| 1 | Foundation excavation in hard soil including levelling and dressing the bed and sides depositing muck within initial lead and lift etc. complete as per direction of Engg-in-Charge . |
| 2 | Filling foundation and plinth with sand well watered and rammed including cost,conveyance and royality of sand etc. complete as per direction of Engg-in-Charge . |
| 3 | Cement Concrete (1:2:4) with 12 mm size broken hard granite chips for R.C.C. works including hoisting and laying etc. complete as per direction of Engg-in-Charge. |
| 4 | C:C(1:4:8 ) with 40mm size crusher broken hard granite metal including all costs carriage, royality and curing etc all complete. |
| 5 | R.C.C. work M-20 grade using 20mm.and down grade HBG crusher broken chips including hoisting,laying, cost,conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge . |
| 6 | column base |
| 7 | soakpit slab |
| 8 | Supplying uncoated HYSD bars for reinforcement including all costs, carriage and all taxes etc all complete. |
| 9 | Brick work with Fly Ash Bricks having crushing strength 75 kg/sq.cm in c.m. 1:6 in F & P including cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge . |
| 10 | 16mm. thick cement plaster in c.m. 1:6 over brick masonry including cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge . |
| 11 | Enamel Painting two coats with enamel paint over one coat of primer of approved quality etc. complete as per direction of Engg-in-Charge . |
| 12 | Iron work wrought and put up in trusses and record racks |
| 13 | Supply fitting and fixing of 0.40mm GCI. Sheet in in roof drilling hole in wind ties including fixing of ridges valleys wind ties etc. including cost of fitting as per direction of Engineer-incharge. |
| 14 | Ground floor |
| 15 | First floor |
| 16 | 10 cm thick dry brick khoa backing in soakpit. |
| 17 | Removing and again fixing of ACP panels after PH works. |
| 18 | Inspection of electric wiring and control panel board by wireman |
| 19 | Unskilled |
| 20 | Wiring for circuit/sub main wiring alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked confirming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduct 1.6mm in recessed PVC conduit as required (Make of wire-Finolex/L & T /Anchor/Havels/V-guard) |
| 21 | do- 2x2.5sqmm +1x1.5sqmm(1.8.2) |
| 22 | 2x4sqmm +1x1.5sqmm(1.8.3) |
| 23 | S/ F of 18-25 LED single strip type tube light fitting ( make-Havells/Philips/ Crompton / Polycab/PAC/ HPL) |
| 24 | Providing and fixing of lightning conductor finial made 25 mm dia x 3mm long copper with base plateincluding holes etc complete as directed by the engineer in charge. |
| 25 | Providing and fixing testing joint, made of 20 mm X 3 mm thick copper strip, 125 mm long, with 4 nos. of tinned brass bolts, nuts, chuck nuts and spring washers etc. complete as required |
| 26 | standard earthing as per govt spn. |
| 27 | S/F of Cu. Earth Plate Earthing 600mmx 600mm x 3.15 Without Salt & Charcol (3.5) |
| 28 | S/F of 8 SWG Copperwire for loop earthing(3.18) |
| 29 | S/f of salt & charcoal for Plate Earth electrode(3.6) |
| 30 | Providing and fixing on wall face unplasticised-Rigid PVC soil, waste & rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion..Single socketed pipe |
| 31 | Removing SWR Pipe. Please Enable Macros to View BoQ information |