| 1 | R.C.C. work M-20 grade using 20mm.and down grade HBG crusher broken chips including hoisting,laying, cost,conveyance and royality of materials curing including centering and shuttering etc. complete as per direction of Engg-in-Charge . |
| 2 | Supplying,fitting and placing uncoated HYSD bar reinforcement as per drawing and technical specification including cost,conveyance and all taxes of steel and binding wire etc.complete as per direction of Engg-in-Charge . |
| 3 | Brick work with Fly Ash .Bricks having crushing strength between 100kg/sq.cm to 149kg/sq.cm in c.m. 1:6 in Sup.Str. including cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge . |
| 4 | 12mm. thick cement plaster in c.m. 1:6 over brick masonry including cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge . |
| 5 | Ground floor |
| 6 | First floor |
| 7 | Second floor |
| 8 | Removing cement plaster from wall including racking joints 12mm deep and removing the debris within 50mt.Lead etc. complete as per direction of Engg-in-Charge . |
| 9 | Ground floor |
| 10 | First floor |
| 11 | Second floor |
| 12 | Wall painting two coats on new work with Weather coat paint of approved shade with water bound primer as per direction of Engg-in-Charge . |
| 13 | Ground floor |
| 14 | First floor |
| 15 | Second floor |
| 16 | Wall Priming one coats on new work with wall water bound primer of approved shade as per direction of Engg-in-Charge . |
| 17 | Ground floor |
| 18 | First floor |
| 19 | Second floor |
| 20 | Distempering two coats to walls with distemper of approved shade to give an shade excluding cost of distemper. |
| 21 | Ground floor |
| 22 | First floor |
| 23 | Second floor |
| 24 | Supply and fixing of MCM Modified Clay Material - cut stone R04 -1200 X 600 MM ,THICKNESS-2.5 MM x 3 MM PHOMI make as per company standard dimension, pattern, colour as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation - Class A— ASTM E84- 15. The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in-charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge. |
| 25 | Removing old grading plaster from roof slab, cleaning the surface, lowering and removing the debris within 50m lead etc complete as per direction of Engg-in-Charge . |
| 26 | 4cm.thick grading concrete (1:2:4) on roof slab using 12mm.& down grade size CBHG chips including cost,conveyance and royalty of materials curing etc.complete as per direction of Engg-in-Charge . (For old work) |
| 27 | Iron work wrought and put up in trusses and record racks |
| 28 | Supply fitting and fixing of 0.450mm thick of size 1072mm x 3050mm \"DURASHINE\" Corogatted Sheet in in roof drilling hole in wind ties including fixing of ridges valleys wind ties etc. including cost of fitting as per direction of Engineer-incharge. |
| 29 | First floor |
| 30 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers,handles, including applying a priming coat of approved steel primer.handles, including applying a priming coat of approved steel primer. |
| 31 | Supplying and fixing of Roller blinds by fixing powder coated top channel, bottom channel with bottom end cap, control unit and good quality of 0.60 mm thick fabric of approved design and quality etc.complete. |
| 32 | Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures |
| 33 | Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead |
| 34 | Ground floor |
| 35 | First floor |
| 36 | Fixing of ceramic tiles in floors, treads or steps and landing of steps on 25mm thick cement plaster in mortar (1:1) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles per 1 sqm |
| 37 | Ground floor |
| 38 | First floor |
| 39 | Fixing granite tiles of 0.10 Sqm. & upto 0.4 Sqm. (10mm. thick) in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades includind cost for rubbing, poloshing complete excluding cost of tiles etc. complete as per direction of Engg-in-Charge . |
| 40 | Supplying fitting & fixing the following H.C.I./ P.V.C S.W.R pipe & fittings as per PH specification & direction of EIC. |
| 41 | 110mm dia PVC SWR Pipe |
| 42 | Providing and fixing to wall or ceiling and floor pvc pipes class conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification complete. |
| 43 | 75 mm dia pipe |
| 44 | 75mm diaP.V.C. SWR door bend 87.5\" Each |
| 45 | 75mm dia PVC SWR Plain Bend |
| 46 | 75mm dia PVC SWR 45 degree Plain Bend |
| 47 | 75mm dia PVC SWR PIPE CLIP |
| 48 | Cutting holes through brick masonry wall for taking Sewer line & making good the damages. |
| 49 | Fixing wash basins with hole for pillar taps confirming to IS 2556: Part 4-2004 with Cast Iron or M.S. brackets painted white including cutting holes in walls and making good the damages etc. all complete as per specification including CP waste, Waste Pipe & 15mm dia connection pipe. Please Enable Macros to View BoQ information |