| 1 | Earth work in excavation of foundation trenches in HARD soil up to the required depth including dressing and leveling the bed and depositing the excavated materials away from the site with all leads and lifts, T&P labour required for the work etc. complete as directed by the Engineer-In Charge. |
| 2 | Supplying and filling in foundation and plinth with sand including well watering, ramming, including cost, conveyance and royalities of all materials and cost of all labour with T&P required for the work etc. complete as per direction of Engineer-In-Charge. |
| 3 | Cement concrete (1:3:6) in foundation and plinth using 4 cm. size hard granite crusher broken metal of approved quarry and approved quality including hoisting lowering laying concrete in layers not exceeding 0.15 M. in depth including compacting watering and curing etc, complete including cost ,conveyance, royalities & of all materials and cost of labour etc with T&P required for the work etc. complete as per specification & direction of Engineer-In-Charge. |
| 4 | Filling in foundation and plinth with excavated materials including water and ramming as directed by the Engineer-in-charge |
| 5 | RCC work M-20 having a minimum compressive strength 200kgs/cm2 in 15cm.cubes at 28 days after mixing and tests conducted in accordance with IS.456 and IS.516 using 12mm.to 20mm. size black hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting lowering laying and compact concrete by using vibrator watering and curing for 28 days centering shuttering and finishing the exposed surface smooth providing grooves or beads where necessary including cost, conveyance ,royalities & testing of all materials and cost of all labour with T&P required for the work etc. complete in all respect as per specification & direction of E.I.C.(but excluding cost of M.S Rod or Tor Steel & binding wires) |
| 6 | Column Base & Footing |
| 7 | Plinth Band |
| 8 | Column up to Slab |
| 9 | Lintel Bend |
| 10 | Chajja |
| 11 | Roof Beam |
| 12 | Roof Slab |
| 13 | Stair Case |
| 14 | Cutting straightening HYSD Bars/High tensile tor steels, confirming to FE -500 grade bending binding welding and jointing if necessary and tying the grills and placing in position as required for RCC work and for providing fan hooks hoisting lowering and laying including cost, conveyance of HYSD bars/High tensile tor steels and binding wires of 18 to 20 gauge and labour required for the work for bending binding and tying the grills in all floors etc. complete as per direction of E.I.C(Measurement will be taken excluding cost of binding wire)and payment will be made on the weight of M.S or tor steel only). |
| 15 | Fly Ash Brick masonary in C.M.(1:6) using Fly Ash .Bricks of size 25cm.x12xm.x 8 m. having crushing strength not less than 75 kgs./cm2 after immrersing the bricks for six hours in water before use in Foundation & Plinth including splays cutting, circular moulding corbelling, champhering and similar such type of works with watering and curing etc .including cost, conveyance, royalities and & testing of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-In-Charge. |
| 16 | Fly Ash Brick masonary in C.M.(1:6) using Fly Ash .Bricks of size 25cm.x12xm.x 8 m. having crushing strength not less than 75 kgs./cm2 after immrersing the bricks for six hours in water before use in Superstructure including splays cutting, circular moulding corbelling, champhering and similar such type of works with watering and curing etc .including cost, conveyance, royalities and & testing of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-In-Charge. |
| 17 | Fly Ash Brick masonary in C.M.(1:4) using Fly Ash .Bricks of size 25cm.x12xm.x 8 m. having crushing strength not less than 75 kgs./cm2 after immrersing the bricks for six hours in water before use in Superstructure including splays cutting, circular moulding corbelling, champhering and similar such type of works with watering and curing etc .including cost, conveyance, royalities and & testing of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-In-Charge. |
| 18 | Supplying fixing and fittings Steel Angle, Iron door and widow, of approved design and drawing including cost conveyance royalty and taxes of all materials all labour T&P required for the work complete (payment will be made on weight basis only) |
| 19 | Providing 6 mm thick C.P with C.M(1:4) with screened and wshed sand for mortar and finished smoothto RCC work after closed deep chipping and slurry treatmenr including watering and cutting etc comp. in all respect as dircted by the Engineer in charge |
| 20 | 16mm.thick cement plaster(1:6) finished smooth surface of walls after racking out the joints including watering and curing with cost ,conveyance, royalities of all materials and cost of labour with T&P required for the work etc. complete as per direction of Engineer-In-Charge. |
| 21 | 12mm.thick cement plaster in C.M. (1:6) in finished smooth to surface of walls after racking out the joints including watering and curing with cost ,conveyance, royalities of all materials and cost of labour with T&P required for the work etc. complete as per direction of Engineer-In-Charge. |
| 22 | Providing and laying Vitrified floor tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand ) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights |
| 23 | Providing and laying Vitrified skirting tiles 600x600 mm DADO (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand ) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights. |
| 24 | Providing & laying enti-skid ceramic glazed floor tile 600x600mm (thickness to be specifyed by the manufacture)fisrt quality comforming to (IS.1622 of NITCO/SOMANI/ASIAN/KAJERIA or equivalent approved make in all colours & shade except white. |
| 25 | Providing and fixing 1st quality Ceramic Digital wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) minimum thickness 5mm of JOHNSON,KAJARIA,RESTILE or equivalent approved make in all colours, shades except burgundy, bottle green, black of size 600x300 in skirting and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete as per direction of Engineer-In-Charge in all floors and all heights |
| 26 | Providing 2.50 cm thick A.s flooring with cement concrete (1:2:4) using 12 mm size black hard grinite crusher broken chips and screened and washed sharp sand for mortar and finished smoothmto therough surface of floor and punning watering and curing etc. complete in all respect as directed by the Engineer - in - charge |
| 27 | Supplying fitting, fixing fully glazed aluminum framed openable windows using 15 micron anodized OEL aluminum section 2082 as out section, 9139 as mullion section, 4124 as a shutter section frame with tapered clip of section 4125, aluminum angle , rubber beading, friction stay and handle etc. with 5mm black glass. |
| 28 | Providing fitting, fixing of Aluminium Door with OEL anodized Al. door section of 9202 as vertical member, 9200 as top and bottom member. 9232 as middle member 12mm thick pre-laminated board fixed on door frame by means of tapered clip No. 4660 and the frame to be completed by means of jointing angle No. 1855 with Automatic Door closure, 6 Lever MORTICE Lock, Door Stopper, Handle etc. including all cost of labour, T&P, hire charges of drilling machine, labour charges etc. complete as per direction of Engineer-in-charge |
| 29 | Supply fitting and fixing MS grill of Approved desing to be fixed in RCC colum and Brickwork shall be made of MS Angle & MS square bar ,MS plates of requiredsize with necesaary welded clamps fixed in position , |
| 30 | Wall Painting one coat to wall with primer of Approved shade on new to given an even shade including all cost conveyance etc complete. |
| 31 | Finishing wall surface of wall with Acryllic wall putty (water based)of Approved make and finishrd smooth and even surface to recive painting including cost of scafolding stagging charges with cost of all material taxes T& P etc . |
| 32 | Wall painting two coats with plastic emulsion paint of approved shade on ned work to give an even shede including cost of bruses and putty inlcuding acost of paint of approved shade as per the instruction of manufacture giving uniform shade etc in all highest of wall etc inlcuding interior wall primer ad providing scafolding cleaning curing and supply of all materils and labour complete as per drawing desing and direction of Arcitech as Engineer in charges. |
| 33 | Painting 2 coats with water proofing weather coat of approved shade by means of brush to outside surface of walls complete in all floors with cost, carriage and all taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respect as per direction of the Engineer – in – Charge. |
| 34 | Providing & painting two coat swith approved Enamel paint on new wood /iron work as per the instruction of Engineer-in-charge at all elevation including all material & labour complete. Please Enable Macros to View BoQ information |