| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-12-2025 | Fwd letter | Other | 16-01-2026 |
| 2 | 12-12-2025 | Arch Drawings | Other | 16-01-2026 |
| Sl. No. | Item Description |
| 1 | PHASE-I: |
| 2 | SCHEDULE \"A\" PART-I to SCHEDULE \"A\" PART-XV Note: Schedule \"A\" Part-I to Part-XV are prepriced by MES.Bidders shall insert their lump sum amount in green coloured field under Column 6 only. |
| 3 | Lump Sum price worked out by the contractor for(BUILDINGS & STRUCTURES), as listed in SCHEDULE \"A\" PART-I |
| 4 | Lump Sum price worked out by the contractor for \"Site Clearance/Area Development/Earth Work/Excavation\", as listed in Schedule \"A\" Part-II |
| 5 | Lump Sum price worked out by the contractor for \"Internal Water Supply\",as listed in Schedule \"A\" Part-III |
| 6 | Lump Sum price worked out by the contractor for \"Internal Electrification\", as listed in Schedule \"A\" Part-IV |
| 7 | Lump Sum price worked out by the contractor for \"External Water Supply\", as listed in Schedule \"A\" Part-V |
| 8 | Lumpsum price worked out by the contractor for \"External Electrification\",as listed in Schedule \"A\" Part-VI |
| 9 | Lump Sum price worked out by the contractor for \"Area Drainage\", as listed in Schedule \"A\" Part-VII |
| 10 | Lump Sum price worked out by the contractor for \"Sewage Disposal\", as listed in Schedule \"A\" Part-VIII |
| 11 | Lump Sum price worked out by the contractor for \"Road/Path/Culvert\", as listed in Schedule \"A\" Part-IX |
| 12 | Lump Sum price worked out by the contractor for \"AIR CONDITIONING\", as listed in Schedule \"A\" Part-X |
| 13 | Lump Sum price worked out by the contractor for \"LIGHTNING PROTECTION\", as listed in Schedule \"A\" Part-XI |
| 14 | Lump Sum price worked out by the contractor for \"R O PLANT AND SPECIAL iTEMS\", as listed in Schedule \"A\" Part-XII |
| 15 | Lump Sum price worked out by the contractor for \"WATER COOLER\", as listed in Schedule \"A\" Part-XIII |
| 16 | Lump Sum price worked out by the contractor for \"Rain Water Harvesting\", as listed in Schedule \"A\" Part-XIV |
| 17 | Lump Sum price worked out by the contractor for \"FIRE FIGHTING\", as listed in Schedule \"A\" Part-XV |
| 18 | Lump Sum price worked out by the contractor for \"DEMOLITION & DISMANTLING\", as listed in Schedule \"A\" Part-XV |
| 19 | SCHEDULE \"A\" PART-XIV: (MISCELLANEOUS ITEMS): |
| 20 | UPGRADATION & ADDITIONS/ALTERATIONS CIVIL WORKS: |
| 21 | INTERNAL WATER SUPPLY: |
| 22 | S&F angle stop valve 15mm dia., fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure pipes complete all as specified and as directed. |
| 23 | S&F health faucet 15mm dia., ABS rubbit cleaning system, with 1.25m long PVC flexible tube and ABS wall hook complete all as specified and as directed. |
| 24 | S&F bib taps 15mm dia., long body, cast copper alloy chromium planted fancy type with butterfly handle, screwed down for pipes complete all as specified and as directed. |
| 25 | INTERNAL ELECTRIFICATION: |
| 26 | Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor single core multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly complete all as specified and directed for One lightpoint controlled by one switch or One fan (Ceiling fan/Exhaust fan) point controlled by one switch or One 3 Pin socket outlet 5 Amps on independent board complete all as specified and as directed. |
| 27 | All as per item No.21 here-in-before but One 3 Pin socket outlet 5 Amps on the same board complete all as specified and directed. |
| 28 | All as per item No.21 here-in-before but One 3 pin socket outlet 15 Amps on independent board with 4 Sq.mm. FRLS PVC wire and one run of 4 Sq.mm. copper cable for earth continuity complete all as specified and directed. |
| 29 | M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 2.5 Sq.mm. cable and one run of 2.5 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed. |
| 30 | M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 6 Sq.mm. cable and one run of 6 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed.Note for Item Nos.24 & 25: Two runs of cable, one run of earth wire and one run of conduit will be measured as one unit. |
| 31 | S&F energy efficient LED tube light fitting with tube 9/10 Watts [minimum 100 lumens per watts], 240 Volts, 50 Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 Sq.mm. 3 core flexible copper conductor cable complete all as specified and directed. |
| 32 | S&F energy efficient LED tube light fitting with tube 20 Watts [minimum 100 lumens per watts] , 240 Volts, 50 Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 Sq.mm. 3 core flexible copper conductor cable complete all as specified and directed. |
| 33 | S&F LED security light fitting with tube 30 Watt [minimum 100 lumens per watts] new generation energy saving & environmental friendly long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre wired with 1.0 Sq.mm. copper conductor cable up to connector including 1.5m long GI tubing light grade of 32mm dia. bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc. complete all as specified and as directed. |
| 34 | S&F ceiling fans AC single phase 240 Volts of size 1200mm sweep with minimum delivery 210 cfm with service value, 6.00 BEE five star ratedbrushless direct current motor [BLDC] complete set with fixtures,metallic body complete all as specified and as directed. |
| 35 | S&F exhaust fan 250mm sweep 1350 RPM plastic body, complete with louvers suitable for operation on 240 Volts, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connection from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc. complete all as specified and as directed. |
| 36 | S&F exhaust fan 300mm sweep 1400 RPM metallic body (Heavy duty), complete with louvers suitable for operation on 240 Volts, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connection from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc. complete all as specified and as directed. |
| 37 | M&L earthing complete with GI plate electrode 60cmxx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metresdeep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth strip 25x4mm size by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 40 mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on completion all as specified and as directed.Note: Rate quoted deemed to be include GI protection pipe, funnel, excavation and earth work, in any type of soil with PCC type C1 in bed and pit complete all as specified and as directed. |
| 38 | EXTERNAL WATER SUPPLY: |
| 39 | Supply and lay Ductile iron pipes of size 100mm dia, class K7 with spigot and socket/double end flanged end of any length conforming to IS specification laid in trenches including tighten rubber gasket complete all as specified and directed.Note: The above rate is inclusive of the following points(i) Pipeline should be securely anchored at dead ends, tees, bends, tapers and valves to resist thrust arising from internal pressure. Anchors and thrust blocks should be designed in accordance with IS : 5330-1984.(ii) DI fittings, excavation and PCC as required sahll be measured and paid separately under relevant items. |
| 40 | Supply and fix 300mm dia Cast Iron Double flange non rising type sluice valve of following sizes as per IS 14846, PN 1.0 with hand wheel Operation flange Drilling as per IS 1538 including rubber gaskets, MS bolts, nuts, washers etc., as required complete all as specified and as directed. |
| 41 | M&L for brick masonary valve chamber of size 900mmx900mmx900mm( internal size) by providing PCC 1:2:8 tyepe D2 foundation 100 mm thickbrick work in CM 1:4 plastering 15mmthickin CM 1:4 internal surfaces completely and external surfaces completelyand external surfaces upto 150mm below GL, 75mm thick PCC 1:2:4 type B as in coping valve chamber cover made up of 40x40x5mm thick angle iron frame and 3.15 mm thick MS sheet cover completeexcavation and lockeing arrangement and handle including painting steel surfaces with two coats of enamel paint over a coatof red oxide primer includingdismantling the existing damaged valve chamber and removing debris away from the premises etc complete all as specified and as directed. |
| 42 | M&L for brick masonary valve chamber of size 1.2mx1.2mx1.2mm( internal size) by providing PCC 1:2:8 tyepe D2 foundation 100 mm thickbrick work in CM 1:4 plastering 15mmthickin CM 1:4 internal surfaces completely and external surfaces completelyand external surfaces upto 150mm below GL, 75mm thick PCC 1:2:4 type B as in coping valve chamber cover made up of 40x40x5mm thick angle iron frame and 3.15 mm thick MS sheet cover completeexcavation and lockeing arrangement and handle including painting steel surfaces with two coats of enamel paint over a coatof red oxide primer including dismantling the existing damaged valve chamber and removing debris away from the premises etc complete all as specified and as directed. |
| 43 | Cast iron bends (any radius and angles) tappers any type (straight, bend, increasing ,decreasing or double socket)Tee pieces single branch \"Y\" junction ,double branch ,cross (all socket orsocket spigot) collars, caps,caps & plugs for upto 300mm bore cast iron pipe with spigot and sockets end complete all as specified and as directed. |
| 44 | EXTERNAL ELECTRIFICATION: |
| 45 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 150 sqmm 3.5 core complete all as specified and as directed |
| 46 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 70 sqmm 3.5 core complete all as specified and as directed |
| 47 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 16 sqmm 4 core complete all as specified and as directed |
| 48 | Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size2.5 sq mm ,3 core, 1100 Volts grade passing through PVC Conduit/GI Pipe (from junction box to Street light/flood light/post top light/bollard light fitting |
| 49 | S&F LED street light fitting 35/36 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics by providingGI pipe medium grade 25 mm dia 1.5 Mtrin length with suitable size MS Clamp two nos made out of 25x3 mm FI, prewired and including connecting up with 3 core flexible copper conductor cable of 1.5 Sqmm complete with IP 65/66 protection complete all as specified and as directed by Engineer-in-Charge. |
| 50 | Material and labour for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique without damaging existing road/hard standing/walls and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed |
| 51 | Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosionesistant complete with driver, lamp and pole of suitable size not less than 1.5 mtr complete for garden light complete all as specified and as directed. |
| 52 | Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosionesistant complete with driver and lamp complete for gate light complete all as specified and as directed. |
| 53 | Supply , Fixingand Testing Powder coated Outdoor street light control box of size not less than 280 x 200 x 100 mm CRCA 2 mm thick IP 65 , halogen free and weather proof for outdoor installation , in and including suitable terminal TPN SMC Connectorfor three phaseCable Line ( IN & OUT) , MCB 10Amps SP\"C\" Series , canopyweather proof hinged doors, allenkey locking system and arrangements for fixing on Steel Poles with MS clamps of suitable shape and size with nut, bolts and washers as per site requirement complete all as specified and directed by Engr In Charge. |
| 54 | Supply , Fixingand Testing PVC body heavy duty Post top/bollard light control box ,in and including suitable terminal TPN SMC Connectorfor three phaseCable Line ( IN & OUT) , MCB 6Amps SP\"C\" Series , canopyweather proof hinged doors, allenkey locking system and arrangements for fixing on PCC/Steel Poles with MS clamps of suitable shape and size with nut, bolts and washersas per site requirement complete all as specified and directed by Engr In Charge (for gate light-2, garden light-12) |
| 55 | S&F Cable end jointing kit for indoor terminationheat shrink type suitable for 3.5core XLPE armoured aluminium conductor cable of 150 sqmm for complete with jointing material and accessories complete all as specified and directed by Engr In Charge |
| 56 | M&L for extention of busbar and insulator complete from existing VCB to proposed indoor VCB incl enclosure of bus couplar fitting jointing, nut and bolt etc all as specified and directed by Engr-in-Charge. |
| 57 | Materials & labour XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, 95 sqmm 3 core electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area complete all as specified and as directed. |
| 58 | Supply, Installation, testing and commissioning of new 11 KV, 630 Amp Outdoor type load break switch (LBS) complete unit, extensible 1 way load break switch stand alone floor mounted, internal copper bus bars not less than 2 mm thick having MS Sheet Steel enclosure suitable for IP55 as per IEC 62271-200, LBS should complete with all accessoriessuch as HRC fuse 11 KV- 3 NosManual Trip Push Button, terminal boots, Provision for receiving incoming/outgoing Cables through Bottom entry, including termination kit & glands, cable supports, all front cable terminations, mechanical indications for load break switch ON/OFF, Heater ON / OFF switch with filament type 200Watts space heater & thermostat, single phase switch with socket, Lamp for panel illumination with snap type door limit switch.Surge Arrester (9kV,10kA) including Control Wiring with appropriate size complete all as specified and directed with the following specifications as given :-Note : -(i)Factory inspection of load break switch and its testing shall be done by the representative of the Accepting Officer.(ii) The contractor shall produce drawing of load break switch (LBS) for according approval before the ordering of material to manufacturers. |
| 59 | Supply, install, testing and commisioning of copper wound Distribution Transformer stepdown Level 3, 11 KV/0.433KV, Three Phase complying with IS: 1180/IEC-76(Part-1) 2014 with latest amendments no.4, Indoor type double copper wound suitable for 50 Hz system of capacity 160 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side ,Vector Group Dyn-11. provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5% in step of 2.5%. Losses should be confined to the limits specified as follows: maximum allowable losses at full load (100 %) & Half Load (50 %) shall not be exceeded 513W & 1547W respectivly and as per GRIHA RATING, Percentage Impedance: 5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335. The transformer should have both side cable end box with neutral brought out complete and installation of transformer shall be carried out as per IS-10028 and comprising with the following standerd fittings/Technical specifications : - |
| 60 | (a) Lifting lug for transformer and tank.(b) Earthing terminal rating and diagram plate.(c) Air release device on main transformer tank.(d) Oil filling inlet pipe with plug.(e) Drain outlet pipe with brass gate valve.(f) Conservator tank with oil level indicator(g) Silica jel breather(i) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.(k) Type of connection Delta/Star(1) Type of cooling: Oil and Natural Air.(m) Vector group:DYN 11.(n) Temperature rise over an ambient of 50 °C maximum.(o) Air insulated Cable end box on both side for HT/LT cables of suitable size.(p) Provision of thermometer with pocket.(q) Provision of oil and winding temperature gauge.(r) Breather with silica gel with oil seal and first fill of silica gel(s) Rating diagram and terminal marking plate(t) Oil temp and winding temp indicator with maximum read pointer(u) Marselling Box |
| 61 | Supplying and fixing smart three phase four wire dual source prepaid energy meters BIS 15884 marked in existing meter board / floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 415 Volt accuracy class 1.0 alongwith parallel home display splitunit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition complete all as specified and as directed. |
| 62 | Automatic Power Factor CorrectionPanel LT (APFC) Indoor 12 way out put APFCrelay of capacity 50 KVAR with MD-XL Capacitor 6 steps ( 20 + 10 + 10+5 + 5) 3 phase, 415 V, 50 Hz, 4 wire busbarand aluminium busbar 300 amps for phases and neutral with totally enclosed system of capacity 1100 volts, 50 Hz, AC supply CPRI approved factory made fully compartmentalised with ventilating fan and made ouit of 2 mm thick CRCA sheet for load bearing and portions vermin proofwith powder coated including suitable angle iron frame work ,supports with suitable multi functional meter on incoming LED pilot lampsfor each phase ,push buttons ,CT coils ,VAF meter with selector switch in and including MCCB TP 125 Amps 25 KA as incomer - 1 No, control MCBs TP/SP 10 Amps to 63 Amps - 5 Nos , APFC controller, contactor of capacity 10 Amps to 63 Amps - 5 Nos and complete panel wiring complete all as specified and as directed. |
| 63 | Supply, Install, test and commissioning Outdoor type cubical panel board self supporting totally enclosed CPRI certified factory fabricated LT feeder pillar box, made out of 3.0mm thick CRCAsheet steelwith projected globe roof for rain water protection, dust and vermin proof, hingedfront opening double door shutters with neoprene rubber gasket, powder coated including danger plate, Provn of connection of GI earth strip 32mm x 6mm size - 02 Nos, ventilation louvers, bottom detatchable gland plate complete cubicle panel board suitable for3 phase 4 wire ,415 volts 50 HZ and 50mm x 50mm x 6 mm angle iron base frame,with locking arrangement, including provision of suitable size PCC M-15, type B1pedestal for mounting of panel boardfabrication of enclosure including base channel height outdoor type in and including the following Switch gear and necessaryincl control copper cable flexible multi strand FRLS, Busbar supports, SMC finger/conical supports for vertical & horizontal bus bars,Fasteners ,bolts.,nuts incl vertical & horizontal bus bars, inter connection bus bar , Incomer & out going bus bar of 500 Amp rating 3 phase and neutral incl internal wiring and connections frombus bar to switch gear,testing on completion and commissioning complete all as specified and as directed internal wiring and connections frombus bar to switch gear,testing on completion and commissioning complete all as specified and as directed. :-(proposed to install near by the site) |
| 64 | (a) MCCB, 4 pole, 250 Amps 35 KA -01 No(I/C)(b) 3 Pole MCCB 100-125 Amp 50 Hz, 415 V with rupturing capacity 35 KA. -03 Nos (For Loadline DB 2 Nos + 1 No spare ) (c) 3 Pole MCCB 63 Amp, 50 Hz, 415 V with thermal based release rupturing capacity 25 KA -03 Nos(O/G for street light and garden light = 1, for APFC control=1 +1 No spare) (d) Timer switch 415 volts,three phase of 20 Amp rating with power contactor fitted inside the panel =2 (one for streetlight right wing one for left wing) (e) LED Phase Indication Lamp-03 (RYB)(f) Multi functioning meter digitalType 0-500 Volt -01 No (g)Resin cast current Transformer =3(h) Selector switch 6A,4 Posn.=3 |
| 65 | Material and labour for Earthing complete with using galvanised steel earth plate electrode of size 600mm x 600mm x6 mm thick buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) , with top edge of the plate at a depth not less than 1.5m below ground level connected with and incl galvanised iron strip 32 x 6 mm as earthing lead including 40 mm dia GI pipe light grade by means of nuts bolts, washers and necessary earth work in any type of soil PCC (1:3:6) type C1 chamber and RCC(1:2:4) type B-1cover with handle and watering pipe 20 mm dia GI medium grade with funnel complete with mesh , refiling with black cotton soil, alternate 5 layersof charcoal (250 Kg) &salt crystal (200Kg )andtop two inches layerswithBack fillingcompound(100 Kg), all as specified. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, 50mm thick RCC cover, reinforced with 8mm dia CTD bars at 100mm C/C on both directions, removal of surplus soil , site clearance etc. (ii) GI earth strip , GI tubing light grade upto 7.5m deemed to be included the rate quoted by the contractor.(iii) Beyond 7.5 M the GI earth strip & GI pipe light grade 40 mm dia shall be measured and paid separetely under the respective item of the schedule (iv) Quotated rate include testing after completion from test point and the desired earth resistance shall be not more than 5 ohm .If the desired result is not obtainedthe earthing will be re done by the contractor at no extra cost. (For Transformer -4, LBS -4, LT Panel - 2, Lighting protection- 6) |
| 66 | Material and labour for Earthing complete with using galvanised steel earth plate electrode of size 600mm x 600mm x6 mm thick buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate at a depth not less than 1.5m below ground level connected with and incl galvanised GI wire 4mm dia including 25 mm dia GI pipe light grade by means of nuts bolts, washers and necessary earth work in any type of soil PCC (1:3:6) type C1 chamber and RCC(1:2:4) type B-1cover with handle and watering pipe 20 mm dia medium grade with funnel complete with mesh , refiling with black cotton soil, alternate 5 layersof charcoal (250 Kg) &salt crystal (200Kg )andtop two inches layerswithBack fillingcompound(100 Kg), all as specified. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, 50mm thick RCC cover, reinforced with 8mm dia CTD bars at 100mm C/C on both directions, reinforcement removal of surplus soil , site clearance etc. (ii) GI earth strip , GI tubing light grade upto 7.5m deemed to be included the rate quoted by the contractor.(iii) Beyond 7.5 M the GI earth strip & GI pipe light grade 15 mm dia shall be measured and paid separetely under the respective item of the schedule (iv) Quotated rate include testing after completion from test point and the desired earth resistance shall be not more than 5 ohm .If the desired result is not obtainedthe earthing will be re done by the contractor at no extra cost. (For Street Light) |
| 67 | Taking downserviceable HT cable of size 185 sqmm 3 core and cable cover of any size/ typefrom site and kept in safe custody for relaying in new route out side of KV complex play ground area, the cost deemed to be included in the quoted rate forexcavation, removal of cable and cable cover, cutting old existing cables, disconnecting cable joints and also taking up loop from the under ground carefullyand making good the disturbed surfaces in all respect where ever required as per site requirement complete all as specified and as directed. (ATH HT UG cable and NORA HT UG cable) |
| 68 | Supply,laying XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of size 185 sqmm 3 core, connecting with proper size Aluminium lugs, glands whereever necessary near ATC LT Panels to Bus bar chamber at ATC all as per site requirement , testingcomplete all as specified and directed. Make:- havells, Polycab, KEI,Gloster |
| 69 | Relaying of serviceable LT cable of any size as obtained from site complete all as specified and as directed. |
| 70 | Relaying of serviceable bricksas obtained from site complete all as specified and as directed. |
| 71 | Taking downserviceable LT cable and cable cover of any size/ typefrom site and kept in safe custody for relaying in new route out side of KV complex play ground area, the cost deemed to be included in the quoted rate forexcavation,removal of cable and cable cover, cutting old existing cables, disconnecting cable joints and also taking up loop from the under ground carefullyand making good the disturbed surfaces in all respect where ever required as per site requirement complete all as specified and as directed. |
| 72 | Supply,laying XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of size 120 sqmm 3.5 core, connecting with proper size Aluminium lugs, glands whereever necessary near ATC LT Panels to Bus bar chamber at ATC all as per site requirement , testingcomplete all as specified and directed. Make:- havells, Polycab, KEI,Gloster |
| 73 | Relaying of serviceable HT cable of any size as obtained from site complete all as specified and as directed. |
| 74 | Relaying of serviceable HT cable coversas obtained from site complete all as specified and as directed. |
| 75 | Supply and fix cable jointing kit for HT under ground cable for straight through joint heat shrink type and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 185 sqmm, complete all as specified and as directed. Make:- 3M, Denson, Raychem. (For Rerouting Cable) |
| 76 | Supply and fix cable jointing kit for HT end joint heat shrink Indoor type type and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 185 sqmm, complete all as specified and as directed.Make:- 3M, Denson, Raychem. (For Rerouting Cable) |
| 77 | Supply and fix cable jointing kit for LT under ground cable for cable for straight through heat shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 120 sqmm complete all as specified and as directed. |
| 78 | Supply and fix cable jointing kit for LT under ground cable for end joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 120 sqmm, Indoor type complete all as specified and as directed. Make:- 3M, Denson, Raychem. |
| 79 | Supply, fabricate, install and testing outdoor type LT bus bar chamber box of size 800x600x400mm from CPRI certified panel manufacturersincluding provision of dimrail for mounting 1 No of MCCB incl S&FMCCB 250 Amp 4 Pole, 415 V, Adjustable type, with breaking capacity 36 KA, hinged door with allen key locking arrangement made out of 3mm thick CRCA sheet steel powder coated with front and rear opening slanting cannopy on roof and mild steel channels base frame angles of 50x50x5mm in and including TPN aluminium bus bar of 250A capacity for looping and branch connection, the bus bar placed on suitable capacity insulators including danger notice plate on both side, neoprene rubber gasket to make it completely dust and vermin proof the same will be fixed in ground with necessary PCC foundation made by (1:2:4) type B1 complete all as specified and directedby Engr-in-charge.Note - (1) The cost deemed to be included in the quoted rate for reconnecting Old existing cables to boxes carefully using a suitable glands and also taking up loop from the under ground and making good in all respect where ever required as per site requirement complete all as specified and as directed. |
| 80 | Material and labour for cutting of bituminous road / floor for laying ofU/G cables not exceeding 1.5 meter wide and not exceeding 1.5meterdeep including refilling / with material and, watering well ramming / compacting and making good with PCC 1:3:6, type M-10 100mm thick complete all as specified anddirected by Eing-in-charge. Note :-PCCshall bemeasuredseparately. |
| 81 | R O PLANT |
| 82 | Supply and fix Reverse Osmosis Plant stainless steel, 240 volts, Full automatic, 60-65% to 95% purity level, ofout put capacity of 60 Litres per hour with RO+TDS technology including inlet valve set, spanner for bowl, inlet and reject pipe and all connected items, Auto shut off and start syetem, overflow protection complete all as specified and as directed. |
| 83 | WATER COOLER |
| 84 | Supply & Installation Voltage Stabilizer for automatic operation single phase natural air cooled indoor type anddesigned for input variation between 100 Volt to 290 volt with output voltage stabilized at 230 volt with accuracy +/- 2.5% and capacity 2 KVA complete all as specified and as directed. Make: V Guard VE 400 or equivalent in Microtek/Voltamp/Vinitec |
| 85 | LIGHTENING PROTECTION |
| 86 | Supply and fix Epoxy insulator of size 25 mm X 3 mm for fixing of aluminium strip on wall/ roof/ pole etc complete all as specified and as directed. |
| 87 | Material and labour for Earthing complete with using galvanised steel earth plate electrode of size 600mm x 600mm x6 mm thick buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate at a depth not less than 1.5m below ground level connected with and incl galvanised iron strip 32 x 6 mm including 40 mm dia GI pipe light grade by means of nuts bolts, washers and necessary earth work in any type of soil PCC (1:3:6) type C1 chamber and RCC(1:2:4)type B-1cover and watering pipe 20 mm dia medium grade with funnel complete with mesh , refiling with black cotton soil all as specified. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, 50mm thick RCC cover, reinforced with 8mm dia CTD bars at 100mm C/C on both directions, reinforcement removal of surplus soil , site clearance etc. (ii) GI earth strip , GI tubing light grade upto 7.5m deemed to be included the rate quoted by the contractor.(iii) Beyond 7.5 M the GI earth strip & GI pipe light grade 40 mm dia shall be measured and paid separetely under the respective item of the schedule (iv) Quotated rate include testing after completion from test point and the desired earth resistance shall be not more than 2 ohm .If the desired result is not obtainedthe earthing will be re done by the contractor at no extra cost. |
| 88 | AIR CONDITIONING: |
| 89 | Supply and install 5 KVA wall mounted voltage stabilizer for automatic operation single phase nautrally air cooled indoor type and designed for input variation between 130 Volt to 280 Volt with output voltage stabilised at 230 Volt with accuracy +2.5% including provision of volt meter for monitoring input and output voltage and bypass cut out switch complete all as specified and directed.Make: V-Guard/Purevolt/Voltas/Krykard |
| 90 | Supply and fix plug and socket SPN enclosure with a two pin and earth complete with one MCB SP 32 Amps \"C\" curve 10 KA breaking capacity of 240 Volts complete all as specified and directed. |
| 91 | S &F Copper tube with insulation for suction and discharge line combined (same size as for the AC installed ) for connection between indoor and outdoor unit (beyound 3 mtr) complete all as specified and as directed. |
| 92 | S & F 4 core 4 Sq mm muti stranded copper conductor cable for connection between indoor and outdoor unit (beyound 3 mtr) complete all as specified and as directed. |
| 93 | Supply & Installation Voltage Stabilizer for automatic operation single phase natural air cooled indoor type anddesigned for input variation between 90 Volt to 300 volt with output voltage stabilized at 230 volt with accuracy +/- 2.5% and capacity 5 KVA or 15 Ampere complete all as specified and as directed. Make: V Guard VE 500 or equivalent in Microtek/Voltamp/Vinitec |
| 94 | FIRE FIGHTING: |
| 95 | Material and labour for Earthing complete with using galvanised steel earth plate electrode of size 600mm x 600mm x6 mm thick buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) , with top edge of the plate at a depth not less than 1.5m below ground level connected with and incl galvanised iron strip 32 x 6 mm as earthing lead including 25 mm dia GI pipe light grade by means of nuts bolts, washers and necessary earth work in any type of soil PCC (1:3:6) type C1 chamber and RCC(1:2:4) type B-1cover with handle and watering pipe 20 mm dia medium grade with funnel complete with mesh , refiling with black cotton soil, alternate 5 layers of charcoal (250 Kg) &salt crystal (200Kg )andtop two inches layerswithBack fillingcompound(100 Kg), all as specified. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, 50mm thick RCC cover, reinforced with 8mm dia CTD bars at 100mm C/C on both directions, reinforcement removal of surplus soil , site clearance etc. (ii) GI earth strip , GI tubing light grade upto 7.5m deemed to be included the rate quoted by the contractor.(iii) Beyond 7.5 M the GI earth strip & GI pipe light grade 40 mm dia shall be measured and paid separetely under the respective item of the schedule |
| 96 | (iv) Quotated rate include testing after completion from test point and the desired earth resistance shall be not more than 5 ohm .If the desired result is not obtainedthe earthing will be re done by the contractor at no extra cost. |
| 97 | Supply and installation of fire brigade connection consisting of 02Nos of 63mm dia instantaneous male coupling with built in check valve, sluice valve and non return value complete all as specified and directed. |
| 98 | M&L for supply and laying control cable of size 12 core x 1.5 sqmm, 1100 V grade, copper conductor, PVC insulated, armoured, and overall sheathed, laid on wall/surface using heavy-duty MS saddles and spacers at regular intervals not exceeding 0.6m, fixed with suitable rawl plugs and screws, including termination at both ends with compression type brass glands and crimping type copper lugs, testing on completion, complete all as specified and directed. |
| 99 | Supply, installation, testing, and commissioning of floor/wall-mounted automatic booster pump control panel fabricated from 18 SWG CRCA sheet, powder coated, dust and vermin-proof, conforming to IP-54 protection, suitable for operation of 2 Nos. three-phase booster pumps of 450 LPM discharge at 30m head (equivalent to 3.5 kg/cm²). Panel shall be suitable for 415V, 3-phase, 50Hz AC supply system. The panel shall be equipped with 1 No. 63A, 4-pole MCCB (breaking capacity 25kA) as incomer with rotary handle, door interlock and shrouding. Outgoing feeders shall comprise 2 Nos. 32A, 3-pole MCBs with Direct-On-Line (DOL) Starters consisting of contactors (AC3 rated), thermal overload relays (adjustable), and control fuses. Panel shall also include voltmeter (0-500V) with selector switch, ammeter (0–50A) with CTs and selector switch, R-Y-B phase indication lamps, pump run/trip indication lamps, Auto/Manual selector switches for each pump, control transformer for 230V AC control supply, phase failure relay, and interlocking for remote and local operation.Pressure |
| 100 | switches shall be connected to control the auto operation based on delivery pressure, and panel shall support remote override control via Remote Control Panel. All wiring shall be done using color-coded FRLS copper wires with numbered ferrules. Cable alleys, gland plates, copper earthing busbar with terminals, and suitable terminal blocks for control and power cables shall be provided. All components shall be mounted on MS painted backplate with proper spacing and labeling. Testing, commissioning, insulation resistance test, and full load run test shall be conducted in presence of Engineer-in-Charge complete all as specified and as directed. |
| 101 | Supply and installation of wall-mounted Remote Control Panel for booster pump operation, fabricated from 18 SWG CRCA sheet, duly powder coated, IP-54 rated, with lockable hinged door. The panel shall be suitable for remote operation and status indication of 2 Nos. booster pumps. The panel shall include 2 sets of ON/OFF push buttons (green/red), Auto/Manual selector switches, run/fault LED indication lamps, 1 No. voltmeter (0–500V) with selector switch, audible buzzer with mute push button, and interlocking for manual override. Panel shall interface with booster pump panel via multicore armoured copper control cable. Remote commands in Manual Mode shall override Auto Mode commands from pressure switches. Panel shall include control relays, terminal blocks, internal control wiring using FRLS copper wires with ferrules, and necessary labeling for all switches and indicators. Panel shall be factory wired and tested for all control logics, and commissioned at site with complete demonstration complete all as specified and as directed. |
| 102 | Supply of 12V 7Amp Batteries with rechargeable complete all as specified and directed. |
| 103 | Supply and install Water flow switch complete all as specified and directed. |
| 104 | Supply, laying, and fixing of 2 Core x 1.5 sqmm FRLS copper conductor cable (ISI marked) conforming to IS:1554 Part I, drawn through heavy-duty FRLS ISI-marked PVC conduit of not less than 20 mm dia, complete with all accessories such as bends, junction boxes, inspection boxes, conduit fittings, and concealed in walls/floors/ceilings including cutting, fixing, clamping, making good to the original finish and testing as required complete all as specified and as directed. |
| 105 | Supply and fixing fire instruction board of size 18 inch x 24 inch made from 3mm thick PVC / ACP sheet, duly printed in English and Hindi with clear fire safety instructions titled “IN CASE OF FIRE / IF FIRE OCCURS,” including emergency contact numbers, evacuation procedures, pictograms, and assembly point information. The board shall have photoluminescent text and symbols, be mounted on wall at eye level using brass screws and PVC sleeves, complete all as specified and directed by Engineer-in-Charge. |
| 106 | Supply and fixing of fire safety signage boards made of PVC/UPVC, 12”x6” size (or as directed), marked on both sides using reflective or photoluminescent tape/paint, including wording for fire hydrant, fire extinguisher, fire exit, hose reel, manual call point, etc., and suitable hanging/wall fixing arrangements, complete all as specified and directed. |
| 107 | Supply and fix 6 Kg Fire Extinguisher Dry Chemical Powder (ABC) Type complete all as specified and as directed. |
| 108 | Supply and fix 3 Kg Fire Extinguisher CO2 Type (light weight squeeze grip type) complete all as specified and as directed. |
| 109 | Supply and fix 9 Ltr Fire Extinguisher water stored pressure type complete all as specified and as directed. |
| 110 | Supply and fix 4 Kg Fire Extinguishers clean Agent Type complete all as specified and as directed. |
| 111 | Supply and fix 9 Kg Fire Extinguisher Dry Chemical Powder (ABC) Type complete all as specified and as directed. |
| 112 | Supply and fix 9 Ltr Mechanical Foam Extinguisher (stored pressure type) complete all as specified and as directed. |
| 113 | Supply andfix fire bucket (Dry sand) complete all as specified and as directed. |
| 114 | Supply and fix bucket stand for 02Nos complete all as specified and as directed. |
| 115 | SEWAGE DISPOSAL: |
| 116 | RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RR Masonary wall RCC M-30 Design Mix inBaffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc.,complete for 150 Users complete all as specified and as directed. |
| 117 | Soakage wells excavation, in any type of soil, foundation in PCC 1:4:8, walls of honey combed masonry with top ringincluding intercepting chamber and screen chamber made of Brick masonary in CM 1:4,cover slab / SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats, complete of size 4.3m Dia x3.00 Deep. complete all as specified and as directed. |
| 118 | LIGHTNING PROTECTION: |
| 119 | S&F epoxy insulator of suitable size for fixing of aluminium strip on wall/roof/pole etc. complete all as specified and as directed. |
| 120 | Material and labour for Earthing complete with using galvanised steel earth plate electrode of size 600mm x 600mm x6 mm thick buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) , with top edge of the plate at a depth not less than 1.5m below ground level connected with and incl galvanised iron strip 32 x 6 mm as earthing lead including 25 mm dia GI pipe light grade by means of nuts bolts, washers and necessary earth work in any type of soil PCC (1:3:6) type C1 chamber and RCC(1:2:4) type B-1cover with handle and watering pipe 20 mm dia medium grade with funnel complete with mesh , refiling with black cotton soil, alternate 5 layersof charcoal (250 Kg) &salt crystal (200Kg )andtop two inches layerswithBack fillingcompound(100 Kg), all as specified. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, RCC cover, reinforcement removal of surplus soil , site clearance etc. (ii) GI earth strip , GI tubing light grade upto 7.5m deemed to be included the rate quoted by the contractor.(iii) Beyond 7.5 M the GI earth strip & GI pipe light grade 15 mm dia shall be measured and paid separetely under the respective item of the schedule (iv) Quotated rate include testing after completion from test point and the desired earth resistance shall be not more than 2 ohm .If the desired result is not obtainedthe earthing will be re done by the contractor at no extra cost. |
| 121 | ARBORICULTURE |
| 122 | M&L for Poeta soil (garden soil) mixed with requisite quantity of pesticides and fertilizers while filling (stack measurements shall be considered for payment) |
| 123 | M&L for dry gober manure mixed with requisite quantity of pesticides and filled along with the garden soil in alternate layers (stack measurements shall be considered for payment) |
| 124 | Supply and planting dry American/ Korean grass in mud patches and watering all as specified and as directed. |
| 125 | Supply and Planting of hedges like Aakalita Aspar/Duranta varigated by digging in trenches of size 300mm wide and 300mm deep and filling soil obtained from same location upto 200mm height and balance 100mm depth filled with garden soil and manure mixed in the required proportion and planting hedges of height 300mm above GL and removal of soil, debris, weeds to a distance exc 250m and n.exc 500m and watering etc complete incl 3 years maintenance complete all as specified and as directed by the Engineer-in-Charge. |
| 126 | Supply and Planting Semi studded plants like Golden Tum/Mananta varieties as per argus/mery aglonima draft varieties by digging in trenches of size 300mm wide and 300mm deep and filling garden soil and manure mixed in the required proportionand watering etc incl 3 month maintenance complete all as specified and as directed by the Engineer-in-Charge. |
| 127 | S&F 20mm bore outer dia 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings or laid in trench or in floors etc. |
| 128 | S& F 20mm dia.PP-R Gate valves (brass insert) as perrequirement of the site |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |