| 1 | Work |
| 2 | Waterproofing treatment of joints of Kota stone flooring at roof level by cleaning, filling with cement slurry mixed with waterproofing compound and sealing with approved polyurethane/polysulphide sealant including all materials, labour, tools and curing complete as per direction of Engineer-in-Charge. |
| 3 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either redesign the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 4 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 5 | Providing, fixing and tensioning tensile fabric membrane (PVC coated polyester / PTFE / PVC-PES) including stainless steel fittings, turnbuckles, anchor bolts, wire rope, neoprene gaskets, sealants, erection, tensioning, testing as required and all incidental works complete as per direction of Engineer-in-Charge. |
| 6 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 7 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 8 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. |
| 9 | Making hole/opening in brick wall for pipe line and making good including finishing complete as per direction of Engineer-in-Charge. Includes: Cutting, chiseling or coring of parapet / brickwork, inserting pipe sleeve, and making good the surface with cement mortar after installation. |
| 10 | Providing valleys of 90 cm wide overall in plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete :1.60 mm thick with zinc coating not less than 350 gm/m² |
| 11 | Providing flat iron brackets 50x3 mm size with necessary bolts, nuts and washers etc. for fixing G.S. sheets gutters with purlins. |
| 12 | Providing and laying kerb stone made up of red sand stone of size 0.30 x 0.30 x 0.10 mtr in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). |
| 13 | Supplyof Cast Iron Benches with Arm Rest having 3 seater seating capacity of size approximately 1620 x 620 x 740mm weight approx. 85 Kg. (+-5%) grated with MS Iron rectagonal pipe of size 7 cm. x 3cm. x 2mm thick. 11 nos. horizontal post painting with required colour and placing them as per the instructions of site incharge. |
| 14 | Providing and fixing stainless steel dustbin of 30 litre capacity made of 1 mm thick SS 304 sheet (perforated or plain), mounted on two stainless steel legs (Grade 304 pipe 38–40 mm dia, 16 gauge), including necessary excavation in ground up to 300 mm depth, providing and laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) foundation block, fixing with stainless steel fasteners, finishing, polishing, and complete as per direction of Engineer-in-Charge. |
| 15 | Removing carefully the existing split/cassette/ductable type air conditioner ( outdoor units) including disconnection of refrigerant and electrical connections and refixing the same after shifting at the required location, testing and commissioning complete as required as per direction of Engineer-in-Charge. |
| 16 | Providing and fixing black polythene sheet over existing dome surface including overlapping, seaming/welding as required, fixing with stainless steel washers/screws at required spacing, sealing joints with approved sealant, making good and cleaning, complete as required |
| 17 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil |
| 18 | Supply of high quality 48-55W flood spot light with precision beam optics, UV- resistant PC; Protection Rating : IP65/ IK07 ; Die cast aluminum; SDCM |
| 19 | Installation including excavation, foundation, wiring cabling, earthing, testimng & commissioning of the above light fixtures. The work also includes all the accessories , connections in main LT panel box and of all wires, cable, earthing and MCCB/MCBs as per Engineer-in-Charge. |
| 20 | Supply of high quality 12W IN-GROUND ASYMMETRIC mono colour round wash light, UV-resistant glass cover; diecast aluminum with SS outer ring 304 grade; SDCM |
| 21 | Installation including excavation, foundation, wiring cabling, earthing, testimng & commissioning of the above light fixtures. The work also includes all the accessories , connections in main LT panel box and of all wires, cable, earthing and MCCB/MCBs as per Engineer-in-Charge with proper stone/metal cages for lights protections. |
| 22 | SITC of heritage post top lights to light up the parking/pathway lot, CCT of 3000K with twin lamps. (2X 20W) |
| 23 | Installation including excavation, foundation, wiring cabling, earthing, testimng & commissioning of the above light fixtures. The work also includes all the accessories , connections in main LT panel box and of all wires, cable, earthing and MCCB/MCBs as per Engineer-in-Charge with proper light protections. |
| 24 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 25 | Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 7.32.1 Red sand stone |
| 26 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 27 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 28 | Supplying, Testing, Repairing and Rectification of Fire Alarm System (existing in the convention center including cyron) |
| 29 | Providing, fixing, testing and commissioning of ABC type (stored pressure) fire extinguisher of capacity 6 kg, complete with all accessories including bracket and instructions, as required. |
| 30 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 31 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend. |
| 32 | Painting with Duco Paint of approved brand paint along with primer of approved brand : Two or more coats on new work. |
| 33 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. |