Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holesand making good reqd shape for hold fast block for new frame complete all as specified & directed by Engineer-in-charge. |
| 2 | S & F Spray duco painted Pressed steel frames made of MS sheet of 1.20mm thickness of size 125 x 60 mm for doors with single or double rebate including necessary fixing lugs, hinges, lock strike plate, hold fasts, PCC 1:3:6 type C-0 in fillinng inside frame & hold fasts etc complete all as specified & directed by Engineer-in-charge.Note :- Distrubed protion of existing floor/ wall/ tile/ plaster etc during fixing of chowkhats shall be repaired to match with exisitng finish.Cost of the same will be included in this items. |
| 3 | Taking down shutters of any description exc 1sqm but not exc 2.00 sqm each complete all as specified & directed by Engineer-in-charge. |
| 4 | S & F 35mm thick glazed and skelton shutters of 2nd class hard wood (factory made) open rebated and divided to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR-91 Pt-I section 8 clause 8.20 (a) kiln seasoned and chemically pressure treated all as specifeid including stainless steel 304 grade wire cloth ( 0.36mm nominal dia of wire and average width of aperture 1.40 mm ) complete all as specified and directed by Engineer-in-charge and including supply and fixing following items :-(a) Stainless Steel (304 Grade) Finished Butt Hinges 125mm -3 nos per leaf(b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos per leaf(d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16x3000mm- 1 nos per leaf(e) Stainless Steel (304 Grade) Finished Floor Door Stooper- 1 nos per leaf |
| 5 | S & F Factory made ISI marked flush door shutters 35mm thick, BWP conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 2nd class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters complete all as specified and directed by Engineer-in-charge and including supply and fixing following items :-(a) Stainless Steel (304 Grade) Finished Butt Hinges 125mm -4 Nos per leaf(b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf(d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16 x 300mm- 1 No per leaf(e) Stainless Steel (304 Grade) Finished Floor Door Stooper- 1 No per leaf |
| 6 | M & L for preparation of new wooden surfaces of any description exc 10 cm width or girth and applyingtwo coats of synthetic enamel paint, first quality, over a coat of pink primer on wooden surface complete all as specified & directed by Engineer-in-charge. |
| 7 | Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqmincl cutting holesand making good reqd shape for hold fast block for new frame complete all as specified & directed by Engineer-in-charge. |
| 8 | S & F solid PVC door frames of size 50x47mm made out of 5mm plain colour PVC sheet supplying and fixing in opening as per specification and drawing shown in SSR complete all as specified & directed by Engineer-in-charge. |
| 9 | S & FFactory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification incl the fwg S & F :-(a) Stainless Steel (304 Grade) Finished Butt Hinges 125mm -3 Nos per leaf(b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf |
| 10 | S & F in repair 300mm, mild steel, ordinary rat tailrod pattern springs including roller and roller plate, bearing ISI markcomplete including necessary welding work complete all as specified & directed by Engineer-in-charge. |
| 11 | S&F in repairs Stainlesssteel tubing of 25 mm dia chromium plated min. 1.0 mm wall thickness as in curtain rod complete incl S&F 02 Nos stainless steel brackets/finials fancy type, stops fixed with ss screws etc acomplete all as specified & directed by Engineer-in-charge.Note : For the purpose of mesurement and payment running length of curtain rod only shall be considered. |
| 12 | S & F in repair 6mm thick of size 600x450mm looking mirror fixed to wall with stainless steel plugs/ connecter/ spacers/ screws etc. chrome finish without any beading, including ends/edges of the mirror to be tapered etched smooth finish etc.complete fixed in position complete all as specified & directed by Engineer-in-charge. |
| 13 | S & F for Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified & directed by Engineer-in-charge. |
| 14 | S&F European type water closet including CI P/S trap as directed including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc.,with flush pipe PVC 32mm dia and incl. plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc; and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and including supply and fix of PVC long arm P/S trap so that joint is avoided inside the building as well as in wall and outlet straight away come out of wall in all floors G.F.and taking down existing of any description/size complete all as specified & directed by Engineer-in-charge. |
| 15 | S&F Flushing cistern of PVC 10 ltr. cap. with dual flushing system, valveless syphonic action type, , low level, white/ivory/off white with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete all as specified & directed by Engineer-in-charge. |
| 16 | S & F in repairs 150 mm over all length floor door stopper, bearing ISI mark, of aluminium alloy body and tongue, anodised with hard drawn steel spring, complete all as specified & directed by Engineer-in-charge. |
| 17 | S & F in repair of 3mm thick Fibre-reinforced plastic sheet of transparent colour of any of size including necessary screw and other accessories all as specified and directed by Engr-in-Charge including hacking out the same from window or door frame complete all as specified & directed by Engineer-in-charge.Note:Cost of Scaffolding for change of sheet upto four story building also include in the rate. |
| 18 | S&F in repair Urinal spreader of PTMT any colour for fixing with 15mm diapipe. (Minimum weight 60gms) complete all as specified & directed by Engineer-in-charge. |
| 19 | S & F in repair Vitreous china squatting pan of Orissa patten size 580 x 440 white colour including CI S/P trap long size as directedjoint run and leadfront or back inlet with integral footrest including connection to trap and to flushing pipe,anti-syphonage pipe, etc, fixed in repair complete and making good to floor in PCC 1:2:4 complete all as specified & directed by Engineer-in-charge. |
| 20 | S & F in repair Vitreous china premium/1st quality wash basin (under counter), white, size 550x400 mm including S&F all accessories as recommended by manufacturer complete fixed in position in all respect as per manufacturer\"s instructions and all as specified including all Waste fittings, brass,chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed, Note : The items for counter will be measured and paid separately. |
| 21 | S&F in repair PVC connection 450mm long and 15 mm dia with brass fly nut at both ends complete all as specified & directed by Engineer-in-charge. |
| 22 | S & F in repairs brass chromium plated Health faucet with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified & directed by Engineer-in-charge. |
| 23 | Supply & Fixing in repair chromium plated shower rose 125mm round shape fancy type fixed to 15mm bore pipe complete all as specified & directed by Engineer-in-charge. |
| 24 | S & F in repair Angular Stop Cock,CP,fancy type with wall flange, fancy type chromium plated cast copper alloy screwed down, high pressure, screwed ends for 15mm bore of iron pipe or for union and fixed in position complete all as specified & directed by Engineer-in-charge. |
| 25 | Taking up or down steel tubing 20 mm and connections, including cleaning for re fixing or removal complete all as specified & directed by Engineer-in-charge. |
| 26 | Supplying and laying of CPVC pipes 20 mm external Dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified & directed by Engineer-in-charge. |
| 27 | S&F CPVC Brass Elbow 20mm ext dia complete all as specified & directed by Engineer-in-charge. |
| 28 | S&F Brass Tee 20 mm Ext dia complete all as specified & directed by Engineer-in-charge. |
| 29 | Taking up or down steel tubing 25 mm and connections, including cleaning for re fixing or removal complete all as specified & directed by Engineer-in-charge. |
| 30 | Supplying and laying of CPVC pipes 20 mm external Dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified & directed by Engineer-in-charge. |
| 31 | S&F CPVC Brass Elbow 25 ext diacomplete all as specified & directed by Engineer-in-charge. |
| 32 | S&F Brass Tee 25 mm Ext dia complete all as specified & directed by Engineer-in-charge. |
| 33 | Supply and fixingin repair 15mm bore fancy type pillar taps cast copper alloy with capstan heads, chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shank supply and fixing ly nuts for iron pipe complete all as specified & directed by Engineer-in-charge. |
| 34 | S & F in repair Bib taps,CP,fancy type long nose with wall flange screwed for 15mm bore of iron pipe or for brass ferrule and fixed in position complete all as specified & directed by Engineer-in-charge. |
| 35 | S&F in repairs 15mm bore stop valves , cast copper alloy, chromium plated fancy type with long shank cup (Concealed type) screwed down , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed by Engineer-in-charge. |
| 36 | S&F in repairs Tubular towel rail brass chromium plated 20 mm diaD-type 60 cm long between flanges, including brackets and fixed to walls, complete all as specified & directed by Engineer-in-charge. |
| 37 | M&L PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement etc complete, fixed in repair complete all as specified & directed by Engineer-in-charge. |
| 38 | Taking down eaves gutters and rainwater pipes (any type or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories complete all as specified & directed by Engineer-in-charge. |
| 39 | S & F PVC (SWR) 110 mm bore pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified & directed by Engineer-in-charge. |
| 40 | S & F PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed by Engineer-in-charge. |
| 41 | S & F in epair PVC (SWR) 110mm bends any radius complete all as specified & directed by Engineer-in-charge. |
| 42 | S&F in repair PVC (SWR) vent cowl 110mm dia complete all as specified & directed by Engineer-in-charge. |
| 43 | S&F in repair PVC (SWR) 110mm dia in junction single, (Single T) equal or unequal complete all as specified & directed by Engineer-in-charge. |
| 44 | S & F in repair stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for fixing 110mm dia PVC pipe, including bolts and nuts and securing ends of stays to wall or roof complete all as specified & directed by Engineer-in-charge. |
| 45 | S & F n epair PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed by Engineer-in-charge. |
| 46 | S & F n epair PVC (SWR) 75 mm bore pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified & directed by Engineer-in-charge. |
| 47 | S & F n epair PVC (SWR) 75mm bends any radius complete all as specified & directed by Engineer-in-charge. |
| 48 | S&F in repair PVC (SWR) 75mm dia in junction single, (Single T) equal or unequal complete all as specified & directed by Engineer-in-charge. |
| 49 | S & F in repair stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for fixing 75mm dia PVC pipe, including bolts and nuts and securing ends of stays to wall or roof complete all as specified & directed by Engineer-in-charge. |
| 50 | Demolition of cement concreteun-reinforced in ground floors and pavings n.exc 15cm thickness complete all as specified & directed by Engineer-in-charge. |
| 51 | M&L broken bricks filling of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in-charge. |
| 52 | M& L plain cement concrete 1:2:4 type by using 20mm graded stone agregateas in flooring with water proofing compound @ 2% dosage (1kgs) in 50kg cement including demolition of cement concreteun -reinforced in ground floors and pavings n.exc 15cm thickness complete all as specified & directed by Engineer-in-charge. |
| 53 | Supply of SBR based waterproofing compound @ 2% dosage by weight of cement (1kgs) of 50kg cement used to be mixed in cement concrete as water proofing and hardening complete all as specified & directed by Engineer-in-charge. |
| 54 | M & L For applying Pitch Free PU based Liquid applied single component elastomeric seamless, water and vapor proof membrane system Nitoproof 600PF for concrete @ 2.50 kg/m2 (2 coats). Typical applications will include roofs, podiums, balconies, floor slabs, suspended floors, patios, bathrooms, inspection pits, swimming pools, bridge decks, Conforming Tensile Strength (2N/mm2 ) (ASTM D412) / Tear resistance (15 kN/m) (ASTM D624-00 and Crack bridging (ASTM C836 / ASTM C1305 modified)2mm. After 72 hours of curing, flood test can be carried out to a minimum depth of 50mm of water for 24 hours. Drains shall be plugged and barriers placed to contain the water including taking down of existing treatment complete all as specified & directed by Engineer-in-charge.Note : All above operations to be done in presence of auth applicator in order all as specified and directed. |
| 55 | M&L for Non Skid ceramic tiles colour tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed IN epoxy grouting only including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6for laying floor finishes complete all as specified & directed by Engineer-in-charge. Note : Work will be in patches or in bulk |
| 56 | M&L for 25mm thk PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in subbase of floors & finishing the surface even & smooth without using extra cement complete all as specified & directed by Engineer-in-charge. |
| 57 | M & L for Machine cut kota stone slab flooring 20-25mm thick over, laid over cement screed base , jointed and pointedwith grey cement slurry mixed with pigment over 20mm thick cement mortar 1:6 screed bed to match the shade of the slab including rubbing and polishing including dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid beded and pointed in any morter complete all as specified & directed by Engineer-in-charge. |
| 58 | M & L for Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar over 10 mm thickcement plaster 1:3jointed and pointed with grey cement slurry mxed with pigment to match the shade of the slab including rubbing and polishing including dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid beded and pointed in any morter complete all as specified & directed by Engineer-in-charge. |
| 59 | M & L Granite (Jodhpur Red) work (table rubbed and polished) for wall lining / partition b/w urinals and for counter wash basin10mm thick in cement mortar (1:3) and pointing / fixing with epoxy grouting only using marble dust with admixture of pigment to match with shade of granite including cleaning of damaged granite and fix with epoxy grouting only.including dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid beded and pointed in any morter complete all as specified & directed by Engineer-in-charge. |
| 60 | M&L for Coloured Glazed ceramic tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in epoxy grouting only to match & including 10 mm thick as backing coat in cement mortar (1:4)incl dismantling of wall tiling includingbacking coat, removing rubbish off the premises complete all as specified & directed by Engineer-in-charge. |
| 61 | M & L for Chipping of 25-30 mm average thickness unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead. further applying polymer based bond coat on the prepared old surface of concrete /masonry to receive new polymer mortar/polymer modified mortar with two coats of Thermax TM Bond AR as per manufacturer specifications. Laying of polymer modified mortar shall be completed within the overlay time of bonding coat. This bond coat act as bonding agent between old and new concrete.further applying to the damaged concrete portion of slab / columns / beams / chajjas / parapet / roof projection/balcony/staircase with single component, fiber reinforced, dual shrinkage- compensated thixotropic, cementitious patch repair polymer modified mortar ThermaxBS 5F (having the technical parameters mentioned in material specifications ) capable of applying up to 25-30 mm thick in singlelayer initially by hand and finishing with troweled carefully compacting the same around the rebar and finishing to bring it in line with existing concrete surface with an average specified thickness. its material consumption is 50kg/sqm for 25-30 mm thickness complete all as specified & directed by Engineer-in-charge.Note : The quoted rate by the contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20 mtr height. |
| 62 | M & L for precast cement concrete solid block masonry exc 10cm in width and setting in CM 1:6 type C1, 1:3:6 including Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins, arches, pillars etc complete all as specified & directed by Engineer-in-charge. |
| 63 | Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified & directed by Engineer-in-charge. |
| 64 | M&L for rendering 15 mm thick readymade plaster on inner/outer walls with approved make by adding 17-19% of potable water by weight of material. For thickness above 15 mm it is recommended to be applied in multiple layers. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3 complete all as specified & directed by Engineer-in-charge.Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20mtr height. |
| 65 | M&L for rendering 5-10 mm thick readymade plaster on inner/outer walls and Ceiling with approved make by adding 17-19% of potable water by weight of material. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3 complete all as specified & directed by Engineer-in-charge.Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20mtr height. |
| 66 | M&L for Preparing of new plaster surface and applying three coat of white wash on newly plaster surface of wall complete all as specified & directed by Engineer-in-charge. |
| 67 | M&L for Preparing of new plaster surface and applying three coat of white wash on newly plaster surface of ceiling complete all as specified & directed by Engineer-in-charge. |
| 68 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified & directed by Engineer-in-charge. |
| 69 | M&L preparing of plaster surface and apppying of two coat of oil bound distemper on newly plaster surface over a coat of alkali primer over plastered surface of wall to prepare the surface even and smooth complete all as specified & directed by Engineer-in-charge. |
| 70 | M&L for preparation of old decorated existing surfaces including cornices, plasterd or unplasterd surfaces by brooming down or steel wire brushing moulds, moss efflorescent salt and trading oil and gresy spots and applying one coat of white wash on wall complete all as specified & directed by Engineer-in-charge. |
| 71 | M&L for preparation of old decorated existing surfaces including cornices, plasterd or un plasterd surfaces by brooming down or steel wire brushing moulds, moss efflorescent salt and trading oil and gresy spots and applying one coat of white wash on ceiling complete all as specified & directed by Engineer-in-charge. |
| 72 | M&L for washing/rubbing down and stopping of distempered, plastered and painted surfaces of wall including cornices etc and making good of holes by filling holes in plastered surfaces with POP mixed with distemper and applying one coat ofdistemper oil emulsion complete all as specified & directed by Engineer-in-charge. |
| 73 | M & L for Mirror polishing on old marble/ granite/ Kota stone/ stone work where ever required to give high gloss finishcomplete all as specified & directed by Engineer-in-charge. |
| 74 | Material & Labour for preparation of old surfaces of wall and applying one coatof 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over old surfaces complete all as specified & directed by Engineer-in-charge. |
| 75 | Dismantling/Demolition of existing roof terracing of cement/brick concrete(un-reinforced) and existing water proofing treatment of any thickness in any position on top of roof of building, cleaning surface of roof with brush/mechanical brush and with water throughly to romove all dust/dirt and loose particles to expose bare concrete roof slab and romoval of rubbish/demolished material out side MD land complete all as specified & directed by Engineer-in-charge.Note: Demolition should be done by chiselling. |
| 76 | M&L for PCC (1:2:4) Bo using 12.5 mm graded stone aggregate as in levelling padding course over RCC roof surface including rounded or chamferred on edges etc., with approved water proofing compound all as per manufacturer\"s instructuions on the roof surface to achieve requisite slope complete all as specified & directed by Engineer-in-charge.(Note :- Supply only water proofing compound shall be measured & paid separately). |
| 77 | Supply only Liquid water proofing compound complete all as specified & directed by Engineer-in-charge. |
| 78 | M&L for providing APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application incl applying evenly bitumen tack coat primer of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces and laying over finished surface with screed of 25mm thick CM 1:4 with water proofing compound complete all as specified with the following specifiations :- |
| 79 | (a)Cleaning existing surface properly. (b)Apply oil bound bitumen primer @ 0.40 lit/Sqm manufactured by the same agency as that of APP with a density of 0.87 -0.89 Kg/Lit at 25 Degree Centigrade on the prepared dry roof surface.(c)Providing and Laying APP modified water proofing membrane reinforced with non wooven polyster matt with physical propertities as under :-(i) Membrane weight >3.6 Kg/Sqm .(ii)Net wooven polyster weight >160 gm/Sqm (iii) Softening point of membrane > 150o C(iv)Joint Tensile strength Longitudiual > 650 Sq Cm at 230o C & Transverse > 450/ Sq cm (v)Tear strength - Longitudual > 300 N & Transverse > 250 N Direction(vi)Elongation > 30 %(vii)Impermeability under water pressure > 3 Kg/Sq cm Note:-APP membrane shall be laid using butane torch by Torch application with minimum 10 cm side overlap and 15 cm end lap.The laying of membrane shall be got done through authorised applicator of manufacturer of membrane.(d)Over the membrance provide a finishing with solar reflective bituminous aluminium paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane |
| 80 | Taking down carefully surface aluminium or copper point wiring with PVC casing-caping/conduit(light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete all as specified & directed by Engineer-in-charge. |
| 81 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-charge. |
| 82 | M&L Point wiring used approved colour coding as per IS (Red, Black and Green) for single phase circuits), with multi-stranded copper conductor 2.5 sqmm nominal cross -sectional area, single core, PVC insulated and unsheated FRLSH cable 1100 volts grade, ISI 694 marked with valid CML No. in and including medium grade, PVC concealed conduit MMS, ISI marked of dia not less than20 mm and conduit accessories conceled in wall/roof/floor etc,ISI marked with valid CML No. (IS-9537 - 1983 for condits and IS : 3419 - 1976 for conduit accessories) with terminated to new pressed flush metal boxes readily available cover with outer plates inner plates et, suitable for mounting modular type switches, socket fan regulator etc PVC insulated multistanded copper conductor 2.5 Sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-Note : Modular switch and socket shall be measured and paid separately. |
| 83 | One light point controlled by one switch. |
| 84 | One fan/exhaust fan point controlled by one switch. |
| 85 | One light point controlled by two, 2 way switches. |
| 86 | One socket outlet 6 amp controlled by one switch on the same board with other switches. |
| 87 | All as per item No 82.00 here on before but with copper conductor cable of nominal class area 2.50 sq mm for phase ,neutral & earth for One 2/3 pin socket outlet 5Amps on independent board. |
| 88 | All as per item No 88.00 here on before but with copper conductor cable of nominal class area 4.0 sq mm for phase ,neutral & earth for power socket point 15 A . |
| 89 | S/F modular switch one way 6A, 1 module .Make : Havells crabtree complete all as specified & directed by Engineer-in-charge. |
| 90 | S/F modular socket 6A-2/3 pin combined 2 module.Make : Havells crabtree complete all as specified & directed by Engineer-in-charge. |
| 91 | S/F modular switch socket combined 6A/16A , 6 pin, 3 module complete all as specified & directed by Engineer-in-charge. |
| 92 | S&F ceiling rose 6 amp, 3 plates polycarbonate body complete all as specified & directed by Engineer-in-charge. |
| 93 | S&F modular fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete all as specified & directed by Engineer-in-charge. |
| 94 | S & F for MCCB DB VTPN 4 way 415 V double door IP 54 with provision for FP MCCB/Isolator/RCCB etc as incommer and SP/TP MCBs as out going complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply complete all as specified & directed by Engineer-in-charge. |
| 95 | S & F in repair/replacement for MCB DB TPN 4 waydouble door IP 43 complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge. |
| 96 | S & F in repair/replacement for MCB DB SPN 8 waydouble door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge. |
| 97 | S & F MCCB 4P415volts 16 KA suitable for fixing on VTPN DB of capacity 100 Amps with extended terminals complete all as specified & directed by Engineer-in-charge.Note:- Suitable size and frame of MCCB required as per existing DBs at site. |
| 98 | Supply and fixing MCB TPN 100 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity \"C\" curve complete all as specified & directed by Engineer-in-charge. |
| 99 | Supply and fixing MCB\"s single pole nuetral 40 to 63 Amps, 240 Volts,10 KA rapturing capacity \"C\" curve complete all as specified & directed by Engineer-in-charge. |
| 100 | Supply and fixing MCB\"s single pole 40 to 63 Amps, 240 Volts,10 KA rapturing capacity \"C\" curve complete all as specified & directed by Engineer-in-charge. |
| 101 | Supply and fixing MCB\"s single pole 10 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity \"C\" curve complete all as specified & directed by Engineer-in-charge. |
| 102 | M & L in repair for submain wiring with approved colour code/as per IS (RYB,black & green for three phase) concealed conduitcircuit with four single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLSH) in conduit including one run of PVC insulated multistrandedcopper conductor nominal cross sectinal area of 6.00 Sqmm (FRLSH) of continous earth wire green in colour complete all as specified & directed by Engineer-in-charge.Note :-Four runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable shall be paid as one unit length. |
| 103 | M & L in repair for submain wiring with approved colour code/as per IS (Red,black & green for single phase) concealed conduitcircuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLSH) in conduit including one run of PVC insulated multistrandedcopper conductor nominal cross sectinal area of 6.00 Sqmm (FRLSH) of continous earth wire green in colour complete all as specified & directed by Engineer-in-charge.(Note :- Two runsof 6.00 Sqmm cable & one run of 6.00 Sqmm cable shall be paid as one unit length. |
| 104 | S&F ofGeyser/AC Box having 20 Amp MCB SP enclosure as incomer complete all as specified & directed by Engineer-in-charge. |
| 105 | Supply and fixing in repairs ceiling fans complete with blades, down rods,electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)including taking down of u/s ceiling fan and deposited to MES store yard complete all as specified & directed by Engineer-in-charge. |
| 106 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified & directed by Engineer-in-charge. |
| 107 | M & L for maintenance free chemical earthing with copper plating earthing electode inner pipe dia 42mm and outer pipe dia 76mm coating thickness of 250 mircrons over the rod and 3 mtr long duly inserted in ground by making a bore hole of 250 mm dia, 16 feet deep.Earthing enhcancing compound of 50 kg in sullery form shall be poured in hole after insertion of eletrode, remaining portion of hole shall be filled with excavated earth, interconnectedwith copper strip of size 20x3 mm and connected by means of exothermic brazing & protected by GI pipe light grade 32 mm bore andPCC (1:3:6) type C1 earth chamber & cast iron earth pit cover 300x300x3 mm connecting to test point & testing on ground complete including excavation, earth work, boring in any type of soil strata & cleaning of site complete all as specified & directed by Engineer-in-charge. |
| 108 | Note :- (i) Cost of copper strip 20x3 mm and 32 mm dia GI pipe light grade required for interconnection of copper plate earth electrode 76 mm dia earth electrode is deemed to be included in unit quoted rates.The unit rate includes copper strip and protection pipe upto 7.5 metre.(ii) Cost of earth work, boring, PCC earth pit, CI cover, testing of earth after completion, connecting and commissioning is deemed to be included in unit quoted rates.(iii) Marking & painting of earth pit with iron plate of suitable size is deemed to be included in unit quoted rates. |
| 109 | (iv) The boring will take place for 3 meter depth & 100 mm dia for copper earth electrode pipe.Earth enhance compound to be filled around the earth electrode in 100 mm dia in 3 layers of 1 mtr each by means of PVC pipe of 100mm dia as casing/formwork.The remaining volume of bore shall be filled with clay soil (available from vicinity) in 3 layers of 1 mtr each.The PVC pipe to be removed sinultaneously.The cost of all this is deemed to be included in the quoted rate.(v) Minimum distance between each earthing is not less than 3 running meter.(vi) Testing of earthing shall be conducted and result should be less than 1.00 Ohms |
| 110 | M&L for Earth continuity strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to DBs or any other indicated situation for loop earthing with copper strip of size 20 x 3 mm complete all as specified & directed by Engineer-in-charge. |
| 111 | S & F in repair/replacement of surface and wall mounted LED tube light along with fixture ,4 ft ,20 W ,extruded aluminium housing provided for efficient heat disspation with polycarbonate ,operating voltage 240 V ,50HZ ,AC supply and operating tempureture 0 to 50 C ,power factor >0.9 ,lumen output > 2000 and provision of new 3 core multistanded copper conductor of size 23/0.193 from ceiling rose to fitting with white colour flexible pipe complete all as specified & directed by Engineer-in-charge. |
| 112 | S & F in repair/replacement of LED tube light fitting 10 watt tube LED Neutral white in colour, 600 mm in length wall mounted LED batten,extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver,optic diffused typeENDURA LINER NEO including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required complete all as specified & directed by Engineer-in-charge. |
| 113 | S & F in repair/replacement of building security light fitting LED 35 Watt IP 66 IK 07 pressure dia cast aluminium housing with high efficient LED as lihjting souce and PC cover having TOP opening sepreate drive compartmentetcand connecting complete all as specified & directed by Engineer-in-charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy