| 1 | ABC |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with piano type switch, phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. asrequired. Group C |
| 3 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. Group C |
| 4 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 amp switch |
| 5 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 amp socket outlet |
| 6 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recessed including painting etc as reqd in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.(A) 25 mm |
| 7 | (B) 20 mm |
| 8 | S/D following size of FR PVC insulated copper conductor 1 core cable in existing surface/recessed /PVC/ Steel conduitas reqd.(a) 3x2.5 sq mm |
| 9 | (b)6X2.5 sq mm |
| 10 | (c)3X 4 sq mm |
| 11 | ( d ) 6x4 sqmm |
| 12 | Supplying and fixing metal box of 250 mmx300mmx60mm deep (normal size)of surface or in recess with suitable size phenolic laminated sheet cover in the front i/c Painting etc as reqd |
| 13 | Supplying and fixing metal box of 180mmx100mmx60mm deep (normal size)of surface or in recess with suitable size phenolic laminated sheet cover in the front i/c providing and fixing 6pin,5/6 amps and 15/16amps socket outlet and 15/16amps piano type switch connection painting etc as required. |
| 14 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a)12 way Double door |
| 15 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 16 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 63 amps |
| 17 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 100 amps |
| 18 | Laying of one no PVC insulated and PVC sheathed/XPLE Al Conductor armoured power cable of 1.1KV grade of following sizein the existing masonry open duct as required. Upto 35 sq.mm |
| 19 | Laying of one no PVC insulated and PVC sheathed/XPLE Al Conductor armoured power cable of 1.1KV grade of following sizeon wall surface as required. Up to 35 sq,mm (clamped with 1mm thick saddle) |
| 20 | Supply of XLPE insulated and PVC sheathed aluminium conductor armoured cable of 1.1KV grade conforming to IS-7098 (a) 2x10 sqmm |
| 21 | (b) 4x25 sqmm |
| 22 | Earthing with GI Earth pipe 4.5longx40mm dia i/c accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc (but without charcoal or coke and salt) complete as required. |
| 23 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 24 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 25 | Supply and fixing 3mm thick phenolic laminated sheet i/c cutting of sheet, bolt and washer etc as required. |
| 26 | Supply of 12\" ( 300mm sweep) exhaust fan heavy duty complete withshutter, bladesetc as required |
| 27 | Supplying, installation, Testing & Commissioning of 18-22 watt LED surface mounted Batten light of following body material and construction as per IS : 10322 withdriver (Replaceable) as per the requirementwith Driver efficiency >85% ,Operating voltage AC140-270 Volt,freq 50/60 hz, Operating temp range 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI>80,Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), ofminimum 50000BurningHourswith,70%ofinitial Lumenmaintained tilllife ends,CCT3000°K/ 4000°K / 5700°K/6000°K/ 6500°K(AsperANSIBin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BISstandard andtrade markcertificate(T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own inhouseNABLlabsetupforalltestingfacilitiesforLEDfixtures.completeinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy>135lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineerin-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90.C Powdercoateddiecast/Extruded aluminumBody (Thickness ≥ 1.20 mm |
| 28 | Supplying, installation, Testing & Commissioning of36W Panellight 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirementwith Driver efficiency >85%, Operating voltage AC140270 Volt,freq50/60hz,Operatingtemprange-15degto40degcentigrade,internalsurge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95,IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free,(flicker should be below 5 %), life time (LED,Driver & electrical circuitry),of minimum50000 Burning Hours with , 70% of initial Lumenmaintained tilllife ends ,CCT 3000°K /4000°K /5700°K /6000°K/6500°K(As perANSI Bin), SDCM(Standard Deviation Color Matching) <3,Maximumpower consumption should not more than the specified rating and Fixture shall be of relevant BIS standard andtrade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ EmbossingScreen printing on housing. completeinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy>135lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C) |
| 29 | Supplying,installation,Testing&Commissioningof100 watt FloodLight, powdercoatedpressuredie cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%,Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95,IP-66,IK-10,CRI>80,undervoltageandovervoltageprotection, EMI-EMCasper CISPR-15,lenses for beam angle 30 deg120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumenmaintained tilllife ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K/6000°K/6500°K(AsperANSIBin), SDCM(Standard Deviation Color Matching) <5, Maximumpowerconsumptionshouldnotmore than the specified rating and Fixture shall be ofrelevant BIS standardcompleteinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy>135lm/Wat output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C) |
| 30 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan withBrush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2nos. canopies, shackle kit, safetyrope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85,Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remainingaccessories including safety pin,nut bolts, washers, temperaturerise=75 degree C (max.), insulation resistance more than 2 mega ohm,suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc.complete as required. |
| 31 | SITC of metal clad poeder coated compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminium bus bars supports interconnection erection of switcgears with depth 30 cm to 60 cm and making provision for termination of incoming /outgoing cables/bus ducting and making foundation etc as reqd. ( Suitable for 40Amp TP&N) |
| 32 | Providing and Fixing 600 mm sweep aircirculator complete with blades jaal workable on 220/240 volts AC supply etc as reqd |
| 33 | Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.(a) 100 Amp16 KA, TPMCCB |
| 34 | (b) 200 Amp, 25KA, FPMCCB |
| 35 | supply and fixing of 4.5 KG DCP with CO2 gas cartridge fire extinguisher (conforming to IS:2171 with cylinder fully charged) |
| 36 | OD23032/2023-2024:Supply and fixing of ABC gascartige fire extinguisher ( with cylinder fully charged |