| Sl. No. | Item Description |
| 1 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth; for foundation etc or for shafts, wells, cesspits, manhole, pier holes, etc n.exc 10 Sqm on plan andn.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | M&L for PCC (1:4:8),type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed. |
| 3 | M&L for brick work with sub class B bricks(using old size burnt bricks) straight or curved on plan exceeding 6 m mean radius, built in Cement Mortar (1:6) complete all as specified and as directed. |
| 4 | M&L brick work with sub class B bricks(using old size burnt bricks) straight or curved on plan to any radius in half brick thick walls built in CM (1:4)complete all as specified and as directed. |
| 5 | M & L for RCC (Nominal Mix) (1:1.5:3) type B-1 (using 20mm graded crushed stone aggregate) as inFoundations, including rafts,footings, foundation beams;plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and massconcrete complete all as specified and as directed |
| 6 | M&L for RCC (Nominal Mix) (1:1.5:3) type B-1 (using 20mm graded crushed stone agg) as in beams, cantilvers, bressummers, lintels over 1.5m span complete all as specified and as directed |
| 7 | M & L forRCC (Nominal Mix) (1:1.5:3) type B-1 (using 20mm graded crushed stone agg) as in columns, pillars, piers, posts and struts complete all as specified and as directed |
| 8 | M & L for RCC (1:1.5:3) type B-1, Nominal Mix (using 20 mm graded granite stone aggregate) as chajjas complete all as specified and directed. |
| 9 | M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 10 | M&L for mild steel TMT bars 6 to 8mm dia and over cut to length, bent to shape required, including cranking, bendingand binding with and including mild steel wire (annealed) not less than 0.9mm dia (annealed) for stirrups/binders complete all as specified and as directed |
| 11 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 12 | Use and waste of formwork to sides and soffits of floors or roof beams, beams haunchings, girders,bressummers lintels, cantilevers, shelves including supports overhangs etc also splays between floors and beams complete all as specified and directed. |
| 13 | Use and waste of formwork to sides of pillars posts, struts, piers, columns and stanchions finished the suface rough. |
| 14 | Use and waste for formwork to chullah hoods, cha jjas, troughs and similar items in cluding edge complete all as specified and directed. |
| 15 | S & F of steel work as in tubular trusses/framed work including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS – 1161 – 1979 grade St – 240 including one shop coat of zinc chromate primer paint complete all as specified and as directed. |
| 16 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming Fe-410-W(Gde-E-250) quality-A and painted one shop coat of zinc chromate primer paint (including preparation of surface) at contractors workshop before fabrication complete all as specified and as directed. |
| 17 | S & F MS Plates (plain or chequered) channels,squarecutor notched (ordinaryand countersunk) forming holes, without any attachment conforming to Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed. |
| 18 | S & F MS Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exc 15cmn exc 22.5cm long dia neck 16 to 20mm complete all as specified and as directed. |
| 19 | M&L for preparation of newsurfaces of steel and iron work of any description over 10 cm width or girth not otherwise described andapplying two coats of synthetic enamel paint over a coat of red oxide primer on new surfaces in any tint complete all as specified and as directed. |
| 20 | M & L plain cement concrete (1:2:4), type B-1 (using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed. |
| 21 | M&L for rendering 10 mm thick plaster in CM (1:6) on fair faces of brick or concrete work finished the surface even and smooth without using extra cement complete all as specified and as directed. |
| 22 | M & L rendering 15mm thick on cement mortar (1:4) brick or concrete work using water proofing compound @3% by wt of cement for finished the surface even and smooth without using extra cement complete all as specified and as directed. Note:WPC will be measured and paid separately. |
| 23 | Supply only Intergral water proofing compound complete all as specified and as directed. |
| 24 | M&L for one coats of white wash on old decorated wall surfaces including removing of grass, creepes, vegitation growth etc complete all as specified and as directed. |
| 25 | M&L 40 mm thick PCC (1:2:4) type B-0 (using 12.5 mm graded stone agg) as damp proof course to horizontal or vertical surfaces including necessary form works, applying evenly a coat of blown type bitumen at 1.50 kg per sqm and blinding with clean dry sand @ 0.05 cum per sqm including 150 micron thick polythene film laid on a coat of bitumen primer @ 0.30 to 0.50 kg per sqm complete all as specified and as directed. |
| 26 | M&L for hardcore (broken stone/boulders) of gauge exc 63mm but n.exc 100mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammmed to a true surface etc complete all as specified & directed by Engr-in-Charge. |
| 27 | M&L for 75mm thick PCC (1:4:8), type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed. |
| 28 | M&L for 25mm thick PCC (1:2:4),type B-1 (using 20mm graded stone aggregate) as in sub base of flooring finished even and fair without using extra cement complete all as specified and as directed. |
| 29 | M&L for 75 mm thick PCC (1:3:6) type C-2 , (using 40 mm graded stone aggregate) as in plinth protection laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide that area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and as directed. |
| 30 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws asspecified complete all as specified and as directed. |
| 31 | S&FPre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed. |
| 32 | S & F for4 mm thick of size 600x600mmHSPC (high pressure Steam Cured) non asbestos fibre cement reinforced multipurpose board, pre-painted self embossed, textured designer boardE-Board Classic fixed or laid/inserted to timber/ GI frame work with screws to be fixed in ceiling flat or sloping and Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre both ways, size of grid 605 x 605mm fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size complete all as specified and as directed. |
| 33 | S & F guard bars to windows, plain, let in and fixed independently in steel frames including welding etc guard bars and similar work confirming to Fe-290 grade E-165 for wire cloth and sheet glass complete all as specified and as directed. |
| 34 | S&F butt hinges medium grade cold rolled mild steel and fixed size of hinges 100 mm long size complete all as specified and as directed. |
| 35 | S&F Aluminium handle cast type anodised 150 mm long complete all as specified and as directed. |
| 36 | S&F butt hinges medium grade cold rolled mild steel and fixed size of hinges 75 mm long size complete all as specified and as directed. |
| 37 | S&F Aluminium anodised barrel tower bolt of extruded section and fixed 100 mm long complete all as specified and as directed. |
| 38 | S&F Aluminium handle cast type anodised 125 mm long complete all as specified and as directed. |
| 39 | S&F Aluminium anodised barrel tower bolt of extruded section and fixed 200 mm long complete all as specified and as directed. |
| 40 | M & L for factory made 30mm thick 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed. |
| 41 | S & F stainless steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed. |
| 42 | S&F Sheet glass 4.8mm thick, ordinary quality black colour and glazing with oil putty in squares exceeding 0.5 sqm in each pane complete all as specified and as directed. |
| 43 | S & F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed. |
| 44 | M&L for preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink wood primer complete all as specified and directed. |
| 45 | M&L for applying two coats of oil bound distemper over a coat of primer on new plastered surfaces of walls including preparation of newsurface complete all as specified and as directed. |
| 46 | M & L preparing the new surfaces of wall plastered and applying two coat of exterior weather paint over one coat of primer of wall surface complete all as specified and as directed. |
| 47 | S&F rotational moulded polyethylene 1000 Ltrs Capacity water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I with and including ball brass valve, with polythelene float and fly nut complete suitable for iron pipe of 20 mm diacomplete all as specified and as directed. |
| 48 | S&F tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 20 mm bore complete all as specified and directed. |
| 49 | S&F tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 15 mm bore complete all as specified and directed. |
| 50 | S&FBrass CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixed etc complete all as specified and directed. |
| 51 | S&F CP Health Faucet 15mm bore fancy type with suitable flexible pipe as per site requirement incl CP nipple with socket complete all as specified and as directed. |
| 52 | M&L for cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting not exc 10 cm girthcomplete all as specified and as directed. |
| 53 | S&F vitreous china wash basin, size 550 x 400mm white including brackets,waste coupling & pipe of 32mm dia, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and as directed. |
| 54 | M&L for Viterous china ware wash down water closet pan (EWC), pedestal pattern coloured including plastic WC seat black closed pattern with flat bottom and cover and mild steel chromium plated of aluminised hinging device, complete fiting complete all as specified and as directed. |
| 55 | S&F in repair PVC low level flushing cistern 10 ltr capacity syphonic action type white body with MS bracket,inlet ball valve, floathandle and flush pipe (for EWC or WC)complete all as specified and as directed. |
| 56 | S&F 15mm borebib tap cast copper alloy fancy type with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. |
| 57 | S&F 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed. |
| 58 | S&F 15mm diastop valves (Concealed type) Fancy type and CP screwed down high pressure with crutch or butterfly handle screwed both shanks and fly-nuts screwed for iron pipe and fixedcomplete all as specified and as directed. |
| 59 | S&F for 15mm diapipe stop valves Fancy type and CP screwed down high pressure with crutch or butterfly handle screwed both shanks and fly-nuts screwed for iron pipe or Union and fixedcomplete all as specified and directed. |
| 60 | S&F for PVC Connection pipe 15mm dia and 45cm long size with brass checknuts and washers of length 450 mm complete all as specified and as directed. |
| 61 | S & Fbrass CP Shower rose 125mm in size with or without swivel joints any size incl fixing to steel pipe or union complete all as specified and as directed. |
| 62 | S & F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed. |
| 63 | S&F CP towel rail 600mm long with brackets, aluminium anodised 20mm dia complete all as specified and as directed. |
| 64 | M&L for Granite (of any type) tiles 18-20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigmentto match the shade of granite stone including grinding and polishing with nosing laid over and including 10 mm thick screed bed in CM (1:4) as in platform complete all as specified and as directed. |
| 65 | S&F PVC (SWR) 110mm dia single socketed in any length with rubber ring joints laid in trenches or in floor complete all as specified and as directed. |
| 66 | M & Lfor 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or laid in floors complete all as specified and as directed. |
| 67 | S&F PVC (SWR) 110mm dia bends in any radius complete all as specified and as directed. |
| 68 | S&F PVC (SWR) 75mm dia bends in any radius complete all as specified and as directed. |
| 69 | S&F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening complete all as specified and as directed. |
| 70 | S&FFactory made solid panel PVC door shutter 30mm thick (stile) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C\" channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bbottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame wedded/ sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified and as directed. |
| 71 | M&L for precast cement concrete type B-1, (1:2:4)(Using 20 mm graded stone aggregate) as in cover slabs, manhole cover, chamber cover and drainge cover set in cement mortar 1:6 including necessary formwok complete all as specified and directed. |
| 72 | M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm,in floors laid over and including 15mm thick screed bedin CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tilescomplete all as specified and as directed. |
| 73 | All as per Item No. 72.00 (here-in-before) but on vertical surfaces such as skirting, dado, risers to stepsover and including 10 mm thick bedding layer in CM (1:4). |
| 74 | M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm,in floors laid over and including 15mm thick screed bedin CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tilesincluding dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 75 | Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified ans as directed. |
| 76 | Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified ans as directed. |
| 77 | M & L for DWCPE (SN8) 150mm (ID) diameter pipes laid in trenches complete all as specified and as directed. |
| 78 | M & L forFramed work such as grills, grating, etc.. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railing; framework of water tank and similar work conforming to Fe.290 Gde-E-165 complete all as specified and as directed. |
| 79 | M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular),area of each tiles exceeding0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in whitecement mixed with pigment to match shade of tiles,laid over and including 15 mm thick screed bed in CM (1:6)complete all as specified and directed. |
| 80 | All per item No.79.00 (here-in-before) but on vertical surfaces such as skirting , dado risers to stepsover and including 10 mm thick bedding layer in CM (1:4). |
| 81 | M&L for Machine cut kota stone slab flooring 20-25mm thicklaid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete laid over 20mm thick screed bed in CM (1:3) complete all as specified and as directed. |
| 82 | M&L providing kota stone slab 20 to 25mm thick machine cut in riser of steps, skirting ,dado and piller laid over 10mm thick screed bed in CM (1:3) complete all as specified and as directed. |
| 83 | S&F5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification complete all as specified and as directed. |
| 84 | S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications complete all as specified and as directed. |
| 85 | M&L for second class hardwood plain fillets exc 0.06 sqcm and notexc. 13sqcm, square or rectangular in section, wrought, secured with nails or brads. |
| 86 | M&L for second class hardwood as in scantlings clean sawn timberfixed including dismantling old timber scantlings 40 sqcm and over in section, in unframed work any position complete all as specified and as directed. |
| 87 | M&L for Glazed ceramic coloured tiles in vertical surface 300 mm X 200 mm / 350 x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tileover and including baking coat of 10 mm thick in Cement Mortar (1:4),complete all as specified and as directed. |
| 88 | M&L for Glazed ceramic coloured tiles in vertical surface 300 mm X 200 mm / 350 x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tileover and including baking coat of 10 mm thick in Cement Mortar (1:4),including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 89 | Surface excavation n.exc 15cm deep and getting out in soft/ loose soil complete all as specified and as directed. |
| 90 | M&L for 100 mm thick PCC (1:4:8),type D-2, (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and as directed. |
| 91 | S&F 0.63 mm Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed. |
| 92 | M&L for preparation of new plastered surfaces and applying two coats ofcement base paint over a coat of primer of approved shade on walls complete all as specified and as directed. |
| 93 | S&F Pressed steel door frames of size 125 X 60mm (Thickness of MS Sheet 1.25mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, including filling hollow of frame with plain cement concrete (1:3:6) using 20 mm graded stone aggregate mortar complete all as specified and as directed. |
| 94 | S&F factory made flush door shutter 40mm thick factory made , solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 95 | S & F 150 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed. |
| 96 | S & F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed complete all as specified and directed. |
| 97 | S&F Aluminium bow handle 150mm complete all as specified and as directed. |
| 98 | S&F anodised aluminium powder coatedsection as in aluminium frame for doors, windows, ventilators including shutters,with one or more rebates including joining cleat for fixing complete all as specified and as directed.Note:- Necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc are deemed to be included in quoted rates. |
| 99 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 100 | S&F Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size not less than 915mmx460mm with bowl size not less than 410mm x 330mm x 160mm complete all as specified and as directed. |
| 101 | S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms)with waste hole complete all as specified and as directed. |
| 102 | S&F in repair waste fittings 32 mm bore, brass, chromium plated for Sink, wash basins etc with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed complete all as specified and as directed. |
| 103 | M&L for complete removal of existing treatment of wall and applying two coats of distemper oil emulsion over a coat of primer over a coat of 2mm thick wall care putty(in two layers)complete all as specified and as directed. |
| 104 | M&L for Preparation of plasterded or un plasteredold surfaces of ceiling and applying one coat of white wash complete all as specified and as directed. |
| 105 | S&F in repairs CP Health Faucet with 1 mtr metalic Expandable tube & hook complete all as specified and as directed. |
| 106 | S&Ftoilet paper holder, coloured vitreous china, box type fixed in wall complete all as specified and as directed. |
| 107 | S&F soap dish, vitreous china white, aprox size 160 X 160 X 90 mm. fixed to plugs with chromium plated brass screws complete all as specified and as directed. |
| 108 | Taking down chowkhat or frames not exc 1.5 Sqm each (without taking off shutter from the frame) complete all as specifed and as directed. |
| 109 | Taking downshutter of any descriptionexceeding 1.0 Sqmnexc 2Sqm eachcomplete all as specified and as directed. |
| 110 | S&F 15mm bore angle stop cock, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe complete all as specifed and as directed. |
| 111 | Taking up or down PPR/ Steel Water Tubing 15mm dia (bore) including Connections and Fittings, segregating serviceable Pipes & Fittings and Stacking properly at Site(s) for re-use, complete all as specified and as directed. |
| 112 | S&F in repairs tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 20 mm bore complete all as specified and as directed. |
| 113 | S&F in repairstubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 15 mm bore complete all as specified and as directed. |
| 114 | S&F 15mm borebib tap cast copper alloywith crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule all as per specified. |
| 115 | S&F600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers completeall as specified and as directed. |
| 116 | S&F Aluminium handle cast type anodised 100 mm long complete all as specified and as directed. |
| 117 | S&FShelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) |
| 118 | S&F PVC (SWR) 110mm bore pipe junction single (single T) equal and unequal with access door complete all as specified and as directed. |
| 119 | S&F of PVC (SWR) 75 mm dia vent cowl pipe as per specification complete all as specified and as directed. |
| 120 | Material and labour for (concelaed Type) point wiring in repairs including necessary chases cutting of wall for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) PVC sheathed multistranded copper conductor cable 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit with all accessoriesand sunk GI box for mounting of fittings like switch, socket and fan regulator etc and making good the distrubed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge |
| 121 | Onelight pointcontrolled by one, one way switch . |
| 122 | One Ceiling fan/ exhaust fan point controlled by one, one wayswitch. |
| 123 | One 3 pin socket outlet 5 Amps on the same board with other switches. |
| 124 | One 3 pin socket outlet 5 Amps on the Independent board. |
| 125 | One bell pointcontrolled by one, one way switch . |
| 126 | All as per item No- 120.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed. |
| 127 | Material and labour for (concelaed Type) point wiring including necessary chases cutting of wall for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) PVC sheathed multistranded copper conductor cable 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit with all accessoriesand sunk GI box for mounting of fittings like switch, socket and fan regulator etc and making good the distrubed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge |
| 128 | Onelight pointcontrolled by one, one way switch . |
| 129 | One Ceiling fan/ exhaust fan point controlled by one, one wayswitch. |
| 130 | One 3 pin socket outlet 5 Amps on the same board with other switches. |
| 131 | One 3 pin socket outlet 5 Amps on the Independent board. |
| 132 | All as per item No- 122.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed. |
| 133 | S&F Switch piano flush type single pole, one way 5A complete all as specified and as directed. |
| 134 | S&F Socket outlet, 2 in 1, 3 pin 5A flush type complete all as specified and as directed. |
| 135 | S&F Switch socket combination 2 in 1, 5Aflush type complete all as specified and as directed. |
| 136 | S&F Switch socket combination 2 in 1, 5A/16A, 5 in 1 flush type complete all as specified and as directed. |
| 137 | S&F bell push switch 5 amps piano type flush type complete all as specified and as directed. |
| 138 | S&F Bell AC 230 volts musical type complete all as specified and as directed. |
| 139 | S&F stepped type electronic fan regulator 100 Watt socket size flush type on the existing phenolic laminated sheet complete all as specified and as directed. |
| 140 | M&L for sub main wiring with two runs of 2.5 Sq mm and one run of 2.5 Sq mm for earth wire with multi standard copper conductors FRLSH quality, 1100 volts grade, drawn throughand including non metalic rigid PVC conduit with all conduit accessories (including concealing and making good to the disturbed surfaces of walls, ceiling,floors etc. including making good the disturbed surfaces and paint touch up to match with the existing surface) including taking down old unsv one complete all as specified and as directed. NOTE:- Two runs of 2.5 Sq mm + one run of 2.5 Sq mm and one run of PVC Conduit and its accessories of suitable size shall be measured as one unit length. |
| 141 | M&L for sub main wiring with two runs of 1.5 Sq mm and one run of 1.5 Sq mm for earth wire with multi standard copper conductors FRLSH quality, 1100 volts grade, drawn throughand including non metalic rigid PVC conduit with all conduit accessories (including concealing and making good to the disturbed surfaces of walls, ceiling,floors etc. including making good the disturbed surfaces and paint touch up to match with the existing surface) including taking down old unsv one complete all as specified and as directed. NOTE:- Two runs of 1.5 Sq mm + one run of 1.5 Sq mm and one run of PVC Conduit and its accessories of suitable size shall be measured as one unit length. |
| 142 | M&L for sub main wiring with two runs of4 Sq mm and one run of 4 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn throughand including PVC conduit pipeincluding including taking down old unsv one complete all as specified and as directed. NOTE:- two runs of 4 Sq mm + one run of 4 Sq mm and one run of PVC conduit and its accessories of suitable size shall be measured as one unit length . |
| 143 | S&F LED light fitting 1 x 20 W (4 FT), wall /surface mounted, integrated type with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size in & incl flexible hose from ceiling rose to fitting complete all as specified and as directed |
| 144 | S&F LED light fitting 1 x 10 W (2 FT), wall /surface mounted, integrated type with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size in & incl flexible hose from ceiling rose to fitting complete all as specified and as directed |
| 145 | S&F in replacement for Decorative wall mounted light fitting made up of polycarbonate including 9 watt LED lamp with B-22 base including taking down old unsv light fitting complete all as specified and as directed. |
| 146 | S&F ceiling rose 3 terminal PVC/Polycarbonate isolated body complete all as specified and as directed. |
| 147 | Supply , fixing and testing of LED Bldg Security light fitting of capacity 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with and including 1.2 mtr GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling of holes as reqd and connecting up with flexible copper cable of size 0.75 sqmm 3 core from ceiling rose to the light fitting complete all as specified and as directed. |
| 148 | S&F in repairs LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling and connecting up with driver, three core flexible copper conductor of suitable size complete all as specified and as directed. |
| 149 | Taking down carefully exisiting water heater storage 25 Ltrs Capacity, PVC connection GI Tubes, Bip taps, and stop valve safecustody and refixing, testing after compltion of the work complete all as specified and as directed. Note : All fansterns Nut and Bolts deemed to be included inquoted rates. |
| 150 | S&F in repairs MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity and making good the disturbed surfaces to match with existing specification , complete all as specified and as directed.Note : MCBs will be measured and paid separately. |
| 151 | S&F in repairs MCB SPN 32 Amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning MCB DBcomplete all as specified and as directed |
| 152 | S&F in repairs MCB SP 6 to 32 Amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning MCB DBincl taking down old unsv MCB complete all as specified and as directed |
| 153 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250MM complete all as specified and as directed. |
| 154 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed.Note : Old Exhaust Fan shall be deposited toEM store yard. |
| 155 | M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 16 sq mm, 2 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. |
| 156 | M&L for spread fine river sand in trenches complete all as specified and as directed. NOTE: Punned down thickness shall only be measured and paid. |
| 157 | M&L for laying brick sub class \"B\" old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed |
| 158 | Supply & laying tubes \" light grade\" galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 40 mm dia bore complete all as specified and as directed. |
| 159 | S&F metal clad AC socket point single pole and neutralenclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps complete all as specified and as directed. |
| 160 | Taking down and M&L for overhauling/ servicing of ceiling fan of any size / sweep (i.e 1200/1400mm sweep) and make comprising dismantaling, cleaning internally and externally and cleaning / lubricating of bearing / bushes using fresh lubricant (Oil grease) re-assembling, checking of split pin, hook assembly & hanging andincluding provision of cable fromceiling rose or connector to fan and testing for proper functioning complete all as specified and as directed. |
| 161 | Supply and laying tubes Medium grade galvanised GI tubing with all fittings, fixed complete to walls/poles/laid in floors/trenchs/road crossing of size 15 mm dia bore complete all as specified and as directed. |
| 162 | S&F Stop valves, cast copper alloy, fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as per specified and as directed. |
| 163 | Supply, Fixing and testing of vertical type wall mounted storage water heater of Capacity 25 Ltrs BEE 5 Star rated or minimum Standing Loss of 0.511 kWh , 240V, 50Hz with Maximum power consumption of 2KW , dry powder fero glass line coating technologyfor inner tank with incoloy heating elementwith minimum4 years warranty , ABS outer body , 2 units of PVC connection pipe with length of 450mm length for hot and cold water supply with complete Accessories complete all asspecified and as directed. |
| 164 | M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and as directed. NOTE:- (i)The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1 chamber, CI cover 10 m thick, funnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 441 of MES SSRPart-II. (ii)Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy