| 1 | Surface excavation in soft/loose soil, n.exc(not exceeding) 30 cm deep and averaging 15cm deep and getting out, complete all asdirected. |
| 2 | Excavating in post holes (or similar holes) in soft/loose soil, each n exc 0.5 cu. m, getting out,and removing soil out of the site ,complete all as specified and as directed. |
| 3 | M&L plain cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 4 | M&L plain cement concrete type B-2 (1:2:4) using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 5 | M&L Hardcore of gauge n exc. 63 mm, Broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface,complete all as specified and directed. |
| 6 | M&L 100mmthick cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 7 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;, complete all as specified and directed. |
| 8 | S&F Prepainted galvalume aluminium zink coating GI based corrugated/semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 9 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and as directed.. |
| 10 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer complete all as specified and as directed. |
| 11 | M&Lpreparation of new steel surfaces of any description over 10cm width or girth and applyingtwo coats of synthetic enamel paint complete all as specified and directed. |
| 12 | Removing excavated material (soil) n exc 50 m & depositing where directed at a level n exc 1.5 m, complete all asdirected. |
| 13 | Taking out existing unserviceable water roof treatment of any descriptionfrom RCC roof slab, parapet etc complete all as specified anddirected . |
| 14 | M&L Cleaning of old concrete surfaces of roof, picking sweeping cleaning the surface to remove all loose dust and thoroughly washing down with clean water and dried and applying cement slurry @ 3Kg/Sqm over RCC slab complete all as specified anddirected . |
| 15 | M&L PCC 25mm thick average thickness Type B0 (using 20mm graded aggregate) as levelling course to roof surfaces finished even and fair including demoliation of existing unserviceable PCC padding complete all as specified anddirected . |
| 16 | M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following course of treatment/specification from bottom to top, complete all as specified and directed:-(i) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm.(ii) Supply and laying 3mm thick APP based olymeric membrane of approved manufacturer with weight not less than 3.50 Kgs per Sqm, reinforced with non-woven polyester febric weight not less than 160gms per Sqm.Polymeric membrane shall be taken to a height of 30cm(minimum) and than inserted inside the groove of parapet wall and shall be finished by a membrane flashing.(iii) Two coats of Solar reflective bituminious Aluminium paint of approved brand to be provided over the APP membrane as per manufacturers instructions. Note : (a) Work shall be carried out through specialized applicator approvred by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted.(b) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (c) A minimum overlap of 100mm and 75mm should be made at the endand sides of the polymeric membrane respectively and sealed alloverlaps and joints as per manufacturers instruction |
| 17 | S&F in repair, 1.25mm thick Steel rolling shutters, with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: gear operated type with bevel gear box and crank handle |
| 18 | Demoliation of cement Concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level)complete all as specified and as directed. |
| 19 | M&L 100mmthick cement concrete type B-2 (1:2:4) using 40 mm graded stone aggregate as in floor/ hardstanding finished even and fair complete all as specified and directed. |
| 20 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternatebays (not exceeding 2 Sqm each)and finished even and smooth without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed. |
| 21 | Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete including removing debries of the site complete all as specified and as directed. |
| 22 | M&L rendering 20mm thick with cement mortar 1:4on fair faces of brick workin two layers (10mm and 10mm) sperately mixed with water proofing compund in top layer as per manufacturers instruction and finishing the surfaces even and faircomplete all as specified and directed. Note:- WPC shall be measured & paid separately |
| 23 | M&L Rendering 15 mm thick on other thanfair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and fair complete all as specified and as directed. |
| 24 | M&L rendering 5 mm thick on ceiling or concrete Surfaces in cement mortar 1:3 finished even and smooth. (without using extra cement), complete all as specified and directed. |
| 25 | Supply only integral Water proofing compund, complete all as specified and directed. |
| 26 | M&L preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm complete all as specified and directed. |
| 27 | M&L preparation of new wall surface applying Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specificationover new surface over 1 mm thick wall care putty,complete all as specified and directed. |
| 28 | M&L preperation of new surfaces of ceilings and applying three coats of white wash,complete all as specified and as directed |
| 29 | M&L complete removal of existing finishes, Preparation old decorated plastered surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces. complete all as specified and as directed. |
| 30 | M&L complete removal of existing finishes, preperation of old surfaces of ceilings and applying three coats of white wash,complete all as specified and as directed |
| 31 | M&L complete removal of existing finishes, Preparation old decorated plastered surfaces of wall andapplying Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specificationover new surface over 1 mm thick wall care putty,complete all as specified and directed. |
| 32 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. seperating serviceable fittings/fixtures, keeping in safe custody reuse under respective item and removal of unserviceable material from site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 33 | Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed |
| 34 | Taking down the existing unservicable sub main wiring of any type / description including making good the disturbed surfaces to match with the existing finishes complete all as directed. |
| 35 | Taking up the existing unservicable UG cable of any type/ description as from any position complete all as directedNote : Earthwork will be measured and paid seperately. |
| 36 | M&L concealed point wiring for One light point/Ceiling fan/Exhaut fan/bell pointcontrolled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i)Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles.(ii) Cost of cutting chases in wall and making good the distrubed surfaces is deemed to be inclusive in the unit rate quoted(iii) Where concealing of conduit is not feasible i.e. on surface ofRCC roof slab, beam etc, conduit shall be fixed on surface with necessary saddles at no extra cost. |
| 37 | All as per item No 36here-in-above but One socket out let 5/6 amps point on the same board |
| 38 | All as per item No 36here-in-above but One socket out let 5/6 amps point on the independent board |
| 39 | M&L concealed point wiring for One one socket outlet 15 Amps point on independent board pointcontrolled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i)Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles.(ii) Cost of cutting chases in wall and making good the distrubed surfaces is deemed to be inclusive in the unit rate quoted (iii) Where concealing of conduit is not feasible i.e. on surface ofRCC roof slab, beam etc, conduit shall be fixed on surface with necessary saddles at no extra cost. |
| 40 | S&F Switch piano, flush type single pole, one way 5/6 Amp complete all as specified and as directed. |
| 41 | S&F Socket outlet 2 in 1, 3 pin, 5/6 Amps flush type complete all as specified and as directed. |
| 42 | S&F Switch socket combination 2 in 1, 3 pin, 5/6 Amp flush typeuniversal complete all as specified and as directed. |
| 43 | S&F Switch socket combination 2 in 1, 3 pin, 15/16 Amp flush type universal complete all as specified and as directed. |
| 44 | S&F ceiling rose, 3 phase PVC/ polycarbonate, insulated body, three terminals, complete all as specified and as directed |
| 45 | S&F lamp holder, insulated PVC/ Polycarbonate body, with back plate suitable for batten/anglefittings complete all as specified and directed. |
| 46 | S&F LED bulb 10 watt5 STAR LAMPwith B 22 base capacity 1200 lumencomplete all as specified. |
| 47 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), IP-43 doubledoor, Single pole & neutral with 200 Amps rated bus bar, 240 Volts,IP-43 protection,complete including. blanking plates as required &flush to wall/other surface complete all as specified and as directed |
| 48 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), IP-43 doubledoor, Triplepole & neutral with 200 Amps rated bus bar, IP-43 protection,complete including. blanking plates as required &flush to wall/other surface complete all as specified and as directed |
| 49 | S&F MCB, DP, B Series 240 Volts, 32 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 50 | S&F MCB, SP, B Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 51 | S&F MCB, TPN C Series 240 Volts, 63 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 52 | S&F LED luminarie tube light fitting basic all purpose surface/wall mounted decrotative slim with polycarbonate housing & integrated electronic driver, 4 feet LED with high efficient LEDs 20 watt, (or nearest next higher wattage) with all accessories, suitable for operation on AC, single phase 220/230 Volts, 50 Hz, 6500K complete all as specified and as directed. |
| 53 | S&F energy saving & environment friendly long life 20 Watt,(or nearest next higher wattage)CT ≥ 6500 K, LED building security light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete withintegrated type, with high efficiency electronic driver, surge suppressor of 5 KV or more & high brightness LEDs, luminaire efficacy > 110 lumens/Watt, power factor ≥ 0.90, operating range 140 to 270 V, 50 Hz complete including GI pipe bracket of adequate size as required (Light Grade) of length 1.2 mtrs bent to shape and fixed with 40mm x 5mm MS flat with necessary nuts, bolts, washers etc, painting with two coats of syntheic enamel paint over a coat of primer and connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed. |
| 54 | S&F energy saving & environment friendly, robust Highbay LED down light of 80 watt with PDC housing suitable foe ceiling (surfaces/suspended) mounting with system efficacy ypto 150 lumen/Watt including necessary mounting arrangement including three core twisted flexible copper conductor cable of suitable size all as specified & as directed. |
| 55 | M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE: (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 56 | M & L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed. Note : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid |
| 57 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trenchcomplete all as specified and directed. |
| 58 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Polewith necessary lugs complete all as specified and as directed. |
| 59 | M&L for 40mm bore GI pipe light grade with all necessary fittings (ISI marked) as in cable protection fixed to pole,laid in trenches/road/floor complete all as specified and as directed. |
| 60 | Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 40mm bore (dia) for passing of pipes, complete all as specified and as directed.Note:- Pipe will be measured and paid seperately under appropiate item |
| 61 | M&L earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means ofbolts & nuts,check nuts & washers made of galvanised steel, earth wire protected by and including PCC (1:2:4) type B1 precast RCC cover slab(1:2:4, type B1)reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth wire GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed. |