| 1 | Excavation of foundation in Hard soil within 50m initial lead and 1.5m initial lift |
| 2 | Filling Foundation and plinth with well graded sand including watering and ramming |
| 3 | Cement Concrete(1:4:8)with40 mm size Hard Granite Metal |
| 4 | 2.50cm thick A.S.flooring with cement concrete(1:2:4) with 12mm size H.G.chips including cement punning |
| 5 | Brick work with FLY ASH bricks inC.M(1:6) in foundation and plinth (Septic Tank) |
| 6 | Brick work with FLY ASH bricks inC.M(1:6) in foundation and plinth |
| 7 | Brick Work with Fly Ash Bricks having crushing strength 75kg/sq.cm in cement mortar (1:6) in Super Structure |
| 8 | RCC Work M-20 grade with 20 mm and down grade HG chips (CB) including hoisting,lowering & laying concrete and compacting |
| 9 | Plinth Band and Column Base |
| 10 | Column and Beam |
| 11 | Lintel |
| 12 | Chajja |
| 13 | Straightening,Bending,Binding of M.S.Rod including cost of rod,Binding wire and transportation |
| 14 | 16 mm thick cement plaster in C.M(1:6)over Stone work |
| 15 | 16mm thick cement plaster in C.M(1:6)over brick work |
| 16 | 12 mm thick cement plastering C.M. (1: 6) |
| 17 | 6mm thick cement plaster in C.M(1:4) R CC surfaces |
| 18 | Priming 1 coat with any approved Primer |
| 19 | Finishing walls with Plastic Emulsion paint of approved shade two coat to give an even shade including cost of paint |
| 20 | Finishing walls with weather coat paint of approved shade two coat to give an even shade including cost of paint |
| 21 | Supplying of MS Doors of windows |
| 22 | Priming one coat with any approved red oxide over steel work. |
| 23 | Paining 2coats with any approved iron paint on new iron work. |
| 24 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips.On new work |
| 25 | Supplying fitting and fixing of FRP door frame of size 75X100mm including drilling holes in Masonry walls Data for door |
| 26 | Supplying fitting of Factory made single Leaf Regid FRP composite door Shutter of 32mm thick,Laminated with GRP skins with wood grain finished fabricates using UV stabilised Isopthalic Gel Coat and layer of 450gsm E-glass chopped strand mat(csm) impregnated with Orthopathalic,Polyster resin including fitting all fixtures like hinges,towerbolt,handle,aldrop with cost,conveyance and taxes of all materials and labour complete. |
| 27 | Filling Foundation and plinth with Excavated Earth |
| 28 | Electrical Works |
| 29 | Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V piano type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex / L&T / Anchor / Havels / V Guard ) (Cost for 1 point) |
| 30 | Group-A |
| 31 | Group-B |
| 32 | Recessed wiring for light / power plug with 4 x 4 sq.mm FRPVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit along with 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing as required. (Make of wire Finolex/L&T/Ancho /Havells/V Guard ) |
| 33 | Recessed wiring to sub-main in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth as required. (Make of wire Finolex/L&T/Anchor/Havells/VGuard) (Cost for 50 m) |
| 34 | Supplying and fixing of 16 / 18 SWG metal box of following sizes (nominal size) on surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required. (100 mm x 100 mm x 60 mm deep) |
| 35 | Supplying and fixing of following piano type switch / socket on the existing switch box / cover including connections etc as required. (3 pin 5 / 6 amp socket outlet) |
| 36 | Supplying and fixing of following piano type switch / socket on the existing switch box / cover including connections etc as required. ( 6 pin 15 / 16 amp socket outlet) |
| 37 | Installation,Testing and Commissioning of pre-wired fluorescent fiiting /compact fluorescent fitting of all types, complete with all accessories and tube etc. including supplying and fixing ball socket arrangement, 2 no down rods of 20 mm dia x1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with1.5sq.mm FR PVC insulated single core mult istrand copper conductor and earthing etc. as required. |
| 38 | Installation,Testing and Commissioning of pre-wired fluorescent fiiting /compact fluorescent fitting of all types, complete with all accessories and tube etc. including supplying and fixing ball socket arrangement, 2 no down rods of 20 mm dia x1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with1.5sq.mm FR PVC insulated single core mult istrand copper conductor and earthing etc. as required. |
| 39 | Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto30cm) with1.5sq.mm FR PVC insulated single core multistrand copper conductoretc. including providing and fixing phenolic laminated sheet steet cover on the fan box etc as required. |
| 40 | Installation,Testing and Commissioning of resistance type ceiling fan regulator, in existing switch box including connection with 1.5sq.mm FR PVC insulated single core multistrand copper conductor,earthing the regulator as required. |
| 41 | Installation, testing and commissioning of 200 mm (8 inch) Exhaust Fan for Bathroom in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required. |
| 42 | Providing and fixing of following capacity TP & N disconnector fuse switch unit inside existing cubical panel board with ISI marked HRC fuses including drilling holes in cubical pannel, making connection etc as required. |
| 43 | Supply and fixing of single pole MCB with sheet steel enclosure, distribution board, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ ISOLATOR) (4 WAY, DOUBLE DOOR) |
| 44 | Supply and fixing of 5 amp to 32 amp rating 240 V \"B\" series miniature circuit breaker suitable for lighting and other loads of the following poles in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required (SINGLE POLE) |
| 45 | Supply and fixing of following rating double pole 240 V isolator in the existing MCB DB ISI marked complete with connection testing and commissioning etc. as required. (40 amp) |
| 46 | Supply, Installation, Testing, and Commissioning of 32 Amp DP Main switches of following capacity (IS 13940 Part 3/1993 ) on existing surface / wall mountnting and complete with HRC Fuse links, interconnections, earthing, etc. as required as per direction of Engineer in Charge. Make SEIMENS/ HPL/ ANCHOR/ L&T/ HAVELS/ C & S/ RK (32 Amp DP) |
| 47 | Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required. |
| 48 | Extra for using salt and charcoal for G.I or copper plate earth electrode as required |
| 49 | PH and Sanitation |
| 50 | Providing and fixing to wall or ceiling and floor pvc pipes class conforming to ASTM-D 1785/89(Sch-80) and pipe fittings of thefollowing nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification complete. |
| 51 | 15 mm dia PVC Pipe |
| 52 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes &fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge |
| 53 | 15 mm dia CPVC Pipe |
| 54 | Cutting holes through existing brick work including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc all complete as per specification. |
| 55 | Fixing of Brass Screw-down Bib Cocks (Taps) polished bright conforming to IS:781-1995 of the following nominal sizes as per specification complete. |
| 56 | 15 mm dia C.P. Brass long body Bib cock |
| 57 | 15 mm dia C.P. flanges (Small) |
| 58 | 15mm dia CP extension piece - 25mm long |
| 59 | Fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position etc all complete as per specification and direction of the Engineer in charge |
| 60 | 500 litre capacity 3 - Layer White Rotational Moulded Cylinderical Vertical water storage tanks (ISI marked) |
| 61 | Providing and fixing on wall face unplasticised Rigid PVC soil, waste and rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes |
| 62 | 110 mm dia U-PVC SWR pipes |
| 63 | Providing and fixing on wall face unplasticised-PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion |
| 64 | 110 mm dia P.V.C. SWR door bend 87.5° |
| 65 | Single tee without door 110x110x110 mm |
| 66 | 110 mm dia P.V.C. SWR plain bend 87.5° |
| 67 | 110 mm dia PVC SWR coupler |
| 68 | PVC vent cowl 110 mm |
| 69 | Laying in trenches High Density Polyethylene Pipes conforming to IS 4984 - 1995 and Specials of following outside diameter and Class-1 to Class-3 and jointing by Fusion welding method including testing as per specification complete. (Earth work in trenches to be measured and paid for separately). |
| 70 | 110 mm dia H.D.P.E Pipe P.N. 6.0 |
| 71 | Fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap conforming to IS 2556 : Part 8-2004, to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification. |
| 72 | White Vitreous China EWC Pattern with \"P\" Trap |
| 73 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 74 | Fixing wash basins with hole for pillar taps conforming to IS 2556 : Part 4-2004 with Cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification. |
| 75 | Fixing C.P. grating complete as per specification Please Enable Macros to View BoQ information |