| Sl. No. | Item Description |
| 1 | Dismantling plain or corrugated steel sheeting, any gauge, thickness as in roof coverings. |
| 2 | Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed. |
| 3 | Dismantling of timber scantling 40 Sqcm and over in section in any position as in framed work complete all as specified and directed. |
| 4 | M&L for second class hardwood (wrought) in scantling for woodn truss and boarding complete as specified and directed |
| 5 | Fixing only second class hardwood (wrought) in scantling for woodn truss and boarding complete as specified and directed ( Note :- Timber shall be obtaind from item No -03 above) |
| 6 | M&L for 20mm 2nd class hardwood Boarding, supplied & fixed with nails in any situation (except flooring and skirting) |
| 7 | Fixing only second class hardwood boarding of any thicknesscomplete all as specified and directed(Note :- Old boarding shall be obtaind from item No -2) |
| 8 | S&F prepainted aluminium zinc steel sheet (galvalumebase) or thinknee0.50mmhaving tensile strength of 550 MPA , in colour and profile as apporved by GE and to be facotry moulded as in roof covering /cladding and fixed with hot dipped galvanished with high durable protective triple coated self tapping screws /self drilling serews, to suit the roofing in customizedcolour matching with the colour of roofing and screws are to be fixed using torque adjustable electronic gun screws drills of suitable capacity complete all as specified |
| 9 | S&F Pre-painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to waall , fixed self tapping screwscomplete all as specified and directed. |
| 10 | Dismantling floor, hearth , wall tiling including taking down plastering in cement mortor removing serviceable tiles to store and rubbish off the premises |
| 11 | M&L Virified tiles 8 to 10 mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and hite or coloured cement to match not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry over screed bed of 15 mm thick 1:6 and pointed in white or coloured cement to match as in floor etc , all as specified. |
| 12 | -ditto- all as per item ser No …. above here-in-before but in skirting/dado or verticle surfaces with back coat of screed bed or bedding layer of 10 mm thick 1:4 and pointed in white or coloured cement to match complete all as specified. |
| 13 | M&L Joint free Non - skid coloured ceramic tiles 7 to 10 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry over screed bed of 15 mm thick 1:6 and pointed in white or coloured cement to match complete all as specified. |
| 14 | M&L for 25 mm thickPCC 1:2:4,type B-0 (using 12.5 mm graded stone aggregate) as in levelling course complete where required all as specified and as directed . |
| 15 | Demolition of brick/PCC block work built in cement mortar all as specified |
| 16 | Material & Labour for brick work with sub class `B’ bricks, straight on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 17 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) any thickness, including cover fillets but without frame work. |
| 18 | Supply & fixing of powder coatedGI snap grid frame work for false ceiling comprising of the following sections for making partitions of 605x605 mm size fixedto walls with rawl plugs & screws and hanged to roof with and including 2mm dia GI wire suspender of suitable length and butterfly clips, sizeof main tee shall be 37mmx24mmx0.3 mm thick , cross tee shall be 28mmx24mmx0.3mm thick and wall angle shall be 24mmx24mmx0.3 mm thick including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting levelfixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified complete all as specified and directed. |
| 19 | Supply & fixing 4mm thick non asbestos E-board classic cememt building board for insulation and accoustic purpose, 600 x 600 mm size fixed with staples on snap grid as in ceiling complete all as specified and directed. |
| 20 | Supply & fixing pvc panelling made up of pvc hollow panels 25/30cm in width and 10MM thickness interlocking pattern of approved shed and design,fixed to wall for ceilling all as per the manufacturer instruction,fixed in repair ceiling complete all as specified and directed. |
| 21 | Taking down chowkats or frames exc 1.50 sqm but n.exc 4.00sqm each with shutters (without taking off shutters from the frames) complete.. |
| 22 | Supply and FixedPressed steel frames for doors with one or more rebates including necessary fixing lugs hinges ,lock stike plate etc, size 125 X 60 mm complete as specified. |
| 23 | M&L providing cement concrete (1:3:6) type C1 for filling in pressed steel frames and other similar items etc complete. |
| 24 | S&F 30mm thick Flush shutters with/without peep hole/vision panel, solid core construction, with block board core and plywood face panels, commercial type on both sides, both face are covered with decorative face veneer with lipping/frame to match all as specified and directed. |
| 25 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin VC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 26 | Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. |
| 27 | S & F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section |
| 28 | S&F 150 mm long aluminium handles cast type anodised. |
| 29 | S&F in repair 150 mm floor door stopper of aluminium alloy body and tonuge ,anodised, with hard drawn steel spring fixed in floor. |
| 30 | Supply & fixing butt hinges medium weight cold rolled mild steel of 100mm long complete all as specified and directed. |
| 31 | S&F in repair Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed. |
| 32 | Taking down chowkats or frames n.exc 1.50 sqm each with shutters (without taking off shutters from the frames) complete. |
| 33 | S&F three track aluminium powder coated sliding window with three sliding shutter, the size of outer frame three track 100 x 37 x 1.50mm (using two track for glazed window shutter and one track for wire gauged), the section shutter size 37 x 18 x 1.2mm) and glazing with 5 mm thick transparency glass of poly carbone including all around suitable rubber gasket and stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed on aluminium flat and inserted in the frame of shutter with tracking arrangement each sliding window shall be provided with one number handle including locking arrangement & 2 numbers sliding rollers of nylon with including all necessary fittings complete all as specified and directed. |
| 34 | S&F 18/19 mm thick Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination, fixed with screws to timber frame work |
| 35 | S & F 30mm wide Continuous (piano) hinges, mild steel, bright finish or elec trogalvanised |
| 36 | S&F 100mm Hasp and staple, safety type, Aluminium anodised, including bolt to hinge plate and fixed with screws complete all as specified |
| 37 | Taking up or down GI Water Tubing 15mm dia (bore) including Connections and Fittings, segregating serviceable Pipes & Fittings and Stacking properly at Site(s) for re-use, complete all as specified and as directed. |
| 38 | -ditto- all as per Item No. 37 here–in–before, but for 20mm dia (Bore). |
| 39 | -ditto- all as per Item No. 37 here–in–before, but for 25mm dia (Bore). |
| 40 | Supply and Laying Steel Water Tubing 15mm dia (Bore), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed. |
| 41 | -ditto- all as per Item No. 40 here–in–before, but for 20mm dia (Bore). |
| 42 | -ditto- all as per Item No. 40 here–in–before, but for 25mm dia (Bore). |
| 43 | Dismantling water tanks of capacity exc 500 but n.exc 1000ltrs complete. |
| 44 | Supply & Fixingrotational moulded polythene water storage tanks tripple layer(cylindrical vertical with closed top) hoisted and fixed in postion 1000 ltrs capacity with and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram complete all as specified and directed. |
| 45 | S&F in repair 15mm dia bib taps CP Brass with Capstanhead, screweddown, screwed for iron pipe of bore 15mm complete. |
| 46 | S&F in repairCP single lever wall mixer 3-in-1 system with provision for bath hand shower & overhaed shower complete with 115 mm long bend pipe connecting legs & wall flange (without hand & ober head shower) of make Jaguar cat part No OPP-15125PM or equivalent in Marc/Prayag/Parrywarecomplete all as specified . |
| 47 | S&F in repair brass Chromium plated Basin Mixer valve hot and cold screwed down for iron pipe complete . |
| 48 | S&F in repair Stop valves,15mm fancy type, chromium plated with long shank andcup (concealed type) cast copper alloy,screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed |
| 49 | S&F in repair Angle Cock,15mm fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 50 | Supply& Fixing Soap Dish CP Brass complete all as specified & directed.Make : Prayag or equivalent as approved by Engr-in-Charge |
| 51 | S&F toilet paper holder with flat recessed type stainless steel complete all as specified and as directed |
| 52 | Supply & Fixing Corner Glass Shelf 300mm (with ABS Brackets) 300 x 600mm complete all as specified & directed. |
| 53 | Supply& Fixing tubular towel Rail CP Brass, chromium plated D type with CP Brackets, 600 mm long between flanges all as specified. |
| 54 | S&F in repair Vitreous China EWC single peace with UF Soft Close Slim Seat Cover, Fixing Accessories, Accessories set and Cistern Fittings, Size: 370x670x720 mm, S Trap-300mm complete of make Jaguar Cat Part No:- LYS-WHT-38851PSM series or equivalent in Cera/Parryware/Hindwarecomplete all as specified and directed. |
| 55 | Supply & fix in repair Health faucet brass chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specifiedas approved by the GE. Make- Jaquar or equivalent |
| 56 | S&F in repair CP over head shower square shape of size 150x150mm of make Jaquar cat part No OHS-CHR-1619 with CP shower arm of size 400x25x25 mn Square shape for wall mounted showers flange of make Jaquar Cat partNo-SHA-455L400 or equivalent in Hindware/Prayag/Parrywarecomplete all as specified and directed. |
| 57 | S&F in repair CP Hand shower 24x24 mm sqaure shape single flow with Air effect (ABS body face plate chrome plated) with Rubit cleaning system of make Jaquar cat part No-HSH-35537 with flexible tube in chrome finish 1.5 m long with nuts of make Jaquar cat part No SHA-571 or equivalent in Hindware/Prayag/Parrywarecomplete all as specified and directed. |
| 58 | Supply & fix in repair Towel rack 600mm long with lower hangers, stainless steel of make Jaguar Cat Part No:-AKP-35781PS or equivalent in Marc/Prayag/Parrywarecomplete all as specified and directed. |
| 59 | S&F in repair 600x 450mm beveled edge mirror or selected quality glass mounted on 6mm thick AC bldg board or commercial plywood or frameless and fixed to wooden plugs with CP brass screws and cup washers all as approved by Engineer-in-charge. |
| 60 | Supply & Fixing Peg Set of 6 with base plate stainless steelcomplete all as specified by Engr-in-Charge |
| 61 | S & F in repair Stainless Steel grating 100mm dia complete all as specified. |
| 62 | S&F in repair PVC Connections 15mm size with PTMT Nuts of length 450mm/600mm and fixed, complete all as specified and as directed. |
| 63 | Taking down cement plaster on brick or stone walls etc raking out joints hacking for key scrabbing down water etc including taking out/removal of the all the tree routes from the brick surface/concrete surface complete all as directed. Note : Rate should be deemed included in the said items in the item rate. |
| 64 | Material and labour for 15mm thick cement plaster in CM (1:4) on fair faces of brick or concrete surfaces using WPC where ever requiredas per manufacturerer\"s instructions and finishing the surface even and smooth (without using extra cement) etc. incl finishing even and faircomplete all as specified NOTE -WPC shall be measured and paid separetely. |
| 65 | M&L for rendering 15mm thick on fair faces of brick work in CM 1:6 finished even and fair without using extra cement complete. |
| 66 | Supply only WPC complete all as specified and directed. |
| 67 | M&L for applying two coats of synthetic eneamel painting over a coat of pink primer on new wooden surfaces exc 10 cm width or girth including preparation of surfaces complete. |
| 68 | M&L for Preparing newly plasteredsurfaces and applying two coat of oil bound distemper over a coat of primer to wall to complete all as specified and as directed, |
| 69 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over any surfaces. Makes :- Nerolac -Excel, Asian - Apex, Berger - Weather coat antidust, Dulux - Weather shield. |
| 70 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) |
| 71 | S&F Mild steel sheet eaves gutters thickness of sheet 1.25 mm and dia 100mm, galvanised class 3, half round with rounded edge including brackets, heads, shoes, support etc complete all as specified and directed by Engineer-in-Charge. |
| 72 | S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge. |
| 73 | S&F 110mm PVC (SWR) bends any radius complete all as specified and directed by Engineer-in-Charge. |
| 74 | Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (below or above ground level). |
| 75 | M&L for 75mm Cement concrete Type C-2 1:3:6 (40mm graded aggregate) for plinth protection complete all as specified and directed by Engineer -in-Charge. |
| 76 | Dismantling floor, hearth or wall tiling incl. cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified. |
| 77 | M&L for PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 78 | Material & Labour for factory made precast (Rubber moulded) concrete designer chequered tiles any colour, shape and size not less than 20 cm x 20 cm x 25mm thick(compressive strength not less than 250 Kg/Sqm), set, jointed and pointed with grey cement and pigment over and including 20mm thick CM 1:6 screed bed or bedding layer complete all as specified and directed. |
| 79 | M & L forPCC 1:2:4type - B0 (using 12.5 mm graded crushed stone aggregate), as in coping, kneelers, perapets, apex stones and similar works incl necessary formwork complete all as specified directed by Engr-in Charge. |
| 80 | Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar workconforming to Fe.290.Gde-E-165 |
| 81 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement |
| 82 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 83 | M&L for PCC 1:3:6 type C-2 (40 mm graded aggregate) as in surface channels and drains including form work. |
| 84 | Extra for forming fair finished drain or channel 50 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed. |
| 85 | Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5 m in depth for foundation or manholes etc., and area n.exc. 10 Sq.m on plan and getting out in any type of soil (Hard/soft). |
| 86 | Demolition and breaking up drain pipes (SGSW, AC or RCC) of internal dia 150mm, set in cement mortar complete. |
| 87 | M&L for cement concete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes of 160mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 88 | Material and labourunplasticised PVC pipe 160mm dia type \"B\" with wall thickness 4mm (Min) of pressure rating 4 KN/Sqm laid in trenches and jointed with cement solvent including testing complete all as specified and directed. |
| 89 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concret 1:2:4 type B-1 smooth finished, and reforming benching as required, for internal dia of pipe 160mm complete all as specified and directed. |
| 90 | S&F in repair75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed ncluding necessary fittings like socket, bend, elbow, single/double tee etc in any length with rubber ring joints fixed with clamps of flat iron and including bolts and nuts and securing ends of stays to wall or roof and making good with cement mortor 1:3 or with PCC 1:2:4 complete all as directed. |
| 91 | S&Fixing in repair110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed ncluding necessary fittings like socket, bend, elbow, single/double tee etc in any length with rubber ring joints fixed with clamps of flat iron and including bolts and nuts and securing ends of stays to wall or roof and making good with cement mortor 1:3 or with PCC 1:2:4 complete all as directed. |
| 92 | Returning, filling in with approved soil obtained from excavation including spreading levelling, watering and well ramming in layers n.exc. 25cm thick. |
| 93 | Removing the excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. |
| 94 | Demolition of cement(Rainforced) Concrete of any description and in any position not other wise specifically provided |
| 95 | M&L Precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate ) for manhole cover septic tank covers slabs etc including necessary form work and set in CM (1:4). Note:- reinforcement will be measured and paid seperately. |
| 96 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 97 | Surface dressing n exc 15 cm deep in hard/dense soil and Clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth,roots, and trees not exceeding 30 cm girth |
| 98 | Excavation of trenches n exc 1.5m wide and n exc 1.5m deep for foundation etc. and getting out in hard/dense soil |
| 99 | M&L Plain cement concrete type D2 1:4:8 (usingh 40 mm graded granite stone aggregate) in foundations, filling and mass concrete. |
| 100 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter |
| 101 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions |
| 102 | M&L for RCC M-25 in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete |
| 103 | M&L for RCC M-25 in Columns, pillars, piers, posts and struts. |
| 104 | M & L for mild steel TMT bars , 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length , bent to shspe required incl cranking , bending spirally for hooping for coloumns , hooking ends andbionding with (annealed) not less than 0.90mm dia all a specified and directed |
| 105 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exceeding 6 mtr mean radius and built in CM 1:4 complete. |
| 106 | M&L Preparation of new plaster surface applyingtwocoats cement base paint over a coat of primer onwalls. |
| 107 | S&F Post & strut in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165. |
| 108 | S&F Galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolt including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc. |
| 109 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed |
| 110 | M&L for Framed work as in doors or gates of Fe-290 (Gde E 165) angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, tc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed |
| 111 | M&L for preparing of new steel surfaceexceeding 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer. |
| 112 | Taking down carefullyaluminium/copper wiring of any size (for light, fan, socket or power etc complete) including fixture and fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc and making good disturbed surfaces of wall, roof etc to match with existing surface. |
| 113 | Supply & Fixing point wiring for one light point/ fan / Exhaust fan (independent) point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS)PVC cable drawn into & including medium grade PVC conduit (not less than 20mmouter dia ) with all fittings and accessories fixed concealed(including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) andsunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washersincluding one continuous run of PVC insulated (green colour) 1.5 Sqmm multistrandedcopper conductor cable earth wire and connected to earth dolly complete all as specified and directed Note:- wiring shall be done in colour coding as directed by Engineer in charge |
| 114 | All as per item No. 113 herein before but one socket outlet 5 Amps on the same board. |
| 115 | All as per item No. 113 herein before butone 3 pin socket outlet 5 Amps independent. |
| 116 | All as per item No. 113 herein before butone bell point controlled by one bell push switch. |
| 117 | All as per item No.113 above but with 2.5 Sq mm two single core and 2.5 Sq mm one single core as earth wire for 15 Amps socket. |
| 118 | All as per item No. 113 above but with 4.0 Sq mm two single core and 2.5 Sq mm one single core as earth wire forGyser Point. |
| 119 | Supply and fixing of following rating of modular type ,white polycarbonate,switches, sockets, fan regulator suitable for250V, AC, 50Hz.Electrical supplyand as directed by Engr-in-Charge. (a) 6 Amp one way switch, 1 module |
| 120 | (b) 6 Amp 2/3 Pin combined socket shuttered, 2 module |
| 121 | (c) Modular Switch 1 way 16 Amp, 1 Module |
| 122 | (d) Modular socket 6A/16Amp, 2/3 pin combined, 2 Module |
| 123 | (e)6 Ampbell push switch modular type |
| 124 | Supply and fixing of following sizes of modular front plates, white with frame on existing boxes complete as required.(a) 2 Module |
| 125 | (b) 3 Module |
| 126 | (c) 4 Module |
| 127 | (b) 6 Module |
| 128 | (c) 8 Module |
| 129 | Supply and fixing anodised rust proof 18 SWG MS box, flush type offollowing sizes (to be of same make as modular switches and sockets)to berecessed in wall/gypsum partition complete as required :- |
| 130 | Supply and fixing anodised rust proof 18 SWG MS box, flush type offollowing sizes (to be of same make as modular switches and sockets)to berecessed in wall/gypsum partition complete as required :- (a) 75mm x 105mm x 50mm deep (1-2 Module) |
| 131 | (b) 75mm x 105mm x 50mm deep (3 Module) |
| 132 | (c) 75mm x 105mm x 50mm deep (4 Module) |
| 133 | (d) 75mm x 210mm x 50mm deep (6-8 Module) |
| 134 | Supply and fixing bell electric multi musical type AC 230 volts, 50 Hz. |
| 135 | Material and labour for Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to and including Rigid non metallic PVC conduit ( ISI marked) Heavy grade, 20 mm dia (external) inclusive ofjunction/terminal boxes, all fittings and accessories fixed concealed with and including 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DBincluding cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existingold sub main wiring complete all as specified.Note :1 The cost of earth wire is included in the quoated rates. 2.Two run of 6 sqmm, one run of 4 sqmm and one run of PVC conduit will be measured as one unit ie one running metre” |
| 136 | S&F ceiling rose surface bakelite3 terminal with base plate. |
| 137 | Supply and fixing LED lights fitting 1x 20W (warm/milky white as required on site), 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and life of tube light not less than 50,000 hours.completeall as specified and directed..Make Havells cat pat LUMILINEBS20WLED865SPCWH or equivalent of phillips/wippro/Bajaj/Surya complete Note:- LED tube light shall be purches to get minimum 2 year warrenty of material from manufracturer. |
| 138 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible opper conductor cable of suitable size complete |
| 139 | S&F lamp holder (modular type) PVC insulated body with back plate for angle/battern fitting with and including one No 10 watt LED lamp all as specified and directed. |
| 140 | S&F Bed side lamp with 10 watt LED lamp |
| 141 | S&F Polycarbonate D.P. switch with Pc Key ring Tag 2 Module,white,32 Amp,240 volts |
| 142 | Taking down by disconnectining exixting electric meter andrefixing including nacessary connection upto 25 amps |
| 143 | Supply & Fixingsheet metal enclosure forSPN DBs (double door type) Single pole and neutral 12 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 144 | Supply & Fixingsheet metal enclosure forSPN DBs (double door type) Single pole and neutral 8 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 145 | Supply & Fixing 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN 40 to 63 Amp and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed . |
| 146 | Supply & Fixing 240V, 10KA \"B\" curve miniature circuit breaker (MCB) of single pole 5 to 32 Amp and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed . |
| 147 | Supply and Fixingpropeller type AC ventilating fans 230 volts, 50 C/S heavy duty 1200 RPM, 300 mm sweep (Exhaust fan) made ofsturdy Engineering plasticcomplete with louvers shutter, and including PVC insulated three core white 23/.0076 copper cable, rubber insulated from ceiling rose to exhaust fan motor complete all as specified and directed. |
| 148 | Supply and fix water heater storage type electric supplied and installed complete of capacity 25 ltrs including making connection with industrical socket, ultra thick SS inner tank of superior 304 grade, Fire retardant ISI Mark supply cord, Rust & shock proof ABS body, Compact & easy to install and proper hanging on nut bolts washers grouted on wall and PVC pipe for connection of hot and cold water complete all as specified and directed by Engr-in-charge.Make - Bajaj/orison/Havells and equivalent make as specified in particular specifications. |
| 149 | S&F sheet metal enclosure with socket plug top and MCB single pole and netural enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amp 240 Volts complete. |
| 150 | S & F LED light fitting 1X10Wbulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. |
| 151 | M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross section area 16 Sqmm 2core laid in trenches or passing through pipes/ducts and incl the disturbence surface of road making good with using PCC complete all as specified and directed. |
| 152 | M&L for dry clean sand filling in trenches below and around under ground cable cushioning complete all as specified and directed.. Note :-Thickness of sand cushioning shall be measured after punning. |
| 153 | M&L for brick sub class \"B\" for protection of cable comlete all as specified and directed. |
| 154 | Supply and Fixing steel tube Light grade galvanised 50 mm bore with all fittings for protection of UG cable under road/culvert and fixing on wall with saddle, screw complete all as specified and directed. |
| 155 | Supply & Fixingsheet metal enclosure forSPN DBs (double door type) Single pole and neutral 12 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |