Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 04-01-2026 | AMENDMENT IN TENDER DOCU FOR SPL REPAIR TO BLDG NO T 55 IN N ZONE SPL REPAIR TO BLDG NO T 36 AND T 39 OF 1 COY 15 EW BN PROVN OF PATHWAY ALONGWITH COVERED SHED FROM BLDG NO T 9 TO OPT 24 IN F ZONE AND ADDN ALTN OF FLOORING FOR BLDG NO P 487 AND P 48 | Other | 10-01-2026 |
| 2 | 03-01-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 10-01-2026 |
| 3 | 22-12-2025 | AMENDMENT IN DATE FOR SPL REPAIR TO BLDG NO T 55 IN N ZONE SPL REPAIR TO BLDG NO T 36 AND T 39 OF 1 COY 15 EW BN PROVN OF PATHWAY ALONGWITH COVERED SHED FROM BLDG NO T 9 TO OPT 24 IN F ZONE AND ADDN ALTN OF FLOORING FOR BLDG NO P 487 AND P 486 IN E Z | Date | 03-01-2026 |
| Sl. No. | Item Description |
| 1 | Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 2 | Taking down chowkhat or frames not exc 1.5 Sqm each (without taking off shutter from the frame) complete all as specified and as directed. |
| 3 | Taking down chowkhat or frames exc 1.5 Sqm but not exc 4 Sqm each (without taking off shutter from the frame) complete all as specified and as directed. |
| 4 | Taking down shutter not exceeding 1 Sqm each complete all as specified and as directed. |
| 5 | Taking downshutter of any descriptionexceeding 1.0 Sqmnexc 2Sqm eachcomplete all as specified and as directed. |
| 6 | M&L for second class hardwood as in scantlings clean sawn timberfixed including dismantling old timber scantlings 40 sqcm and over in section, in unframed work any position complete all as specified and as directed. |
| 7 | All as per Ser item No 6.00 (here-in-before) but except timber complete all as specified and directed. |
| 8 | M&L 15mm thick plastering in CM (1:4) on one side of lathing in two separate layers without using extra cementand surface finished even and smooth including demolition of reed, lathing single or double, including battens and plaster or chicken wire lathing with and including provn of GI wire netting 0.71 mm dia and 12 mm mesh lathing in to reed in walls incl all laps cutting and waste complete all as specified and as directed. |
| 9 | Demolition of reed, lathing single or double, including battens and plaster or chicken wire lathing complete all as specified and as directed. |
| 10 | M&L GI wire netting 0.71 mm dia and 12 mm mesh lathing in to reed and bird proofing in walls incl all laps cutting and wastecomplete all as specified and as directed. |
| 11 | M&L 12 mm thick plastering in CM 1:6 the other side of lathing finished even and smooth without using extra cement complete all as specified and directed. |
| 12 | Dismantling of chicken wire lathing complete all as specified and as directed. |
| 13 | M & L 25mm thick and 200 mm wide second class hard wood boarding , plained one side with butt joints as ineaves boards including dismantling of old boarding from its position complete all as specified and as directed. |
| 14 | M & L for PCC (1:4:8) type D-2, 100 mm thick (using 40 mm graded stone aggregate) as in sub base complete all as specified and as directed. |
| 15 | M&L 25 mm thick PCCtype B-0, 1:2:4 (using 10mm graded stone aggregate) as in sub base of flooring finished even and fair using extra cementcomplete all as specified and as directed. |
| 16 | M & L for PCC (1:2:4), type B-2, 100 mm thick (using 40 mm graded stone aggregate) as in hardstanding, surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 17 | M&L for Abrasion resistant self-levelling epoxy floor coating with solventless epoxy 3mm thick (2mm Screed and 1mm top coat) withstand attacks by oils lubricants, alkalis,acids,water, abrasion and impact like no other polymers with excelent bonding properties applied with following methods complete all as specified and as per manufactures instruction and as directed by Engineer in Charge. :-(i) Cleaning and Surface Preparation.(ii)Primer Coating(iii) Cracks and joint filling(iv) Epoxy finish coating |
| 18 | M&L for light shade coloured vitrified ceramic tiles 8-9mm thick (Square / rectangular) of area exceeding 0.36sqm but not exceeding 0.42 Sqm each, in floors laid over and including 15mm thick screed bed or bedding layer of mortar for laying floor finishes in Cement Mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 19 | All as per Item No 18.00 (here-in-before) but on vertical surfaces such as skirting , dado risers to stepsover and including 10 mm thick backing coat in Cement Mortar 1:4. |
| 20 | M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm,in floors laid over and including 15mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor finishes, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 21 | M&L for Glazed ceramic coloured tiles in vertical surface 300 mm X 200 mm / 350 x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tileover and including baking coat of 10 mm thick in Cement Mortar (1:4), including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 22 | S&Fsteelworkintubulartrusses, post, purlinsincludingspecialshapedwasheretc.CompleteusingERWorinductionbuttweldedtubesconformingtoIS1161-1979gradest-240complete all as specified and directed by Engineer - in – Charge |
| 23 | S&F MS screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nuts, length of bolt exc 10cm andn Exc 15 cmlong dia of neck 11 to 15 mm complete all as specified and as directed. |
| 24 | M&L for 75 mm thick PCC (1:3:6) type C-2 , (using 40 mm graded stone aggregate) in plinth protection/aprons/path laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and as directed. |
| 25 | S&F anodised aluminium powder coatedsection as in aluminium frame for doors, windows, ventilators including shutters,with one or more rebates including joining cleat for fixing complete all as specified and as directed.Note:- Necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc are deemed to be included in quoted rates. |
| 26 | S&F Sheet glass 4.8mm thick clear/sun shade colour glass, ordinary quality and glazing with oil putty in squares exceeding 0.5sqm in each pane complete all as specified and as directed. |
| 27 | S&F aluminium anodised grill with mesh size 75 mm and aluminium bar 6 mm XPM type including all accessories such as channels for fixing grill screws etc, aluminium section 15 micron thick anodizing complete all as specified and directed. |
| 28 | M&L for fixing 4 mm thick anodised aluminium composite panel fixed in aluminium frame including necessary rubber beading, jointing cleats complete all necessary items to fix with frame and all as specified and directed by Engineer-in Charge. |
| 29 | S&F 30mm thick factory made flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 30 | M&L for second class hardwood plain fillets exc 13sqcm and notexc. 25sqcm, square or rectangular in section, wrought, secured with nails or brads complete all as specified and as directed. |
| 31 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, as per specification complete all as specified and as directed. |
| 32 | S&F Factory made solid panel PVC doorshutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined to-gether with solvent cement as per specification complete all as specified and as directed. |
| 33 | S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 34 | S&F butt hinges medium grade cold rolled mild steel and fixed size of hinges 100 mm long size complete all as specified and as directed. |
| 35 | S&F Aluminium anodised barrel tower bolt of extruded section and fixed 200 mm long complete all as specified and as directed. |
| 36 | S&F Aluminium handle cast type anodised 150 mm long complete all as specified and as directed. |
| 37 | S&F in repairs Mortice lock,vertical type Brass 2 levers, size 100 mm complete all as specified and as directed. |
| 38 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed. |
| 39 | M&L for brick work with sub class B bricks(using old size burnt bricks) straight or curved on plan exc 6 m mean radius in CM (1:6) including demolition of old brick work complete all as specified and as directed. |
| 40 | M&L brick work with sub class B bricks(using old size burnt bricks) straight or curved on plan to any radius in half brick thick walls built in CM (1:4) including demolition of old brick work complete all as specified and as directed. |
| 41 | M&L for Cement Concrete (1:2:4) Type B-2,(using 40mm graded aggregate) as in foundation filling and mass concrete complete all as specified and as directed. |
| 42 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick or concrete work even and smooth without using extra cement complete all as specified and as directed. |
| 43 | M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick or concrete work even and smooth without using extra cement complete all as specified and as directed. |
| 44 | M&L for applying two coats of oil bound distemper over a coat of primer on new plastered surfaces of walls including preparation of newsurface complete all as specified and as directed. |
| 45 | M&L for preparation of new plastered surfaces ofwall and applying two coat of oil emulsion distemper over a coat of primer over 2mm thick of wall care putty(in two layers) on wall surfaces complete all as specified and directed. |
| 46 | M&L for preparation of old decorated surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applyingone coat of oil bound distemper of approved shade/tint all as specified. |
| 47 | M&L for complete removal of exisitng treatment of old decorated surfaces ofwall applying two coat of oil emulsion distemper over a coat of primer over coat of wall care putty(2mm thick in two layers) to obtain smoothness of wall surfaces complete all as specified and directed. |
| 48 | M&L for preparation of new plastered surfaces and applying two coat of exterior weather paint over one coat of primerover a coat of 2mm thick wall care putty onwall surface complete all as specified and directed. |
| 49 | M&L for complete removal of exisitng treatment of old decorated surfaces ofwall applying two coat of exterior weather paint over one coat of primerover a coat of 2 mm thick wall care putty(in two layers) onwall surface upto 3 storeyed bldg complete all as specified and as directed. |
| 50 | M&L for preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink wood primer complete all as specified and as directed. |
| 51 | M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying onecoat of synthetic enamel paint complete all as specified and as directed. |
| 52 | M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 53 | M&L for preparation of old steel surfaces exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 54 | S&F in repairs tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 20 mm bore complete all as specified and as directed. |
| 55 | All as per Serial Item No 54.00 (here-in-before) but fixing only complete all as specified and directed. |
| 56 | S&F in repairs tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 15 mm bore complete all as specified and as directed. |
| 57 | All as per Serial Item No 56.00 (here-in-before) but fixing only complete all as specified and directed. |
| 58 | S&F in repairs CP Health Faucet with 1 mtr metalic Expandable tube & hook complete all as specified and directed. |
| 59 | S&F in repairs vitreous china wash basin, size 550 x 400mm white including brackets, and waste coupling & pipe of 32mm dia, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and as directed. |
| 60 | S&FVitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) and including EWC Seat cover complete all as specified and as directed. |
| 61 | S&F PVC valveless, syphonic action type, 10 ltr flushing cistern, low level,white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed. |
| 62 | S& F Pillar taps15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot\" or ‘Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed. |
| 63 | S&F in repairs forbib tap cast copper alloy, fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrulesuitable for 15 mm dia bore pipe and fixed as approved by complete all as specified and as directed. |
| 64 | S&F in repairs for 15mm dia of pipe angle stopvalves,fancy type and chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for Unions and fixedcomplete all as specified and as directed. |
| 65 | S&F in repairs PVC connection 15mm dia and 45cm long with two Nosof brass checknuts and washerscomplete all as specified and as directed. |
| 66 | S&F grating doom 125mm dia with waste hole of PTMT (Min wt 40 gms) complete all as specified and as directed. |
| 67 | S& F in repairs600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers completeall as specified and as directed. |
| 68 | M&L for cement concrete type B-1 (1:2:4) (using 20 mm graded stone agg) as in surface channels and drains complete all as specified and as directed. |
| 69 | M&L for PCC (1:3:6), type C-1 (using 20mm graded stone aggregate) as in coping including necessary formwork complete all as specified and as directed. |
| 70 | S & F 75mm dia, PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 71 | S&F in repairsfor Draperly rod /Harrison rails of CP of 20mm dia with fixing brackets , stops, rollers and ringscomplete all as specified and as directed. |
| 72 | S&F PVC (SWR) 110mm dia single socketed in any length with rubber ring joints laid in trenches or in floor complete all as specified and as directed. |
| 73 | S&F PVC (SWR) 110mm dia bends in any radius complete all as specified and as directed. |
| 74 | S&F(SWR) 110mm bore pipe junction single (single T) equal and unequal with access door complete all as specified and as directed. |
| 75 | M & Lfor 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and ad directed. |
| 76 | S & F 75mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 77 | S&FPre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specifiedwith and including dismantling of old plain/corrugated Asbestos cement sheet complete all as specified and as directed. |
| 78 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws asspecifiedwith and including dismantling of old plain/corrugated Asbestos cement sheet complete all as specified and as directed. |
| 79 | M&L for PCC 1:4:8 Type D-2(using 40mm graded aggregate) 75 mm thick as in sub base finished even and rough |
| 80 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws asspecified complete all as specified and as directed. |
| 81 | S&FPre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed. |
| 82 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to GDE Fe 410-W(Gde-E-250) quality-A including dismantling of old steel from its position complete all as specified and as directed. |
| 83 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to GDE Fe 410-W(Gde-E-250) quality-A complete all as specified and as directed. |
| 84 | S & F Plates (plain or chequered) channels,squarecutor notched (ordinaryand countersunk) forming holes, without any attachment conforming to Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed. |
| 85 | S & F for4 mm thick of size 600x600mmHSPC (high pressure Steam Cured) pre-painted self embossed, textured designer boardE-Board Classic to be fixed or laid with GI frame grid/section size 600mm x 600mm with main runner 38x24x0.9 mm thick, cross tee 8.6x24x0.9mm and wall angle 19 x19x0.9mm duly suspended with 4mm dia GI bar hangers 1200mm centre to centre both waysfixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any sizeincluding dismantling of old unsv ceiling boards (fibre, pulp, insulation, etc.) any thickness including cover fillets of any description and at any location complete all as specified and as directed. |
| 86 | M&L for 2nd class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pined joints complete all as specified and directed. |
| 87 | S&F factory made 30 mm thick 2nd class hardwood plain framed pannelled shutter (any number of panels) with panels of timber flat on both sides or of veneered particle board medium density , wood particle board with commercial face veneers , supplied and fitted to chowkats complete all as specified and as directed. |
| 88 | S&F in repairaluminium (extruded section) bodydoor closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 89 | S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 90 | Surface excavation n.exc 15cm deep and getting out in soft/ loose soil complete all as specified and as directed. |
| 91 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in soft/ loose soil complete all as specified and as directed. |
| 92 | Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth; for foundation etc. or for shafts wells cesspits man-holes pier holes etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 93 | Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified ans as directed. |
| 94 | Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified and as directed. |
| 95 | M&L for hardcore (broken stone/boulders) of gauge exc 63mm but n.exc 100mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammmed to a true surface etc complete all as specified & directed by Engr-in-Charge. |
| 96 | M&L for PCC (1:2:4) type B-2, (using 40mm graded stone aggregate) and paving 100 mm thick complete all as specified and as directed. |
| 97 | S&F mild steel screw bolts of diameter of neck 16 to 20 mm(machine made ) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut length of bolt exc 22.5 cm and n exc 30 cm long complete all as specified and as directed. |
| 98 | M&L for chequered cement concrete tiles of size not less than 300x300x25mm thick laid over and including 15mm thick screed bedfor laying floor finishes in cement mortar 1:6, etc, set, jointed and pointed in neat cement slurry with grey cement and pigmentscomplete all as specified and as directed. |
| 99 | M&L for Point wiring in repairs complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable1100 volts grade with multi-stranded copper conductors, drawn throughand including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connected to common earth dolly, including PVC rectagular box for mounting switches / sockets / regulators etc. as required at site and 50 mm deep complete all as specified and as directed. |
| 100 | Onelight pointcontrolled by one, one way switch . |
| 101 | One Exh/Ceiling fan point controlled by one, one wayswitch. |
| 102 | One 3 pin socket outlet 5 Amps on the same board with other switches. |
| 103 | One 3 pin socket outlet 5 Amps on the Independent board. |
| 104 | All as per item No-99.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed. |
| 105 | S&F Switch piano flush type single pole, one way 5A complete all as specified and as directed. |
| 106 | S&F Socket outlet, 2 in 1, 3 pin 5A flush type complete all as specified and as directed. |
| 107 | S&F Switch socket combination 2 in 1, 5Aflush type complete all as specified and as directed. |
| 108 | S&F Switch socket combination 2 in 1, 5A/16A, 5 in 1 flush type complete all as specified and as directed. |
| 109 | S&F stepped type electronic fan regulator 100 Watt socket size flush type on the existing phenolic laminated sheet complete all as specified and as directed. |
| 110 | S&Fceiling rose 3 terminal PVC/Polycarbonate isolated body with PVC round/squareblock complete all as specified and as directed. |
| 111 | M&L for sub main wiring with two runs of4 Sq mm and one run of 4 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn throughand including PVC double locked Casing & caping including taking down old unsv one complete all as specified and as directed. NOTE:- two runs of 4 Sq mm + one run of 4sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length |
| 112 | S&Fin repairs LED Light fitting 1 x 20 watt (4 Ft), basic all purpose surface and wall mounted LED battern with polycarbonate housing & intergrated electric driver with all accessoriesincl connecting up with and incl twin/ three core twisted flexible copper conductor cable of suitable size in and incl flexible hose from ceiling rose to fitting complete all as specified and as directed. |
| 113 | S&Fin repairs LED Light fitting 1 x 10 watt (2 Ft), Wall/ Surface mounted, intergrated type with all accessories internally prewired and incl connecting up with, including two Nos PVC blocks and connecting upwith flexible copper cable of size 0.75 Sq mm 3 core and flexible pipe from ceiling rose to the light fitting complete all as specified and as directed. |
| 114 | Supply , fixing and testing in repairs/replacement of LED Bldg Security light fitting of capacity 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with and including 1.2 mtr GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling of holes as reqd and connecting up with flexible copper cable of size 0.75 sqmm 3 core from ceiling rose to the light fitting complete all as specified and as directed. |
| 115 | S&F in repairs/replacement for Decorative wall mounted light fitting made up of polycarbonate including 9 watt LED lamp with B-22 basecomplete all as specified and as directed. |
| 116 | S&F in repairs LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling and connecting up with driver, three core flexible copper conductor of suitable size complete all as specified and as directed. |
| 117 | M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed. |
| 118 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and as directed. |
| 119 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 120 | S&F in repairs MCB Distribution board double door type SPN 12 way, sheet steel, powder painted, with copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed. |
| 121 | S&F in repairs MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, with copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed. |
| 122 | Supply and fixing 415V 10KA \"C\" curve miniature circuit breaker TPN 40 to 100 Amp(MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed. |
| 123 | S&F in repairsMCB SPN 40 to 63 Amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning MCB DBcomplete all as specified and as directed |
| 124 | S&F in repairs MCB SPN 32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB \"C\" seriescomplete all as specified and as directed. |
| 125 | S&F in repairs MCB SP 5-40 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB \"C\" seriescomplete all as specified and as directed. |
| 126 | Taking down carefully exisiting water heater storage 25 Ltrs Capacity, PVC connection GI Tubes, Bip taps, and stop valve safecustody and refixing, testing after compltion of the work complete all as specified and as directed. Note : All fansteners Nut and Bolts deemed to quoted rate. |
| 127 | Supply and laying tubes Medium grade galvanised GI tubing with all fittings, fixed complete to walls/poles/laid in floors/trenchs/road crossing of size 15 mm dia bore complete all as specified and as directed. |
| 128 | S&F Stop valves, cast copper alloy, fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 129 | S&F15mm boreBib tap fancy type chromium plated with long shank complete all as specified and as directed . |
| 130 | M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 16 sq mm, 4 core including taking up/down old unsv onecomplete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. |
| 131 | M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 16 sq mm, 2 core including taking up/down old unsv onecomplete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. |
| 132 | M&L for spread fine river sand in trenches complete all as specified ans as directed. NOTE: Punned down thickness shall only be measured and paid. |
| 133 | M&L for laying brick sub class \"B\" old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed |
| 134 | Supply & laying tubes \"light grade\" galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 32 mm dia bore including taking out unsv GI tubing complete all as specified and as directed. |
| 135 | Supply & laying tubes \" light grade\" galvanised, with all fittings, fixed complete to walls, poles, ceilings for protection of cables of size 40 mm dia bore including taking out unsv GI tubing complete all as specified and as directed. |
| 136 | M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and as directed. NOTE:- (i)The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1 chamber, CI frame with CI coverfunnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 441 of MES SSRPart-II. (ii)Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy