| 1 | Taking down chowkats or frames n.exc 1.50 sqm each, without taking off shutters from the frames including iron mongry complete all as specified and as directed. |
| 2 | Taking down ofshuttersof any description of area exc1.00 sqm but n. exc 2.00 Sqm each complete all as specified and as directed. |
| 3 | S&F 35 mm thick Glazed and skeleton shutters 2nd class hard wood, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed. |
| 4 | S & F Plain, framed, panelled shutters 35 mm thick in 2nd class hard wood (any number ofpanels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed. |
| 5 | Refixing of Shutters after necessary repairs, of any description exc 1 sqm and n exc 2 sqm in same opening , complete all as specified and as directed. |
| 6 | S&F factory made single extruded WPC (wood polymer Composite) solid door/ window/ Ceosetory window & other Frames/ Chowkhat of size 45 x 70 mm comprising ofPVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wwod powder/ rick husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded stat headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N / mm 2 and resistance to spread of flame of Class A catogory with property of being termite/ borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note:- For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and as directed. |
| 7 | S&F factory made single extruded WPC (wood polymer Composite) solid plain flush door shutter of 30 mm thickcomprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrwal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N mm2 modulus of elasticity 850 N / mm2 and resistance to spread of flame of Class A catogary with property of being termite/ borer proof, water/ moisture proof and fire retardanat and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-In-Charge (Note:- stainless steel butt hinges and necessary SS screws shall be paid separately. |
| 8 | S&F Mild steel butt hinges, medium weight cold rolled 100mm sizecomplete all as specified and as directed. |
| 9 | S&F 150mm long aluminium anodized, barrel tower bolt of extruded section complete all as specified and as directed. |
| 10 | S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 11 | S&F Anodised aluminium alloy handles cast type, each 150mm long complete all as specified and as directed. |
| 12 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc,) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and as directed. |
| 13 | S&F Powder coated aluminium anodised snap grid system of grid size 600 X 600 mm fixed to walls with rawl plugs and screws and hang to roof members with 2 mm dia GI wire comprising of the Main Tee 28x24x3mm thick, Cross Tee 28x24x3mm thick and Wall angle 24x24x3mm thick sections complete all as specified and as directed. |
| 14 | S&F 4 mm thick Everest designer ceiling (E-board classic) board / tiles for insulation and accoustic purpose, 595 X 595 mm size fixed with staples on GI/Aluminium snap grid as in ceilingwith and including dusting of surface and applying two coats of oil bond distemper over a coat of primer complete all as specified and as directed. |
| 15 | S&F 6mm thick decorative PVC Sheet hollow (design approved by GE) for insulation and acoustic purpose on wall/ceiling surface, screw to timber frame work for levelling of wall as reqd, including with panelling to vertical surfaces, fixed with rawl plug and screws complete all as specified and as directed. |
| 16 | M&L for preparing of old plastered wall surfaces andapplying one coat of distemper oil emulsion, complete all as specified and as directed. |
| 17 | Dismantling laid dry or laid dry and pointed Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and as directed. |
| 18 | M & L Machine cut Kota stone slab flooring 20-25mm thick over and including cement screed base 20mm thick in cement mortar 1:3, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 19 | Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slabincluding 15mm thick rendering in CM 1:4 including rubbing and polishing complete all as specified and as directed. |
| 20 | M&L 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cement screed base 20mm thick in cement mortar 1:3 complete all as specified and as directed. |
| 21 | S&F in repairs 600 mm x 450 mm beveled edge mirror of selected quality glass 5.5mm thick mounted on 6mm thick AC building board or commercial plywood & fixed with wooden plugs with chromium plated brass screws and washer and aluminum beading complete all as specified and as directed. |
| 22 | S & F in repairs,Aluminum die cast body door closer hydrau lically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed. |
| 23 | M&L forpreparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint ,complete all as specified and as directed. |
| 24 | M&L for preparation of old painted steel surfaces of any description over 10 cm width girth and applying one coat of synthetic enamel paint, all as specified and directed by Engr-in Charge. |
| 25 | S & F 5.50mm thickSheet glass, ordinary quality and glazing with oil putty in square n exc 0.50 Sqm in each pane with hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beadsall complete all as specified and as directed. |
| 26 | S&F in repair, Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and as directed. |
| 27 | Figured glass, 3mm thk pin head type and glazing with oil putty in squares n exc 0.5 sqm in each pane complete all as specified and as directed. |
| 28 | S&F in repairs of20mm dia harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed. |
| 29 | S&F in repairs tubular towel rail brass chromium plated 20mm dia D type 60cm long complete all as specified and as directed. |
| 30 | S & F in repair Bib tap 15mmcast copper alloy, bright, crutch or butter fly handle screwed down, fancy type chromium plated for iron pipes complete all as specified and as directed. |
| 31 | S & F in repair 15mm stop valve / angle valve, cast copper alloy screwed down high pressure with crutch or butter fly handle of fancy type chromium plated screwed both ends of,complete all as specified and as directed. |
| 32 | S&F in repair Soap dish wall mounted Meridian Double Soap Dish of Stainless steel Chromium plated finish, fixed to plugs with chromium plated brass screws, complete all as specified and as directed.Cat Part No: Cera, F5015126CH or equivalent in Jaquar/Prayag/Hindware. |
| 33 | S&F in repair, PVC connection pipe 15mm dia, 600mm long with PTMT check nuts and washer on both ends complete all as specified and as directed. |
| 34 | S&F in repair, 1000 ltrs capacity white colour three layer rotational moulded polythene water storage tank (Cylinderical vertical with closed top) hoisted and fixed in position with20mm bore dia ball vallves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ballscrewed for iron pipe and fixed, (Minimum weight 15mm-142gms /20 mm- 210 gms/ 25mm-455gms/ 40mm - 690 gms) , all as specified in SSR Part-I, complete including dismantling of existing tank complete all as specified and as directed. |
| 35 | S&F in repairs Gun Metal globe or gate valve with iron wheel head, screwed both ends for iron pipe, 20mm bore complete all as specified and as directed. |
| 36 | S&F in repair 10 ltr capacityPVC valveless,syphonic action type, flushing cistern, low level, white, with inlet ball valve , float and handle including brackets, complete all as specified and as directed. |
| 37 | S & F in repair, 110mm bore PVC (SWR) soil, waste & vent pipe single socketed in any length with runbber ring joints & fixed to walls or in floor, in repairs complete all as specified and as directed. |
| 38 | S & F 110mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 39 | S & F 110mm dia PVC cowls complete all as specified and as directed.. |
| 40 | S & F PVC (SWR)branch Piece single ( DobleY ) equal or unequal Dia 110mm complete all as specified and as directed. |
| 41 | M&L for preparing old plastered ceiling surfaces and applying two coat of white wash complete all as specified and as directed. |
| 42 | S& F in repairs floor door stopper of aluminium alloy body with steel spring 150 mm fixed to door complete all as specified and as directed. |
| 43 | M&L for sunken floor treatment as under:- (i) The sunken portion shall be tested for leakage / seepage / dampness by ponding with water for 72 hours. In case any defect is noticed, the defective portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage/ seepage/ dampness is eliminated.(ii) Demolition ofcement concrete of any description and in any position not otherwise specifically provided for in any type of filling in sunken portion & cleaned the sunken potion including vertical wall surface complete all as directed.(iii)Laying of 40mm thick (Min) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate with integral water proofing compound as per manufacturer instructions on bottom of sunken portion with proper slope towards spout. Vertical sides shall be plastered in CM (1:3), 15 mm thick mixed with water proofing compound as per manufacturer instructions. Plaster shall be extended over PCC coving when the same is green i.e. PCC & plaster be carried out at the same time complete all as specified and as directed.(iv) After laying sewage/ plumbing pipes with fixtures in position, 2 coats of OMIPLAS EP-101 epoxy compound shall be applied completeall as specified and directed.(v) Testing again of water tightness by ponding for 72 hours & rectifying defects if any till total elimination of defects complete all as specified and directed.(vi) M&L to fill the sunken floor with PCC ( 1:5:10) type E-2 using 40mm graded brick aggregate over the treated surface complete all as specified and directed.(vii) Provinding spouts of25mm dia GI pipe light grade projecting 450mm from clear outer suraface of wall with mosquito proof cap on inner face of pipe shall be provided to drain out seepage water, including cutting holes and making good if needed complete all as specified and as directed. |
| 44 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 45 | M & L 15mm thick screed bed in cement mortar 1:6 under floor tiles, complete all as specified and as directed. |
| 46 | M&L for heavy duty tiles exterior grade 300 x 300 x 10mm in CM 1:6,set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and as directed. |
| 47 | M & L Anti skid Ceramic coloured tiles of size 600x600x7-8mm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on, complete all as specified and as directed. |
| 48 | M & L Anti skid Ceramic coloured tiles of size 400x400x7-8mm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on, complete all as specified and as directed. |
| 49 | M & L Glazed ceramic coloured tiles in vertical surface 450x300x7-8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering in CM 1:4 etc complete all as specified and as directed. |
| 50 | Demolition brick work or stone/ boulder masonery built in cement mortar including all quoins , pillars etc complete all as specified and as directed. |
| 51 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding6m mean radius, built in CM (1:6) complete all as specified and as directed. |
| 52 | M & L Precast cement concrete block masonry with solid blocks PCC Type C1 (1:3:6) (using 20mm graded aggregate) exc 10cm in width and setting in CM 1:6 complete all as specified and as directed. |
| 53 | M & L for providing cement concrete Type C1 (1:3:6) 20 mm graded in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, filling hollow of frame with plain cement concrete complete all as specified and as directed. |
| 54 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 55 | M & L for 75 mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement complete all as specified and as directed. |
| 56 | M&L PCC ( 1:4:8) D-2, using 40mm graded stone aggregate in fdn.,filling and mass concrete complete all as specified and as directed. |
| 57 | M & L for PCC ( 1:2:4) type B-1, using 20mm graded stone aggregate in cement concrete in surface channels and drains complete all as specified and as directed. |
| 58 | Extra for forming fair finished drain or channel 30 cm inner girth in cement complete all as specified and directed. concrete, using ex- tra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and as directed. |
| 59 | Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc.&removing rubbish to a distance not exc 250m complete all as specified and as directed. |
| 60 | M&L for rendering 15 mm thick Readymade plaster on inner/outer walls with Ultra Tech READIPLAST by adding 17-19% of potable water by weight of material. for thickness above 15mm, it is recommended to be applied in multiple layers. Ready mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 days- 10-12 Mpa/Bulk density-1500-1600 kg/cum. Note : The rate quoted by the contractor shall include cleaning of surface, application as per instruction and scaffolding upto 10 mtr height, complete all as specified and as directed. |
| 61 | M&L for preparing newly plastered wall surfaces andapplying two coat of distemper oil emulsion over 1mm thick wall care putty, complete all as specified and as directed. |
| 62 | M&L preparation of previously untreated or newly plastered wall surfaces and applying two coat of weather proof paint over and including a coat of wall primer (Alkali resistant) including filling up of holes by wall care putty wherever required, all as specified and directed by Engr-in Charge. |