Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (unreinforced) in ground floor or pavings n exc 15 cm thickness below or above ground level complete all as specified and directed. |
| 2 | Demolition of brick or stone boulder masonry, built in cement mortar including all quoins, arches, Pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed. |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing coat) and rubbish off the premises complete all as specified and directed. |
| 4 | Taking down chowkhat with shutter (without taking off shutter from the frame) area exc 1.5 sqm but n.exc 4 sqm each complete all as specified and directed. |
| 5 | Taking down chowkhat with shutter (without taking off shutter from the frame) area n. exc 1.5 sqm each complete all as specified and directed. |
| 6 | Taking down shutters of any description exc 1.0 sqm but n. exc 2.0 sqm each complete all as specified and directed. |
| 7 | Taking up or down steel tubing & connection 15mm bore complete all as specified and directed. |
| 8 | Taking up or down steel tubing & connection 20mm bore complete all as specified and directed. |
| 9 | Taking up or down steel tubing & connection 25mm bore complete all as specified and directed. |
| 10 | Refixing 15mm old steel tubing and connections in new or old positions (walls, ceiling, floor etc) including fittings (new or old serviceable) required complete all as specified and directed. |
| 11 | Refixing 20mm old steel tubing and connections in new or old positions (walls, ceiling, floor etc)including fittings (new or old serviceable) required complete all as specified and directed. |
| 12 | Refixing 25mm old steel tubing and connections in new or old positions (walls, ceiling, floor etc)including fittings (new or old serviceable) required complete all as specified and directed. |
| 13 | M & L for GI tubing medium grade 15mm dia galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 14 | M & L for GI tubing medium grade 20mm dia galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 15 | M & L for GI tubing medium grade 25mm dia galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 16 | M & L for Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed. |
| 17 | M & L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built inCM 1:6 complete all as specified and directed. |
| 18 | Taking down cementor cement lime plaster on brick or stone walls etc. including raking out joints, hacking forkey, scrubbing down with water etc complete all as specified and directed. |
| 19 | M & L for rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surface finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 20 | M & L for rendering 15 mm thick in CM 1:4 with water proofing compound (@ 3% by weight of cement) on fair faces of brick work or concrete surface finishing the surface even and fair complete all as specified and directed. Note:- Water proofing compound shall be measured and paid separately |
| 21 | M & L for rendering 5 mm thick in CM 1:3 on concrete surface and finishing the surface even and smooth without using extra cement as on ceiling complete all as specified and directed. |
| 22 | M & L for preparation of new plastered surface of wall and applying minimum 1mm thick of wall care putty over prepared surface and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS-15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed.Note: Primer and emulsion shall be carried out through air less spray machine ( Machanical means) complete all as specified and directed. |
| 23 | M & L for preparation of new plastered surfaces of walls and applying two coats of OBD over a coat of 1mm thick wall care putty complete all as specified and directed.Note: Oil bound distemper shall be carried out through roller. |
| 24 | M & L for preparation of new plastered surface of ceiling and applying three coats of white wash complete all as specified and directed. |
| 25 | M & L for preparation of old treated surfaces of ceiling and applying two coats of white wash complete all as specified and directed. |
| 26 | M & L for complete removal of existing treatment on wall /roof projectios including facia, cornices etc by scrapping with mechanical sander (Having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean free from dust, loose paint etc by skilled labour and applying minimum 1mm thick of wall care putty over prepared surface and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS-15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed.Note: Primer and emulsion shall be carried out through air less spray machine ( Machanical means) complete all as specified and directed. |
| 27 | M & L for preparation of old plastered surfaces of walls and applying two coats of Oil Bound Distemper over a coat of 1mm thick wall care putty complete all as specified and directed.Note: Oil bound distemper shall be carried out through roller. |
| 28 | M & L for preparation ofold wood or wood based surface of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 29 | S & Fin repair Aluminium floor door stopper two legged and tongue with hard drawn steel spring fixed to floor 140mm complete all as specified and directed. |
| 30 | Supply only integral water proofing compound conforming to IS 2645 complete all as specified and directed. |
| 31 | M & L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm stone aggregate) as in sub base complete all as specified and directed. |
| 32 | M & L for colouredNon -Skid Ceramic tiles 7 to 8 mm thick area of each tiles exceeding 0.11sqm but not exceeding 0.18 sqm in floor etcset and jointed in neat cement slurry & pointed in coloured cement to match the surface over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and directed. |
| 33 | M & L for coloured glazed ceramic tiles 300 x 450 x 6-7 mm thick but as on vertical surfaces such as skirting/dado over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed. |
| 34 | M & L for Granite (Z black, Maroon, Ruby Red) 18-20mm thick (of any type work)(table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 20mm thick screed bed in CM 1:6 including moulding (rounding edges), dismantling of existing stone slabs etc complete all as specified and directed. |
| 35 | S & F in repair CP stop/angle valves 15mm bore fancy type chromium plated screwed down high pressure with quarter turn handle and wall flange complete all as specified and directed. |
| 36 | S & F in repair CP bib taps 15mm fancy type Chromium Plated with quarter turn handle and wall flange complete all as specified and directed. |
| 37 | S & F in repair PVC connection pipe 15mm bore 450mm long with PTMT nuts complete all as specified and directed. |
| 38 | Dismantling stone slab and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed. |
| 39 | M & L for machine cut Kota stone slab flooring 20-25mm thick over 20mm thick screed bed in CM 1:6, laid and jointed with grey cement slurry and pointed with grey cement & pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed. |
| 40 | M & L for machine cut Kota stone slab 20-25mm thick in, skirting, dado pillar laid over 10mm thick rendering in cement mortar 1:4 and jointed with grey cement slurry and pointed with mixture of grey cement and pigment to match the shade of the slab incl rubbing and polishing complete all as specified and directed. |
| 41 | Dismantling water tanks of capacity exc 500 & n. exc 1000 ltr complete all as specified and directed. |
| 42 | S & F for rotational moulded five layered white coloured polyethylene water storage tank cylindrical vertical with closed top hoisted & fixed in position of capacity 1000 litres complete all as specified and directed. |
| 43 | S & F in repair 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball & fixed complete all as specified and directed. |
| 44 | S & F in repair Gun-metal, globe or gate valves 20mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 45 | S & F in repair Gun-metal, globe or gate valves 25mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 46 | Taking down eaves gutters and rain waterpipes (any size or pattern) including all fittings, heads, shoes, bends, swan necks etc complete all as specified and directed. |
| 47 | S & F 110 mm PVC (SWR) pipes single socket in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 48 | S & F PVC(SWR) 110mm dia bends any radius complete all as specified and directed. |
| 49 | S & F in repair 100mm bore CI sand cast soil waste and vent pipe in any length with or without ears with cement joints laid in trenches or in floors complete all as specified and directed. |
| 50 | M & L for Run lead joints for 75-80mm spigot and socketed pipes and fittings complete all as specified and directed. |
| 51 | S & F in repair 75mm bore CI sand cast soil waste and vent pipe in any length with or without ears with cement joints laid in trenches or in floors complete all as specified and directed. |
| 52 | S & F cast iron bends (any radius) diminishing pieces or tapers for 100mm dia complete all as specified and as directed. |
| 53 | S & F 75mm bore CI Tee, single (equal or unequal), ordinary or inverted (Spigot or socketed type) or with parallel branches complete all as specified and as directed. |
| 54 | M & L for 75mm dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) (20mm graded stone aggregate) complete all as specified and directed. |
| 55 | M & L for 100mm dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) (20mm graded stone aggregate) complete all as specified and directed. |
| 56 | S & F Factory made single extruded WPC (Wood Polymer composite) soliddoor/window/ceosetory windows and other frames / chawkhat of size 65 x 125mm comprising of virgin PVC polymer of K value 58-60 (Suspension grade) Calcium carbonate and natural fibers (wood powder / rice husk / wheat husk) and non toxic additives (Max toxicity index 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws havinf min frame density of 750 kg/cum, screw withdrawal strength of 2200N (face) & 1100N (Edge), min compressive strength of 58N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof water / moisture proof and fire retardant and fixed in position with MS hold fasts / lugs/ stainless steel dash fasternersof required dia and length complete as per the direction of Engr-in-charge. (MS hold fasts / lugs / SS dash fasterners shall be paid seprately.) |
| 57 | S & F Factory made single extruded WPC (Wood Polymer composite) soliddoor/window/ceosetory windows and other frames / chawkhat of size 65 x 100mm comprising of virgin PVC polymer of K value 58-60 (Suspension grade) Calcium carbonate and natural fibers (wood powder / rice husk / wheat husk) and non toxic additives (Max toxicity index 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws havinf min frame density of 750 kg/cum, screw withdrawal strength of 2200N (face) & 1100N (Edge), min compressive strength of 58N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof water / moisture proof and fire retardant and fixed in position with MS hold fasts / lugs/ stainless steel dash fasternersof required dia and length complete as per the direction Note: MS hold fasts / lugs / SS dash fasterners shall be paid seprately. |
| 58 | S & F for providing 30mm thick factory made wire mesh solid WPC door shutter consisting of Density 650 Kg/Cum manufactured by an ISO-9001-2015 certified company, door to be panelled with SS mosquito mesh and XTN aluminium mesh for additional strength and safty purpose, (confirming as per IS : 4020).The door should be water proof, termite proof, fire retardant and having screw holding capacity.Door shutter to be fixed to frame with 3 Nos stainless steel butt hinges of size 100mmm x 25mm x 2mm and 32mm long steel screws drilled suitable to apss through both the wall of the MS Tube.other hardwares shouldbe fixed with 19x6 mm size steel swrews etc. complete as per direction of , manufacturer\"s specification and drawings.Note : Rate ofSS hinges,stainless steel wiremesh, XTN aluminium mesh include with quoted rate and nothing extra to be paid on this account. |
| 59 | S & F factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of30mm thick size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: Mild steel butt hinges shall be paid separately) |
| 60 | M & L for PCC type B-1 (1:2:4) (20mm graded stone aggregate) as in benching and coping complete all as specified and directed. |
| 61 | Demolition and breaking up 150mm dia drain pipes (salt glazed stoneware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed. |
| 62 | Excavation in trenches n. exc 1.5 wide and n. exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n. exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed. |
| 63 | M & L Cement concrete type D-2 (1:4:8) (40mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 64 | Returning filling in including spreading, levelling, watering and well ramming in layers n. exc 25 cm thickness in soft / loose soil complete all as specified and directed. |
| 65 | Removing excavated soils to a distance n. exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed. |
| 66 | M & L for 150mm dia Salt-glazed stone ware drain pipes laid in trenches and jointed as specified complete all as specified and directed. |
| 67 | M & L for Concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete 1:4:8 type D-2 for 150mm dia pipe complete all as specified and directed. |
| 68 | M & L for Precast cement concrete RCC 1:2:4 type B-1 using 20 mm graded stone aggregate set in cement mortar 1:4 as in cover slabs for drain / manhole cover incl demolition of existing complete all as specified and directed. |
| 69 | M & L for 10mm dia and overTMT bar, cut to length bent to shape required including cranking bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed. |
| 70 | M & L for Cutting chases pining in making to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting exceeding 20 cm girth to brick walls etc complete all as specified and directed. |
| 71 | Providing & Fixing 3000 Series windows fabricated from roll formed section made of Galvanized Steel Colour coated/powder coated(Base steel as per IS 513 \"D\" quality, Galvanised as per IS 277 with Zinc of 120 grams/Sq.Mtr) with total coated thickness of 0.60mm coated sections should be with Primer Coat of Epoxy Primer of 5-7 micron thick, finish painted with polyester paint of 12-16mm microns thick and back coated with Alkyd backer of 5-7microns, or powder coated with pure polyester powder upto 50-60 microns thick.Section for frame should be of 98mm x 50mm, section for Mullion should be of 46mm x 70mm, section for shutter frame should be of 46mm x 46mm, section for fixed glass bead should be 18mm x 25mm and section for fly mesh shutter frame should be of 20mm x 40mm.Frame and mesh shutter sections should be cut to length and mitre joint with corner brackets made of polypropylene, glass shutter should be mitre joint with corner brackets made of CRCA electroplated Mullion Section should be jointed with frame/mullion using Nylon mullion cap Ethylpropylene Diamine Monomer (EPDM) Gasket should be used all around glass in shutter between frame and glazed shutter and both sides of fixed glass.Spoon Profile should be used around fly mesh to fix mesh in mesh shutter.Each glazed shutter should be provided with MS Power Coated Friction Hinges-1sed, High Grade Aluminium Powder coated handle -1 No, Each mesh shutter should be provided with SS Pivot Hinges -1 set, Elixir make handle shall be provided per shutter.Window frame should be fixed to brick/concrete masonary by using Nylon self expanding caps and driving MS electroplated 80mm long screws into the caps through frames.Glass shutter & fixed glass portions should provided with a glass of 4mm plain float grass.Mesh shutter should be provided with a stainless steel 32 gauge fly mesh of 304 grades with 144 holes per square inch.Windows should be provided with grill made of 10mm sq. MS Bars welded to at 150mm center to certer, 6mm x 12mm MS flat, total grill unit should be powder coated and fixed to window frame with screws. |
| 72 | S & F anodised aluminium window and ventilator powder coated shutters top hung type without sash, aluminium section weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stay 150mm long (1 No) hinges type B-21 100mm long (2 No) suitable handle (1 No) complete all as specified and directed. |
| 73 | S & F 300 mm long aluminium alloy, sliding door bolt withhasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts complete all as specified and directed. |
| 74 | S & F 150mm size aluminium alloy handles, fabricated type extruded section, ISI marked complete all as specified and directed. |
| 75 | S & F for aluminiumanodized barrel tower bolts 200 mm of extruded section and fixed complete all as specified and directed. |
| 76 | S & FStainless Steel butt hinges 100mm size and fixed complete all as specified and directed. |
| 77 | Supply and fixing aluminium floor door stopper two legged and tongue with hard drawn steel spring fixed to floor 150mm complete all as specified and directed. |
| 78 | Supply and fixing 300mm mild steel ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified and directed. |
| 79 | M & L for 75 mm thick PCC 1:3:6, type C-1 using 20mm graded stone aggregate as in plinth protection, top finished even and smooth without using extra cement including making dummy joints 10x30mm size and filling the same with mix of 1 part of bitumen and 3 parts of sand at distance not exc 2.5 m and at every turning point complete all as specified and directed. |
| 80 | S & F in repair looking mirror fancy type decorative pattern 5 to 6mm thick fixed on wall with stainless steel studs complete all as specified and directed. |
| 81 | S & F in repair Curtain rod made of stainless steel fancy type with brackets including all fittings etc complete all as specified and directed. |
| 82 | M & L for obliterating number plaque and painting background using black synthetic enamel paint and building number with white synthetic enamel paint, overall area of plaque exc 0.10 sq m but not exc 0.40 sq m each complete all as specified and directed. |
| 83 | M & L for plain cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate and mixed with 2% integral water proofing compound as in padding over roof slab, finished surface even and smooth without using extra cement including demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.NOTE: (i)WPC shall measured and paid seperately. |
| 84 | Providing & laying polymer, water proofing compound & fiber based ready mix plaster for rendering 15 mm thick in CM (1:4) over roof surfaces, finished even & smooth without using extra cement complete as per manufacturer\"s instructions complete all as specified and directed |
| 85 | (a) Taking down existing water proofing treatment and cleaning of roof surface by washing and rubbing etc. and removing the retrieved material to a distance not exceeding 500m where directed.(b) Providing and applying fibre reinforced liquid applied elastomeric membrane made of Hybrid PU polymers by self priming with 30% water dilution and let it dry for 4-6hrs. Further apply 2 coats of waterproofing treatment fibre reinforced liquid applied elastomeric membrane made of hybrid PU polymers in a gap of 4-6hrs. The applied material should have specific gravity of 1.25g/cc with minimum recommended coverage of 1sqm/litre to built DFT of 650 microns. the cured membrane shall exhibit - 1. ) Tensile Strength ASTM D412 : 1.4-2.5 MPa2.) Elongation ASTM D412 : 400-500%3.) Adhesion Strength : >2N/sqm as per ASTM D45414.) Crack Bridging Ability : >3-4mm as per AS/NZS 4548:5:19995.) Water Permeability : NIL as per DIN 1048 (c) Providing and installing non-woven geo-textile membrane 40-50gsm with overlaps of 50mm in both directions over the Ist coat when the surface is still tacky. |
| 86 | SURFACE PREPARATION: Prepration of existing surfaces like chipping of unsound weak / loose concrete/cover of reinforcement and removal of debries to a designated location (upto full height) block to support the structure proisionally during repair work and maintaining them in positioin till required, complete all specified and directed by the Engineer-in-charge. |
| 87 | For rusted exposed reinforcement apply & supply of Sika Rustoff 100 or equivalent rust remover with brush for complete wetting of rusted metal surface and allowed to react it for 16-24 hours.After 24 hours, a white layer will appear which will protect further corrosion of metal / steel for about 5-7 days including surface preparation and errection of steel porps. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth,complete all as specified and as directed by Engr-in-charge Note: Work to be executed by the authorised applicator of manufacturer only. (Mode of area measurement will be chipped concrete in sqm) |
| 88 | CORROSION RESISTANCE COATING.Providing and Application ofSika Friazinc R or equivalent as passivator/ Anti corrossion coating to the steel reinforcement shall beapplied . The material shall be two component,cement based polymer modified two component coating for corrosion protection.The material shall be prepacked and ready to use. It shall be fully compatible with the reinstatement methods adoptedcomplete all as specified and as directed by Engr-in-charge.This shall include surface preparation and errection of steel porps as required for the application.Note: Work to be executed by the authorised applicator of manufacturer only. (Mode of area measurement will be chipped concrete in sqm) |
| 89 | EPOXY BONDING AGENT.Appplying & supply of two component solvent free epoxy bonding agent Sika Sikadur 32LP or equivalent for bonding old to new concrete . The ready to use epoxy bonding agent shall be applied over old concrete using brush after cleaning of surface of all dust or latiance.The material issupplied as a two part material in preweighed quantities for ready onsite mixing and use. The material shall exhibits the following properties Compressive strength 50 N/mm2 at 7D Flexural strenght 35N/mms at 7 D , Shear strength 10N/mm2 at 7D and Tensile strength 20 N/mm2 and Bond Strength of 10N/mm2.The new concrete shall be placed within the open time as specified by the manufacturer to ensure maximum bondingand application shall be as per the manufacturer instruction ,complete all as specified and as directed by Engr-in-charge.Note: Work to be executed by the authorised applicator of manufacturer only. |
| 90 | PATCH WORK FOR INSUFFICIENT CONCRETE COVER OR SOFFIT AREA OF CONCRETE.Providing and ApplyingSika Monotop 122 F or equivalent ready to use single component fibre reinforced high strength polymer modified cementitious repair mortar in 25 mm thickness.Water /Powder ratio shall be as specified by manufacturer so as to achieve the following parameters:- .28 days Compressive Strength >=50N/mm2 Flexural strength at 28 days >= 5 N/mm2Note: Work to be executed by the authorised applicator of manufacturer only. |
| 91 | Taking down copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or taking credit and making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 92 | Taking down VTPN DBs andMCB DBs any type and size including MCBs/MCCBsremoving materials to store for keeping in safe custody or taking credit and making good the disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 93 | M&L for point wiring with single core FRLS PVC insulated 1100V grade cable with multistranded copper conductor of size 1.5 Sq. mm (Nominal area) drawn in and including non metallic rigid PVC concealed conduit, medium grade ISI marked not less than 20 mm dia, concealed in wall, ceiling with saddles, screw & Plugs with all fittings includingtee, junction boxes and drawing continuous earth wire of FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 sqmm and terminated in and including sunken box upto 12 modulefor one light/fan point controlled bymodular switches/sockets, regulators etc complete all as specified and directed |
| 94 | All as per Serial item No. 93 here in before but One 3 Pin, 6 Amp socket outlet point on an independent board with cable size 1.5 sqmm. |
| 95 | All as per Serial item No. 93 here in before but One 3 Pin, 6 Amp socket outlet point on same board with other switches with cable size 1.5 sqmm. |
| 96 | All as per Serial item No. 93 here in before but One 3 pin, 16 Amp socket outlet point on an independent board with cable size 2.5 sqmm. |
| 97 | Supply and fixing modular switch , one way, 06 Amps complete all as specified and directed. |
| 98 | Supply and fixing modular switch, one way, 16 Amps complete all as specified and directed . |
| 99 | Supply and fixing modular socket outlet 2 in 1, 5 pin, 06 Amps complete all as specified and directed. |
| 100 | Supply and fixing modular socket outlet 2 in 1, 3 pin, 06/16 Amps complete all as specified and directed . |
| 101 | Supply and fixing white cover plate with frame modular type of 03 module complete all as specified and directed. |
| 102 | Supply and fixing white cover plate with frame modular type of 04 module complete all as specified and directed. |
| 103 | Supply and fixing white cover plate with frame modular type of 06 module complete all as specified and directed . |
| 104 | Supply and fixing white cover plate with frame modular type of 12 module complete all as specified and directed . |
| 105 | Supply & fix modular fan regulator 100 / 100 W, in 2 Module for ceiling fan and connecting as directed. |
| 106 | S&F angle type holder insulated body with back plate suitable for batten fittings complete all as specified and directed . |
| 107 | Supply and fix ceiling rose, three terminals, polycarbonate body complete all as specified and directed. |
| 108 | Supply only LED bulb 7/9 watt complete all as specified and directed . |
| 109 | S& F Decorative wall light fixturemade up of Metal base, synthetic white in colour and square/round metal base with bend pipe and glass globe with nickel finish,with 01 No. 9 W LED Bulb, 230 V, 6000K, complete incl all required electrical connecting arrangements complete all as specified and directed.Note: Rates incl 01X 9 W LED Bulb with each fitting. |
| 110 | Supply and Fixing wall/surface mountingluminaires integrated LED Batten 20 W, 6000 K,120 lumens/watt , 230V with extruded Aluminium housing4 feet long with frosted PMMA/PC diffuser & integrated electronic driver complete including Electrical connection with PVC three core copper flexible wire & all necessary fixing arrangementscomplete all as specified and directed. |
| 111 | S&F in repair LED Building security light 25 Watt with high power LED source (>110lumen/watt) PDC housing, IP65 and IK 07with 4 KV inbuilt surge protection potted driver including Electrical connection with PVC three core copper flexible wire & all necessary fixing accessories such as bracket of GI pipe light grade 40 mm dia 0.60 mtr long bend to shape as per suitable size along with all accessories, fixed on wall including bolts & nuts complete all as specified and directed . |
| 112 | M&L for Submain wiring with two single core unsheathed, PVC (FRLSH) insulated, 1100 Volts grade cable with 6.0 sqmm nominal cross sectional area Multi-stranded copper conductor and one single core green unsheathed, PVC (FRLSH) insulated, 1100 Volts grade cable with 6.0 sqmm Multi-stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 25 mm dia including all conduit and fixing accessories concealed in wall including cutting chases in wall and making good disturbed surface to match of walls/ceiling complete all as specified and directed . Note - PVC Conduit and accessories shall be deemed to be included in the quoted rate |
| 113 | M&L for Submain wiring with two single core unsheathed, PVC (FRLSH) insulated, 1100 Volts grade cable with 4.0 sqmm nominal cross sectional area Multi-stranded copper conductor and one single core green unsheathed, PVC (FRLSH) insulated, 1100 Volts grade cable with 4.0 sqmm Multi-stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia including all conduit and fixing accessories concealed in wall including cutting chases in wall and making good disturbed surface to match of walls/ceilingcomplete all as specified and directed . Note - PVC Conduit and accessories shall be deemed to be included in the quoted rate |
| 114 | S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 12 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, IK09, True IP 43 (with PU Gasket) with test certificate factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed. |
| 115 | Supply and fixing of MCB SP 240 volts, C Curve of32 Amps, 10 KA Current carraying capacity complete all as specified and directed. |
| 116 | Supply and fixing of MCB SPN 240 volts, C Curve of 40 Amps, 10 KA Current carraying capacity complete all as specified and directed. |
| 117 | Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed |
| 118 | S&F of exhaust fan single phase, 230 Volt heavy duty of size 380 mm sweep 1400 RPM including suitable louvers and making connection with twisted copper flexible wire 23/0.076mm complete all as specified and directed . |
| 119 | M&L for Cutting, opening circular/Rectangular in shape hole on wall for fixing ofexhaust fan of size 300/380 mm sweep incl plastering and making good the disturbed surface surrounding complete all as specified anddirected. |
| 120 | S&F in replacement of double door VTPN 4 way double door suitable for 4 pole MCCB 125A, 415 V as incoming & SP/TP MCB as outgoing 200 Amps rated Busbar, inter connection link, cable ties,earth bar etc incl necessary civil works and electrical connections with suitable lugs/spreader links complete all as specified and directed . Note: MCCB-01 Noof125A&MCB- 04 no of 32A and MCB - 08 no of 63 A to be measured and paidunder this item |
| 121 | S&F Modular Power unit with socket plug top and MCBs with single pole and neutral enclosure with a two pin and one pin for earth plug and socket complete with one single pole MCB 16/20 Amp complete all as specified and directed . |
| 122 | S&F Wall mounted fan 400mm Sweep ,240v, 50hz complete all as specified and directed |
| 123 | Taking Down Disconnecting of ceiling fans / exhaust fan of any size from ceiling rose/connector for cleaning,servicing /oiling and greasing of fan by using appropriate grade of oil/grease and replacing defective parts such as bush bearing , split pin rubber bush, capacitor etc and rehanging the same after proper cleaning and making connection with ceiling fan/connector with flexible wire of size 23/0076 copper conductor multi stranded complete all as specified and directed |
| 124 | M&L ofEarthing complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground(earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of nut, bolts, check nut & washer of galvanized iron or of steel, earth lead protected by 15 mm dia GI pipe light grade watering pipe 20 mm dia GI light grade GI wire meshed funnel alternate layer of char coal and salt PCC chamber, reassed for and including RCC cover including all necessary excavation & earth work, earth 7.5 mtr wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 1991 print and complete all as per specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail