 156 | Supply & fix LED High bay , 70/72 WAC in door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. |
| 157 | S & F sheet metal enclosure MCB DB VTPN double door 4 way suitable for 415 V with 200 amps rated bus bar including flushed on walls and making good disturbed surfaces including taking down the old DB. Model6077 50 Make :/ Seimens/ABB |
| 158 | Supply and fix sheet metal enclosure distribution board SPN, 8 ways 240 volts, with 200 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs all as specified and as directed including taking down old MCB DB complete. , Make -or equivalent in ABB/ Siemens |
| 159 | Supply and fix MCB single pole, 240 volts, 5 to 32 Amps, all as specified and as directed. |
| 160 | Supply and fix MCB single pole and neutral, 240 volts, 5 to 30 Amps, all as specified and as directed. |
| 161 | Supply and fix MCCB 25KA , 415 volts,100Amps,4 pole all as specified and as directed. |
| 162 | S & F metal plug and socket with MCB 20A SPN for AC. |
| 163 | M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall all as directed by Eng-in-charge. |
| 164 | Sub main wiring complete with two runs of4 sqmm single core PVC insulated unsheathed single corecable 1100 volts grade, multistranded with copper conductor drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories ,fixed to walls / roofs / floors etc., with one run of 2.5 Sqmm single core multistranded copper conductor as earth continuity conductor, all as specifiedinclduing dismantling unseriveable sub main wiring including accessories. Note : Two runs of copper conducter and one run ofearth copper conducter shall be measured as one length. |
| 165 | S & Fix PVC couduit of size 25 mmrun in wall / surface for existing telephone cable / Lan cable all as directed and specified by Enge in charge. |
| 166 | Supply & fix Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting. |
| 167 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 168 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 169 | Supply and Installation of Solar water heating system ,Flat plate collector type,with heat exchanger of 300 litre per day capacity ,with electrical heating back up icluding cold water tank of capacity 500 ltrs. All as specified and directed. |
| 170 | Note:- The amount of Rs24693.00against Schedule of Crediton Srl Page150 shall be deducted from the total amount quoted against Sch \"A\" |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail