| 1 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for column & wall foundation, laying of pipe, UG Cable etc and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Returning, filling in, including spreading,levelling, watering and well ramming in layers n exc 25 cm layers in soft/loose soil complete all as specified and directed. |
| 3 | Removing excavated material (Soil) not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed. |
| 4 | S&F Epoxy insulator (Heavy duty) 75mm suitable for fixing of eathing strip/GI earth wire complete all as specified and directed. |
| 5 | M&L maintance free chemical Earthing system complete with 3 Nos pure copper earth rods 17mm did, 3000mm long electrode dipped fully in earthing Ennob chemical Backfill compound (EBFC) with minimum 3 Nos of 30Kg bag buried in ground to bore holes 100mm dia vertically to a depth not less than 3.5 mtr deep below the ground level with top edge of earth electrode at a depth not less than 3000mm below normal ground level, interconnected each other parallely in traingle shape horizontaly with provision of copper bus bar of size 32mm x 6mm for interconnection with copper earth lead strip 32mmx6mm for further connected to test point block NABL lab certified back fill eath enhancing compound for filling 3 x bore holes with soil mixedso as to achieve eath resistance below 1 Ohms includingnecessary Excavation in Soft/Loose Soil, Returning, Filling in and removal of Surplus Spoil upto a distance of 50.00 METRE and provision of Poly Plastic Pit cover for each eathingand testing on completion including taking dismantling/taking unserviceable Earthing complete all as specified and as directedNOTES : (i) The unit rate includes for protection pipe and copper strip from top of earth plate up to 7.00 meter above ground level.(ii) MOU With Manufacturer’s of Chemical Earthing shall be submitted during Technical bid documents and financial bids of only those tenderers shall be admitted whosoever MOUs are found to be satisfying contract conditions. MOU shall also cover the aspect towards Guarantee and defect rectification during guarantee period |
| 6 | S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles duly fixed over insulatorsor any other indicatedsituation for loop earthing etc as required with 32 x 6mm copper strip duly brazedcomplete all as specified and directed. |
| 7 | S&F Test point terminal block made of gun metal or Phosphorus bronze size 75 x 75 x 25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw in a test point boxcomplete all as specified and as directed. |
| 8 | M&L 40mm bore GI pipe light grade with all necessary fittings (ISI marked) as in earthing strip protection, laid in trenches/ road/floor complete all as specified and as directed. |
| 9 | S&F Junction Boxof size 217x253x115 mm made out of Polycarbonate material totally enclosed, dust and vermin proof, (without mounting plate) with transparent lid, rubber gasket, water tight, IP 66 protection for housing of test pointand fixed on wall with sutable size of screws as directed complete all as specified and directed. Note :- Cable glands shall be fixed in inlet and out let of junction box and rate of Cable glands is deem to be included in quoted rate. |
| 10 | S&F Junction Boxof size 155x210x92 mm made out of Polycarbonate material totally enclosed, dust and vermin proof, with knockout for cable entry with terminal suitable for 10-25sqmm canleIP 66/67 protection including aluminum bus bar and fixed on wall with sutable size of screws as directed complete all as specified and directed. Note :- Cable glands shall be fixed in inlet and out let of junction box and rate of Cable glands is deem to be included in quoted rate. |
| 11 | Supply & Laying XLPE LT heavy duty UG Cable of size 10 Sqmm 2 Core laid in trench /floor/on wall/service connection PVC Insulated, sheathing and armoured 1100 Volts grade with aluminium conductor including connection to the main switch/cut out MCB/MCCB with necessary lugs after cutting to required length complete all as specified and directed. |
| 12 | S&F 40 Watt, IP 65 LED post top light, aesthetically designed with symmertical light distribution, spun aluminum landscape luminaire with high power LED as light source, clear cover for bright illumination and connecting with and including three core twisted flexible copper conductorof size 23/0.193 from control DB to fitting/driver complete all as specified & as directed. Note:- (i) Mounting the LED post top light including PCC type C2 1:3:6, (20cm below GL and 15 cm above GL) including form work, necessary earth work and fixing arrangement is deemed to be inclusive in the Unit rate Quoted (ii) GI pipe as required will be measured and paid seperately under appropiate item |
| 13 | Excavating in post holes (or similar holes) in soft/loose soil, each n exc 0.5 cu. m, getting out,and removing soil out of the site ,complete all as specified and as directed. |
| 14 | M&L PCC (1:3:6) type-C2withusing 40 mm graded crushed stoneaggregate as in foundations, filling and mass concrete complete all as specified and as directed. |
| 15 | M&L providing plain cementconcrete type C1 (1:3:6), (using 20mm graded stone aggregate), as incopings, bed plates and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 16 | S&F MS work for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including necessary prepration of surface and applying a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 17 | M&L TMT bar 10 mm diaand over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and as directed. |
| 18 | M&L TMT bar 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and as directed. |
| 19 | M&L TMT bar 10 mm diaand over, cut to length, bent to shape required, including cranking, hooking ends as in chain link fencing complete all as specified and as directed. |
| 20 | M&L preparation new iron and steel surfaces of any description, exc 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 21 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long, Diameter of neck 5-10mm complete all as specified and directed. |
| 22 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed |
| 23 | Supply only chain link MS galvanized fencing 4mm dia and size as ordered, complete all as specified and as directed. |
| 24 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed |
| 25 | S&F mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe.290.Gde-E-165 including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer, complete all as specified and as directed. |
| 26 | S&F 0.8mm thick Mild steel, plain, black sheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed. |
| 27 | M&L PCC (1:4:8) type-D2withusing 40 mm graded crushed stoneaggregate as in foundations, filling and mass concrete complete all as specified and as directed. |
| 28 | M&L RCCnominal mix using Type A1 (1:1.5:3) (20 mm graded aggrgate) for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass co, complete all as specified and directed. |
| 29 | M&L RCCnominal mix using Type A1 (1:1.5:3) using 20 mm graded aggregate for Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 30 | M&L Form work for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat, rought finished surfaces of concerete complete all as specified and directed. |
| 31 | M&L Formwork to sides of pillars, posts, struts, piers, columns and stanchions, square rectangular or polyggonal rought finished surfaces of concerete complete all as specified and directed. |
| 32 | M&L Granite (of any type) tiles 18-20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in 20mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, Rounding to edges of stone slabs one edge, complete all as specified and directed. |
| 33 | S&F Anodised aluminium snap grid frame work for false ceiling,Size of grid 605 x 605mm, includinng Hangers 4mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, with and including 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to Aluminium framework with screws, complete all as specified and as directed. |
| 34 | Taking down ceiling fan of any size/description, sealing cable end, replacement of down rod of fan and refixing of fan in the existing position complete all as directed.Note: (i) Down Rod shall be measured and paid seperately under appropiate item at Supply only rates |
| 35 | Supply only anti sucide fan rod for ceiling fan 1200/1400mm sweep, whie in colour, thickness of of rod 1.84( + 0.05)mm on zinc plated MS pipe with zinc plated spring mechanism, MSME Tested for 15 Kg weight bearing capacity and breaking breaking at impact load of + 22 Kg, fan down rod opens from its center and spring hidden in pipe, expands to land person on ground safely, including drilling bracket, replacement of Clamps for hanging of ceiling fan with rubber nuts, bolts etc where ever as required complete all as manufacturers instructions and as directed. |