| Sl. No. | Item Description |
| 1 | M&L for brick work with sub class \"B\"brick straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 including all quoins, arches, pillars incl demolition of old existing brick/stonework etc complete all as specified and directed. |
| 2 | M&L for brick work (except bricks) straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 including all quoins, arches, pillarsincl demolition of old existing brick/Stone work etc complete all as specified and directed. (Old bricks obtained from demolition will be re-used) |
| 3 | M&L for brick work with sub class \"B\"brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wallincluding demolition of existing brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc.complete all as specified and directed. |
| 4 | M & L for 15 mm thick rendering in cement mortar 1:4 on brick work or concrete surface, finished surface even and fair mixed with water proofing compound as per manufacture instruction complete all as specified & directed.Note: Water proofing compound will be measured & paid separately under respective item of the schedule. |
| 5 | M & L for 15 mm thick renderingon brick or concrete surfacein cement mortar 1:6, surface finished even and fair complete all as specified and directed. |
| 6 | M & Lfor 15 mm thick rendering in cement mortar 1:4 on brick work or concrete surface, surface finished even and fair mixed with water proofing compound as per manufacture insturction incl taking down existing cement plaster complete all as specified & directed.Note: Water proofing compound will be measured & paid separately under respective item of the schedule. |
| 7 | M & L 15 mm thick rendering on brick/stone work or concrete surfacein cement mortar 1:6, surface finished even and fair incl taking down existing cement plaster complete all as specified and directed. |
| 8 | M & L 5 mm thick rendering on celing surface in cement mortar 1:3 surface finished even and smooth incl taking down existing plaster complete all as specified and directed. |
| 9 | Supply only liquid water proofing compound all as specified and directed. |
| 10 | M&L for preparation of wall and applying wall care putty1.50 mm thick to make the surface smooth complete all as specified and directed. |
| 11 | M&L for complete removal of existing treatment from old decorated surface of walls and applying two coats oil bound distemper any tint including preparation of surface complete all as specified and directed. |
| 12 | M&L for applying two coat of exterior weather proof 100% anti fungal acrylic smooth emulsion with silicon additives that offer anti alge high performance exterior wall finish with 6 years of performance warranty by manufacturer applied by using Airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacture with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper, should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower incl preparation of surfaces complete all as specified and directed. |
| 13 | M & L forapplying one coat of white wash on old decorated surface of ceiling including preparation of surfaces complete all as specified and directed. |
| 14 | M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 15 | M&L for preparation of newly plastered surface of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 16 | M&L for preparation of newly plastered surface of ceiling and applying two coat of white wash complete all as specified and directed. |
| 17 | M&L for complete removal/ demolition of existing treatment of sunken portion such as WC & bath and treated the sunken portion as per following specifications:-(i) Clean the complete surfaces, rubbish off the premises for sunken and washing down with water.(ii) Plaster for sunken portion in CM (1:3) mixed with WPC (Dr. Fixit or equivalent) as per manufacturer\"s instructions.(iii) Preparation of surfaces and applying one coat of polymeric primer @ 0.30 Kg/Sqm.(iv) Providing and applying APP based polymeric water proofing members 3 mm thick of weight not less than 3.00 Kg/ Sqm.(v) Applying one coat of bitumen 85/25 @ 1.2 Kg/Sqm.(vi) Providing PCC 1:5:10 mixed with brick bats 40 mm size for sunken portion.(vii) Providing 40mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) finish even and smooth. (viii) Poinding test carried out upto 1 to 7 days . |
| 18 | M&L for 25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in floor incl demolition old existing concrete complete all as specified and as directed. |
| 19 | M&L for non skidceramic coloured tiles 7 to 8 mm thick (Square/reangular) area of each tiles exceeding 0.06 sqm but n exc 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match and fixed with apoxyover and including 15 mm thick screed bed in cement mortar 1:6incl dismantling old existing tiles complete all as specified and directed. |
| 20 | M&L for non-skidceramic colour tiles 7 to 8 mm thick (Square/reangular) area of each tiles exceeding 0.11 sqm but n exc 0.18 sqm as in floor, set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 15 mm thick screed in cement mortar 1:6incl dismantling of old existing tiles complete all as specified and directed. |
| 21 | All as per item No 20 above but as in skirting fixed over and including 10 mm thick rendering in cement mortar 1:4, incl dismantling old existing tiles complete all as specified and directed. |
| 22 | M&L for glazed ceramic colour tiles size 350/250x7 mm/450x350x7 mmthick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match fixed over and including 10 mm thick rendering in cement mortar 1:4 incl dismantling old existing tiles complete all as specified and directed. |
| 23 | M&L for 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even andsmooth without using extra cementincl demolition old existing concrete complete all as specified and directed. |
| 24 | M&L for 40mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring, laid in alternate bays, surface finished even and smooth with using extra cement incl 4 mm thick glass stripps and demolition old existing floor complete all as specified and directed. |
| 25 | M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshade of granite incl dismantling old stone complete all as specified and directed. |
| 26 | M&L for grinding and polishing to edges and rounding of granite kota or marble slab and smooth finishing complete all as specified and directed. |
| 27 | M&L for Machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 15 mm thick screed bed in cement mortar 1:6 incl dismantling old existing old stone/floor complete all as specified and directed. |
| 28 | M&L for Machine cut kota stone as in skirting18-20thicklaid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing fixed over and including 10 mm thick rendering in cement mortar 1:4 incl dismantling old stone/floor complete all as specified and directed. |
| 29 | Taking down and re-fixing the existing shutter in same opening after & including necessary easing/repair etc. exc. 1 Sqm but n. exc. 2 Sqm each complete all as specified and directed. |
| 30 | Taking down and re-fixing the existing shutter in same opening after & including necessary easing/repair etc. n exc. 1 Sqmeach complete all as specified and directed. |
| 31 | Taking down shutter of any description, n. exc. 1 Sqm each and removing from site complete all as specified and directed. |
| 32 | Taking down shutter of any description, exc. 1 Sqm but n exc 2.0 Sqm each and removing from site complete all as specified and directed. |
| 33 | Taking down chowkhats or frames n. exc 1.5 sqm each without taking off shutter from the frame and removing from site complete all as specified and directed. |
| 34 | Taking down chowkhats or frames exc 1.5 sqm but n exc 4.0 sqm each without taking off shutter from the frame and removing from site complete all as specified and directed. |
| 35 | S&F Pressed steel frames of size 105x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and frame filled with and including PCC1:3:6 type C-0 with using 12.5 mm stone aggregatecomplete all as specified and directed. |
| 36 | S&F Pressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and frame filled with and including PCC1:3:6 type C-0 with using 12.5 mm stone aggregatecomplete all as specified and directed. |
| 37 | S & F 30mm thick second class hardwood (Golden Teak) glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge complete all as specified in SSR Pt I-2009 section 8 clause 8.24 (a) and as directed. |
| 38 | S&F 35mm thick 2nd class hard wood factory made plain framed panelled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply.The size of rail and stile as per IS:1003 (Part1),kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 39 | S&F 24 mm thick moulded WPC factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side plain with density not less than 600 Kg/cum.Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fireetardant and having screw holding capacity complete all as specified. |
| 40 | S&F factory made 100 % solid wood plastic composite (WPC) door frame 75x50mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termite proof, fire retardant and having good screw holding capacity all as per specification and drawing as directed. |
| 41 | S&F 18 mm thick WPC board one side prelaminated and other side plain white colour as in cup board shutters and frames, kitchen cabinet frontshutter, partion, shelf, & drawer, fixed with screws, solvent cement / adhesive incl dismantling of old existing boardcomplete all as specified and directed. |
| 42 | S&F 18 mm thick WPC board both side plain white colour as in cup board shutters and frames, kitchen cabinet frontshutter, partion, shelf, & drawer, fixed with screws, solvent cement / adhesive incl dismantling of old existing boardcomplete all as specified and directed. |
| 43 | S&F magnetic catcher and striking plate including letting in and fixedcomplete all as specified and directed. |
| 44 | S&F Continious (PIANO) hinges, mild steel, bright finish or electrogalvanised. 30 mm width of flaps (when open) complete allas specified as directed. |
| 45 | S & F stainless steel barrel tower bolts 150 mm long one piececomplete all as specified and directed. |
| 46 | S & F stainless steel barrel tower bolts 200 mm long one piececomplete all as specified and directed. |
| 47 | S & F stainless steel butt hinges, medium weight 100 mm long one piececomplete all as specified and directed. |
| 48 | S & F stainless steel handles 150 mm long one piece and fixed with screws/welded to frame complete all as specified and directed. |
| 49 | S & F stainless steel handles 125 mm long one piece and fixed with screws/welded to framecomplete all as specified and directed. |
| 50 | S & F 300 mm long stainless steel sliding door bolt (bolt not less than 12 mm dia) with hasp & staple and fixing clips of SS sheet, and SS fixing bolts complete all as specified and directed. |
| 51 | S&F floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed to floor of size 140 mmcomplete all as specified and directed. |
| 52 | S & F in 300 mm Mild Steel , ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 53 | S&F of powder coated ventilator fixed type and frame made with aluminium section with and including partly glass and partly stainless steel wire mesh and including aluminium grill of aperture not more than 40 sqcm, aluminium sections shall be of size as given below including taking down old window/ventilator etc complete all as specified and directed by Engineer in Charge. Frame : 44.5 x 44.5 x 1.98 mm thick including 5mm thick frosted glassfixed with rubber gasket with aluminium beading and stainless steel wire mesh of 0.63mm nominal dia wire and average width of aperture 1.40mm. Note :- (i) Making good of wall surface withmatching to existing surface as directed. (ii) Cost of glass, gauge and aluminium grill shall be included in the quoted rates. |
| 54 | S&F aluminum alloy powder coated standard hollow section as mentioned below for window frame (Bombay sliding) with two glazed shutter and one noswire gauged shutter sliding type with aluminum sections as per Series-A (15mm) 3 track of Jindal section numbers for sliding windows and glazed with tinted coloured glass 4mm thick, fixed with glazing clips, rubber beading / gasket anodised beading, screw and lock type handle of size 75mm, 2 Nos aluminum tower bolt 150mm long with stainless steel grill consisting of 12 mm square bar & 40 x 5 mm thick SS flat all around incl making good of existing surfaces with plaster and external (cement base paint)/ internal (OBD) finishes complete all as specified and directed. Shutter Top & bottom size : 37.50x15x1.60mmShutter inner lock size 37.50x15x1.60 mm Shutter side (Handle) size 37.50x15x1.36mmChowkhat bottom size : 50.30x26x1.20mmChowkhat top & sides size:50.30x26x1.00mm |
| 55 | S&F mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 including necessary welding, drilling holecomplete all as specified and directed. |
| 56 | M&L mild steelframed work as in doors or gates of angle or other section with gusset plates, rails, braces, ball bearing and other similar works etc, complete, drilled for fixing of steel sheeting or other covering.Doors, etc to be prepared for hanging or sliding incl dismantling old steel work any descriptioncomplete all as specified and directed. |
| 57 | S&F mild steel, plain, black sheet 1.0 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitered angles,incl dismantling old sheet any descriptionetc. as requiredcomplete all as specified and directed. |
| 58 | S&Fstainlesssteel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mmfixed with tinned tacks of stainless steel wirestaples complete all as specified and directed. |
| 59 | M & L for applying two coats of synthetic paint on newwooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and directed. |
| 60 | M & L for applying two coats of synthetic enamel paint onnew or previously untreated steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and directed. |
| 61 | S&F in repair SS grade 204 drapery rod 20mm diaincluding decorative brackets, decorative finals at both ends & curtain rings 8 Nos (Minimum) complete all as specified and directed. |
| 62 | Taking up or down 15mm bore PPR/ steel tubing and connection incl removal from site complete all as specified and directed. |
| 63 | Taking up or down 20mm bore PPR/ steel tubing and connection incl removal from site complete all as specified and directed. |
| 64 | S&F 15mm bore pipe medium grade galvanised iron with all fittings fixed to wall and ceiling or laid in floor complete all as specified and directed. |
| 65 | S&F 20 mm bore pipe medium grade galvanised iron with all fittings fixed to wall and ceiling or laid in floor complete all as specified and directed. |
| 66 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed. |
| 67 | S&F in repairs PVC connection 15 mm dia 450 mm long with brass fly nut at both ends complete all as specified and directed. |
| 68 | S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or includingcantilever brackets of suitable angle iron,CP brass waste coupling ,superior quality PVC waste pipe and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 69 | S & F in repair vitreous china squatting pan “ORISSA PATERN” of size 580mm x 440mm, white with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and directed. |
| 70 | S & F in repair 10 litre capacity PVC low level cistern ‘ white’ with inlet, float valve including brackets with 32 mm dia PVC pipe/bend 600 mm long complete all as specified and directed. |
| 71 | S & F in repair75 mm bore UPVC (SWR) pipe pressure 4kgf/cm2 single socketed in any length with rubber ring, fixed on wall / laid in trenches complete all as specified and directed. |
| 72 | S & F in repair 110 mm bore UPVC (SWR) pipe pressure 4kgf/cm2 single socketed in any length with rubber ring, fixed on wall/ laid in trenchescomplete all as specified and directed. |
| 73 | S & F as in repair 75 mm diaPVC (SWR) bends complete all as specified and directed. |
| 74 | S & F as in repair 110 mm diaPVC (SWR) bends complete all as specified and directed. |
| 75 | S & F in repair75 mm bore PVC (SWR) junction double, (double T) equal or unequal complete all as specified and directed. |
| 76 | S & F in repair110 mm bore PVC (SWR) junction double, (double T) equal or unequal complete all as specified and directed. |
| 77 | S & F in repairvitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and directed. |
| 78 | S&F in repair pillar taps, brass, with capston heads, fancytype chromium plated, screwed down high pressure with or without lettered \"Hot\" or \"cold\" with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed. |
| 79 | S&F in repair brass chromium platedovehead shower with shower arm complete all as specified and directed. |
| 80 | S&F in repair 15 mm bore Angle cock/stop valves, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 81 | S&F in repair 15mm bore bib taps long bodycast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 82 | S&F in repair 15mm bore Stop cock concealed typefancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 83 | S&F in repair 20mm dia bore gun-metal globe or gate valve ,with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 84 | S&F in repair CP Health Faucet with 1.20 mtr chromium plated metalic expandable tube & hook complete all as specified and directed. |
| 85 | S&F in repair CP grating 100mm to 125 dia round fix incl floor/ nahani trap with hole/without fixed with cement mortar, complete all as specified and directed. |
| 86 | S&F in repair looking mirror 600x450mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washer complete all as specified and directed. |
| 87 | S & F in repair 20 mm dia brass chromium plated towel rack of 3 sets type 60cm long between flanges including pair of fixing brackets complete all as specified and directed. |
| 88 | S&F in repair 32 mm dia waste fittings/ coupling brass, chromium plated for wash hand basin, basins, etc. with long screwed shanks and fly-nuts complete all as specified and directed. |
| 89 | S&F in repair 32 mm dia PVC waste pipe for WHBand sink 90 cm long with union, complete all as specified and directed. |
| 90 | S & F rotational moulded polyethylene water storage tanks 500 litres capacity,tripple layer, white colour,(cylindrical vertical with closed top) hoisted and fixed in position including dismantling of existing unserviceable tank and removing from site complete all as specified and directed. |
| 91 | S & Fin repairs ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed for 20 mm bore size (Minimum weight 210 gms) complete all as specified and directed. |
| 92 | S&F in repair of Aluminium body door cill at bottom part of door to stop entry of insect inside the room complete all as specified and as directed. |
| 93 | M & L for RCC(nominal mix), 1:2:4 type B-1(using 20 mm gradedstone aggregate) as in slabs supported on wall, beam and columns in floors ,roof slabs, shelves and cover slab Including necessary form work and demolition of existing old RCC complete all as specified and as directed. |
| 94 | S & F mild steel TMT bar 6-8mm dia cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 95 | M&L for 70 mm thick vibromatic reinforcedcement concrete precast 1:2:4 (using 20mm graded stone aggregate) with 1mm thick mild steel CR sheet around painted with 2 coats of bituminous paint ,as in drain cover slabsfinish fair even and smooth without using extra cement incl form work and 10 mm dia bar spacing of bar100mmc/cincluding , 100 mm long handle of 12mm dia round bar counter sunk by 25mm welded to reinforcement completeall as specified and directed. |
| 96 | M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in benching to drain, holdfast, padding to roof/chhajja, coping, bed block etc. and the like edge slightly rounded or chamfered including necessary use and waste of form work and demolition of existing old cement concrete (un-reinforced) not exc 15 cm thick inground floor and paving below or above ground level complete all as specified and directed. |
| 97 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 98 | Dismantling of framed or unframed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed. |
| 99 | Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coveringscomplete all as specified and directed. |
| 100 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 101 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and profile should match with galvalume sheet complete all as specified and as directed. |
| 102 | S&F Mild steelRoof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.Fe 410-W(Gde E-250) quality-A complete complete all as specified and directed. |
| 103 | Taking down carefully copper /aluminium point wiring (light, fan , socket or power ) any type including unscrewing from board,fitting and fixture such as switches, ceiling roses, holders, regulators sockets ,light fittings etc removing materials from site and making good disturbed with the existingsurfaces complete all as directed. |
| 104 | M&L for point wiring with 1.5 sqmm PVC insulated, unsheathed, stranded copper conductor (FRLSH) cable single core 1100 Volt grade in and including rigid PVC conduit medium grade 20mm dia or more ISI Marked concealed / Surface conduit as per existing and conduit accessories and cutting chases of suitable girth where required on brick/concrete surface &making gooddisturbed surface,provision of CI/Pressed steel terminal switch box with plastic laminatedsheet 3 mm thick fixed with brass screw and washers along with 1.5 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLS H) as earth wire connected with main common earth dolly complete all as specified and directed for the following :- |
| 105 | One light/fan/bell/exhaust fan point controlled by one, one-way switch 5/6 Amp. |
| 106 | One 3pin 5 Amps socket out let on same board controlled by one, one-way switch. |
| 107 | One 3pin 5 Amps socket out let onindependent board controlled by one, one-way switch. |
| 108 | All as per item No.104 here in before but point wiring with 2.5 sqmm multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm PVC insulated multi strand copper conductor cable as continous earth wire. Note: ( In One ckt of onepoint only) |
| 109 | M&Lfor Point wiring with 1.5 Sqmm (Nominal area) FRLSH PVC insulated and unsheathed single core cable 1100 volts grade with stranded copper conductor drawnthrough existing concealedconduit any type and size,complete including pressed iron/ steel sunction box of thickness 1.2 mm for mounting of switches, sockets fan regulators etc with 3 mm thick plastic laminated sheet as top cover , and 1.5 sqmm ( nominal ) single core FRLSH, PVC insulated 1100 volts, grade multi stranded unsheathed FRLSH copper conductor cable green colour as earth wire upto common earth and connected to earth dolly including cutting chases for sunken boxescomplete all as specified & directed for the following:- |
| 110 | One light/fan/bell/exhaust fan point controlled by one, 01-wayswitch 5/6 Amp. |
| 111 | One 3pin 5 Amps socket out let on same board controlled by one, one-way switch. |
| 112 | One 3pin 5 Amps socket out let onindependent board controlled by one, one-way switch. |
| 113 | All as per item No.106 here in before but point wiring with 2.5 sqmm multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm PVC insulated multi strand copper conductor cable as continous earth wire. Note: ( In One ckt of onepoint only) |
| 114 | S&F switch Piano flushtype single pole one way230 Volts 6 Amps complete all as specified and directed. |
| 115 | S&F switch Piano flushtype single pole one way230 Volts 15 Amps complete all as specified and directed. |
| 116 | S&F Socket outlet 3 pin , 230 Volts 5/6 Amps multipurpose 5 pin complete all as specified and directed. |
| 117 | S&F Socket outlet multipurpose having provision for 3 pin, 230 Volts 15/16 Amp and 3 pin, 5/6 Amp, piano flush type complete all as specified and directed. |
| 118 | S&F bell pushpiano flush type single pole one way 6 Amps complete all as specified and directed. |
| 119 | S&F bell ding dong elelctric 230V ACsingle pole complete all as specified and directed. |
| 120 | S&F ceiling rose 3 terminal / PVC/ polycarbonate, isolated body ISI marked all as specified and directed. |
| 121 | S&F batton holder ISI Marked mounted on wall including 09 Watt LED Bulbcomplete all as specified and directed. |
| 122 | S&F step type electronic fan regulator flush type120/280 V complete all as specified and directed. |
| 123 | S&F in replacement energy efficient LED tube light fitting20 watts, 230 volts with efficiency of not less than 100 lumensper watt, PC extruded body with PC diffuser including connecting up with three core flexible copper conductor cable of suitable size from ceiling completeall as specified and directed. |
| 124 | S&F in replacement mirror light decorative compact luminaries with decorative ends caps incl9/10 Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 125 | S& F oval shape Bulk headEdge-lit LED fitting comprising with high brightness LED 10 watt, IP-67 protection complete all as specified and directed. |
| 126 | S& F GlazeWall Light including 7/9 watt LED ( B22) type complete all as specified and directed. |
| 127 | S&F in replacement LED building securitylight fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with IP 65/66 protection complete including bracket made out of 32 mm bore medium grade GI pipe made to shape with bolts, buts & washers of min 1.2 Mtr incl grouting of nuts or fasteners clamps and conductor to fitting with 3 core 1.5 sqmm PVC insulated cable complete all as specified and directed. |
| 128 | S&F sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium gradesurface on wall along with 4 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected withmain earth dolly including cutting chasing and making good disturbed portionand taking down old unserviceable wiring complete all as specified and directed. Note: 03 runs of copper cable and one run of conduit will be measured as 01 RM unit length. |
| 129 | S&F sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 8 way with 200 Amps rated busbar including taking down old unserviceable DBs any type complete all as specified and directed. |
| 130 | S&F in repair MCB SP 6 to 32 Amp \"C\" series 10 KA repturingcapacity complete all as specified and directed. |
| 131 | S&F in repair MCB SPN40 Amp 240 V AC 10 KA repturingcapacity complete all as specified and directed. |
| 132 | S&F in replacement for distribution Box MCB Procted socket with sheet steel enclosure 20 A MCB DBOXX Combo DP including PLUG TOP complete all as specified and directed. |
| 133 | S&F electric water heater storage type, ABS Body with Glass lined tankand heating element upto 2KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve thermostate NRV connection piece complete all as specified and directed. |
| 134 | S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter,voltage 230V,50 Hz,RPM 1200, Copper winding of sweep 250 mm sweep complete including making of holes where required at site with all fittings complete all as specified and directed. |
| 135 | S&F exhaust fan steel body AC Single phase,230 voltof size 300 mm sweepwith blades, and frame and louverscomplete with all fittings, including making of holes where required at site complete allas specifiedand directed. |
| 136 | Taking down ceiling fan from existing building and kept in safe custody and again refixing the same after greasing / oiling the same ceiling fan including provision of cable flexible 3 core of suitable size wire from ceiling rose to fan complete all as specified and directed. |
| 137 | Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 35 sqmm 3.5 core, passing through pipe, laid in trenches, fixed on wall,LT panel board,with required aluminium cable lugs, lugs should properly crimmping with crimpping tools, heat shrink joints, Colour code heat shrink sleeves at both cable ends, cable gland for cable safety when passing through panel holes, including laying cable route indicators of suitable size RCC or steel type as per site requirement complete all as specified and directed. |
| 138 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unsv LT cable for laying of cable and getting out complete all as specified and directed. |
| 139 | M&L sand cushioning and covering of under ground cable using crushed metal sand in trenches for cable protection complete all as specified and directed. (Punned thickness will be measured) |
| 140 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in hard /loose soil complete all as specified and directed. |
| 141 | Removing excavated material (soil) to a distance n. exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above the starting point complete all as specified and directed. |
| 142 | M&L for brick well burnt Class ‘B’ as cover to underground cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over under ground cable for cable protection in trenches complete all as specified and directed. |
| 143 | M&L for GI Tubing light grade 40 mm dia with all fitting/acessories for cable protection as per site requirement complete all as specifid and as directed. |
| 144 | Supply, installing, testing and commissioning factory made and tested LT Panel Indoor type Wall mounted, of size : 900 X 700 X 250 mm suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 200 Amps rating installed on DMC insulators with bus bar chamber. front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The scope of work also comprising of the following:- |
| 145 | BUS BAR CHAMBER:- (a) 200 Amps 3 Strips and Neutral Strip 100 Amps, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.(i) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).INCOMING SUPPLY:- (i) MCCB 125 Amps 25 KA , 4 Pole with Adjustable thermal & Fixed magnetic setting release 415 Volts, 50Hz =01 NosOUTGOING SUPPLY:- (i) MCB SPN 40 Amps, 230 volts, 50Hz, rupturing capacity 10 KA = 5 Nos(ii) Space for Fixing of1 Phase,2 Wire, Pre-paidEnergy Meters- 04 Nos(iii) DMC Connector 2 way 100 A for outgoing submain supply - 5 Nos.Panel wiring for control circuit with copper flexible 1.5 Sqmm& powerwiring minimum 4 Sqmm flexible. |
| 146 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25 mtr depth below ground level at any type of strata) with top edge of the earth plate not less than 1.5mtr below normal ground level connected by 4 mm dia GI wire as earth lead connected by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, pit cover of size 320x320x80mm size with RCC (1:2:4) Type B-1, using 20mm graded stone aggregate reinforced with XPM, filled around with charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail