| Sl. No. | Item Description |
| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (including equivalent Design Mix) |
| 2 | Surface dressing of the ground including removing vegetation and in equalities not exceeding 15 cm. Deep and disposal of rubbish, lead upto 50 m and lift up to 1.5 m All kinds of soil |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil |
| 4 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift |
| 6 | Supplying and filling in plinth with jamuna sand under floors including, watering, ramming consolidating and dressing complete. |
| 7 | Supplying chemical emulsion in sealed containers including delivery as specified Chlorpyriphos / Lindane emulsifiable concentrate of 20% |
| 8 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 9 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 11 | Providing and laying damp proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 12 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. |
| 13 | Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 14 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed by dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 15 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 16 | All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 17 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 18 | Centering and shuttering including strutting propping etc. and removal of form work for : Foundations, footings, bases of columns etc. for mass concrete. |
| 19 | Suspended floors, roofs, landings, balconies and access platform. |
| 20 | Shelves (Cast in situ). |
| 21 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 22 | Columns, pillars, piers, abutments, posts and struts. |
| 23 | Stairs (excluding landings) except spiral staircases. |
| 24 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) |
| 25 | Edges of slabs and breaks in floors and walls. |
| 26 | Under 20 cm wide. |
| 27 | Weather shade, Chajjas, corbels etc., including edges |
| 28 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D ormore. |
| 29 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 30 | Providing, transporting, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 31 | Providing and fixing in position copper plate as per design for expansion joints. |
| 32 | Providing and filling in position, blown bitumen in expansion joints. |
| 33 | Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints.300 mm wide. |
| 34 | Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof. |
| 35 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 36 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 37 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S.bars at every third course of masonry work. |
| 38 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 39 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 40 | Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means. |
| 41 | Providing and fixing ISI marked flush door shutters conforming to IS 2202 (part I) decorativie type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 30 mm thick including ISI marked stainless steel butt hinges with necessary screws |
| 42 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 30 mm thick shutterWith ISI marked stainless steel butt hinges of required size Second class teak wood. |
| 43 | Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately) |
| 44 | Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc.complete as per direction of Engineer-in-charge. |
| 45 | Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. 200mm |
| 46 | Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. |
| 47 | Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete :115 mm |
| 48 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : 25 mm dia (heavy type) |
| 49 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 50 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady] the frame. |
| 51 | Providing and fixing to existing door frames. 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge |
| 52 | Providing and fixing heavy quality stainless steel Door stopper with necessary screws, etc. complete. |
| 53 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 54 | Providing and fixing SS sliding door bolts, ISI marked , with nuts and screws etc. complete :250 x 16mm |
| 55 | Providing and fixing SS tower bolts, , with necessary screws etc. complete :200 x 10 mm |
| 56 | Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. Double strip (horizontal type) |
| 57 | Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.65mm |
| 58 | Providing and fixing 50 mm bright finished brass cup board or wardrobe knob of approved quality with necessary screws. |
| 59 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). |
| 60 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 61 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineerin-charge: |
| 62 | ProfileFixing with adjustable lugs with split end tail toeach jamb |
| 63 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 64 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap point locking system ( Height upto 1.8m) between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for :(i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3(ii) Sites with structure height more than 20m for all wind speedsThree track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R3 series with frame (98 mm & above ) x (40 mm & above) & both glazed and fly screen sash (30mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed pannelThree track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R3 series with frame (98 mm & above ) x (40 mm & above) & both glazed and fly screen sash (30mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed pannel along with multi-point locking system ( Height upto 1.8m) |
| 65 | Fixed window / ventilator without mullion / transom Using R3 series with frame (55mm & above) x (45mm & above).( Height upto 2.5m) |
| 66 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 67 | With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) |
| 68 | Filling the gap in between aluminium frame & adjacent RCC / Brick / Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge. Upto 5 mm depth and 5 mm width |
| 69 | Providing and Fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. With 12 mm mild steel U Beading |
| 70 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness |
| 71 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spacedjoints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. |
| 72 | 12 mm cement plaster of mix :1:6 (1 cement : 6 coarse sand) |
| 73 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). |
| 74 | 6 mm cement plaster of mix. 1:3 (1 cement : 3 fine sand) |
| 75 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 76 | Neat cement punning |
| 77 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 78 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats |
| 79 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately), for fixed portion :Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 80 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 81 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 82 | Melamine polishing on wood work (one or more coat). |
| 83 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sq.m. |
| 84 | Extra for providing edge moulding to 18 mm thick marble stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.Granite work |
| 85 | Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 86 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Double charge vitrified tile polished finish of size of Tile 600 x 1200 mm |
| 87 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600 x 600 mm |
| 88 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25mm thick |
| 89 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 90 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 91 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 92 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 93 | Providing and fixing on wall face unplasticised- PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS : 13592 type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. |
| 94 | Coupler 110 mm |
| 95 | Bend 87.5° 110 mm bend |
| 96 | Shoe (Plain) 110 mm |
| 97 | Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50 x 50 x 50 mm hard wood plugs screwed with MS screws of required length including cuting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete 110 mm |
| 98 | Providing and fixing to the inlet mouth of rain water pipes cast iron grating 15 cm diametre and weighing not less than 440 grams. |
| 99 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase |
| 100 | Making khurras 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge and making and finishing the outlet complete. |
| 101 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 102 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick |
| 103 | Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. |
| 104 | Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer’s specifications and as approved by engineer In charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., washing with water all complete. The contractor shall give guarantee for the perfomance of SRI and also the durabitity of coating, all complete as per direction of Engineer-in-incharge. |
| 105 | Finishing walls with textured exterior paint of required shade : New Work (Two or more coats applied @ 3.28 ltr/ 10 Sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 106 | Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 107 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineerin- charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 108 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 109 | Providing and fixing Health Faucet With Tube 1 Meter & Hook, S. Steel 304 fixed to wall with rawl plugs screws complete.of quality and make as approved by Engineer - in - charge. |
| 110 | Providing and fixing CPbrass Two way angle cock of approved quality and colour. |
| 111 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 112 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board 510x1040 mm bowl depth 250 mm |
| 113 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe |
| 114 | 32 mm dia |
| 115 | 40 mm dia |
| 116 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 mlonsumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 117 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 15 mm nominal bore |
| 118 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 119 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm |
| 120 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length |
| 121 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineerin- charge. |
| 122 | Providing and fixing CP Brass wall mixer with with bend for over head shower & CP overhead shower with arm. Make as approved by Engineer in charge. 15 mm nominal dia |
| 123 | Providing and fixing CP Brass Kitchen Sink Mixer Swan150 mm (6\") long swivel spout, connecting legs and wall flange. Quality & make as approved by Engineer in charge. 15 mm nominal dia |
| 124 | Providing and fixing toilet paper holder :C.P. brass |
| 125 | Providing and Fixing 600 mm long C.P. brass towel rail with C.P. Brass brackets fixed to raw plugs fixed with C.P. brass screws complete including cutting and making good the walls wherever required. Quality & make as approved by Engineer in charge. |
| 126 | Providing and fixingSoap dish/container -SS304, Chrome Platedfixed in position by rawl plugs and CP brass screws. Quality & make as approved by Engineer in charge. |
| 127 | Providing and fixing Soap Dispenser (S. Steel ) complete including fixing on wallwith screw complete.Quality & make as approved by Engineer in charge. |
| 128 | Providing and fixing wall mounted recess hand dryer complete including fixing on wall with PVC rawl plug and Steel screw complete. Quality & make as approved by Engineer in charge. |
| 129 | Providing and fixing U Shaped Rail Wall mounted (with hinge) 600 x 100 mm complete including fixing to the wall etc complete in all respect. Quality & make as approved by Engineer in charge. |
| 130 | Providing and fixing CP grating of approved quality and colour.Circular type 100 mm nominal dia. Quality & make as approved by Engineer in charge. |
| 131 | Providing and fixing CP grating of approved quality and colour.Circular type 125 mm nominal dia with waste hole. Quality & make as approved by Engineer in charge. |
| 132 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 133 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 134 | Providing and fixing Glass Shelfedge round off complete including fixing on wall with SS railing & screw complete on front to guard toileteries . As per direction of engineer in charge |
| 135 | Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 136 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :300 mm dia. R.C.C. Pipe |
| 137 | Providing and fixing soil, waste and vent pipes : 100 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
| 138 | 75 mm diametre : Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
| 139 | Providing and fixing plain bend of required degree. 100 mm dia |
| 140 | Hubless centrifugally cast (spun) ironpipes epoxy coated inside & outside IS:15905 |
| 141 | 75 mm dia Hubless centrifugally cast (spun) ironpipes epoxy coated inside & outside IS:15905 |
| 142 | Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 100 mm dia SS 304 grade coupling with EPDM rubber gasket |
| 143 | 75 mm dia SS 304 grade coupling with EPDM rubber gasket |
| 144 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100 mm inlet and 100 mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 145 | Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 146 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :With 20x20 mm square bar |
| 147 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 148 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 Fine sand ) in SCI/CI Pipes 100mm dia pipe |
| 149 | Providing and Fixing terminal guard 100mm Dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 150 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall |
| 151 | 20 mm dia nominal bore |
| 152 | 25 mm dia nominal bore |
| 153 | 32 mm dia nominal bore |
| 154 | 40 mm dia nominal bore |
| 155 | 50 mm dia nominal bore |
| 156 | 80 mm dia nominal bore |
| 157 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 20 mm dia nominal bore |
| 158 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 159 | 20 mm dia nominal bore |
| 160 | 25 mm dia nominal bore |
| 161 | 32 mm dia nominal bore |
| 162 | 40 mm dia nominal bore |
| 163 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 164 | 25 mm nominal bore |
| 165 | Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : |
| 166 | 25 mm nominal bore |
| 167 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 168 | Wiring for light point / fan point /exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with modular switch,modular plate ,suitable GI Boxand earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.a) Group B |
| 169 | Wiring for group controlled (looped) light point / fan point /exhaust fan point/ call bell point (without independent switch) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC Conduit,and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B |
| 170 | Wiring for light /power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed PVC conduit along with 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 171 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC Conduit as required. |
| 172 | 2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 173 | 2x2.5 sq.mm + 1 x 2.5 sq.mm earth wire |
| 174 | 2 x 4 sq.mm + 1 x 4 sq.mm earth wire |
| 175 | 2x6 sq.mm + 1x6 sq.mm earth wire |
| 176 | 4x10 sq.mm + 2x6 sq.mm earth wire. |
| 177 | 4x16 sq.mm + 2x6 sq.mm earth wire. |
| 178 | Supplying and fixing suitable size GIbox with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch ,connectionetc as required. |
| 179 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 and 5/6 amps modular socket outlet and 15/16 amps modular switch connections,etc as required. |
| 180 | Supplying and fixing of following sizes of medium class PVC conduit along with acessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 181 | 25 mm |
| 182 | 32 mm |
| 183 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing of 25A modular socket outlet and 25A modular SP MCB \"C\" curve including connections painting etc. as required. |
| 184 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 185 | Supplying & installation of following capacity vertical type 25 Ltr Geyserwith glassline tank on the existing wall with the help of fastener i/c testing & commissioning, complete as As per direction of engineer in charge |
| 186 | Supplying and fixing following way, horizontal type single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) |
| 187 | 6 way (2+6), Double door |
| 188 | 12 way (2+12), Double door |
| 189 | Supplying & fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) |
| 190 | 4 way (4+12) Double door |
| 191 | 6 way (4+18) Double door |
| 192 | Supplying & fixing 5 amps to 32 amps rating.240/415 volts.10kA, \"C\" curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing & commisioning etc.as required Single pole |
| 193 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. b) 40 amps |
| 194 | Supplying & fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 195 | a) 40 amps |
| 196 | b) 63 amps |
| 197 | Supplying and fixing following way surfac/reccess mouting vertical type 415V TPN MCB distribution board of sheet steel dust protected duly powder painted inclusive of 200A timmed copper bus bar common neutral link earth bar din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required). 4 way (4+12) Double door |
| 198 | Supplying and Fixing following rating 4P 415V isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 199 | 40A |
| 200 | 63A |
| 201 | 100A |
| 202 | Supplying and Fixing following rating 2P 240V isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A |
| 203 | SITC of cubical type sheet steel clad IP52, wall / floor mounted totally enclosed LTswitch board suitable or use on 415 V 3 phase 4 wire 50 cycles complete housed with incoming and outgoing bus bars including interconnection accessories with cable glands etc complete as required and with following incoming and outgoing switchgear as per specs and drawings.POWER PANELINCOMER1 No. 200A, 4P MCCB (16KA)Each Incomer Metering & Protection.1 Set of Multifunction meter (96x96mm) for V/A/PF/Hz/KVAH/KWH with LCD/LED Display as per IS 146973 Nos. 200/5A ratio CTs 15 VA class 5P 103 Nos. phase indicating lights with control fuses.1 Set of control fuses & control terminals.3 Nos. breaker ON/OFF/TRIP indication lamp with SP MCB.Bus Bar 250 Amp TPN Aluminium bus bar with heat shrinkable coloured insulated PVC sleeves having a current density of not less than 1.0 Amp sq.mm. and the neutral bus of50% capacity interconnections between bus bars and breakers shall be through solid strip.Outgoings 100A 4P MCCB 10KA - 07 Nos63A 4P MCB 10KA - 03 Nos. |
| 204 | LIGHT PANELINCOMER1 No. 100A, 4P MCCB (16KA)Each Incomer Metering & Protection.1 Set of Multifunction meter (96x96mm) for V/A/PF/Hz/KVAH/KWH with LCD/LED Display as per IS 146973 Nos. 100/5A ratio CTs 15 VA class 5P 103 Nos. phase indicating lights with control fuses.1 Set of control fuses & control terminals.3 Nos. breaker ON/OFF/TRIP indication lamp with SP MCB.Bus Bar 150 Amp TPN Aluminium bus bar with heat shrinkable coloured insulated PVC sleeves having a current density of not less than 1.0 Amp sq.mm. and the neutral bus of50% capacity interconnections between bus bars and breakers shall be through solid strip.Outgoings40A 4P MCB 10KA - 03 Nos. 63A 4P MCB 10KA - 08 Nos. 40A DP MCB 10KA - 02 Nos. |
| 205 | Supplying of following sizes of PVC insulated PVC sheathed XLPE armoured aluminum conductor power cable of 1.1 KV grade as required. |
| 206 | a) 3-5 x 120 sq.mm |
| 207 | a) 3-5 x 70 sq.mm |
| 208 | b) 3-5 x 35 sq.mm |
| 209 | Laying of one number PVC insulated and PVC Sheathed /XLPE power cable of 1.1kV grade of following size direct in ground including excavation , sand cushioning, protective covering, and refilling the trench etc as required. |
| 210 | Above 35 sq. mm and upto 95 sq. mm |
| 211 | Above 95 sq. mm and upto 185 sq. mm |
| 212 | Laying and fixinf of one number PVC insulated and PVC Sheathed /XLPE power cable of 1.1kV grade of following size on wall / surface as required. |
| 213 | Upto 35 sq mm (clamped with 1mm thick saddle) |
| 214 | Supplying and making end termination with brass compression glands and copper lugs for following size ofPVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 215 | 3-5 x 120 sq.mm |
| 216 | 3-5 x 70 sq.mm |
| 217 | 3-5 x 35 sq.mm |
| 218 | Supplying, installation, Testing & Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 ,UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \"complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be asapproved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 219 | 8- 10W LED Downlghter (Round) |
| 220 | 12- 15W LED Downlghter (Round) |
| 221 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 18-22 Watt LED Batten |
| 222 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS:374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req |
| 223 | 1200mm, service value >_ 6.0 CM/Min/Watt, air delivery 210 CM/Min |
| 224 | 1400mm, service value >_ 6.0 CM/Min/Watt, air delivery 245 CM/Min |
| 225 | Supplying of 300 mm 900 RPM exhaust fan complete with louver with 3 core flexible wire as required. |
| 226 | Supplying and Fixing 02 Ton Split Air conditioner (100% copper ) with stabilizer of approved make compatible with AC and all complete necessary fittings required like outdoor unit stand etc. As per site requirenment and direction of engineer incharge. |
| 227 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required. |
| 228 | Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting ofall types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copperconductor, single core cable and earthing etc. as required. |
| 229 | Installtion of exhasut fan in the existing opening, including making good the damage, connection testiing and commissioning etc as requried Upto 450 mm sweep |
| 230 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 231 | SITC of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junctiontemperature shall not rise above 90°C). (System lumen efficacy ≥105 <120 lm/Watt)25 Watt |
| 232 | Supply installation, testing and commissioning of external post top lanternin cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. 4.5m high (3.5m above ground) 65mm dia GI pole as approved, adopting socket at top for fixture mentioned below, base plate 300x300x6mm and provision for mounting junction box etc.- 1 set |
| 233 | Earthing with G.I earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr longetc.with charoal or coke and salt as required. |
| 234 | Providing & fixing 25mm x 5mm GI Strip in 40mm dia GI pipe from earth elecrode including connections with GI nut, bolt, spring, washer excavation and re-fiiling etc. as required. |
| 235 | Providing & fixing 25mm x 5mm GI Strip on surface / recess for connections as required. |
| 236 | Providing & fixing of 6 SWG dia G.I wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. |
| 237 | SITC of microprocessor based intelligent addressable main fire alarmpanel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.Ten loop pannel |
| 238 | SITC of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. |
| 239 | SITC of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 240 | SITC of fault isolator complete with base as required |
| 241 | SITC of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required |
| 242 | SITC of addressable manual call point complete as required |
| 243 | SITC of addressable horn cum strobe complete as required |
| 244 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 245 | Supplying and fixing of following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.a) 1 or 2 Module 75 mm x 75 mm |
| 246 | Supplying and drawing following pair, 0.5.mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 247 | Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding plate etc .as required. |
| 248 | Telephone socket outlet |
| 249 | TV Antena socket outlet |
| 250 | Providing & fixing Data outlet one module for Data Points (RJ-45). As per site requirenment and direction of engineer incharge. |
| 251 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shieldewith fine tinned copper braid and protected with PVCsheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 252 | Supplying and fixing of the following sheet steel clad wall / recess mounting telephone tag block constructed from 14 SWG sheet steel finished with red oxide coating of two coats of paint with hinged gasketted powder coated door and complete. 5 Pair. As per site requirement and direction of engineer incharge.05 pairs |
| 253 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required 1 Run of cable |
| 254 | WATER COOLER. Double walled insulated body. The tank of water cooler to be made of 304 grade ss sheet. The unit to have 1nos tap. 80 LTRS capacity |
| 255 | Supply , Installtion , Testing and comissioningof following wall mounted rack with front sheet steel glass door, top & bottom cover with cable entry provision, fans , 2 cable managers , stationary shelf , 2 Nos of hardware pkts complete as required. 9U. As per site requirement and direction of engineer incharge.9 U |
| 256 | Supply , Installtion , Testing and comissioning of loaded jack/patch panels for LAN cable termination complete as required. 24 Port. As per site requirement and direction of engineer incharge.24 Port |
| 257 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges ,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 258 | 25 mm dia. |
| 259 | 50 mm dia. |
| 260 | 80mm dia |
| 261 | 100mm dia |
| 262 | 150mm dia |
| 263 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required :150 mm dia |
| 264 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 265 | 25 mm nominal bore |
| 266 | 50 mm nominal bore. |
| 267 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :150 mm dia. |
| 268 | Providing and fixing in position industrial type pressure gauges with gun metal / brass valves complete etc. as required |
| 269 | Providing,installation,testingandcommissioningof stainlesssteelY-strainerfabricatedoutof1.6mm thickstainlesssteel,Grade304,sheetwith3mmdia holes with stainless steel flange. 150mm dia |
| 270 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 271 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal |
| 272 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30m |
| 273 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal |
| 274 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun Metal |
| 275 | Providing and fixing doorwith frame for all internal fire hydrants fabricated from 20x20x3mm and40x20x3 mm aluminium hollow box sections mounted with 3 no. of 100 mm Aluminium butt hinge onAluminium angle frame of 45x45x5mm size with hold fasts fixed to wallwithP.C.C. (1:2:4) blocks 100x100x100 mm including 2 nos allen key lock for locking along with padlock arrangement& fully glazed with 4 mm thick float glass approved by local Fire Authority, powder coated fire red finish with \" fire hose\" written on front suitable to house 15 mm long two length of canvas hose with couplings, one no of branch pipe, one fire mans axe and two numbers of portable extinguishers, first aid fire hose and supports for hoses, branch pipes, Axe and hose reel. Size 2100x 900 mm complete as per approved design including necessary fixing arrangement for hoses & axe and branch pipe.) |
| 276 | Providing andfixinggunmetalfire brigade inlet head as per IS:904 Specification tested for 20 Kg/cm2 with 63 mm dia. instantaneous typeinlet and 100/150mm dia.. flangedoutlet with built-in check valve forfire brigade connection to under ground tanks and fire risers including companion flanges as portable \" E\" including nuts, bolts & washers etc. Two way |
| 277 | Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, dischargenozzle, suspension bracket, confirming to IS: 15683 finished externally with redenamelpaint andfixed towall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.) |
| 278 | Providing and fixing waterCO2(ISI marked) extinguishers includingall accessoriesas per IS specification with wall bracket with rawl plug Capacity 9 liters.(IS:15683). As per site requirement and direction of engineer incharge. |
| 279 | Providing and fixing of self illuminated / auto glow \"EXIT\" signs printed on photoluminescentsheet containing self illuminated base chemical, of appropriate size not less than 300 x 100 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site. |
| 280 | Supplying,installation,testingandcommissioningof electric driven terrace pumpconforming to IS 12469: 2019suitable forautomatic operationandconsistingoffollowing,completeinallrespects, as required: (Terrace Pump)(a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b)SuitableHPsquirellcageinductionmotorTEFCtype suitable for operation on 415 volts, 3 phase, 50 Hz, AC supplywithIP55classofprotectionforenclosure, horiziontalfootmountedtypewithClass-\"F\"insulation, conforming to IS-12615: 2018(c)M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d)Suitablecementconcretefoundationdulyplastered and with anti vibration pads.900 lpm at 35 m Head |
| 281 | Supplying, Installation, Testing & Commissioning offollowing capacity passengerMachine room less(MRL) lift with regenerative driveas per CPWDGeneral Specification for Electrical Works (Part-III Lift & Escalator) 2003,BIS Codes, NBC 2016 asamended upto date having provision for barrier free access as per Harmonised Guidelines & Standards forUniversal Accessibility in India - 2021 of MoHUA,serving different floors in the lift shaft as per detailedspecifications enclosed and as under including allother equipment and accessories complete as required:- (i) Speed-1 MPS (ii) Floors-5 (G+4) (iii) Travel -17 Meters (approx.) (iv) Stops & opening- 5 stops and 5 openings (v) Controller: A.C. variable voltage & variablefrequency (vi) Automatic rescue device (ARD) complete with drymaintenance free batteries as required. vii) Operation: Microprocessor based single automaticpush button/simplex selective collective/duplex collective selective with/without attendant (viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wiressystem (ix) Car Enclosure: Stainless steel scratch proof(Moon Rock/Honeycomb/ Hairline Finish) on all sidesand stainless steel decorative ceiling with fans (indirectthrow) and LED fitting. (x) The car flooring should be smooth and antiskidas approved by engineer-in-charge. (xi) Type of doors (a) Car: Power operated, centre opening horizontalsliding stainlesssteel scratch Rock/Honeycomb/ Hairline Finish)(b) Landing doors: stainless steel scratch proof . (xii) A hand rail not less that 600mm long at 900mmabove floor level to be fixed adjacent to control panelin the lift car. (xiii)Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at floor served by the elevator. (xiv)Closed loop Control System, protection againstpower fluctuation, self diagnostic control, Landingdoors 2 hours Fire rated, Overload detection andprotection, Overspeed Governer,(xvi)An appropriate technological support be provided(Through emergency messaging |services or alarms etc.) torespond to the emergency requirements of person withhearing impairment or deafness.(xvii) In case of failure of ARD or other electronicdevices, a provision of manual rescue be provided 13 passenger (884kg) |
| 282 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail