Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation of foundation in hard soil with all leads and lifts including dressing the sides and levelling the bed and depositing the excavated earth at places away from work site with all leads and lifts including cost of all labour and royalty etc. complete and as directed by the Engineer-in-charge. |
| 2 | Single under reamed pile foundation 375 mm dia and 10.0 metre long with RCC M20 using 12mm size black hard granite (Crusher broken) stone chips including cost of boring but excluding cost of M.S./Tor steel and labour charges for cutting, bending and binding of steel etc with all leads and lifts including cost of all labour and ,royalty etc. complete and as directed by the Engineer-in-charge. |
| 3 | Supplying, filling in foundation and plinth with sand including watering and ramming with cost, conveyance, royalties of sand with labour and required for the work etc. complete as per direction of the Engineer in charge. |
| 4 | Providing plain cement concrete ( 1:3:6 ) in foundations using 40 mm nominal size h.g. metal including watering and curing etc. complete as per direction of the Engineer in charge. |
| 5 | Fly ash bricks masonary in cement mortar (1:6) after immersing bricks for six hours in water before use in super structure using Fly Ash bricks of size (25 x 12 x 8 cm) having a crushing strength of not less than 75 Kg/Cm2 including splays cutting circular moulding chmfering and corbelling watering and curing etc complete including cost and conveyance of all materials and labour with required for the work with all taxes and royalities etc. complete in all respect or as directed by the Engineer-in-charge. |
| 6 | In Foundation |
| 7 | In Superstructure |
| 8 | In Superstructure (F.F) |
| 9 | In Superstructure (2nd Floor) |
| 10 | Fly ash bricks masonary in cement mortar (1:4) after immersing bricks for six hours in water before use in super structure using Fly Ash bricks of size (25 x 12 x 8 cm) having a crushing strength of not less than 75 Kg/Cm2 including splays cutting circular moulding chmfering and corbelling watering and curing etc complete including cost and conveyance of all materials and labour with required for the work with all taxes and royalities etc. complete in all respect or as directed by the Engineer-in-charge. |
| 11 | In Superstructure (F.F) |
| 12 | R.C.C. work of Grade- M 20 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position. |
| 13 | Pile Cap |
| 14 | Column & beam |
| 15 | Column & beam (F.F) |
| 16 | Column & beam (2nd Floor) |
| 17 | Plinth bend |
| 18 | Lintel, Window seal & Bed block |
| 19 | Lintel, Window seal & Bed block (F.F) |
| 20 | Lintel, Window seal & Bed block (2nd Floor) |
| 21 | Chhaja |
| 22 | Chhaja (F.F) |
| 23 | Chhaja (2nd Floor) |
| 24 | Roof Slab |
| 25 | Roof Slab (F.F) |
| 26 | Roof Slab (2nd Floor) |
| 27 | Staircase |
| 28 | Staircase (F.F) |
| 29 | Fins (F.F) |
| 30 | Fins (2nd Floor) |
| 31 | Supplying, fitting and placing uncoated HYSD bar reinforcement straightening, cutting, bending, placing in position HYSD and binding all complete. lifting and placing in position as per design complete including cost of bars , binding wires , including cost of all materials, labour, conveyance, loading and unloading,, royalties, sundries, tools and plants, etc. complete as per the direction of the Engineer-in-charge. (linear measurement will be taken and quantity will be calculated on standard weight for all heights)-Thermo Mechanically Treated bars as per direction of the Engineer in charge. |
| 32 | 1st Floor |
| 33 | 2nd Floor |
| 34 | 20 mm thick grading plaster ( 1:4 ) on roof slab including watering and curing with cost and conveyance of all materials and labour with required for the work with all taxes and royalities etc. complete in all respect in all floors or as directed by the Engineer-in-charge |
| 35 | 1st Floor |
| 36 | 2nd Floor |
| 37 | Supplying, fitting and fixing vetrifed tile in floors of size 600mm x 600 mm of approved make with application of polymer modified cement based water resistant adhesive bed of required thickness of 10 mm and filling joints with epoxy grout of approved quality etc complete including cost and conveyance of all materials and labour with required for the work with all taxes and royalities etc. complete in all respect or as directed by the Engineer-in-charge. |
| 38 | 1st Floor |
| 39 | 1st Floor |
| 40 | Fixing Vetrified tiles in dados skirting on 12 mm thick CP ( 1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles inclu rubbing and polishing etc complete including cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect or as directed by the Engineer-in-charge. |
| 41 | 1st Floor |
| 42 | 1st Floor |
| 43 | Fixing Antiskirting Ceremic tiles in floors treads on 25 mm thick bed of cement mortar ( 1:1) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including watering and curing with the cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect in all floors or as directed by the Engineer-in-charge |
| 44 | 1st Floor |
| 45 | Fixing Antiskirting Ceremic tiles in dados skirting on 12 mm thick CP ( 1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles inclu rubbing and polishing etc complete including watering and curing with the cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect in all floors or as directed by the Engineer-in-charge |
| 46 | 1st Floor |
| 47 | Fixing Kota tiles in floors treads on 25 mm thick bed of cement mortar ( 1:1) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of Kota tiles. etc complet including watering and curing with the cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect in all floors or as directed by the Engineer-in-charge |
| 48 | 1st Floor |
| 49 | Fixing Kota tiles in dados skirting on 12 mm thick CP ( 1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles inclu rubbing and polishing etc complet including watering and curing with the cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect in all floors or as directed by the Engineer-in-charge |
| 50 | 1st Floor |
| 51 | 25mm thick A.S. flooring with C.C (1:2:4) using 12mm size H.G. chips of approv quality etc including cost carrage T & P & punning etc complet including watering and curing with the cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect in all floors or as directed by the Engineer-in-charge |
| 52 | 12mm thick cement plaster (1:6) over Brick / stone massonary finished smooth including watering and curing with cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect in all floors or as directed by the Engineer-in-charge |
| 53 | 1st Floor |
| 54 | 2nd Floor |
| 55 | 16mm thick cement plaster (1:6) over Brick / stone massonary finished smooth including watering and curing with cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect in all floors or as directed by the Engineer-in-charge |
| 56 | 1st Floor |
| 57 | 2nd Floor |
| 58 | 20mm thick cement plaster (1:6) over Brick / stone massonary finished smooth including watering and curing with cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect in all floors or as directed by the Engineer-in-charge |
| 59 | Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures with cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect in all floors or as directed by the Engineer-in-charge |
| 60 | 1st Floor |
| 61 | Providing, fitting and fixing of F.R.P. doors with frame of approved design and colour including labour with T&P required for the work with all taxes and royalities etc. complete in all respect in all floors or as directed by the Engineer-in-charge |
| 62 | 1st Floor |
| 63 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. including cost of materials all taxes labour t&P etc complete as per direction of EIC. |
| 64 | 1st Floor |
| 65 | 2nd Floor |
| 66 | Providing and fixing of fixed partly fixed, partly top hung and partly louvered windows of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per (IS-513 of 0.6 mm thick \"D\" quality galvanized as per IS-277 with zinc of 120 gm/sqm) with paint specification being with primer of 5-7 microns and finished with primer of 5-7 microns and finished paint with ployster paint of 12-16 microns along with the alkyd backer at the back of 5-7 microns and the sizes of outer frame being of 46 x 52 mm and with all vertical and horizontal mulions are of 46 x 70 mm and fixed beadings are of 18 x 40mm top hung shutter should be of 46 x 46 mm accessories/ gaskets are to be used as per manufacturer\"s supply and specification like handle being made of high grade aluminium powder coated and with nylon receiver and gasket will be made of EPDM. All corner backets are to be made of CRCA with zinc phosphating. The mullion caps and louvered-clips should be of glass filled nylon. The sections are to be cut to length, mitre joined with corner bracket and frames are fixed to conctere or masonry wall by means of self expanding screwa and glass to be used of 5mm reflective with all taxes complete. |
| 67 | 1st Floor |
| 68 | Supplying iron shutter M.S. panalled door single leaf with M.S. frame and M.S. panalled window double leaf with M.S. frame and grill etc complete including cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect or as directed by the Engineer-in-charge. |
| 69 | 1st Floor |
| 70 | 2nd Floor |
| 71 | Fitting, fixing iron shutter M.S. panalled door with M.S. frame and M.S. panalled window with M.S. frame and grill in position etc including fixing in cement concrete CC (1:3:6) with 12mm to 20mm hard stone chips or in cement morter (1:3) including all cost of materials and as per the direction of the Engineer-in-charge. |
| 72 | 1st Floor |
| 73 | 2nd Floor |
| 74 | Supplying fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of sixe 32mm x 32mm x 2mm @ 0.90mtr C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in e rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour T&P etc required for the complete in all respect and as per the direction of the Engineer-in-charge. |
| 75 | 1st Floor |
| 76 | Providing, fitting and fixing of false ceilling with aluminium anodised T Section No 3215 with 2\"-00\"\" center to center, L section No 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and PVC plug and the aluminium grid 2\"-0\" x 2\"-0\"\" suspended from ceiling etc complete including all cost of materials and as per the direction of the Engineer-in-charge. |
| 77 | 1st Floor |
| 78 | Finishing wall surface of walls with Acrylic wall putty ( water based ) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging, charges with cost, conveyance, royalities and taxes of all materials and labour with T&P require for the work etc. complete in all respect in all floors or as directed by the Engineer-in-charge. |
| 79 | 1st Floor |
| 80 | 2nd Floor |
| 81 | Priming 1 coat with any appproved Primer of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging, charges with cost, conveyance, royalities and taxes of all materials and labour with T&P require for the work etc. complete in all respect in all floors or as directed by the Engineer-in-charge |
| 82 | 1st Floor |
| 83 | 2nd Floor |
| 84 | Distempering two coats to the wall surface with any approved paint over a coat of chalk wash including cost of distemper etc. conveyance, royalities and taxes of all materials and labour with T&P require for the work etc. complete in all respect in all floors or as directed by the Engineer-in-charge. |
| 85 | 1st Floor |
| 86 | 2nd Floor |
| 87 | Wall painting two coats with Acrylic Emulsion paint (weather seal coat) of approved shade on new work to give an even shade including cost, conveyance and taxes of all materials and labour with T&P required for the work etc complete in all respect in all floors or as directed by the Engineer-in-charge |
| 88 | 1st Floor |
| 89 | 2nd Floor |
| 90 | Painting 2 (Two) coats with any approved enamel paint over a coat of priming to new wood work and iron work including cost of the primer and paint sand papering polishing the surface with cost conveyance and taxes of all materials and labour with T&P required for the work etc complete in all respect in all floors or as directed by the Engineer-in-charge. |
| 91 | 1st Floor |
| 92 | 2nd Floor |
| 93 | P.H Work |
| 94 | Supplying all materials, labour T&P and fixing Ceramic Tiles in floors on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per specification and direction of Engineer-in-charge.[Gr.Floor] |
| 95 | First Floor |
| 96 | Supplying all materials, labour T&P and fixing porcelain glazed tiles in dados skirting, on 12mm thick C.P. (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of Engineer-in-Charge [Gr.Floor] |
| 97 | First Floor |
| 98 | Supplying all materials, labour, T&P and providing marble slab in urinal partition wall including cutting grooves in walls and making good the damages including watering curing etc all complete as per specification and direction of the E.I.C.-Marble slab in urinal partition wall |
| 99 | Factory made FRP(alternately called GRP) door frame of size 75mmx100mm fabricated using E-glass Chopped Strand Mat (CSM) U.V stabilised Inopthalic Gelcoat and impregnated with Inopthalic resin. The thickness of the GRP skins shall not be less than 2.00mm. The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The GRP frame shall be provided with wooden reinforcement on six locations for high screw holding capacity for for fixing metallic hold fast and shall be consolidated by filling with medium density foam/plaster of paris with fibre reinforcement, Six numbers of 260mm x 25mm x 5mm size \"S\" shaped M.S flat hold fast shall be provided with the frame. The material and process for manufacturing the door frames shall conform to RV-TIFAC composites Design Centre\"s standards and specifications. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the E.I.C |
| 100 | Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gel coat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic polyester resin. The thickness of the skins shall not be less than 1.50mm Expanded Polystyrene(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reinforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre\"s standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/Light grey/ Mahogany/Teak wood or any other colour using high quality pigments. Three heavy weight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 101 | Supplying all materials, labour, T&P and fixing water closet, squatting pan (Indian type W.C. pan/Orissa Pattern Squatting pan) duly embedded in c.c.(1:5:10) using 4 cm h.g. Metal all complete as per direction of E.I.C.- 580x440mm Orissa Pan.(Cera/ Parry ware/ Hindware) |
| 102 | Supplying all materials, labour T&P and fixing Wash Down Water Closet(European type W.C. pan) with Integral ‘S’ ’ trap to the floor with wooden plug and C.P.screws including jointing the trap with soil pipe in C.M.(1:1) etc. all complete as per specification & direction of E.I.C--One Piece E.W.C. with Cistern Complete Set (Cerra/ Parry ware/ Hindware) |
| 103 | Supplying all materials, labour T&P and fixing Wash Down Water Closet(European type W.C. pan) with Integral ‘S’ or ‘P’ trap to the floor with wooden plug and C.P.screws including jointing the trap with soil pipe in C.M.(1:1) etc. all complete as per specification & direction of E.I.C-- E.W.C. with ‘S’ trap Plain(Cera/ Parry ware/ Hindware) |
| 104 | Supplying all materials, labour, T&P fitting and fixing Plastic Seat and cover for E.W.C. with chromium plated brass hinges and rubber buffers all complete as perr specification and direction of E.I.C.(Neycer/Cera/ Parrywear/ Hindware) |
| 105 | Supplying all materials, labour T&P and fitting & fixing SWR ventilating pipes and fittings of the following O.D conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method as per manufacturer’s specification, testing, e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C.- 110 mm dia PVC SWR Pipes |
| 106 | 110 mm dia PVC SWR P’ Trap |
| 107 | 110 mm dia PVC SWR DoorTee |
| 108 | 110 mm dia PVC SWR Door Cross Tee |
| 109 | 110 mm dia PVC SWR Door Bend |
| 110 | 110 mm dia PVC SWR Plain Bend |
| 111 | 110 mm dia PVC SWR Plain Tee |
| 112 | 110 mm dia PVC SWR Offset |
| 113 | 110 mm dia PVC SWR Cowl |
| 114 | 125 mm dia C.P.grating |
| 115 | 75 mm dia PVC SWR Pipes |
| 116 | 75 mm dia PVC SWR Plain Bend |
| 117 | 75 mm dia PVC SWR Door Bend |
| 118 | 75 mm dia PVC SWR Plain Tee |
| 119 | 75 mm dia PVC SWR Door Tee |
| 120 | 110mm dia PVC SWR Nahani trap without Jally |
| 121 | 110x75 mm dia PVC SWR R/S |
| 122 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with C.I/M.S brackets painted white including holes in walls and making good the damages etc. all complete as per P.H specification and direction of E.I.C.- 550mm x 400mm WHB with all Fittings with C.P. Waste, PVC Waste Pipe & Connection Pipe. (Cera/ Parry ware/ Hindware) |
| 123 | Supplying all materials, labour T&P and fixing pedestal for wash basin complete recessed at the back for the reception of pipe and fitting etc. all complete as per specification and direction of E.I.C. (Parrywear/Cera/Hindware) |
| 124 | Supplying all materials, labour T&P and fixing mirror of superior glass mounted on 6mm thick plywood sheet and fixed to wooden plugs with C.P screws and washers complete as per P.H specification and direction of E.I.C.- 600mm x 450mm B.E. Mirror (fixed type) |
| 125 | Supplying all materials, labour T&P and fixing standard size C.P. towel rail / ring complete with c.p. brass brackets fixed to wooden plugs with c.p screws as per P.H specification and direction of E.I.C.- 20 mm x 600 mm long C.P Towel rail |
| 126 | C.P. Towel Ring (St.) |
| 127 | Supplying all , labour T&P and fitting, fixing of standard size Glass shelf with CP brass bracket and guard rails complete fixed to wooden plugs with CP screw as per specification and direction of E.I.C- 450x125mm size Plate Acrylic Shelf |
| 128 | Supplying all materials, labour T&P and fixing standard size C.P. soap holder complete with c.p brass brackets fixed to wooden plugs with cp screws as per PH specification and direction of E.I.C- C.P.Soap Holder. |
| 129 | Supplying all materials, labour T&P and fixing Half Stall Large Wall urinal including the connecting the urinal with waste pipe by means of white lead list with chopped hemp etc. all complete as per direction of E.I.C.-- Half Stall Large Wall urinal (standing Urinal) including 32mm dia PVC Waste Pipe with brass coupling nut & 15mm dia PVC inlet connection Pipe [CerraParrywear/Hindware] |
| 130 | Supplying all materials, labour, T&P and fixing glazed earthen ware Squatting Plate size 450x350 mm with integral longitudinal flushing pipe including embedding the plate in 25mm thick cement mortar (1:8) laid over PCC (1;5:10) using 40mm size metal etc. all complete as per specification and direction fo the EIC-Squatting Urinal [CerraParrywear/Hindware] |
| 131 | Supplying all materials, labour T&P and cutting holes through brick/stone masonary walls for taking PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of E.I.C. - 250 mm thick wall |
| 132 | Earth work in all kinds of soil in excavation of foundation trenches within 50 m initial lead including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding o.30 in depth and as per direction of E.I.C .- Initial lift up to 1.50m |
| 133 | 2nd depth upt 3.00 mtr |
| 134 | Supplying all materials, labour T&P and filling in F&P with river sand well watered and rammed including conveyance of all materials to worksite payment of royalty, taxes etc. all complete as per direction of E.I.C. |
| 135 | Supplying all materials, labour T&P and providing c.c (1:3:6) using 4cm h.g. metal including watering, curing, coveyance of all materials to worksite payment of royalty, taxes etc. all complete as per specification and direction of E.I.C. |
| 136 | Supplying all materials, labour T&P and providing c.c (1:1.5:3) using 12 mm h.g. chips including watering, curing, coveyance of all materials to worksite payment of royalty, taxes etc. all complete as per specification and direction of E.I.C. |
| 137 | In1st Floor |
| 138 | Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks 25cmx12cmx8cm size having cs. not less than 75kg / cm2 with dimensional tolerance ± 8% in including watering,curing conveyance of all materials to worksite, payment of royalty taxes etc. all complete as per specification and direction of EIC. -- In Foundation & Plinth in CM (1:4) |
| 139 | Supplying all materials, labour, T &P and providing C.C (1:1.5:3 ) using 12mm h.g. chips for R.C.C. works including hoisting, laying, watering, curing, conveyance of all materials to worksite, curing, conveyance of all materials to worksite, payment of royalty, taxes etc, all complete as per specification and direction of E.I.C. |
| 140 | Supplying all materials, labour, T&P and providing M.S. reinforcement for R.C.C. works including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite etc. complete as per directio n of E.I.C. |
| 141 | Supplying all materials, labour, T&P and providing rigid & smooth centering & shuttering for R.C.C.works including false work and dismantling them after casting including conveyance of all material, to worksite, payment of royalty, taxes etc. all complete as per direction of E..I.C.- R.C.C.Slab |
| 142 | Supplying all materials, labour, T&P and providing cement plaster on brick/stone work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of E.I.C.-- 12mm thick C.P with C.M. (1:4) |
| 143 | 20mm thick C.P with C.M. (1:3) |
| 144 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per specification and direction of E.I.C. |
| 145 | Supplying all materials, labour, T&P and providing cement flush pointing to brick masonary (1:3) including watering, curing conveyance of all materials to work site, payment of royality, taxes etc. all complete as per direction of E.I.C. |
| 146 | Supplying all labour, materials T&P and fixing of R.C.C. Baffle wall pre-cast with C.C. (1:1.5:3) using 12 mm b.h.g. chips and fitted to septic tank as per P.H. Specification and direction of E.I.C. |
| 147 | Supplying all materials, labour, T&P and providing PVC Tee inside the septic tank including cutting holes and duly embeded in P.C.C(1:3:6) using 12mm size HG chips fitted and fixed in position and mending good the damages etc all complete as per P.H specification and direction of the E.I.C.- 110mm x110mm x110mm PVC Tee |
| 148 | 160mm x160mm x160mm PVC Tee |
| 149 | Supplying all materials, labour, T&P and providing pre-cast R.C.C. Manhole cover with C.C. ( 1:1.5:3) of 12 MM h. g. chips including conveyance of all materials to site after payment of royality and taxes etc.all complete as per PH.Specification and direction of Engineer-in-charge. |
| 150 | Filling F&P with excavated materials, including watering and ramming as per direction of E.I.C. |
| 151 | Supplying all materials, labour T&P and costructing gully trap chamber of the following inside size with 8cm thick R.C.C. precast cover slab in c.c. (1:1 1.5:3) using 12 mm size h.g. chips foundation concrete (1:3:6) using 40 mm size h.g. metal on bed and arround trap Fly Ash brick work in c.m. (1:6) in F&P and inside 12mm thick c.p (1:3) finished with a floating coat of neat cement including fixing 100mm size H.C.I gully trap and grating etc. all complete as per approved drawing, specification and direction of E.I.C.- Inside size 250mm x 250mm gully trap Chamber |
| 152 | Supplying all materials, labour T&P and constructing Inspection chamber of the following sizes with c.c (1:3:6) using 40mm size h.g. metal on bed, Ist class Fly Ash brickwork in c.m (1:6), moulding and shaping the channel inside and benching with c.c. (1:11/2:3) using 12mm size h.g. chips 12mm thick c.p. (1:3) with punning to inside cement flush pointing (1:3) to outside R.C.C. cover slab in c.c. (1:11/2:3) using 12 mm size h.g. chips with R.C.C. m.h. cover, e.w. in excavation in all kinds of soil and refilling the cavity arround the chamber including watering, curing, conveyance of all materials to site payment of royalty, taxes etc. all complete as per approved specification and direction of the E.I.C.-- Inside size 760mm x 760mm x 460mm I.C. |
| 153 | Supplying all materials, labour T&P and constructing man hole chamber of the following sizes with c.c. ( 1:3:6) using 40 mm size h.g. metal on bed Ist class Fly Ash brick work in c.m. (1:6) moulding and shaping the channel inside and benching with c.c (1:11/2:3) using 12mm size h.g. chips, 12 mm thick c.p (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C. cover slab in c.c (1:11/23) using 12 mm size h.g. chips with R.C.C m.h. cover, e.w in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to site payment of royalty, taxes etc. all complete as per approved specification and direction of the E.I.C.- Inside size 910mm x 910 mm x 910 mm |
| 154 | Supplying all materials, labour, T&P and laying 110 mm dia SWR pipes of the following O.D conforming to IS No. 13592 and aligning to requisite gradient inside the trench encasing all round of the pipe with c.c (1:3:6) using 4 CM size h.g. metal and CC(1:3:6) with 4CM size h.g. metal in the bed of the trench including lowering the pipes to the bed of the trench, earth excavation in trenches in all kinds of soil, refilling the same in layer of 0.3 mtrs with watering and ramming, removing of surplus earth, testing of sewerage line including use of T&P as per PH Specification and direction of E.I.C.- 110 mm dia PVC SWR Pipe Sewerage line with all round encasing (conforming to IS No. 13592) |
| 155 | 160 mm dia PVC SWR Pipe Sewerage line with all round encasing (conforming to IS No. 13592) |
| 156 | Supplying all materials, labour T&P and constructing soak way pit of the following sizes with dry brick walling form bottom up to invert of inlet pipe and 1st class Fly Ash brickwork in c.m(1:6) for the remaining height at top, 12 mm thick c.p(1:4) inside and outside over masonary brickwork gravel packing in the rear of well steining R.C.C. cover slab in c.c (1:11/2:3) using 12mm size h.g. chips fitted with iron lifting handles including e.w. in open well excavation in stoney earth and refilling the cavity around the pit & painting the iron works, watering , curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved drawing, specification and direction of E.I.C.-1.20mtrs.dia x 2.0mtr.deep soak way pit |
| 157 | Supplying all materials, labour, T&P and fixing rotational moulded polyethylene cylindrical vertical waterstorage tank confirming to IS 12701- 1996 including cutting hole through the tank and fixing MS tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting the tank and placing the tank to the required position including all complete as per specification and direction of EIC.(including cost of FG Over Head Tank) ]- 2000 Ltrs. Capacity F.G.Over Head Tank. (on roof of 1st floor) |
| 158 | Supplying all materials, labour, T&P and Construction of masonary stagging with providing 1st class Fly Ash brick work in c.m, (1:6) of 0.46m. height in staging and in circular protection wall to support the tank in roof of ground floor using 25cm x 12cm x 8cm size Fly Ash bricks having crushing strength not less than 75 kg/cm2 12mm thick c.p.(1:4) over brick work, R.C.C. Slab of size 1.64mtr xl.64mtr x0.l0mtr thick, R.C.C. beam of size 0.25m x 0.30m and 2.60m average length in c.c.(1:1.5:3) using 12mm size h.g. chips including centering and shuttering, watering, curing conveyance of all materials to work site etc. all complete as per specification and direction of E.I.C - For 2000 Ltr. Capacity Over Head Tank(on roof of 1st floor) |
| 159 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor PVC Pipes conforming to ASTM-D-1785/89(sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor testing all complete as per specification and direction of E.I.C - 20 mm dia C-PVC Pipe [Internal] |
| 160 | 25 mm dia C-PVC Pipe [Internal] |
| 161 | 25 mm dia PVC (ASTM) Pipe [External] |
| 162 | 32 mm dia PVC (ASTM) Pipe [External] |
| 163 | 40 mm dia PVC (ASTM) Pipe [External] |
| 164 | 32mm dia HDPE Pipe [Inside Tw] |
| 165 | 32mm dia HDPE Pipe [External Including Earth Work] |
| 166 | 20mm dia HDPE Pipe [External] |
| 167 | Supplying all materials, labour, T&P and cutting holes through brick/stone masonary works including making good the damages in c.m. (1:4) for taking P.V.C. pipes & fittings etc. all complete as per P.H. specification and direction of E.I.C. |
| 168 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C. |
| 169 | Supplying all materials, labour, T&P and fitting & fixing brass /C.P. fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C.- 15 mm dia C .P S.B. Bib Cock [Jaquar] |
| 170 | 15 mm dia C .P L.B. Bib Cock[Jaquar] |
| 171 | 15 mm dia C .P Angle Stop Cock[Jaquar] |
| 172 | 20mm dia C .P Conceal Stop Cock[Jaquar] |
| 173 | 15 mm dia C .P Pillar Cock Swan Neck [Jaquar] |
| 174 | 15 mm dia C .P Two Way Bib Cock [Jaquar] |
| 175 | 15 mm dia C .P Health Facuet[Jaquar] |
| 176 | 15 mm dia C .P Extension Piece |
| 177 | 25 mm dia PVC Ball Valve (Metal Ball) [Good Quality] |
| 178 | 32 mm dia PVC Ball Valve (Metal Ball) [Good Quality] |
| 179 | 40 mm dia PVC Ball Valve (Metal Ball) [Good Quality] |
| 180 | Supplying all materials, labour, T&P and fitting and fixing C.P. shower with 15 mm or 20 mm inlet with C. P. shower arm including polishing all complete as per P.H. specification and direction of E.I.C. |
| 181 | Supplying all materials, labour T&P and fitting & fixing 10 Litres capacity low level cistern with a pair of cast iron of m.s. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float, c.p. brass handle, unions and couplings for connection with inlet, outlet and overflow pipe. 32 mm C.P flush bend 15mm PVC inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting inlet pipe with supply main etc. all complete as per specification and direction of E.I.C (Cera/ Parry ware/ Hindware) |
| 182 | Sinking of 125x100mm dia tube well through Hand boring Method Supplying all materials, labour, T&P and setting up boring equipments including irrection of suitable stagging for installation of the required size of tube-well. Dismantling & removing the same after completion of the work including transportation of boring equipments clearing & leveling the site, excavation of mud pit channels etc., leveling of site all complete as per direction of E.I.C(Labour) |
| 183 | Supplying all labour, T&P & transportation of boring pipes, top casing, grouping pipes, PVC pipes and fitting, PVC well screens, cement, betonite etc. including loading and unloading etc. complete as per direction of the E.I.C.(Labour) |
| 184 | Supplying all labour, T&P and drilling pilot bore not less than 102mm dia without casing pipes in all kinds of soil and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments extra sockets etc.and withdrawing the boring pipes washing & keeping the bore clear for logging if required all complete as per the direction of EIC-- Pilot bore 100mm dia (00 mtr. to 360 mtr.) |
| 185 | Supplying all labour, T&P & reaming the pilot bore to the following sizes and depths without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc. all complete as per direction of E.I.C. -100 mm ot 150 mm dia( 00 mtr to 360 mtr) |
| 186 | 150 mm to 200 mm dia( 00 mtr to 360 mtr) |
| 187 | 200 mm to 250 mm dia( 00 mtr to 360 mtr) |
| 188 | Supplying all labour, Tools and plant and lowering the 300mm dia top casing pipe into position and removing the same after use as per the direction of Engineer-in-charge. |
| 189 | Supplying all labour, T&P and jointing materials and lowering the PVC casing pipes fitting and well screens in position including fitting of centralizer cutter plugs and washing the bore as per the direction of E.I.C.(Including cost of Materials) 125 mm dia PVC Pipe (Schedule-80) |
| 190 | 100 mm dia PVC Pipe (Schedule-80) |
| 191 | 100 mm dia PVC strainer |
| 192 | 125x100 mm dia PVC R/S |
| 193 | 100 mm dia C.I. Plug Cutter |
| 194 | Lowering of 125mm/100mm dia PVC Pipe |
| 195 | Supplying all labour, T & P and packing the bore with washed gravel ( size-P-6) around the pipes in good quality including cost of gravel etc. all complete as per direction of Engineer-in-Charge- |
| 196 | Cost of Gravel |
| 197 | Supplying all labour, T&P materials and providing sanitary sealing by cement slurry grouting around the uppermost 3.00 mtrs. of 125 mm dia PVC casing pipe . including cost of cement all complete as per direction of E.I.C (including cost of 2 bags of Cement) |
| 198 | Cleaning the developing the tube well using compressor continuously to get clear and adequate discharge from the tube well including the supply and use of all necessary equipment and labour as per direction of E.I.C(Labour Charges) |
| 199 | Supplying all labour, T&P and materials for fitting and fixing of India Mark-II Deep well Hand Pump with cast Iron cylinder, 12mm/16mm dia B.S. Connecting rod, 32mm dia G.I.Pipe of required lengths with supply of extra socket of approved make all complete including carriage, coveyance as per direction of Engineer-in-charge. |
| 200 | Supplying all labour, T&P and materials for Construction of Masonary Platform for India Mark-II Hand Pump as per I.S. Specification of 1.85 mtr Outside with Cement Concrete (1:2:4) with 12mm size hard granite C.B. chips etc. all complete including 760mmx760mmx400mm deep cement concrete embeded around the bore well pipe as per direction of Engineer-in-Charge. |
| 201 | Supplying all materials, labour, T&P and construction of 100mm wide waste water drain for India Mark-II Hand Pump platform as per UNICEF design and specification with C.C (1:2;4) using 12mm size hard granite crusher broken chips etc. all complete as per direction of Engineer-in-Charge. |
| 202 | Supplying of ISI Mark 1.00 HP Single Phase Vertical Submersible Pump Set with Discharge of 1800-2200 liter/hour and a head of 45-60 mtr of reputed make like KSB/Texmo & Equivalent including all cost, conveyance and taxes etc. all complete as per direction of Engineer-in-charage. |
| 203 | Supplying all labour, T&P and fitting and fixing of 1.00 HP Single phase vertical Submersible Pump Set with commissioning and testing, Electrification etc. all complete as per direction of EIC |
| 204 | Supplying and fitting and fixing of ISI Mark DOL Starter of reputed make like BCH or Equivalent for 1.00 HP Single Phase Submersible Pump including all cost, conveyance and taxes etc. all complete as per direction of Engineer-in-charge. |
| 205 | Supplying and fitting and fixing of three core flat cable (2.5mm2) of ISI Make of reputed company line BCH/Finolex or Equivalent and connecting the pump and starter including all cost, conveyance and taxes etc. all complete as per direction of Engineer-in-charge. |
| 206 | Supplying and fitting & fixing of Plastic rope, M.S. Well Cover, M.S. Clamp, Stainless Steel Short piece, Bend & Socket including all const, conveyance and taxes etc. all complete as per direction of engineer-in-charge. |
| 207 | Supplying all materials, labour, T&P and providing fitting and fixing Aquaguard Pure chill 120 PSS RO+UV+CuZn, Approximate external dimention (WxDxH) 750x570x1350, Opreating Power supply-170-260V AC 1 ph , Running Current in AMPs (Maxx)-4.5 ±10%, Power in Watt (Max) -700 ± 10%, Waer storage tank capacity-120 liters, Capacity with comfort label water outlet tempertaure at 170 Liters, Compressor make Emerson KCE 444/Equivalent, Regrigerant HFC R 134-a, Thermal Insulation for Storage tank-PUF, No of faucets-03, No, of Cold waer faucet-02, No. of Stages for filter cum Purifier-07, RO Membrance rating-4 No.x80 GPD or equivalent, Permeate (Purified Water) Production capacity -50 LPH, % of purified water recovery-25%, % Rejection of DS -90% Approx. Storage tank material-SS 304, Outer body maerial-Front SS 304, Type of product construction-Concealed, Type of Installation-Indoor, Weight-85KG etc. all complete as per direction of Engineer-in-charge. |
| 208 | Electrical |
| 209 | Recessed wiring to light point with 1.5 sq.mm FR PVC insulatedsingle core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front Modular base & cover of suitable size , MS box with 1 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels /HPL/ V Guard ) |
| 210 | Group A |
| 211 | Group B |
| 212 | Group C |
| 213 | Recessed wiring to Fan Point in... |
| 214 | Group B |
| 215 | Recessed wiring to Call bell Point in... |
| 216 | Group C |
| 217 | Recessed wiring to Exhaust Fan Point in….. |
| 218 | Group C |
| 219 | S/F of fan hook \"S\" type made of 16 mm MS rod for fixing in the Existing RCC Roof. |
| 220 | S/F of Angle holder replacing Ceilling Rose |
| 221 | Swich Boards |
| 222 | S/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board |
| 223 | S/F of extension board of 6 modular Metal box with modular base & cover in recess including providing and fixing of 2 nos of 3pin 5/6amp modular socket out let & 2 nos of 5/6 amp piano type modular switch, connection, painting etc as required. (Make of Switch & Socket: Anchor / Cona/ Greatwhite/ Havells/ HPL/ Preeti) |
| 224 | S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required (Make of Switch & Socket: Anchor / Cona/ Greatwhite/ Havells/ HPL/ Preeti) |
| 225 | S/F of Power point with 4 modular & 2 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket & Mini DP MCB, connection, painting etc as required for AC. (Make of Switch & Socket: Anchor / Cona/ Greatwhite/ Havells/ HPL/ Preeti) |
| 226 | S/F of computer board consisting of 3 nos of 5amp modular plug and modular switch & 1 no of Mini MCB complete with wiring on 12 modular M.S. box with modular cover. (Make of Switch & Socket: Anchor / Cona/ Greatwhite/ Havells/ HPL/ Preeti) |
| 227 | S/F of 1 no of 5 pin 15/16 amp. Socket , 1 no of switch & 1 no of 15/16A top with modular mini MCB, in 6 modular box with cover with connection, painting etc as required for Inverter connection. (Make : Anchor / Cona/ Greatwhite/ Havells/ Legrand/ L&T) |
| 228 | S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required. |
| 229 | 2 Modular box with base & cover |
| 230 | 6 Modular box with base & cover |
| 231 | 8 Modular box with base & cover |
| 232 | 12 Modular box with base & cover |
| 233 | Sub-Main |
| 234 | Wiring for circuit / sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire: Finolex/ L&T / Anchor / Havels /HPL / V Guard/ KEI/ Greatwhite/ Polycab) |
| 235 | 2x1.5+1x1.5 (1.8.1) |
| 236 | 2x2.5+1x1.5 (1.8.2) |
| 237 | 2x4+1x1.5 (1.8.3) |
| 238 | 4x6+2x2.5(1:8:10) |
| 239 | Inverter wiring (1x1.5smm) Copper wire (1.19.1) |
| 240 | Circuit Breakers |
| 241 | S/F of \"B/C/D\" series SP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP) (2.6.1) (Make : Anchor / Cona/ Greatwhite/ Havells/ Legrand/ L&T) |
| 242 | S/F of \"B/C/D\" series DP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the 2 Way double door MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required (2.6.2a)+(2.3.1b) (Make : Anchor / Cona/ Greatwhite/ Havells/ Legrand/ L&T) |
| 243 | S/F of \"B/C/D\" series TPN MCB of 63A amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box(2.6.4) (Make : Anchor / Cona/ Greatwhite/ Havells/ Legrand/ L&T) |
| 244 | Supply, Installation testing & commissioning of Main Switches (IS13940 part 3/1993) of following coopacity on existing surface/wall mounting & complete with H.R.C fuse links, inter connections earthing etc as required as per direction of Engineer Incharge (Make-Seimens/HPL/Anchor/L&T /Havels/C&S/R. K.) |
| 245 | S/F of MCB 6 way Single door (2.3.1(a) + 2.3.1(b)) |
| 246 | Main switches |
| 247 | Supply, Installation testing & commissioning of Main Switches (IS13940 part 3/1993) of following coopacity on existing surface/wall mounting & complete with H.R.C fuse links, inter connections earthing etc as required as per direction of Engineer Incharge (Make-Seimens/HPL/Anchor/L&T /Havels/C&S/R. K.) |
| 248 | S/F of 63A. ICTPN main switch (2.15.3) |
| 249 | Earthing |
| 250 | S/F of G.I.Earth Plate Earthing 600 mm x600mmx6mm with Salt & Charcoal for Earth electrode (3:4)+(3.6) |
| 251 | S/L of 25mm x 6mm G.I. earth strip in ground(3:10) |
| 252 | Fittings |
| 253 | Providing & fixing plain 16/0.2mm twin twisted flexible, FR PVC insulated copper cable in polythene sleeve or conduit of suitable size on the floor/wall or side of the table/door etc as required.(1.31) |
| 254 | Supply and fixing of 225mm Exhust fan with all accessories and connections (Make:Usha-Aero Clean Plus DBB/Crompton- Trans Air 12\" reversiable /Havells-Venti Air DS (HS)/Anchor- Anmol delux R/ Orient-Power Flow DBB/ Pollycab -Fresh on DBB ) |
| 255 | S/F of Call bell/Buzzer(Ding dong type) ISI marked suitable for DC/AC single phase 230 volts complete as required. (1.30) |
| 256 | S/F of 18-25Watt L.E.D Tube light fitting with all accessories and connections ( Make- Crompton/ HPL/ Polycab/ Havells/ / Panasonic/ RR/Crompton ) |
| 257 | SITC of 1200mm Sweep BLDC Ceiling Fan with Aluminium Blades having watage not more than 28 watt & Air Deleivery ≥ 215m3/min. (Replacement warranty will be 4 years) (Make:Usha-Techinix /Crompton- Energion Groove/Havells-Efficiencia Neo) |
| 258 | Supply and fixing of 60 Watt Single LED Street Light Fitting with LED & Electronic driver with all accessories and connections (Make- Crompton/ Phillips/ HPL/ Polycab/ Havells/ Panasonic/ RR/ Orient ) |
| 259 | S/F of 10w Watt LED Bulb (Make- Crompton/ Phillips/ Havells/ Panasonic) |
| 260 | S/F of1.5T 3Star ,Inverter model split type AC Machine, (Make-Carrier / Daikin/ LG/ Mitsubishi/O-General/Hitachi/BLUE STAR |
| 261 | S/F of 5KVA Automatic Voltage Stabilizer(110-300V), (Make-Microtech/V-Guard/ Shakti) |
| 262 | Cables |
| 263 | Provision of Armoured cable size 4x10sqmm (38) Make: Gloster/ KEI/ Finolex/ Anchor/ Havells/ V-Guard/ HPL/ L&T/ Greatwhite/ Pollycab) |
| 264 | Provision of Armoured cable size 3 1/2 x 35sqmm (25) Make: Gloster/ KEI/ Finolex/ Anchor/ Havells/ V-Guard/ HPL/ L&T/ Greatwhite/ Pollycab) |
| 265 | Laying of MV cable above 25sqmm to 120 sqmm in ground (5.1.2) |
| 266 | Laying of MV cable above 25sqmm to 120 sqmm on surface (Horizontally)(5.5.2) |
| 267 | S/M of end termination of LV/MV cable size 3 1/2 x35 sqmm (5.8.21) |
| 268 | Panels |
| 269 | Supply & fixing of 100 A TPN Panel board 1. 100A MCCB (Make- Legrand/Seimens/L&T/C&S/) & 100A kitkat & bus bar2. 32 A TPN MCB (Make- Legrand/Seimens/L&T/C&S/)- 2nos 3. 32A DP MCB (Make- Legrand/Seimens/L&T/C&S/)- 5 nos 4. 100 A 4P Manual changeover (Make- Legrand/Seimens/L&T/C&S/)- 1nos5. Digital Volt meter & Ameter three phase 6. All accesories & Connection (Rating & Danger borad) |
| 270 | Other items |
| 271 | S/F of 40mm HDPE Pipe for laying of cable & protection Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail