| 1 | Dismantling Mangalore patteren or similar type tiles in roofing including portions bedded in cement mortar of any height including scafolding complete all as specified and directed. |
| 2 | M&L for roof tiles, Mangalore Pattern,interlocking at side joints, laid dry including scafoldings of any height complete all as specified and directed. |
| 3 | M&L for ridge or hip tiles to suit Mangalore pattern of roofing tiles,bedded and jointed in cement mortar 1:6 complete all as specified and directed. |
| 4 | S&F in repairs to replace old or decayed boarding in patches including cutting out old,piecing, heading joints etc 20 mm thick second class hardwood clean sawn boarding fixed with nails with butt joints in any situation including scafoldings of any height complete all as specified and directed. |
| 5 | M&L in repairs old or decayed boarding in patches including cutting out old, piecing, heading joints etc second class softwood wheather boarding, clean sawn, plain, 20 mm thick or feather edged 15 mm to 20 mm thick and fixed with 30 mm laps including scafoldings of any hieght complete all as specified and directed. |
| 6 | Dismantling of roof battens for tiles, shingles etc, of any size including tilting fillets spaced n exc 15 cm of any description in any position complete all as specified and directed. |
| 7 | M&L second class hardwood clean sawn battens at 30cm centres sectional area exc 15 & n.exc 25 Sqcm including scafoldings of any height complete all as specified and directed. |
| 8 | Dismantling of framed work timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed. |
| 9 | M&L second class hard wood clean sawn in scantlings timber framed and fixed in any position and description including scafoldings of any height complete all as specified and directed. |
| 10 | M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (ordinary paint tint) (each coat) over a coat of pink primer including scafoldings of any height complete all as specified and directed. |
| 11 | M&L for preparation of old painted surface of wood and wood based surfaces by knotting, stopping etc of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 12 | M&L for preparing surfaces of battens, any size and spacing, and treated all over with creosote (measured overall on one side only, spaces not deducted) including scafoldings of any height complete all as specified and directed. |
| 13 | Taking down cement plaster ofany description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 14 | M&L for providing 15 mm thick rendering with cement mortar 1:6 finished even and smooth (without using extracement) complete all as specified and directed. |
| 15 | M&L for providing 15 mm thick rendering with cement mortar 1:4 finished even and smooth (without using extracement) complete all as specified and directed. |
| 16 | M&L for providing rendering 10 mm thick in CM (1:3) as in ceiling concrete surface finish even and smooth of any description etc complete all as specified and directed. |
| 17 | M&L for preparation of newly plastered surfaces of walls and applying 1.00mm thick wall care putty on wall surfaces and a coat of wall primer and two coats of oil bound distemper (White or tinted) complete all as specified and directed. |
| 18 | Supply only liquid water proofing compound. |
| 19 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 20 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and as directed |
| 21 | M&L for complete removal of existing treatment andapplying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces all as specified and as directed |
| 22 | Demolation of cement Concrete of any description and in any position not otherwise specifically providedcomplete all as specified and directed |
| 23 | M&L for Providing, cement concrete type B-1, 1:2:4 ( 20 mm graded aggregate)in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed |
| 24 | M&L 25mm thick PCC type B-0, 1:2:4(12.5mm graded stone aggregates) as in floor/ roof surface complete all as specified and directed. |
| 25 | M&L rendering 15mm thick in CM 1:4 mixed with WPC on roof surfaces finishedeven & smooth without using extra cement complete all as specified and directed.Note : WPC shall be measured & paid separately. |
| 26 | M&L for roof treatment with polymeric membrane (APP based) with non woven polyester mat as reinforcement with following:-(a) M&L for surface preparation by removal/ taking down of existing treatment of tar felt/ tiling/loose particle to ensure or clean smooth and dry surface and preparing the surface.(b) M&L for providing & laying a coat of cold applied bitumen 85/25 based primer on entire surface @ 0.30 Ltr/Sqm on dry and clean surface.(c)M&L for providing & laying APP based polymeric membrane of 3 mm thickness of weight of 3.0 Kg/Sqm with non woven polyster fiber as reinforcement on primed surface by torch application with side over laps & joints over laps etc as per manufacturers instruction.(d) M&L for finishing of top surface by two coat of aluminium paint over a coat of blown bitumen 85/25 grade @ 1.2 Kg/Sqm grouted all as specified and as per manufacturers instruction.(e) M&L for providing test with filling of water over roof slab continuously for 48 hours all as specified and directed. |
| 27 | M&L for Cement concrete tiles 25cm x 25cm x 20mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished complete all as specified and directed |
| 28 | Taking down chowkhat or frames not exc. 1.5 Sqmeachwith shutters (without taking off shutters from frames)complete all as specified and directed. |
| 29 | S&F anodised aluminium section for doors windows, ventilator door partition including fabrication of frame shutters and fixed with necessary lugs, cleats rollers, handles, locking arrangement etc including all necessary accessories such as glazing clips, provn of AC opening and rubber beading for fixing glass beading for fixing glass paanes in frame complete all as specified by Engr-in- charge.Note- (i)Glass panes will be measured and paid separetly. (ii) The quoted rate shall be inclusive of cost of rubber beading and glazing clip hinges, handle however it will be not be weighteed and not paid separately. (iii)All other minor details including cost of locking arrangement shall be included in the quoted rate. |
| 30 | Supply only for 5 mm thicksheet glass, ordinary quality and glazing oil putty or with wooden beading in squares n exc 0.50 sqm in each pane complete all as specified and directed. |
| 31 | S&F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 32 | S&F Aluminum tubular hallow section 25x25mm not exceeding 900 mm c/c on exceeding columns/beam/slab to holdcladding etc and fixing HPL sheet panel cladding plain metallic of approved colour/ shade to beam/ column/ slab in circular/ rectangular shape including cutting, notching, bending to shape as required jointing with silicon gel of approved colour complete all as specified and directed. |
| 33 | Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the primises complete all as specified and directed |
| 34 | M&L Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes like tiles etc complete all as specified and directed. |
| 35 | M&L rendering 10 mm thick plaster on fair faces of brick work in CM (1:4) complete all as specified and directed. |
| 36 | M&L Glazed ceramic tiles in vertical surface 600x1200x 10 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shades of tiles, complete all as specified and directed. |
| 37 | M&L for Virified Ceramic tiles8 to10 mm thick (square/ rectangular) polished area of each tiles n.exceeding 1sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 15 mm thick screed bed in CM 1:6 complete all as specfied and as directed. |
| 38 | M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc, of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed |
| 39 | Demolition of brick work or stone /boulder masonry built in cement mortar, including all quoins, arches, pillars, etc complete all as specified and directed |
| 40 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exc 6 m mean radius and built in CM (1:6) complete all as specified and directed |
| 41 | S&F Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheetinclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed |
| 42 | M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed |
| 43 | M&L for providingbasket cable tray fo width 600mm height not exc 200 mm and thickness not less than 5 mm made ofstainless steel complete all as specified and directed |
| 44 | Dismantling of water tanks of any capaciaty and any typeand removing to store complete all as specified and directed. |
| 45 | M&L 500 ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) incl 20mm PTMT ball valve and tank cover (Ball valve make:- Prayag) and tank cover of hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed |
| 46 | Dismantling of ceiling board (Plup insulation or insulation etc) or insulation board any thickness including cover fillet and grid frame work all as directed. |
| 47 | Providing & fixing false ceiling atall heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of ted perforated 12mm Size 595x595 mm of approved texture,design and patterns having moisture content less than 2%, humidity resistance of99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 4 76 (Part 4) - 1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15 x 32 mm of length 3000mm, cross-T of size 15x 32mm oflength 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm (having filled with black silicaon), suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in Charge. |
| 48 | M&L MS Roof trusses (framed), trussed, purlins, crane gantries, rails, bolts and fastenings and heavy bracket framing, casing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc and welding work complete all as specified and directed. |
| 49 | M&L for non skid joint free heavy duty paver colour tiles 10 mm thick in floorn.exc 36 sqm set and jointed in neatr cement slurry and pointed in white or coloured cement to match over and incl 15 mm thick screed bed in CM 1:4 complete all as specified and as directd. |
| 50 | M&L for complete removal of existing treatment on walls incl washing, rubbing down and stopping and applying two coats of oil bound distemper over 1 mm thick wall care putty(White or tinted) complete all as specified and directed. |
| 51 | S&F in repairs PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall (110 mm bore) including taking down complete all as specified and directed. |
| 52 | M&L for granite 14-16 mm thick (table rubbed and polished) in cooking platforms, stair case, riser and threadand like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl moulding of front side if requiredcomplete all as specified and directed. |
| 53 | Removing the old paints by rubbing, grinding and scrubbing off completely stripped to bare wood or wood based surfaces exposing original wooden texture (with Paint & Varnish remover if required) complete all as specified and directed. |
| 54 | S&F of 12 mm thick plain toughened glass in doors/ windows framing doors handle, suitable hinges, rubber beading, floor spiring and all necessary fittings completeall as specified and directed. |
| 55 | S&F 15 micron coloured aluminium anodised grill design No DG-117,10 mm thick including F Sections complete all as specified and directed. |
| 56 | S&F 110mm dia PVC (SWR) bendsany radiusincluding GI clamps of approved shape and size approved by GE at any height, any location, any floor including necessary scaffoldingcomplete all as specified and directed. |
| 57 | S&F for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 58 | S&F for 12 mm thick plywood, grade BWP type BB fixed with brass screws and cups to timber frame work complete all as specified and directed. |
| 59 | S&F for 2 mm thick veneered designer natural wood grain sheet fixed with adhesive as per manufactrue instruction to plywood work complete all as specified and directed. |
| 60 | S&F for Plain fillets of first class hard wood, square or rectangular in section, clean sawn, wrought, secured with nails or brads; sectional area exceeding 6 Sqcm but not exceeding 13 Sqcm complete all as specified and directed. |
| 61 | S&F for decorative fillets of Ist class hard wood, secured with nails or brads; sectional area exceeding 3 Sqcm but not exceeding 6 Sqcm complete all as specified and directed. |
| 62 | S&F Sun control film, 50 micron non reflective type, sticked to glass as per manufacturers instructions complete all as specified and directed. |
| 63 | M&L for Marble Makrana white 18 to20mm thick machine cut, bedded jointed and pointed with greycement slurry including cutting and polishing types complete all as specified and directed. |
| 64 | Providing and injecting ATT for chemical emulsion usingchlorpyriphos 20 percent EC with 1 percent concentartionfor post constructional Anti-termite treatment along external wall below concrete or masonary apron using chemical emulsion at the rate of 2.25 literes per linear metre including drilling and plugging holes etc in apron complete all as specified and directed. |
| 65 | Providing and injecting ATT for chemical emulsion usingchlorpyriphos 20 percent EC with 1 percent concentartionfor post constructional Anti-termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) at the rate of 0.50 litre per hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed. |
| 66 | S&F in repairs 3 fold vanishing blinds having cylindrical top of 2 mm thickness, aluminium pelmet, Zebra manual operation set, aluminium bottom powder coated with end caps & clamps of any size & of any colour complete all as specified and directed. |
| 67 | Dismantling and taking down carefully U/S copper/aluminium point wiring (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified & directed. |
| 68 | Dismantling and taking down carefully sub-main wiring/ service wire of any size including wooden batten etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and directed. |
| 69 | Dismantling and taking down carefully existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and directed. |
| 70 | M&L for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694/1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLS-H) with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLS-H) PVC insulated unsheathed, drawn in and including concealed rigid PVC conduit (ISI marked), duly concealed to wall/floor or above false ceiling with fittings (ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified) including modular metal flush box made of GI sheet and modular white frame plate with cover, including chase cutting complete all as specified and directed for the following:- |
| 71 | One light/fan/bell/exhaust fan point controlled by one, one-way switch 5/6 Amp complete all specified and directed. |
| 72 | One 6A socket point controlled by one switch on independent board |
| 73 | One 6A socket point controlled by one switch on same board |
| 74 | -Ditto- all as per item No. 70 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires. |
| 75 | S&F switch piano flush type whitefinish 5/6Amps, single pole one way, 240 volts, 50 hz complete all as specified & directed. |
| 76 | S&F switch Socket 6 Amps, 2-in-1 flush type universal on, 240 volts, 50 hz complete all as specified & directed. |
| 77 | S&F switch piano flush type 16 Amp, one way, 240V, 50 Hz, Complete all as specified and directed |
| 78 | S&F switch socket 16 Amp & 6 Amp, 2-in1flush type 16 Amp, one way, 240V, 50 Hz, Complete all as specified and directed |
| 79 | S&F in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor twin core, 16 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections including connecting on LT OH line/energy meter/DB etc complete all as specified and directed. |
| 80 | M&L for Ceiling rose in poly carbonate 3 terminal brass flush type 6 Amps, 250 volts ACISI marked, fixing on 3 mm thick sunmica hylum plastic laminated round sheet 75mm dia complete all as specified and directed. |
| 81 | Dismantling the old serviceable light fitting from site and refixing the same light fitting after repairs works with the help of two core 0.5 sqmm copper wire to ceiling rose complete all as specified and directed. |
| 82 | S&F LED tube light batten 20 watts 4 fts extruded PVC housing, translucent diffuser with LED light source, minimum 2000 lumen, natural white, surge protection range-2KV, voltage protection range 120-280 VAC with intergrated driver and surge protection complete all as specified and directed. |
| 83 | S&F in replacement of surface/recessed mounted LED panel light 2\"x2\" size, 36 or more than 36 watts, full white/warm white as per site requirement with electronic driver in CRCA sheet steel body with polycarbonate diffuser suitable for POP /Amstrong/ grid false ceiling complete with all fixing accessories including making electrical connection with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified. |
| 84 | S&F new sub main wiring with two runs of 6.0 Sqmm 1100 Volt grade single core PVC insulated and unsheathed (FRLS-H) LT cable having multi stranded copper conductor, drawn through and including PVC non metallic conduit of 25mm/appropriate dia with all accessories and one run of 4.0 Sqmm 1100 Volt grade single core PVC insulated and unsheathed (FRLS-H) LT cable having multi stranded copper conductor for earthing complete all as specified and directed. |
| 85 | S&F new sub main wiring with two runs of 4.0 Sqmm 1100 Volt grade single core PVC insulated and unsheathed (FRLS-H) LT cable having multi stranded copper conductor, drawn through and including PVC non metallic conduit of 20mm / appropriate dia with all accessories and one run of 2.5 Sqmm 1100 Volt grade single core PVC insulated and unsheathed (FRLS-H) LT cable having multi stranded copper conductor for earthing complete all as specified and directed. |
| 86 | Taking down old serviceable ceiling fan from the site and hanging the same ceiling fan after repair works complete with three blades, down rod upto to the ceiling rose as per site requirement, alongwith accessories complete all as specified and directed. |
| 87 | Taking down old unserviceable ceiling fan & S&F BLDC Ceiling fan complete with three blades, down rod as per site requirement, alongwith accessories, 230 V, 1200mm sweep, with remote BEE 5 star white/warm white complete all as specified and directed.Note: Old Ceiling fan to be deposited in MES store Yard |
| 88 | S&F TP&N vertical load line (VTPN) 4 way 415 Volts 50 Hz indoor type double door sheet metal enclosure IP-43 DBs with copper bus bar not less than 160 Amp for each phase with two neutral bar & two earthbar and cable lies for cable management for provision of MCCB 100 Amps ICs=100% ICu, 16 KA four pole as incomer including connecting terminal strip complete and SP MCBs as outgoing complete pre-wired with suitable size copper conductor complete all as speciifed and directed. |
| 89 | S&F sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 8 way with suitable rated busbar all as specified and directed. |
| 90 | S&F MCB, SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, \"C\" series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 91 | S&F MCB, SPN, AC, 240 volts of 40 Amps capacity 10KA, \"C\" series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 92 | S&F MCCB 100 Amp, 16 KA, TPN,\"C\" curve, 415 V, 50 Hz including taking down existing unserviceable MCCB of any description complete all as specified and directed.Note: MCCB should be of same make as of VTPN 4 way |
| 93 | Dismantling and disconnecting the all existing cables from the existing location and then put the existing cables into inward bend type cable tray alongwith connecting the same existing cable with theiir existing DBs and VTPNs with suitable lugs and thimbles as per size of cable complete all as specified and directed. |
| 94 | S&F in replacement of modular MCB protected Top plug and socket board in sheet steel enclosure with 25 Amp rated mini MCB and 25 Amp rated 3 pin plug, 240 V, 50 Hz completed including cutting the wall surface for flush mounting of scoket borad and making good with cement plaster. Putty and paint to match with the exisiting surface complete all as specified and directed. |
| 95 | M&L in replacement for feeder pillar bus bar box of size 600x450x550 mm outdoor type, double door, both side, openable with loacking arrangement, powder coated, 3.00 mm thick CRCA sheet water proof hinged, having 4 nos aluminium bus bar of capacity 250 Amp duty colour coated mounted on porcelian insulator, holes on bottom for cable entry and exit with suitable size cable gland and mild steel stand for mounting of planel borad made of angle iron of size 50x50x6 mm, 1.0 meter high (450 mm below ground level and 600 mm above ground level) alongwith necessary cement concrete for grounting of planel stand, foundation and connection the panel with earthing complete all as specified and directed |
| 96 | S&F the perforated cable tray of width 300 mm, Height 60 mm and thickness 3 mm, made up of SS on the wall for rearranging the existing cables with suitable joint connector, corner connector including nut, bolts, screws, washers etc complete all as specified and directed. |
| 97 | S&F in replacement of electronic socket type fan regulator rotary type in 5 steps, 240V, 50Hz complete all as specified and directed. |
| 98 | Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron, UL listed, CPRI Tested at 25 KA fault current for one second and is provided with universal clamp made of SS earth enhancing compound shall be of 50kg/pit (resistivity is less than 0.12 Ohm meter) tested as per IEC 62561-7. The above arrangements shall be provided with heavy duty earth poly plastic pit cover of 6000 kg load bearing capacity (Size:270 x 240 x 200mm) and FRLS insulated copper conductor of size 6 sqmm, single core cable drawn through and including light grade GI pipe of size 15 mm upto 7 mtr incl cutting and chases on wall and floor and aking good using PCC complete all as specified and directed.Note :- On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (b) Rate quoted by contractor is inclusive of excation work for earthing and refilling the excavated soil around earth pit. |