| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.a) Group C |
| 2 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 3 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required a)2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 4 | c)4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 5 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.a)5/6 amps switch |
| 6 | b)3 pin 5/6 A socket outlet |
| 7 | c) 15/16 A switch |
| 8 | d) 6 pin 15/16 A socket outlet |
| 9 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.a) 200 mm X 150 mm X 60 mm deep |
| 10 | b)150 mm X 75 mm X 60 mm deep |
| 11 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 12 | Supplying of pre-wired for LED, power saving Decorative box type LED tube Batten fittings, 4\" powder coatedforsimilar to BAJAJ IVORA® LED BATTEN and 4\" x 25 wattsHigh efficiency, power saving LED Batten Cat No. 830258 Bajaj IVORA® LED Batten 25W CDLor its equivalent etc., as required. |
| 13 | Supplying ofEnergy Saving BLDC, 5 star rated,Ceiling fan 1200 mm sweep (ISI Marked) (White), with all accessories and Step type electronic Fan regulator Similar to HAVELLS Efficiencia DX BLDC, Cat No. FHCEO5SWHT48 with out remote(ISI Marked and BEE 5 Star Rated) power consumption with switch control with 5 years warranty or its equivalent or its equivalent |
| 14 | Installation, Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LEDlamps per fitting, complete with all accessories including connections etc. as required. |
| 15 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 16 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 17 | Supplying of LED Retrofit Bulbs 10 Watts B22 (Cool Day Light). Similar to HAVELLS LED ADORE 10 W B22 CDL 3 STAR LAMP or its equivalent etc., as required. |
| 18 | Supplying and fixing of Street Light luminaries 25 Wattage, with pressure die cast aluminium housing heat resistant glass i/c Clamping arrangement with GI Pipe etc., as required. (Equivalent to BAJAJ EDGE NXTCat. No.ENXT P 25L WH PO PC SD) or its equivalent etc., as required. |
| 19 | Supplying of Pre-Wired Eco Friendly and energy saving LED Recess Mounted2\" x 2\" Square Backlit Panel Type Fittings, Powder Coated White CRCA, full glow LED Panel Light 36 Watt 2\" x 2\" with 36 Watt Driver. Similar to Havells Endura Slim Pro Plus 2X2 Series, Cat No. ENDURASLIMPROPLUS2X2PLR28 / 36WLED857MOD and Driver Cat No. LEDDRIVER36V36WSor its equivalent etc as required. |
| 20 | Supplying of Exhaust fan of size 200 mm sweep with protective bird guard (similar to BAJAJ MAXIMA DXL-G02, WhiteExhaust Fan or its equivalent etc as required. |
| 21 | Installation of exhaust fan in the existing opening, includingmaking good the damage, connection, testing, commissioningetc. as required. a)Upto 450 mm Sweep |
| 22 | Providing earthing with safe earthing electrode of galvanization 80 to 100 microns, length 2 mtr, outer dia 50 mm, inner dia 19 mm and inner space be filled with crystalline conductive mixture including filling -up with electrolite (Back fill compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc. as required. (Ashlok)(Proof/ Test Certificate should be enclosed) |
| 23 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 24 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 25 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB/ Isolator)a) 4 way (4 + 12), Double Door |
| 26 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a)Single Pole |
| 27 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) 63 A |
| 28 | Supply, installation, testing and commissioning of following capacity and rating wall mounted split Air conditioner, inverter type fitted with rotary compressor operating on 230v ± 10%, 50Hz single phase AC supply with evaporator and condensing unit made of copper tubes, cordless remote control, copper piping for both suction and discharge of 3 meters length with protection covering for piping , power and control cabling as per site requirement comprising of following etc. complete as per requirement including first charge of refrigerant. a) Insulated copper pipe lines liquid and suction lines as per manufacturer recommendation.b) Flexible copper cable between indoor & outdoor unit of suitable size as per manufacturer recommendation. c) Drain pipe.d) 2.0 Ton TR Capacity, 5 Star Rating Inverter Air Conditioner |
| 29 | Supplying and fixing of 5 KVA Voltage stabilizer suitable for 1.5 ton Air Conditioner as required. Make: V-guard Model VS 500 (Voltage Range 170V-280 V, 12 amps.) or equivalent. |
| 30 | Providing & Fixing of Pre-fabricated stand for keeping outdoor units of 1.5/2 Ton capacity split type AC as required. |
| 31 | Supplying and fixing 20 A, 240 V, SPN Industrial type socketoutlet, with 2 pole and earth, metal enclosed plug topalong with 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioningetc. as required. |