Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified & directed by Engineer-in-charge. |
| 2 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge. |
| 3 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soil complete all as specified & directed by Engineer-in-Charge. |
| 4 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rockall as specified & directed by Engineer-in-Charge. |
| 5 | Removing excavated soil to a distance not exceeding 50 m and depositingwhere directed at a level not exceeding 1.5 mabove the starting point complete all as specified & directed by Engineer-in-Charge. |
| 6 | Removing excavated material to a distance exc 1.5 Km but n.exc 5 Km and depositing where directed at a level n.exc 1.50m from starting point complete all as specified and directed by Engineer-in-charge. |
| 7 | Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositingwhere directed at a level not exceeding 1.5 mabove the starting point complete all as specified and directed by the Engineer-in-Charge. |
| 8 | Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holesand making good reqd shape for hold fast block for new frame complete all as specified. |
| 9 | Supply and fixing painted pressed steel frame for doors of size 105 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including one shop coat of priming complete. |
| 10 | Supply and fixingpainted pressed steel frame for doors of size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including one shop coat of priming complete. |
| 11 | Taking down shutters of any description exc 1sqm but not exc 2.00 sqm each complete all as specified and directed. |
| 12 | S & F 35mm thick glazed and skelton shutters of 2nd class hard wood (factory made) open rebated and divided to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR-91 Pt-I section 8 clause 8.20 (a) kiln seasoned and chemically pressure treated all as specifeid including stainless steel 304 grade wire cloth ( 0.36mm nominal dia of wire and average width of aperture 1.40 mm ) complete all as specified and directed by Engineer-in-charge and including supply and fixing following items :-(a) Stainless Steel (304 Grade) Finished Butt Hinges 125mm -3 nos per leaf(b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos per leaf(d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16x3000mm- 1 nos per leaf(e) Stainless Steel (304 Grade) Finished Floor Door Stooper- 1 nos per leaf |
| 13 | S & F Factory made ISI marked flush door shutters 35mm thick, BWP conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 2nd class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters complete all as specified and directed by Engineer-in-charge and including supply and fixing following items :-(a) Stainless Steel (304 Grade) Finished Butt Hinges 125mm -4 Nos per leaf(b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf(d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16 x 300mm- 1 No per leaf(e) Stainless Steel (304 Grade) Finished Floor Door Stooper- 1 No per leaf |
| 14 | S & F Steel windows with side hung shutters including projecting type hinge with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed by Engr- in -Charge. |
| 15 | M & L for plain sheet glass plain 3mm thick ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm in each panecomplete all as specified and directed. |
| 16 | M & L for preparation of new wooden surfaces of any description exc 10 cm width or girth and applyingtwo coats of synthetic enamel paint, first quality, over a coat of pink primer on wooden surface complete all as specified and directed. |
| 17 | Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqmincl cutting holesand making good reqd shape for hold fast block for new frame complete all as specified. |
| 18 | S & F Steel ventilator with top hung shutter including hinges, steel peg stay, complete with glazing bars,all as specifid and as directed. |
| 19 | S & F solid PVC door frames of size 50x47mm made out of 5mm plain colour PVC sheet supplying and fixing in opening as per specification and drawing shown in SSRcomplete all as specified and directed. |
| 20 | S & FFactory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification incl the fwg S & F :-(a) Stainless Steel (304 Grade) Finished Butt Hinges 125mm -3 Nos per leaf(b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf |
| 21 | S & F in repairs door closer hydraulically regulated designation No 3 universal type suitable for door shutter 851mm to 1000mm vide and weight between 61 to 80 kg of aluminium (extruded section body) as in repairs all as specified and directed. |
| 22 | S & F in repair 300mm, mild steel, ordinary rat tailrod pattern springs including roller and roller plate, bearing ISI markcomplete including necessary welding work all as specified and as directed. |
| 23 | S&F in repairs Stainlesssteel tubing of 25 mm dia chromium plated min. 1.0 mm wall thickness as in curtain rod complete incl S&F 02 Nos stainless steel brackets/finials fancy type, stops fixed with ss screws etc all as specified & directed.Note : For the purpose of mesurement and payment running length of curtain rod only shall be considered. |
| 24 | S & F in repair 6mm thick of size 600x450mm looking mirror fixed to wall with stainless steel plugs/ connecter/ spacers/ screws etc. chrome finish without any beading, including ends/edges of the mirror to be tapered etched smooth finish etc.complete fixed in position all as specified and directed. |
| 25 | S & F for Rotational moulded polyethylene water storage tanks of 500 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete . |
| 26 | S&F in repair European type water closet including CI P/S trap as directed including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc.,with flush pipe PVC 32mm dia and incl. plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc; and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and including supply and fix of PVC long arm P/S trap so that joint is avoided inside the building as well as in wall and outlet straight away come out of wall in all floors G.F.and taking down existing of any description/size complete in all respect all as specified. |
| 27 | S & F in repair Flushing cistern of PVC 10 ltr. cap. with dual flushing system, valveless syphonic action type, , low level, white/ivory/off white with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified. |
| 28 | S&F in repair PVC connection 450mm long and 15 mm dia with brass fly nut at both ends complete. |
| 29 | S & F in repairs brass chromium plated Health faucet with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 30 | Supply & Fixing in repair chromium plated shower rose 125mm round shape fancy type fixed to 15mm bore pipeall as specified and directed by Engr-in-charge. |
| 31 | S & F in repair Angular Stop Cock,CP,fancy type with wall flange, fancy type chromium plated cast copper alloy screwed down, high pressure, screwed ends for 15mm bore of iron pipe or for union and fixed in position complete fixed as in repair in all respect all as specified. |
| 32 | Taking up or down steel tubing 20 mm and connections, including cleaning for re fixing or removal Complete all as specified and directed by engineer in charge. |
| 33 | Supplying and laying of CPVC pipes 20 mm external Dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 34 | S&F CPVC Brass Elbow 20mm ext dia complete all as specified and directed by engineer in charge |
| 35 | S&F Brass Tee 20 mm Ext diacomplete all as specified and directed by engineer in charge |
| 36 | Taking up or down steel tubing 25 mm and connections, including cleaning for re fixing or removal Complete all as specified and directed by engineer in charge. |
| 37 | Supplying and laying of CPVC pipes 20 mm external Dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 38 | S&F CPVC Brass Elbow 25 ext dia complete all as specified and directed by engineer in charge |
| 39 | S&F Brass Tee 25 mm Ext diacomplete all as specified and directed by engineer in charge |
| 40 | Supply and fixingin repair of fancy typepillar taps cast copper alloy with capstan heads, chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shank supply and fixing ly nuts for iron pipe of 15mm bore fancy type. |
| 41 | S & F in repair Bib taps,CP,fancy type long nose with wall flange screwed for 15mm bore of iron pipe or for brass ferrule and fixed in position complete fixed as in repair in all respect all as specified. |
| 42 | S&F in repairs 15mm bore stop valves , cast copper alloy, chromium plated fancy type with long shank cup (Concealed type) screwed down , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed. |
| 43 | S&F in repairs 15mm dia two way angle cock of brass, chromium plated fancy type glossy finish fixed in repairs completeall as specified and directed. |
| 44 | S&F in repairs Tubular towel rail brass chromium plated 20 mm diaD-type 60 cm long between flanges, including brackets and fixed to walls, complete. |
| 45 | M&L PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement etc complete, fixed in repair. |
| 46 | Taking down eaves gutters and rainwater pipes (any type or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories all as specified and directed |
| 47 | S & F PVC (SWR) 110 mm bore pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and directed |
| 48 | S & F PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 49 | S & F in epair PVC (SWR) 110mm bends any radius all as specified and directed |
| 50 | S&F in repair PVC (SWR) vent cowl 110mm dia complete all as specified and directed. |
| 51 | S&F in repair PVC (SWR) 110mm dia in junction single, (Single T) equal or unequal complete all as specified and directed. |
| 52 | S & F in repair stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for fixing 110mm dia PVC pipe, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 53 | S & F n epair PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 54 | S & F n epair PVC (SWR) 75 mm bore pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and directed |
| 55 | S & F n epair PVC (SWR) 75mm bends any radius all as specified and directed |
| 56 | S&F in repair PVC (SWR) 75mm dia in junction single, (Single T) equal or unequal |
| 57 | S&F in repair PVC (SWR) vent cowl 110mm dia |
| 58 | S & F in repair stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for fixing 75mm dia PVC pipe, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 59 | Demolition of cement concrete (un reinforced) in ground floors and pavings n.exc 15 cm thick(below or above ground level) & removing rubbish out side MD land all as directed by Engineer-in-charge. |
| 60 | M&L for 25mm thk PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in subbase of floors & finishing the surface even & smooth without using extra cement complete all as specified and directed. |
| 61 | Supply of SBR based waterproofing compound @ 2% dosage by weight of cement (1kgs) of 50kg cement used to be mixed in cement concrete as water proofing and hardening complete all as specified and directed. |
| 62 | M & L For applying Pitch Free PU based Liquid applied single component elastomeric seamless, water and vapor proof membrane system Nitoproof 600PF for concrete @ 2.50 kg/m2 (2 coats). Typical applications will include roofs, podiums, balconies, floor slabs, suspended floors, patios, bathrooms, inspection pits, swimming pools, bridge decks, Conforming Tensile Strength (2N/mm2 ) (ASTM D412) / Tear resistance (15 kN/m) (ASTM D624-00 and Crack bridging (ASTM C836 / ASTM C1305 modified)2mm. After 72 hours of curing, flood test can be carried out to a minimum depth of 50mm of water for 24 hours. Drains shall be plugged and barriers placed to contain the water. Note : All above operations to be done in presence of auth applicator in order all as specified and directed. |
| 63 | M&L for Non Skid ceramic tiles colour tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6for laying floor finishes complete all as specified. Note : Work will be in patches or in bulk |
| 64 | M & L for Machine cut kota stone slab flooring 20-25mm thick over, laid over cement screed base , jointed and pointedwith grey cement slurry mixed with pigment over 20mm thick cement mortar 1:6 screed bed to match the shade of the slab including rubbing and polishing including dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid beded and pointed in any morter complete all as specified.complete all as specified and directed. |
| 65 | M & L for Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar over 10 mm thickcement plaster 1:3jointed and pointed with grey cement slurry mxed with pigment to match the shade of the slab including rubbing and polishing including dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid beded and pointed in any morter complete all as specified.complete, all as specified and directed. |
| 66 | M&L for Coloured Glazed ceramic tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in epoxy grouting only to match & including 10 mm thick as backing coat in cement mortar (1:4)incl dismantling of wall tiling includingbacking coat, removing rubbish off the premises all as specified and directed |
| 67 | Dismantling of Trellis work (Jafri), including taking as under of battens in trellis (posts and rails measured separately) complete all as specified and directed. |
| 68 | Material & Labour for 35mm thickprecast cement concrete louvres and jallies type C-0 (1:3:6) using 12.5mm graded stone aggregate(measured solid), in cluding all mouldings and frame set in cement mortar 1:4 complete all as specified and directed. |
| 69 | M&L for APP based polymeric membrane minmum weighing 3 Kg/Sqm and minmum 3 mm thick reinforced with polyster non wove fabric ( wt not less than 150 gms/sqm) including priming of surface by forced application including 15mm thick 1:3 CM with water proofing compound complete all as specified and directed. |
| 70 | M&L Bitumen blown any grade, applied hot, two coats, to concrete surfaces at the rate of 1.5kg. per sq. m per coat complete all as specified and directed. |
| 71 | M & L for Chipping of 25-30 mm average thickness unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead. further applying polymer based bond coat on the prepared old surface of concrete /masonry to receive new polymer mortar/polymer modified mortar with two coats of approved make as per manufacturer specifications. Laying of polymer modified mortar shall be completed within the overlay time of bonding coat. This bond coat act as bonding agent between old and new concrete.further applying to the damaged concrete portion of slab / columns / beams / chajjas / parapet / roof projection/balcony/staircase with single component, fiber reinforced, dual shrinkage- compensated thixotropic, cementitious patch repair polymer modified mortar approved make (having the technical parameters mentioned in material specifications ) capable of applying up to 25-30 mm thick in singlelayer initially by hand and finishing with troweled carefully compacting the same around the rebar and finishing to bring it in line with existing concrete surface with an average specified thickness. its material consumption is 50kg/sqm for 25-30 mm thickness, all as specified and directed as Engineer-in-Charge. Note : The quoted rate by the contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20 mtr height. |
| 72 | Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed. |
| 73 | M&L for rendering 15 mm thick readymade plaster on inner/outer walls with approved make by adding 17-19% of potable water by weight of material. For thickness above 15 mm it is recommended to be applied in multiple layers. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3.Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20mtr height. |
| 74 | M&L for rendering 5-10 mm thick readymade plaster on inner/outer walls and Ceiling with approved make by adding 17-19% of potable water by weight of material. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3.Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20mtr height all as specified and directed) |
| 75 | M&L for Preparing of new plaster surface and applying three coat of white wash on newly plaster surface of wall complete all as specified and directed |
| 76 | M&L for Preparing of new plaster surface and applying three coat of white wash on newly plaster surface of ceiling complete all as specified and directed |
| 77 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces |
| 78 | M&L preparing of plaster surface and apppying of two coat of oil bound distemper on newly plaster surface over a coat of alkali primer over plastered surface of wall to prepare the surface even and smooth complete all as specified and directed |
| 79 | M&L for preparation of old decorated existing surfaces including cornices, plasterd or unplasterd surfaces by brooming down or steel wire brushing moulds, moss efflorescent salt and trading oil and gresy spots and applying one coat of white wash on wall complete all as specified and directed. |
| 80 | M&L for preparation of old decorated existing surfaces including cornices, plasterd or un plasterd surfaces by brooming down or steel wire brushing moulds, moss efflorescent salt and trading oil and gresy spots and applying one coat of white wash on ceiling complete all as specified and directed by Engr-in-charge. |
| 81 | M&L for washing/rubbing down and stopping of distempered, plastered and painted surfaces of wall including cornices etc and making good of holes by filling holes in plastered surfaces with POP mixed with distemper and applying one coat ofdistemper oil emulsion complete all as specified and directed by Engr-in-Charge. |
| 82 | M & L for Mirror polishing on old marble/ granite/ Kota stone/ stone work where ever required to give high gloss finishcomplete. |
| 83 | M&L for Reinforced concrete pipes of dia 200mm bore, class NP2, laid and jointed complete with collars laid in trenches and jointed in CM (1:1) and tested complete all as specified & directed by Engineer-in-charge. |
| 84 | M&L for PCC (1:4:8) type B-2 (using 40mm graded stone aggregate) for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 200mm bore pipe complete all as specified & directed by Engineer-in-charge. |
| 85 | Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins, arches, pillars etc complete all as specified & directed by Engineer-in-charge. |
| 86 | M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified & directed by Engineer-in-charge. |
| 87 | M&L squared rubble walling Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified & directed by Engineer-in-charge. |
| 88 | Material and labour for 15 mm thick rendering in cement mortar (1:4) on other side of lathing of stone, block masonry or concrete surfaces finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge. |
| 89 | Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, including removal of debris to a distance exc 1.5 km but n.exc 2 Km complete all as specified and directed. |
| 90 | S&F in repair 750 x 750 mm, 2.5 Ton load capacity rectangular Heavy Duty Composite FRP (Fibre reinforced polymer) manhole covers with frame for inspection chamber / manhole and other required places including fix to floor with cement concrete complete all as specified and directed by Engineer-in-charge. |
| 91 | Demolition of cement concrete (unreinforced) of any description & in any position not otherwise specifically provided for such as concrete bed of SWG pipe line including demolition of SWG pipes line including demolition of embedded pipes etc and including removal of debris to a distance exc 1.5 Km but n. exc 5 Km.complete all as specified. |
| 92 | Cutting into existing manholes for connection new drains of pipe 150/200/300mm internal drain including cutting out branch channel, disturb portion with CM (1:4)andmaking good as required complete all as specified and directed |
| 93 | M & L for Cement concrete in surface channels1:3:6 (12.5mm graded stone aggregate) including finish the surface even and smooth with using extra cement complete all as specified. |
| 94 | M&L for 100mm thick PCC 1:2:4 type B2 (using 40mm graded agg) as in floorincl finishing even & smooth without using extra cement including demolition of cement concrete in ground floor and pavings not exc 15cm thickness below or above ground level, including removal of debris to a distance exc 1.5 Km but n. exc 5 Km complete all as specified and directed.complete all as specified and directed. |
| 95 | M&L for preparation of new plastered surfaces of wall and applying two coats of white wash complete all as specified and directed. |
| 96 | Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfacescomplete. |
| 97 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes all as specified. |
| 98 | M&L for point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area , single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and inciuding medium grade, Concealed PVC conduit and accessories on wall/roof/floor etc, ISI marked with mild steel/pressed steel sunken box thickness as per IS standard(with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally. and two coats of black bituminous paint over a coat of red oxide primer externally,covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-charge for One light or fan point, controlled by one, one way switch 5 Amps. |
| 99 | One light point controlled by one switch. |
| 100 | One Ceiling /Exhaust fan point controlled by one switch. |
| 101 | one light point controlled by two, 2 way switches. |
| 102 | One socket outlet 6 amp controlled by one switch on the same board with other switches. |
| 103 | All as per Item No 98.00 here-in-before but for one socket outlet of 05 Amps fixed on independent board with 2.5 Sq mm multistranded copper conductor wire FRLS PVC insulated and 2.5 Sq mm multistranded copper conductor wire FRLS PVC insulated as earth wire complete all as specified. |
| 104 | All as per Item No 98.00 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated as earth wire complete all as specified & directed by Engineer-in-charge. |
| 105 | S&F switch piano flush button single pole one way 5/6 amp complete all as specified & directed by Engineer-in-charge. |
| 106 | S&F switch piano flush button single pole one way 16 amp complete all as specified & directed by Engineer-in-charge. |
| 107 | S&F socket outlet2 in 1, 3 pin 6 & 16 amp flush type complete all as specified & directed by Engineer-in-charge. |
| 108 | S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete all as specified & directed by Engineer-in-charge. |
| 109 | S&F hum freeelectronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting upcomplete all as specified & directed by Engineer-in-charge. |
| 110 | S&F Ceiling rose,three terminals PVC/polycorbonate, isolated body complete all as specified & directed by Engineer-in-charge. |
| 111 | S&F of switch piano, flush type, 5 amps, 230 volts, single pole, two way (ISI marked) complete all as specified & directed by Engineer-in-charge. |
| 112 | S&F vertical DBs TPN 4 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required,suitable for TP/FP MCCB as incomer with 01X MCCB 63A,10 KA, and with provision of SP/TP MCB\"s of required size as outgoing complete all as specified & directed by Engineer-in-charge. |
| 113 | S & F for MCB DB SPN 8 waydouble door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge. |
| 114 | Supply and fixing MCB\"s single pole and neutral 40 to63 Amps, 240 Volts,10 KA rapturing capacity \"C\" curve complete all as specified & directed by Engineer-in-charge. |
| 115 | Supply and fixing MCB\"s single pole 06 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity \"C\" curve complete all as specified & directed by Engineer-in-charge. |
| 116 | M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase)concealed conduitcircuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in pvc casing/capingincluding one run of PVC insulated multistrandedcopper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour including taking/down complete all as specified & directed by Engineer-in-charge.(Note :- Two runsof 6.00 Sqmm cable & one run of 6.00 Sqmm cable shall be paid as one unit length) |
| 117 | Supply and fixing of building security light fitting LED 35 Watt IP 66 IK 07 pressure dia cast aluminium housing with high efficient LED as lihjting souce and PC cover having TOP opening sepreate drive compartment etc and connecting complete all as specified & directed by Engineer-in-charge. |
| 118 | S& F in repair ofrepair bracket of GI pipe medium grade of 40mm dia ,1.2 meter in length clamps made of FI 40 mm x 6mm incl nuts, bolts & washers, painting complete all as specified & directed by Engineer-in-charge. |
| 119 | Supply and fixing of LED box type Integrated Batten 40 watt having Aluminum Extruded housing in white powder coated Finish with high translucent PC Cover, Elegant Design, IP 20 Protection. Dimensions of the Fitting Shall be Not less then 1200 MM ( Length) X40 MM ( Width ) X 63 MM ( Height ). Lumens output of the fitting shall be not less then 4400 lm, CCT 5700 – 6500K, buring hours 50,000 Surge Protector 4 KV, PF>= 0.95 , Separate detachable type Electronic constant current drivers for easy replacement and maintenance, THD < 10% , Necessary mounting arrangements .The fixture shall be suitable for wall mounting /suspension mounting as per site requirement . The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 /LM80 / Test Report as per CromptonCAT PART NO Shelter . CIS -305-40-57-SL-DP-NWHor equivalent in appx \"C\" list of makes |
| 120 | S & Fof LED tube light fitting 10 watt tube LED Neutral white in colour, 600 mm in length wall mounted LED batten,extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver,optic diffused typeENDURA LINER NEO including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required complete all as specified & directed by Engineer-in-charge. |
| 121 | Taking down ceiling fan/exhaust fan of any sweep sealing cable end dismanting blade and removing fan and blade to store complete all as specified and directed |
| 122 | M& L for painting of ceilingfan/Exhaust fan complete in situ with synthetic enamel paint by spraying including filling cavity with filler one coat after cleaning all dust etc compete all as specified and directed. |
| 123 | Fixingofceiling/exhaust fan after rewinding/servicing greasing change of bearing if reqd ,including making serviceable and noise free in all respect and connecting up including provn of cable from ceiling rose or connector to fan complete all as specified and directed. (Note :- Rate Quated by Contractor shall be inclusive for replacing all unsv item like quater pin ,nut bolt with check nut ,rubber real etc.) |
| 124 | M & L for rewinding of fan of any size with supper enameled copper wire of existing gauge including varnishing and drying complete reassembling & testing complete of 1200/1400 mm sweep complete all as specified & directed by Engineer-in-charge. |
| 125 | S&F Fan condenser, 2.5 Mfd, 240 volts for ceiling/exhaust fan including PVC clamp complete all as specified & directed by Engineer-in-charge. |
| 126 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified & directed by Engineer-in-charge. |
| 127 | M&L in repair ofbore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to 4.00 mm dia GI wire as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing workand 40mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified & directed by Engineer-in-charge. |
| 128 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium condutor of size 25 sq mm 3.5 core including taking down old existing cable complete all as specified & directed by Engineer-in-charge. |
| 129 | M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Enginner-in-charge . |
| 130 | Supply & laying 40 to 50 mm thick roughly hammer dressed Jodhpur stone patti cable cover 25 cm to 30cm wide and n.exc 60 cm long each laid dry abutting with each other with maximum gap between adjustment slabs n. exc 10 mm complete all as specifeid & directed by Enginner-in-charge . |
| 131 | S&F repair, 40 mm bore GI tubing \"light garde \"in treches on pole for protection of cables complete all as specified & directed by Engineer-in-charge. |
| 132 | M&L for road cutting and making good with PCC 1:3:6 type C-2(using 40 mm graded stone aggregate) complete all as specified & directed by Engineer-in-charge. |
| 133 | Taking out of old panel & Supply instal testing and commissioning of CPRI approved factory make LT panel boardoutdoor type pedelstal mounted dust proof, weather proof, vermin proof front side double door hinge type with locking arrangement rear side single door hinge type with locking arangement, sheet steel cubical type with slanting roof made out of 3.0mm thick CRCA sheet with powder coated finished suitable length and size. High conductivity 3 phase and neutral Aluminium bus bar of 300 Amps capacity duly mounted on pre cast insulators including earth work excavation, PCCfoundation necessary coping work,nuts and bolts and connecting electrically with suitable copper cable lug, cable glands etc complete all as specified and directed to accomodate the following items.Incoming:- (a) MCCB 100 amps 4 pole 16 KA - 1 Nos.(b) 3 phase LED ammeter & Voltmeter - 01 Set (d) LED type indication lamp for RYB.Outgoing:(a) MCCB 63 amps 4 pole 16 KA - 3 Nos. |
| 134 | M & L in repair ofbore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to 25X3 mm GI strip as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing workand 40mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed Engg-in-Charge. |
| 135 | Taking up carefully from trenches/walls/pillar GI/PVC water mains incl all fittings of following sizes:- |
| 136 | 20 mm bore. |
| 137 | 25 mm bore. |
| 138 | 50 mm bore. |
| 139 | 100 mm bore. |
| 140 | Supply and fix complete to walls / ceilings or laid in floors/surface steel water tubing galvanised medium grade with all fittings of following sizes:- |
| 141 | 20 mm bore. |
| 142 | 25 mm bore. |
| 143 | 50 mm bore. |
| 144 | 100 mm bore. |
| 145 | S&F in repairs globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for the follwing sizes with ISI marked and as per IS 14846 all as specified and directed by the Engineer-in-Charge. |
| 146 | 20 mm bore. |
| 147 | 25 mm bore. |
| 148 | 50 mm bore. |
| 149 | Taking up carefully from trenches/walls/pillar GI/CI/DI water mains incl all fittings with spigot and socket ends incl joint/rubber gaskets/lead wool/tyton joint of 150 mm bore complete all as specified and directed by Engineer-in-charge. |
| 150 | Supply and laying ductile iron pipe 150 mm bore with internal cement mortar lining and external zink pipeswith class of pipe K-9 complete all as specified and directed by Engineer-in-charge. |
| 151 | Supply and fix Sluice valve PN-1.6 with SS spindle and wedge nut ISI maked (IS-14846:2000) complete with iron wheel of following sizes:-Note:- Rate includes neccesary arrangements and cutting the pipe of required dimension with attachments for fitting the sluice valve. |
| 152 | 100 mm bore. |
| 153 | 150 mm bore. |
| 154 | Construction of valve chamber of size 90 x 90 x 90 cm (internal dimensions) with the following specifications :- |
| 155 | (i) 15cm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation concrete.(ii) PCC solid block masonry 200mm thick using grade C-5 block built in CM 1:6.(iii)Rendering 15mm thick in CM 1:4 finished even and fair.(iv)PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in coping.(v) 3mm thick MS sheet cover alongwith MS angle iron frame 40 x 40x6 mm duly embedded in coping concrete with necessary locking arrangement.(vi)Painting MS sheet cover and frame with two coats of synthetic enamel paint over a coat of red oxide primer.(NOTE : Excavation and earthwork shall deemed to inclusive in the rate quoted by the contractor. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail